Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microwave”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

One-dimensional mapping of femtosecond laser filaments using coherent microwave scattering

Here, this paper reports on the use of coherent microwave scattering (CMS) for spatially resolved electron number density measurements of elongated plasma structures induced at mid-IR femtosecond filamentation in air. The presented studies comprise one-dimensional mapping of laser filaments induced via 3.9 µm, 127.3 fs laser pulses at output energies up to 15 mJ. The axial electron number density was measured to be invariant (about 2 × 10 15 c⁢m −3 ) along the entire filament length and for all tested laser pulse energies 5–15 mJ, and the corresponding laser intensity in the middle portion of the filament was estimated to be nearly constant for 5–15 mJ pulse energies (about 30−40 TW/c⁢m 2 ). These findings support that intensity clamping conditions were achieved in the experiments. The proposed approach enables capabilities that are currently unavailable to perform absolute and longitudinally resolved measurements of electron number density in laser filaments and to precisely characterize conditions associated with self-focusing and intensity clamping.

plasma diagnostic techniques↗

Dark Photon Limits from Patchy Dark Screening of the Cosmic Microwave Background

Dark photons that kinetically mix with the Standard Model photon give rise to new spectral anisotropies (patchy dark screening) in the cosmic microwave background (CMB) due to conversion of photons to dark photons within large-scale structure. We utilize predictions for this patchy dark screening signal to provide the tightest constraints to date on the dark photon kinetic mixing parameter [ ϵ ≲ 4.5 × 10 − 8 (95% confidence level)] over the mass range 10 − 13 eV ≲ m A ′ ≲ 10 − 11 eV , almost an order of magnitude stronger than previous limits, by applying state-of-the-art component separation techniques to the cross-correlation of CMB and unWISE galaxy survey data. Published by the American Physical Society 2024

McCarthy, Fiona (ORCID:0000000253893565)↗

Probabilistic Analysis of Long-Term Degradation of Microwave Cavity Flow Sensor

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. We have performed a proof-of-concept experiment of flow sensing with the transducer in liquid sodium at 340°C in impinging liquid jet geometry. The transducer remained in liquid sodium for 70 days. After removal, no structural damage was observed, and the expected transducer response was verified in a water test. Because long-term (multi-year) experimental tests of transducer resilience to harsh environment are not practical, we have developed a probabilistic model of creep to estimate transducer resilience to the harsh environment. The probabilistic model considers diffusion creep under the condition of high temperature and low stress, where the stress and temperature are allowed to be random variables with Gaussian distributions. Using the probabilistic model, we estimate inelastic membrane deflections due to creep for several temperature ranges. We conclude that for temperatures less than 650°C, creep has negligible long-term effect on the transducer performance. Since a yellowish residue was observed on the transducer surface after 70 days of immersion in liquid sodium, we have investigated possible evidence of corrosion. Chromium depletion is a typical indicator of the corrosion process in stainless steel. Scraping off a residue from the transducer and performing scanning electron microscopy (SEM) with energy dispersive analysis (EDS) did not find any chromium in the residue. Approximately 60% of the residue consisted of copper, which can be attributed to contamination of sodium due to powder residue from machining of copper and brass components of the transducer.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Frequency-Selectable Laser Source (FLS) for Cosmic Microwave Background Experiments

Cosmic Microwave Background (CMB) experiments measure remnant radiation from the early universe and use that data to determine fundamental properties of the universe. We can constrain key parameters, such as \textit{r}, the cosmic tensor-to-scalar ratio, and $N_\text{eff}$, the effective number of relativistic species, by analyzing the CMB power spectra. Improving our measurements of the CMB requires improving our instrument systematics, one of the most important of which is detector bandpass. Current experiments use a Fourier Transform Spectrometer (FTS) to measure bandpass. However, the FTS is systematics limited, and cannot achieve the accuracy needed to make improved CMB measurements. For this reason, we are developing a new instrument, the Frequency-Selectable Laser Source (FLS) to decrease the uncertainty in bandpass by an order of magnitude. In this paper, we describe work completed to support the version 2 upgrade to the FLS. Using ray-tracing software, we modeled the FLS optics to set physical tolerances for the new design. We also discuss the laser calibration, and future work to be completed in further development of the FLS upgrade.

Rosen-Turits, Gabriel M.↗

NANT Site - Microwave Radiometer Thermodynamic Retrievals TROPoe / Derived Data

This dataset contains daily files with thermodynamic profiles retrieved with the optimal estimation physical retrieval TROPoe (Turner and Löhnert 2014; Turner and Blumberg 2019; Turner and Löhnert 2021). The profiles are retrieved every 10 minutes from instantaneous brightness temperature measurements at 35 channels observed with a microwave radiometer MP3000A operated by NOAA Physical Sciences Laboratory on Nantucket Island for WFIP3. Additional input data in TROPoe are cloud base height from a collocated ceilometer operated by NOAA GML and temperature, water vapor mixing ratio, and pressure from a sensor attached to the MWR housing. In addition to these temporally resolved input data, TROPoe requires an a priori dataset (prior) that provides mean climatological estimates of thermodynamic profiles and specifies how temperature and humidity covary with height as an input (for details see, e.g., Djalalova et al. 2022). The prior is a key component of the retrieval and provides a constraint on the ill-posed inversion problem. A monthly prior was computed from operational radiosonde launches at Upton, NY.

17 WIND ENERGY↗

NOAA PSL Microwave Radiometer Block Island / Thermodynamic retrievals TROPoe

This dataset contains daily files with thermodynamic profiles retrieved with the optimal estimation physical retrieval TROPoe (Turner and Löhnert 2014; Turner and Blumberg 2019; Turner and Löhnert 2021). The profiles are retrieved every 10 minutes from instantaneous brightness temperature measurements at 35 channels observed with a microwave radiometer MP3000A operated by NOAA Physical Sciences Laboratory on the Block Island for WFIP3. Additional input data in TROPoe are cloud base height from a collocated ceilometer operated by NOAA GML and temperature, water vapor mixing ratio, and pressure from a sensor attached to the MWR housing. In addition to these temporally resolved input data, TROPoe requires an a priori dataset (prior) that provides mean climatological estimates of thermodynamic profiles and specifies how temperature and humidity covary with height as an input (for details see, e.g., Djalalova et al. 2022). The prior is a key component of the retrieval and provides a constraint on the ill-posed inversion problem. A monthly prior was computed from operational radiosonde launches at Upton, NY.

17 WIND ENERGY↗

Microwave Radiometer

This dataset contains daily files with thermodynamic profiles retrieved with the optimal estimation physical retrieval TROPoe (Turner and Löhnert 2014; Turner and Blumberg 2019; Turner and Löhnert 2021). The profiles are retrieved every 10 minutes from instantaneous brightness temperature measurements at 35 channels observed with a microwave radiometer MP3000A operated by UND on the Barge for WFIP3. Additional input data in TROPoe are cloud base height from a collocated ceilometer operated by NOAA GML and temperature, water vapor mixing ratio, and pressure from a sensor attached to the MWR housing. In addition to these temporally resolved input data, TROPoe requires an a priori dataset (prior) that provides mean climatological estimates of thermodynamic profiles and specifies how temperature and humidity covary with height as an input (for details see, e.g., Djalalova et al. 2022). The prior is a key component of the retrieval and provides a constraint on the ill-posed inversion problem. A monthly prior was computed from operational radiosonde launches at Upton, NY.

17 WIND ENERGY↗

Probing Physics beyond the Standard Model through Combined Analyses of Next-generation Type Ia Supernova, Cosmic Microwave Background, and Baryon Acoustic Oscillation Surveys

Observations of Type Ia supernovae (SNe Ia), which probe the late Universe, together with baryon acoustic oscillations (BAO) and the cosmic microwave background (CMB), which probe the intermediate and early epochs, provide complementary constraints on the expansion history of the Universe. In this work, we forecast constraints on dark energy and other extensions to the standard cosmological model by combining the SN Ia sample expected from the Vera C. Rubin Observatory’s Legacy Survey of Space and Time (LSST), data from current and forthcoming CMB surveys, and BAO measurements from the Dark Energy Spectroscopic Instrument (DESI). For the CMB, we use temperature, polarization, and lensing power spectra (TT/EE/TE/ϕϕ) from the South Pole Telescope, the planned Advanced Simons Observatory, and a CMB-S4–like experiment. We derive constraints on ΛCDM and its extensions involving the dark energy equation-of-state parameters (w 0 , w a ) and the sum of neutrino masses ∑m ν using a Markov Chain Monte Carlo (MCMC) sampling framework. We find that the LSST Year 3 SN Ia sample can improve upon the DES Year 5 dark energy constraints by a factor of 2−2.5×, with the gains driven primarily by the significantly higher SN Ia density in the LSST sample. Similarly, DESI-DR3 shows up to a 1.8× improvement on dark energy parameters over DR2, driven largely by the substantial increase in the low-redshift sample. Combining CMB with LSST-Y3-SN Ia and DESI-DR3-BAO yields σ(w 0 ) = 0.028 and σ(w a ) = 0.11 for w 0 w a CDM cosmology with the results being largely independent of the CMB dataset. The constraints weaken by 10%–30% when freeing ∑m ν and spatial curvature. Moreover, the joint analysis of the three datasets can enable a 2σ–3σ detection of ∑m ν .

Raghunathan, Srinivasan [University of California;↗

The Thermal and Kinematic Sunyaev–Zeldovich Effect in Galaxy Clusters and Filaments Using Multifrequency Temperature Maps of the Cosmic Microwave Background: A399–A401 Cluster Pair Case Study

We present a multifrequency and multi-instrument methodology to study the physical properties of galaxy clusters and cosmic filaments using cosmic microwave background observations. Our approach enables simultaneous measurement of both the thermal (tSZ) and kinematic Sunyaev–Zeldovich (kSZ) effects, incorporates relativistic corrections, and models astrophysical foregrounds such as thermal dust emission. We do this by jointly fitting a single physical model across multiple maps from multiple instruments at different frequencies, rather than fitting a model to a single Compton-y map. We demonstrate the success of this method by fitting the A399–A401 galaxy cluster pair and filament system using archival data from the Planck satellite and new, targeted deep data from the Atacama Cosmology Telescope, covering 11 different frequencies over 14 maps from 30 GHz to 545 GHz. Our tSZ results are consistent with previous work using Compton-y maps. We measure the line-of-sight peculiar velocities of the cluster–filament system using the kSZ effect and find statistical uncertainties on individual cluster peculiar velocities of ≲600 km s −1 , which are competitive with current state-of-the-art measurements. Additionally, we measure the optical depth of the filament component with a signal-to-noise of 8.5σ and reveal hints of its morphology. This modular approach is well-suited for application to future instruments across a wide range of millimeter and submillimeter wavebands.

Gill, Ajay S. [National Research Council of Canada↗

PROTOCALC, a W -band Polarized Calibrator for Cosmic Microwave Background Telescopes: Application to Simons Observatory and CLASS

Current- and next-generation cosmic microwave background (CMB) experiments will measure polarization anisotropies with unprecedented sensitivities. The need for high precision in these measurements underscores the importance of gaining a comprehensive understanding of instrument properties, with a particular emphasis on the study of the beam properties, and especially their polarization characteristics and the measurement of the polarization angle. In this context, a major challenge lies in the scarcity of millimeter polarized astrophysical sources with sufficient brightness and calibration knowledge to meet the stringent accuracy requirements of future CMB missions. This led to the development of a drone-borne calibration source designed for the frequency band centered on approximately 90 GHz, matching a commonly used channel in ground-based CMB measurements. The Prototype Calibrator for Cosmology, PROTOCALC, has undergone thorough in-lab testing, and its properties have been subsequently modeled through simulation software integrated into the standard Simons Observatory analysis pipeline. Moreover, the PROTOCALC system has been tested in the field, having been deployed twice on calibration campaigns with CMB telescopes in the Atacama Desert. The data collected constrain the roll angle of the source with a statistical accuracy of 0$^°_•$045.

79 ASTRONOMY AND ASTROPHYSICS↗

Fast Machine Learning for Quantum Control of Microwave Qudits on Edge Hardware

Quantum optimal control is a promising approach to improve the accuracy of quantum gates, but it relies on complex algorithms to determine the best control settings. CPU or GPU-based approaches often have delays that are too long to be applied in practice. It is paramount to have systems with extremely low delays to quickly and with high fidelity adjust quantum hardware settings, where fidelity is defined as overlap with a target quantum state. Here, we utilize machine learning (ML) models to determine control-pulse parameters for preparing Selective Number-dependent Arbitrary Phase (SNAP) gates in microwave cavity qudits, which are multi-level quantum systems that serve as elementary computation units for quantum computing. The methodology involves data generation using classical optimization techniques, ML model development, design space exploration, and quantization for hardware implementation. Our results demonstrate the efficacy of the proposed approach, with optimized models achieving low gate trace infidelity near $10^{-3}$ and efficient utilization of programmable logic resources.

Sanders, Flor [Columbia U.]↗