Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “metering system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Impacts of Dispatch Strategies and Forecast Errors on the Economics of Behind-the-Meter PV-Battery Systems

To assess the economic value of batteries in hybrid PV-battery systems, one must create a dispatch profile for the battery. Many analyses of battery value assume perfect forecasts of PV generation and load, determining an upper limit on the value of the battery. Prior work that accounts for forecast uncertainty often does so in the context of a single dispatch algorithm, which does not provide a baseline for comparison. Furthermore, when multiple dispatch algorithms are assessed with uncertainty, the benefits considered are for diesel generation in a microgrid, not retail rate savings. This work addresses the gaps in the literature by comparing the performance of both heuristic and optimal dispatch algorithms for retail rate savings under forecast uncertainty, and provides comparisons of the robustness of these algorithms and their associated estimates of economic value. We find that using a perfect forecast can overestimate the value of hybrid PV-battery systems between 1% and 8% compared to the reality of using a day-ahead forecast, depending on the dispatch algorithm used. Thus, accounting for forecast uncertainty in system design and analysis will significantly improve the accuracy of modeled system values.

batteries↗

The development of the 15-Meter Hoop Column deployable antenna system with structural and electromagnetic performance results

This paper presents the technical results obtained during the development and engineering tests of a 15-Meter Hoop Column deployable antenna system. An important element of the 15-meter antenna program was the structural tests and the characterization of the surface accuracy of the deployed mesh surface. The overall system performance of the 15-meter antenna was obtained during radio frequency tests conducted in the Martin Marietta Near Field Test Laboratory in Denver, CO. The near field tests verified the electromagnetic performance of the structure which exhibited a surface accuracy of 0.061 in (RMS). Radio frequency tests were conducted at 2.3, 4.3, 7.7, and 11.6 GHz. The experiment and analytical results obtained through the 15-meter antenna program will provide new opportunities for the application of large space antennas for future missions.

Campbell, T. G.↗

Four-color infrared bolometer system for one-meter telescope

A far-infrared photometer has been developed as a focal plane instrument for a balloon-borne 102-cm telescope. The four gallium-doped Ge bolometers adopted for the system operate at 1.8 K in a liquid-helium dewar. Wavelength bands of the four-bolometer system are a narrow spectrum between 18 and 22 microns, and bands centered at 42, 70, and 140 microns. The responsivity and Johnson noise of the detectors limit the performance of the instrument.

Daneu, V.↗

Plug Load Management System Field Study: Wireless Meter and Controls

This presentation offers background on GSA's Green Proving Ground (GPG) and DOE's High Impact Technology (HIT) Catalyst work, and a field study that assessed a plug load management (PLM) system in two commercial building applications. The Ibis InteliNetwork (TM) PLM system enables users to measure and analyze device energy use and identify opportunities for reduction of plug load energy use, and set times for individual devices (or groups of devices) to turn off when not in use. The presentation gives an overview of the PLM demonstration project, its results, and lessons learned.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Cyber-Physical System for Freeway Ramp Meter Signal Control Using Deep Reinforcement Learning in a Connected Environment

Freeway bottlenecks such as on-ramp merging areas account for about 40% of recurring freeway congestion. It is generally agreed that building more roads and adding more lanes to existing infrastructure does not solve the congestion problem, and so dynamic traffic control measures offer a more cost-effective alternative. Ramp meters, traffic signal devices that regulate traffic flow entering freeways, are among the most effective measures to mitigate congestion at on-ramp merging areas on freeways. The confluence of deep reinforcement learning (RL) and connectivity provides a possible solution to advance ramp meter signal control. Deep RL is a group of machine-learning methods that enables an agent learning from the environment to improve its performance. In this study, three deep RL methods-proximal policy optimization (PPO), Ape-X deep Q-network (DQN), and asynchronous advantage actor-critic agents (A3C)-are explored for ramp meter signal control to maximize vehicle speed and traffic throughput, as well as to minimize energy consumption and emissions at freeway on-ramp merging areas in a connected environment. The low computational requirement and scalability of deep RL for deployment make it a powerful optimization tool for time-sensitive applications such as ramp meter signal control. The results of this study show that deep RL methods yield superior performance to both a fixed-time controller and ALINE A, a state-of-the-art feedback controller.

ADVANCED PROPULSION SYSTEMS,MATHEMATICS AND COMPUT↗

AN INTELLIGENT SENSOR FRAMEWORK FOR THE POWER GRID

The number of sensors connected to the electric power system is expected to grow by several orders of magnitude by 2020. However, the information networks which will transmit and analyze the resulting data are ill-equipped to handle the resulting volume with reliable real-time delivery. Without the ability to manage and use this data, deploying sensors such as phasor measurement units in the transmission system and smart meters in the distribution system will not result in the desired improvements in the power grid. The ability to exploit the massive data being generated by new sensors would allow for more efficient flow of power and increased survivability of the grid. Additionally, the power systems of today are not capable of managing two-way power flow to accommodate distributed generation capabilities due to concerns about system stability and lack of system flexibility. The research that we are performing creates a framework to add 'intelligence' to the sensors and actuators being used today in the electric power system. Sensors that use our framework will be capable of sharing information through the various layers of the electric power system to enable two-way information flow to help facilitate integration of distributed resources. Several techniques are considered including use of peer-to-peer communication as well as distributed agents.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distribution System Behind-the-Meter DERs: Estimation, Uncertainty Quantification, and Control

This paper summarizes the three-year technical activities of the IEEE Task Force (TF) on behind-the-meter (BTM) distributed energy resources (DERs): estimation, uncertainty quantification, and control. The potential grid services from BTM DERs are discussed in detail. The paper also reviews the state-of-the-art for BTM DERs visibility, uncertainty quantification, and, optimization and control. Furthermore, different aspects of the market structures associated with BTM DERs are covered, including emerging market and business models. Finally, needs and recommendations are provided for additional areas such as system protection, computing capabilities, algorithm development, market structure design, cyberinfrastructure and security, and hardware and software developments.

behind-the-meter↗

Evaluating Synthetic Smart Meter Locations For Communication System Modeling

An important part of good communication models for smart grid applications, particularly when wireless protocols are used, is the location information of the nodes. We’ve developed metrics to assist in evaluating whether a given model with such information is representative of feeders found in the world. These metrics are applied to a set of feeder models with known good location information for the smart meter locations and compared to a set of feeder models with similar location information that is not expected to be representative of real-world feeders. The comparison reveals that the suspect models do not pass statistical tests utilizing the developed metrics, providing initial validation of the analysis technique.

smart meter, feeder model, GridLAB-D↗

Fabrication end Deployment Testing of Meter Solar Sail Quadrants for a Scaleable Square Solar Sail Ground Test System

In order for solar sail propulsion technologies to be considered as a viable option for a wide range of near term practical missions a predictable, stable, reliable, manufactureable, scaleable, and cost effective system must be developed and tested first on earth and then on orbit. The design and development of a Scaleable Square Solar Sail System (S^4) is well underway a t AEC-Able Engineering Co. Inc., and the design and production of the Solar Sails for this system is being carried out by SRS Technologies. In April and May of 2004 a single quadrant 10-meter system was tested at NASA LARC's vacuum chamber and a four quadrant 20-meter system has been designed and built for deployment and testing in the Spring of 2005 at NASA/Glenn Research Center's Plumb Brook Facility. SRS has developed an effective and efficient design for triangular sail quadrants that are supported are three points and provide a flat reflective surface with a high fill factor. This sail design is robust enough for deployments in a one atmosphere, one gravity environment and incorporates several advanced features including adhesiveless seaming of membrane strips, compliant edge borders to allow for film membrane cord strain mismatch without causing wrinkling and low mass (3% of total sail mass) ripstop. This paper will outline the sail design and fabrication process, the lessons learned and the resulting mature production, packaging and deployment processes that have been developed. It will also highlight the scalability of the equipment and processes that were developed to fabricate and package the sails. Based on recent experience, SRS is confidant that flight worthy solar sails in the 40-120-meter size range with areal density in the 4-5g/sq m (sail minus structure) range can be produced with existing technology. Additional film production research will lead to further reductions in film thickness to less than 1 micron enabling production of sails with areal densities as low as 20 g/sq m using the current design resulting in a system areal density of as low as 5.3g/sq m. These areal densities are low enough to allow nearly all of the Solar Sail missions that have been proposed by the scientific community and the fundamental technology required to produce these sails has been demonstrated on the ground test sails that have recently been built. These demonstrations have shown that the technology is mature enough to build sails needed to support critical science missions. Solar Sails will be an enabling technology for NASA's Vision for Space Exploration by allowing communication satellite orbits that can maintain continuous communication with the polar regions of the Moon and Mars and to support solar weather monitoring to provide early warning of solar flares and storms that could threaten the safety of astronauts and other spacecraft.

Laue, Greg↗

Automatic inspection of analog and digital meters in a robot vision system

A critical limitation of most of the robots utilized in industrial environments arises due to their inability to utilize sensory feedback. This forces robot operation into totally preprogrammed or teleoperation modes. In order to endow the new generation of robots with higher levels of autonomy techniques for sensing of their work environments and for accurate and efficient analysis of the sensory data must be developed. In this paper detailed development of vision system modules for inspecting various types of meters, both analog and digital, encountered in a robotic inspection and manipulation tasks are described. These modules are tested using industrial robots having multisensory input capability.

Trivedi, Mohan M.↗

Design and test of a 2m x 4m DART system

A 2 meter by 4 meter DART (dual anamorphic reflector telescope) system has been designed and fabricated using thin stretched mesh reflectors. This report documents the structural configuration, test preparation, test results, and analysis correlation.

TPF Terrestrial Planet Finder life detection extra↗

Mining Smart Meter Data to Enhance Distribution Grid Observability for Behind-the-Meter Load Control: Significantly improving system situational awareness and providing valuable insights

Distributed Energy Resources (DERs) are playing an increasingly important role in power systems. In 2023, five categories of DERs-distributed solar, electric vehicles (EVs), energy storage, residential smart thermostats, and small-scale combined heat and power-are expected to contribute about 104 GW to the U.S. summer peak (see GTM, 2018). With the increasing integration of DERs in power distribution systems, distributed load control is imperative to smooth the fluctuations that they introduce. However, a main challenge is that distribution systems lack systematic situational awareness because of their limited sensors. Furthermore, most customer-level behind-the-meter (BTM) DERs, such as rooftop photovoltaics (PVs), are being integrated into distribution systems, which complicates the system monitoring and control. Furthermore, enhanced electric grid monitoring is needed to promote renewable integration while ensuring reliability, but current approaches rely on expensive sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Surface control system for the 15 meter hoop-column antenna

The 15-meter hoop-column antenna fabricated by the Harris Corporation under contract to the NASA Langley Research Center is described. The antenna is a deployable and restowable structure consisting of a central telescoping column, a 15-meter-diameter folding hoop, and a mesh reflector surface. The hoop is supported and positioned by 48 quartz cords attached to the column above the hoop, and by 24 graphite cords from the base of the antenna column. The RF reflective surface is a gold plated molybdenum wire mesh supported on a graphite cord truss structure which is attached between the hoop and the column. The surface contour is controlled by 96 graphite cords from the antenna base to the rear of the truss assembly. The antenna is actually a quadaperture reflector with each quadrant of the surface mesh shaped to produce an offset parabolic reflector. Results of near-field and structural tests are given. Controls structures and electromagnetics interaction, surface control system requirements, mesh control adjustment, surface control system actuator assembly, surface control system electronics, the system interface unit, and control stations are discussed.

Miller, James B.↗

Agent-Based Framework for Supporting Behind the Meter Transactive Power Electronic Systems

In this paper, the concept of a framework based on an agent-based interface for power stages in a power electronic system is presented. The presented concept or agent system is able to consider any number of different types of sources, types of converters, communication protocols, embedded decision making to support transactive, and hierarchy for large system integration. The concept is presented through several examples including the implementation on an actual physical system and demonstration of transactive type controls.

Starke, Michael↗