Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “material standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Pico-second laser materials interactions: mechanisms, material lifetime and performance optimization Ted Laurence(14-ERD-014)

Laser-induced damage with ps pulse widths straddles the transition from intrinsic, multiphoton ionization- and avalanche ionization-based ablation with fs pulses to defectdominated, thermal-based damage with ns pulses. We investigated the morphology and scaling of damage for commonly used silica and hafnia coatings as well as fused silica. Using carefully calibrated laser-induced damage experiments, in situ imaging, and high-resolution optical microscopy, atomic force microscopy, and scanning electron microscopy, we showed that defects play an important role in laser-induced damage for pulse durations as short as 1 ps. Three damage morphologies were observed: standard material ablation, ultra-high density pits, and isolated absorbers. For 10 ps and longer, the isolated absorbers limited the damage performance of the coating materials. We showed that damage resulting from the isolated absorbers grows dramatically with subsequent pulses for sufficient fluences. For hafnia coatings, we used electric field modeling and experiments to show that isolated absorbers near the surface were affected by the chemical environment (vacuum vs. air) for pulses as short as 10 ps. Coupled with the silica results, these results suggested that improvements in the performance in the 10 -60 ps range have not reached fundamental limits. These findings motivate new efforts, including a new SI LDRD in improving the laser-damage performance of multi-layer dielectric coatings. A damage test facility for ps pulses was developed and automated, and was used for testing production optics for ARC. The resulting software was transferred to other laser test facilities for fs pulses and multiple wavelengths with 30 ps pulses. Additionally, the LDRD supported the retention and promotion of an important staff scientist in high-resolution dynamic microscopy and laser-damage testing.

36 MATERIALS SCIENCE↗

Succinonitrile Purification Facility

The Succinonitrile (SCN) Purification Facility provides succinonitrile and succinonitrile alloys to several NRA selected investigations for flight and ground research at various levels of purity. The purification process employed includes both distillation and zone refining. Once the appropriate purification process is completed, samples are characterized to determine the liquidus and/or solidus temperature, which is then related to sample purity. The lab has various methods for measuring these temperatures with accuracies in the milliKelvin to tenths of milliKelvin range. The ultra-pure SCN produced in our facility is indistinguishable from the standard material provided by NIST to well within the stated +/- 1.5mK of the NIST triple point cells. In addition to delivering material to various investigations, our current activities include process improvement, characterization of impurities and triple point cell design and development. The purification process is being evaluated for each of the four vendors to determine the efficacy of each purification step. We are also collecting samples of the remainder from distillation and zone refining for analysis of the constituent impurities. The large triple point cells developed will contain SCN with a melting point of 58.0642 C +/- 1.5mK for use as a calibration standard for Standard Platinum Resistance Thermometers (SPRTs).

Source record↗

Toxicity of pyrolysis products: Influence of experimental conditions - The MSTL/UT and NASA/JSC Procedures

Ten sample materials of various polymeric composition were evaluated for toxicity of pyrolysis products utilizing two significantly different experimental methods, the MSTL/UT and NASA/JSC Procedures. A comparison of the LD(50) values obtained by the two methods for these ten samples did not yield a significant correlation. However, when the samples were ranked in order of increasing toxicity by each method independently, a comparison of their rank order toxicity improved the correlation. Because of interlaboratory variations in pyrolysis/combustion test procedures, it is suggested a series of standard materials be adopted to facilitate interlaboratory comparisons of data on pyrolysis toxicity.

Lawrence, W. H.↗

Diagnostic performance of magnetic resonance cholangiopancreatography (MRCP) versus endoscopic retrograde cholangiopancreatography (ERCP) in the pediatric population: a clinical effectiveness study

Purpose: To determine the diagnostic performance of magnetic resonance cholangiopancreatography (MRCP) for detecting biliary and pancreatic abnormalities in a pediatric population, using endoscopic retrograde cholangiopancreatography (ERCP) as the reference standard. Materials and methods: Institutional review board approval with a waiver of informed consent was obtained for this retrospective investigation. Records from the Cincinnati Children’s Hospital Medical Center, Division of Gastroenterology and Department of Radiology were used to identify patients aged ≤ 18 years who had undergone both ERCP and MRCP within a 4-week interval between January 2013 and May 2017. Biliary and pancreatic duct findings were documented for each modality to determine the diagnostic performance of MRCP (with 95% confidence intervals), using ERCP as the reference standard. Results: 54 patients met inclusion criteria. Mean patient age at time of ERCP was 10.4 ± 4.9 years, and 25 (46%) were male. Mean interval between ERCP and MRCP was 11.2 ± 9.7 days. For detection of any abnormality (n = 99 ERCP findings), MRCP had a sensitivity of 76.8% (67.5–84.0%) and a positive predictive value (PPV) of 81.7% (72.7–88.3%). MRCP was 75.7% (59.9–86.6%) sensitive, with a PPV of 84.9% (69.1–93.4%) for biliary findings (n = 37) and 73.5% (59.7–83.8%) sensitive, with a PPV of 78.3% (64.4–87.7%) for pancreatic findings (n = 49). For pancreatobiliary abnormalities (n = 13), MRCP had a sensitivity of 92.3% (66.7–99.6%) and a PPV of 85.7% (60.1–97.5%). Conclusion: In clinical practice, MRCP is moderately sensitive for biliary and pancreatic abnormalities, with false-negative and false-positive examinations being relatively common.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design Optimization for Printed Melt Wire Arrays Encapsulation

As part of the Nuclear Energy Enabling Technology (NEET) Advanced Sensor and Instrumentation (ASI) Program, Idaho National Laboratory (INL) has recently established in-house capabilities to fabricate and test new advanced-manufactured sensors for measuring peak irradiation temperature within a nuclear test reactor. Although methods of real-time temperature monitoring, such as thermocouples, may be used, the complexity of feedthroughs and attachments to collect real-time measurements greatly increases the cost of the experiment. Instead, passive monitoring techniques may be used for peak- temperature measurement that exploit the melting point of well-characterized materials (standard melt wires) to infer peak reactor temperatures. However, limited available space for instrumentation during experiments introduces an additional challenge. To accommodate this, INL has expanded its temperature- detection instrumentation capabilities to include advanced manufactured (AM) melt wires for peak irradiation temperature measurements. These melt wires can determine peak temperatures while also accommodate space limitations in irradiation experiments. In an effort to improve performance reliability of AM meltwire capabilities, a process was developed and tested to identify the significance of entrapping a high purity inert atmosphere within the packaging of printed melt wire arrays. The materials used in this study were aluminum, zinc, and tin encapsulated in high purity helium within a stainless steel (SS) 316 container. Tin, with a low melting point of approximately 230°C, Zn with a mid-melting point of approximately 420°C, and Al with a high melting point of approximately 660°C. This report describes the design, fabrication process, furnace testing and X-ray Computed Tomography (XCT) evaluation. Results show a successful outcome in creating an inert gas encapsulation and high-resolution evaluation methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrating crystallographic and computational approaches to carbon-capture materials for the mitigation of climate change

Here, this article presents an overview of the current state of the art in the structure determination of microporous carbon-capture materials, as discussed at the recent NIST workshop “Integrating Crystallographic and Computational Approaches to Carbon-Capture Materials for the Mitigation of Climate Change”. The continual rise in anthropogenic CO 2 concentration and its effect on climate change call for the implementation of carbon capture technologies to reduce the CO 2 concentration in the atmosphere. Porous solids, including metal–organic frameworks (MOFs), are feasible candidates for gas capture and storage applications. However, determining the structure of these materials represents a significant obstacle in their development into advanced sorbents. The existing difficulties can be overcome by integrating crystallographic methods and theoretical modeling. The workshop gathered experimentalists and theorists from academia, government, and industry to review this field and identify approaches, including collaborative opportunities, required to develop tools for rapid determination of the structures of porous solid sorbents and the effect of structure on the carbon capture performance. We highlight the findings of that workshop, especially in the need for reference materials, standardized procedures and reporting of sorbent activation and adsorption measurements, standardized reporting of theoretical calculations, and round-robin structure determination.

36 MATERIALS SCIENCE↗

Maximum Diameter Measurements of Aortic Aneurysms on Axial CT Images After Endovascular Aneurysm Repair: Sufficient for Follow-up?

Purpose: To assess the accuracy of maximum diameter measurements of aortic aneurysms after endovascular aneurysm repair (EVAR) on axial computed tomographic (CT) images in comparison to maximum diameter measurements perpendicular to the intravascular centerline for follow-up by using three-dimensional (3D) volume measurements as the reference standard. Materials and Methods: Forty-nine consecutive patients (73 {+-} 7.5 years, range 51-88 years), who underwent EVAR of an infrarenal aortic aneurysm were retrospectively included. Two blinded readers twice independently measured the maximum aneurysm diameter on axial CT images performed at discharge, and at 1 and 2 years after intervention. The maximum diameter perpendicular to the centerline was automatically measured. Volumes of the aortic aneurysms were calculated by dedicated semiautomated 3D segmentation software (3surgery, 3mensio, the Netherlands). Changes in diameter of 0.5 cm and in volume of 10% were considered clinically significant. Intra- and interobserver agreements were calculated by intraclass correlations (ICC) in a random effects analysis of variance. The two unidimensional measurement methods were correlated to the reference standard. Results: Intra- and interobserver agreements for maximum aneurysm diameter measurements were excellent (ICC = 0.98 and ICC = 0.96, respectively). There was an excellent correlation between maximum aneurysm diameters measured on axial CT images and 3D volume measurements (r = 0.93, P < 0.001) as well as between maximum diameter measurements perpendicular to the centerline and 3D volume measurements (r = 0.93, P < 0.001). Conclusion: Measurements of maximum aneurysm diameters on axial CT images are an accurate, reliable, and robust method for follow-up after EVAR and can be used in daily routine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tip Fence for Reduction of Lift-Generated Airframe Noise

The present invention is directed toward a unique lift-generated noise reduction apparatus. This apparatus includes a plurality of tip fences that are secured to the trailing and leading assemblies of the high-lift system, as close as possible to the discontinuities where the vortices are most likely to form. In one embodiment, these tip fences are secured to some or all of the outboard and inboard tips of the wing slats and flaps. The tip fence includes a generally flat, or an aerodynamically shaped plate or device that could be formed of almost any rigid material, such as metal, wood, plastic, fiber glass, aluminum, etc. In a preferred embodiment, the tip fences extend below and perpendicularly to flaps and the slats to which they are attached, such that these tip fences are aligned with the nominal free stream velocity of the aircraft. In addition to reducing airframe noise, the tip fence tends to decrease drag and to increase lift, thus improving the overall aerodynamic performance of the aircraft. Another advantage presented by the tip fence lies in the simplicity of its design, its elegance, and its ready ability to fit on the wing components, such as the flaps and the slats. Furthermore, it does not require non-standard materials or fabrication techniques, and it can be readily, easily and inexpensively retrofited on most of the existing aircraft, with minimal design changes.

Ross, James C.↗

Improved organic p-i-n type solar cells with n-doped fluorinated hexaazatrinaphthylene derivatives HATNA-F{sub 6} and HATNA-F{sub 12} as transparent electron transport material

We study new electron transport materials (ETM) to replace the reference material C{sub 60} in p-i-n type organic solar cells. A comprehensive material characterization is performed on two fluorinated hexaazatrinaphthylene derivatives, HATNA-F{sub 6} and HATNA-F{sub 12}, to identify the most promising material for the application in devices. We find that both HATNA derivatives are equally able to substitute C{sub 60} as ETM as they exhibit large optical energy gaps, low surface roughness, and sufficiently high electron mobilities. Furthermore, large electron conductivities of 3.5×10{sup −5} S/cm and 2.0×10{sup −4} S/cm are achieved by n-doping with 4 wt. % W{sub 2}(hpp){sub 4}. HOMO levels of (7.72 ± 0.05) eV and (7.73 ± 0.05) eV are measured by ultraviolet photoelectron spectroscopy and subsequently used for estimating LUMO values of (4.2 ± 0.8) eV and (4.3 ± 0.8) eV. Both fluorinated HATNA derivatives are successfully applied in p-i-n type solar cells. Compared to identical reference devices comprising the standard material C{sub 60}, the power conversion efficiency (PCE) can be increased from 2.1 % to 2.4 % by using the new fluorinated HATNA derivatives.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modular Design of High Temperature and Pressure Heat Exchangers Using 3D Printing

Functionally graded material (FGM), leveraged by latest additive manufacturing (AM) technologies, can add significant values to high temperature applications such as the HTR in supercritical sCO2 Brayton cycles. The project was focused on fabricating FGMs with complex geometries such as flow channels using DED and L-PBF technologies to support the modular design concept in achieving high-performance and low-cost high temperature recuperators for the sCO2 Brayton cycle. Samples printed from the base materials including both SS 316 and Inconel 625 have mostly met the material standards. L-PBF samples have achieved the fine feature sizes with good geometrical accuracy. In addition, DED has demonstrated its printability on LPBF part with both direct transition and using 50/50 mixed powders. Despite various challenging, the project helped advance the current state-of-the-art of DED technology in terms of printing fine geometries.

14 SOLAR ENERGY↗

Reflectance spectra measurement plan of captured samples from Ryugu: current status

Hayabusa2 spacecraft is equipped with Optical Navigation Camera (ONC) andNear-infrared Spectrometer (NIRS3), and has obtained reflectance spectra of the C-type near-Earth asteroid Ryugu over a wavelength range of 0.40–0.95 μm and 1.8–3.2 μm, respectively. It was revealed that Ryugu exhibits globally very low albedo (less than 0.02 at 0.55 and 2.0 μm), a slightly positive spectral slope, and an ubiquitous weak but sharp OH absorption band centered at 2.72 μm,showing a little regional heterogeneities. Thus, the surface material of Ryugu can be estimated as relatively similar to moderately heated carbonaceous chondrites, e.g., moderately dehydrated CI and CM, and enriched in carbon (Kitazato et al., 2019; Sugita et al., 2019; Tatsumi et al., 2020).Hayabusa2 successfully has performed twice touch down operations, and the captured sample will be brought back to the Earth in late 2020 (Morota et al., 2020; Tachibana et al., in preparation). To clarify Ryugu’s mineralogical and physicochemical properties and their varieties, effective for spectral characteristics obtained by ONC and NIRS3, several grains are planned to be distributed to several primary analysis groups. In this study, we report the current status of our spectral analysis plan in Hayabusa2 MINeralogy and PETrology of coarse grains (MIN-PET CG) team led by T. Nakamura, and the latest rehearsal analysis result using carbonaceous chondrite samples. MIN-PET CG rehearsal measurements have been performed to obtain detailed spectral properties of Ryugu grains with diverse spatial resolutions ranging from μm to mm scale or larger; using a few mm size polished CM sample with several microscopic imaging spectrometers covering various spatial range; with 200 μmor finer spatial resolution at Institut d’Astrophysique Spatiale, ~50 and 150 μm spatial resolution invisible and IR ranges at Brown University, and with 40 μm or larger spatial resolution at Tohoku University, and using mm-size CM and CI grains with a diffuse reflectance spectrometer with a few mm resolution at Tohoku University. Diffuse reflectance spectroscopy measurements undergo to use several mm-size CM or CI chondrite grains with Bruker VERTEX 70v, which covers ~0.38–15 μm in wavelength. To keep returned samples out of atmosphere avoiding any terrestrial contamination, wehave prepared an air shutoff cell to put samples and standard materials together kept in a N2 purged condition (Amano et al., 2020). Samples are Murchison CM chondrite showing typically ~5%reflectance with a strong OH absorption band at ~2.8 μm, and laboratory heated CI chondrite showing~3% reflectance, and a weak OH absorption band at ~2.7 μm. We will perform (1) fixed angle condition as laboratory standard setting at incident, emission, and phase angles of 30°, 0°, 30°, or 0°,30°, 30°, and (2) various angle conditions for photometric corrections. Future lab analyses of samples returned from Ryugu will provide direct and detailed information on the mineralogical and physicochemical properties of Ryugu, and relationship of spectral characteristics obtained by remote sensing and laboratory instruments.

M. Matsuoka↗

Phonon diffraction and dimensionality crossover in phonon-interface scattering

Abstract Thermal resistance at interfaces and grain boundaries is important in a range of fields from microelectronics to energy materials. Standard models treat interfaces as structureless even though at the nanoscale they are often better described as arrays of linear defects. Here, we examine several characteristics of heat transport that arise when considering such a structure at the interface. When heat carrying phonons scatter off linear defect arrays, diffraction of phonons occurs. Furthermore, a dimensionality crossover is observed in diffusive transport. Phonons transition from seeing a structureless planar defect when their wavelength is longer than the defect spacing, $$\lambda \gtrsim D$$ λ ≳ D , to seeing the interface as a collection of independently scattering linear defects when $$\lambda \lesssim D$$ λ ≲ D . By applying this theory to grain boundary strain-field scattering, we show that this dimensionality crossover can explain the frequency dependence of grain boundary scattering and transmissivity, which results in the T 2 temperature dependence observed in the low- T thermal conductivity of poly/nanocrystalline materials.

Hanus, Riley↗

Elastic-Plastic Thermal Stress Analysis of a High-Pressure Cryogenic Storage Tank

The thermal stresses on a cryogenic storage tank contribute strongly to the state of stress of the tank material and its ability to withstand operational stresses. These thermal stresses also affect the growth of any surface damage that might occur in the tank walls. These stresses are particularly of concern during the initial cooldown period for a new tank placed into service, and during any subsequent thermal cycles. A previous preliminary elastic analysis showed that the thermal stress on the inner wall would reach approximately 1,000MPa (145,000 psi). This stress far exceeds the ASTM specified room temperature values for both yield (170MPa) and ultimate (485 MPa) strength for 304L stainless steel. The present analysis determines the thermal stresses using an elastic-plastic model. The commercial software application ANSYS was used to determine the transient spatial temperature profile and the associated spatial thermal stress profiles in a segment of a thick-walled vessel during a typical cooldown process. A strictly elastic analysis using standard material properties for 304L stainless steel showed that the maximum thermal stress on the inner and outer walls was approximately 960 MPa (tensile) and - 270 MPa (compressive) respectively. These values occurred early in the cooldown process, but at different times, An elastic-plastic analysis showed significantly reducing stress, as expected due to the plastic deformation of the material. The maximum stress for the inner wall was approximately 225 MPa (tensile), while the maximum stress for the outer wall was approximately - 130 MPa (compressive).

Barker, J. Mark↗

Improving energy yield in photovoltaic modules with photonic structures

When installed outdoors, Si solar cells typically operate 20 – 30 K above ambient conditions. These elevated operating temperatures lead to diminished performance, reducing efficiency by ~0.4%/K for crystalline Si cells and decreasing module lifetime. Since much of the elevated temperature of the modules derives from parasitic absorption of sub-bandgap sunlight by the contacts, encapsulants, or other materials, reflectors that remove the sub-bandgap radiation from the module before it is absorbed promise to reduce the operating temperature. However, there are many competing strategies to reject this light: selective reflectors could be integrated into the outer module glass, at the textured Si-encapsulant interface, or on the rear. Furthermore, many of these approaches are complex and expensive to fabricate. The issue of heating can be even more critical in bifacial modules: high fractions of rear irradiance can lead to higher operating temperatures. Prior to this project, relatively little was known about the optical strategies for temperature reduction in bifacial modules. The goal of this project was to quantitatively assess optical strategies for improving the energy yield via a combination of improved anti-reflection and sub-bandgap light rejection. We studied two complementary concepts: the performance of ideal structures to determine the upper limits to performance, and low-complexity structures made from standard materials as cost-effective implementations. We also studied the performance of these reflectors in different types of modules, including Al BSF, PERC, and bifacial. Here we build from our prior accomplishments in developing mirror optimization techniques, and make use of simulation methods that accurately capture the optical properties of the modules throughout the visible and near-infrared spectrum. We connect these optical properties to energy yield under realistic, outdoor conditions. We also experimentally fabricated mirrors, incorporated them into mini-modules, and performed outdoor testing of performance at NREL. We found definitively that spectrally-selective mirrors on the outside of the module cover glass offer the best performance, both under ideal conditions and for realistic, low- complexity mirrors. Mirrors at the Si cell/encapsulant interface are limited by the multiple reflections needed to remove sub-bandgap light. Mirrors at the cell surface and mirrors on the rear also cannot remove all the sub-bandgap light, since parasitic absorption also occurs in the cover glass, encapsulant, and front contacts, depending on the module configuration. Also, cell texturing places higher demands on any cell-surface mirror because multiple interactions with the mirror are required to reject sub bandgap light which compounds losses. For bifacial modules, mirrors on the back do provide additional cooling and energy yield improvements, and the mirrors can have the same structure. In the monofacial case up to 3.3K of cooling is possible for mirrors on the front, compared to 2.2K at the cell surface and 1.2K at the rear. For bifacial modules, up to 2.4K of cooling is possible when mirrors are included at both the front and back. Our realistic designs utilize 4 – 6 layers of common photovoltaic materials such as SiO 2 , TiO 2 , and SiN x , making them more cost effective. Finally, we used our models to study thermal management in bifacial modules with different back lamination materials, finding that glass-glass laminated modules operated hotter than equivalent glass-polymer backsheet modules, due solely to the increased absorption of light incident from the rear of the module. Improving the energy yield by 2%, which is achievable with these realistic designs, would lead to LCOE reductions of $0.03/kWh by 2030. These benefits make photovoltaic panels more accessible to the public and may reduce associated maintenance costs.

14 SOLAR ENERGY↗

Advancing Risk Analysis for Nanoscale Materials: Report from an International Workshop on the Role of Alternative Testing Strategies for Advancement: Advancing Risk Analysis for Nanoscale Materials

The Society for Risk Analysis (SRA) has a history of bringing thought leadership to topics of emerging risk. In September 2014, the SRA Emerging Nanoscale Materials Specialty Group convened an international workshop to examine the use of alternative testing strategies (ATS) for manufactured nanomaterials (NM) from a risk analysis perspective. Experts in NM environmental health and safety, human health, ecotoxicology, regulatory compliance, risk analysis, and ATS evaluated and discussed the state of the science for in vitro and other alternatives to traditional toxicology testing for NM. Based on this review, experts recommended immediate and near-term actions that would advance ATS use in NM risk assessment. Three focal areas-human health, ecological health, and exposure considerations-shaped deliberations about information needs, priorities, and the next steps required to increase confidence in and use of ATS in NM risk assessment. The deliberations revealed that ATS are now being used for screening, and that, in the near term, ATS could be developed for use in read-across or categorization decision making within certain regulatory frameworks. Participants recognized that leadership is required from within the scientific community to address basic challenges, including standardizing materials, protocols, techniques and reporting, and designing experiments relevant to real-world conditions, as well as coordination and sharing of large-scale collaborations and data. Experts agreed that it will be critical to include experimental parameters that can support the development of adverse outcome pathways. Numerous other insightful ideas for investment in ATS emerged throughout the discussions and are further highlighted in this article.

36 MATERIALS SCIENCE↗

Comparing Calibration Algorithms for the Rapid Characterization of Pretreated Corn Stover Using Near-Infrared Spectroscopy

Rapid characterization of biomass composition is a key enabling technology for biorefineries—the ability to measure the chemical composition of biomass materials entering the biorefinery as well as the composition of key process intermediate streams would allow real-time process control and the development of robust models to predict process performance. The utility of near-infrared (NIR) spectroscopy for rapid characterization requires multivariate algorithms for building calibration models. The most prevalent algorithm used for building calibration models using NIR spectra is the linear modeling algorithm Partial Least Squares Regression (PLS). Nonlinear regression algorithms (which are typically more computationally intensive than linear modeling approaches) have gained popularity in recent years due to their ability to solve a wide variety of classification and regression problems and the dramatic increase in available computational resources. In this work, we demonstrate that a calibration model can predict the composition of corn stover process intermediate samples pretreated with three different treatments—hot water (HW), dilute acid (DA), and deacetylation followed by dilute acid (DDA). We quantitatively compare three different algorithms for building prediction models based on near-infrared spectroscopy—partial least squares (PLS), support vector machines (SVM), and random forests (RF). We demonstrate the utility of improving model performance by accounting for instrument performance variability using repeated measurements of standard materials (e.g., the “repeatability file” strategy) and investigate its performance with nonlinear regression techniques, and we discuss methods for quantifying the uncertainties of specific predictions among the three methods.

09 BIOMASS FUELS↗

Current Trends in the Treatment of Hepatocellular Carcinoma with Transarterial Embolization: Variability in Technical Aspects

Purpose: While transarterial chemoembolization (TACE) is a mainstay of treatment for unresectable hepatocellular carcinomas (HCCs), technical aspects have varied considerably in the literature. These variations lead to heterogeneity and make meaningful comparisons between articles difficult. The goal of this survey was to report international embolization practices for the treatment of HCC in an effort to understand current treatment strategies as a first step toward technique standardization. Materials and Methods: An anonymous 18 question online survey, evaluating technical aspects of TACE, was distributed via e-mail to practicing members of the five largest interventional radiology societies in Chinese and English. A total of 1160 responses were obtained from 62 countries. Results: Between regions, there were significant statistical differences in nearly all responses, including the amount of ethiodol oil used for cTACE (p = < 0.001). Practitioners most commonly used greater than 7.5 ml of ethiodol oil (240/506, 47.4%) and most did not utilize a specific mixing method (249/505, 49.3%). Particles utilized varied by geographical region (p = < 0.001), spherical embolic particles were slightly favored (363/757, 47.9%), followed closely by gelatin-based or sponge particles (279/680, 36.8%). Gelfoam was used almost exclusively in Japan and Korea (79/82 responses). LC/DC beads were the most commonly used drug-eluting bead (DEB) (450/742, 60.6%), with the most common size of DEB being 100–300 μm (354/690, 51.3%, p = 0.07). Conclusion: Technical aspects of transarterial embolization for HCC vary significantly by geographical location.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unique & challenging aspects of plutonium metal standards exchange program for actinide measurements

The Los Alamos National Laboratory exchange program is the only program of its kind for the distribution of plutonium (Pu) standards materials with a range of impurity contents to multiple laboratories for destructive measurements of elemental concentration. This paper discusses statistical methods used to address challenges in Pu metal exchange data by way of two case studies. Challenges include how to evaluate a data set when a large fraction of the values are minimum detection limits (MDLs), and how to determine potential outliers with limited in-formation on the true spread of the data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗