Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “map task”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

TU-AB-BRD-02: Failure Modes and Effects Analysis

Current quality assurance and quality management guidelines provided by various professional organizations are prescriptive in nature, focusing principally on performance characteristics of planning and delivery devices. However, published analyses of events in radiation therapy show that most events are often caused by flaws in clinical processes rather than by device failures. This suggests the need for the development of a quality management program that is based on integrated approaches to process and equipment quality assurance. Industrial engineers have developed various risk assessment tools that are used to identify and eliminate potential failures from a system or a process before a failure impacts a customer. These tools include, but are not limited to, process mapping, failure modes and effects analysis, fault tree analysis. Task Group 100 of the American Association of Physicists in Medicine has developed these tools and used them to formulate an example risk-based quality management program for intensity-modulated radiotherapy. This is a prospective risk assessment approach that analyzes potential error pathways inherent in a clinical process and then ranks them according to relative risk, typically before implementation, followed by the design of a new process or modification of the existing process. Appropriate controls are then put in place to ensure that failures are less likely to occur and, if they do, they will more likely be detected before they propagate through the process, compromising treatment outcome and causing harm to the patient. Such a prospective approach forms the basis of the work of Task Group 100 that has recently been approved by the AAPM. This session will be devoted to a discussion of these tools and practical examples of how these tools can be used in a given radiotherapy clinic to develop a risk based quality management program. Learning Objectives: Learn how to design a process map for a radiotherapy process Learn how to perform failure modes and effects analysis analysis for a given process Learn what fault trees are all about Learn how to design a quality management program based upon the information obtained from process mapping, failure modes and effects analysis and fault tree analysis. Dunscombe: Director, TreatSafely, LLC and Center for the Assessment of Radiological Sciences; Consultant to IAEA and Varian Thomadsen: President, Center for the Assessment of Radiological Sciences Palta: Vice President of the Center for the Assessment of Radiological Sciences.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRD-00: Task Group 100

Current quality assurance and quality management guidelines provided by various professional organizations are prescriptive in nature, focusing principally on performance characteristics of planning and delivery devices. However, published analyses of events in radiation therapy show that most events are often caused by flaws in clinical processes rather than by device failures. This suggests the need for the development of a quality management program that is based on integrated approaches to process and equipment quality assurance. Industrial engineers have developed various risk assessment tools that are used to identify and eliminate potential failures from a system or a process before a failure impacts a customer. These tools include, but are not limited to, process mapping, failure modes and effects analysis, fault tree analysis. Task Group 100 of the American Association of Physicists in Medicine has developed these tools and used them to formulate an example risk-based quality management program for intensity-modulated radiotherapy. This is a prospective risk assessment approach that analyzes potential error pathways inherent in a clinical process and then ranks them according to relative risk, typically before implementation, followed by the design of a new process or modification of the existing process. Appropriate controls are then put in place to ensure that failures are less likely to occur and, if they do, they will more likely be detected before they propagate through the process, compromising treatment outcome and causing harm to the patient. Such a prospective approach forms the basis of the work of Task Group 100 that has recently been approved by the AAPM. This session will be devoted to a discussion of these tools and practical examples of how these tools can be used in a given radiotherapy clinic to develop a risk based quality management program. Learning Objectives: Learn how to design a process map for a radiotherapy process Learn how to perform failure modes and effects analysis analysis for a given process Learn what fault trees are all about Learn how to design a quality management program based upon the information obtained from process mapping, failure modes and effects analysis and fault tree analysis. Dunscombe: Director, TreatSafely, LLC and Center for the Assessment of Radiological Sciences; Consultant to IAEA and Varian Thomadsen: President, Center for the Assessment of Radiological Sciences Palta: Vice President of the Center for the Assessment of Radiological Sciences.

60 APPLIED LIFE SCIENCES↗

Informative Path Planning for Mapping Radiation

This project involves making measurements of contaminated areas using portable radiation detectors and small robots. Tasks involve operating detectors and small robots, combining data acquisition for the two systems, and automating the systems. The end result is a radiation map of contamination areas. Localization of radioactive sources and mapping of contamination distribution is essential when responding to emergencies, or when dealing with cleanup efforts. Radiation maps are used for situational awareness and for establishing a safe perimeter. However, it may be hazardous or impossible for humans to safely enter the site and survey the area. Informative Path Planning (IPP) is used to design a path for a robotic sensor platform to gather the most information about the radiation distribution while operating under the set of constraints given by the dynamics of the robot and other requirements such as minimizing the overall mission time. The key challenge for IPP is the tight coupling in multiple layers of decisions: Selection of locations to visit; Allocation of sensors to those locations; Processing of information gathered. Given a robot equipped with a basic gamma detector and Lidar sensor, how can we efficiently explore an unknown environment in such a way that we can satisfy the robot's constraints while simultaneously maximizing the accuracy of the map and minimizing the total runtime? This work presents a systematic procedure for IPP and environmental mapping that: Selects the best locations at which to sample; Finds the best path for robots; Estimates the measurement value at unknown locations using a Gaussian Process regression framework. Given a set of points where radiation measurements were taken, we are utilizing a Gaussian Process Regression with a Matern kernel to reconstruct the shape of the underlying ground truth. Mapping is done via the Robot Operating System's OpenSlam Gmapping package, which creates a 2D occupancy grid map. Simulated trials were run with a radiation source placed at random locations, and allowing the robot to select and move towards 20 samples at separate locations, as well as sampling along the path while moving. The simulated sensor model assumed an efficiency of 0.3, collection time of 1 second. Various weighting schemes were tested and compared. Quantitative evaluations often favored exploitation-heavy weighting schemes where μ was emphasized, with the Root Mean Squared Error (RMSE) quickly tending towards 2, whereas qualitative comparisons would favor exploration-biased schemes with greater weight on σ. The difference comes from operators often favoring knowing the general location of a source, rather than the exact properties of a source. Weighting of the path-length π often reduced the quality of the regression as less exploration occurred, however this may be deemed a worthwhile trade-off under certain circumstances, such as with sensitive robots. Successfully developed a methodology for informative path-planning for a robot to efficiently gather information and create a map of radiation. In the future, we would like to focus on: Hardware trials with integration of the robot platform and the IPP software; More refined sensor and environmental modeling; Multiple robot platforms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Task-based detectability in CT image reconstruction by filtered backprojection and penalized likelihood estimation

Purpose: Nonstationarity is an important aspect of imaging performance in CT and cone-beam CT (CBCT), especially for systems employing iterative reconstruction. This work presents a theoretical framework for both filtered-backprojection (FBP) and penalized-likelihood (PL) reconstruction that includes explicit descriptions of nonstationary noise, spatial resolution, and task-based detectability index. Potential utility of the model was demonstrated in the optimal selection of regularization parameters in PL reconstruction. Methods: Analytical models for local modulation transfer function (MTF) and noise-power spectrum (NPS) were investigated for both FBP and PL reconstruction, including explicit dependence on the object and spatial location. For FBP, a cascaded systems analysis framework was adapted to account for nonstationarity by separately calculating fluence and system gains for each ray passing through any given voxel. For PL, the point-spread function and covariance were derived using the implicit function theorem and first-order Taylor expansion according toFessler [“Mean and variance of implicitly defined biased estimators (such as penalized maximum likelihood): Applications to tomography,” IEEE Trans. Image Process. 5(3), 493–506 (1996)]. Detectability index was calculated for a variety of simple tasks. The model for PL was used in selecting the regularization strength parameter to optimize task-based performance, with both a constant and a spatially varying regularization map. Results: Theoretical models of FBP and PL were validated in 2D simulated fan-beam data and found to yield accurate predictions of local MTF and NPS as a function of the object and the spatial location. The NPS for both FBP and PL exhibit similar anisotropic nature depending on the pathlength (and therefore, the object and spatial location within the object) traversed by each ray, with the PL NPS experiencing greater smoothing along directions with higher noise. The MTF of FBP is isotropic and independent of location to a first order approximation, whereas the MTF of PL is anisotropic in a manner complementary to the NPS. Task-based detectability demonstrates dependence on the task, object, spatial location, and smoothing parameters. A spatially varying regularization “map” designed from locally optimal regularization can improve overall detectability beyond that achievable with the commonly used constant regularization parameter. Conclusions: Analytical models for task-based FBP and PL reconstruction are predictive of nonstationary noise and resolution characteristics, providing a valuable framework for understanding and optimizing system performance in CT and CBCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multilevel Semantic Labeling of Mobile Homes from Overhead Imagery

Finding where people live and the vulnerabilities of man-made facilities during natural disasters, is not only critical for rescue efforts, but also essential for damage assessment in the aftermath. Leveraging on the availability of high resolution satellite imagery, advances in machine learning and high performance computing hardware, it is now possible to generate geographical maps for man-made facilities at scale. Mapping from satellite imagery can be a daunting task due to the enormous amount of data to be processed over large areas. In this short paper we take advantage of annotated satellite imagery and automate the semantic labeling of mobile home parks using an efficient framework rooted in patch-based and pixel-level classification. This multilevel labeling effort is a precursor to our future goal for deploying very large scale deep convolutional neural networks toward both broad and finer characterization of man-made structures from one-meter resolution NAIP images.

Lunga, Dalton↗

Component-Level Inverse Design of Transmon Qubits Using Neural Networks

Designing a superconducting qubit to realize specific Hamiltonian parameters typically requires iterating through a time and compute-intensive forward loop in which the designer chooses a layout geometry, simulates it, extracts circuit parameters such as capacitances, and refines the geometry. We study the inverse version of this task using a neural-network workflow that maps target Hamiltonian parameters directly to component-level layout parameters, which we subsequently demonstrate on a planar transmon layout. During training, we pair the inverse model with a frozen forward surrogate model and evaluate the loss in Hamiltonian space rather than in layout-parameter space. In validation against a conventional EM solver, 97% of generated designs produce usable geometries, and the inverse-plus-surrogate pipeline reaches mean percent errors of 0.73% for qubit frequency and 1.58% for anharmonicity, comparable to or below the fabrication and simulation-to-measurement uncertainty expected for academic-process transmon devices of this type. A single pipeline query takes ~60 ms on CPU, versus ~2 min for a conventional EM capacitance extraction on the same hardware, a speedup of approximately 2,000x. Batching minimizes the AI model inference overhead, reducing the runtime to 3.1 microseconds per sample on CPU and 2.6 microseconds per sample on GPU at a batch size of 2048, resulting in speedups of 3.9 x 10^7 and 4.6 x 10^7, respectively, relative to a single conventional CPU EM extraction. Our results indicate that component-level inverse design usefully extends and complements conventional EM simulation, including for small datasets on the order of 1,000 samples.

Seidel, Olivia [Fermilab; Texas U., Arlington]↗

How training and experience affect the benefits of autonomy in a dirty-bomb experiment

A dirty-bomb experiment conducted at the INL is used to evaluate the effectiveness and suitability of three different modes of robot control. The experiment uses three distinct user groups to understand how participants’ background and training affect the way in which they use and benefit from autonomy. The results show that the target mode, which involves automated mapping and plume tracing together with a point and click tasking tool, provides the best performance for each group. This is true for objective performance such as source detection and localization accuracy as well as subjective measures such as perceived workload, frustration and preference. The best overall performance is achieved by the Explosive Ordinance Disposal group which has experience in both robot teleoperation and dirty bomb response. The user group that benefits least from autonomy is the Nuclear Engineers that have no experience with either robot operation or dirty bomb response. The group that benefits most from autonomy is the Weapons of Mass Destruction Civil Response Team that has extensive experience related to the task, but no robot training.

99 GENERAL AND MISCELLANEOUS↗

Thermochemical Data Fusion Using Graph Representation Learning

Large databases are required for “Big Data” applications in catalysis and materials science. Thermochemical databases can be created by combining data from various sources and by correcting low-fidelity datasets to higher accuracy with minimal computation. To achieve this “data fusion”, thermochemical quantities of interest, calculated at various levels of density functional theory (DFT), need to be mapped to the same, high levels of theory. In this work, a graph theoretical, statistical framework is proposed for such tasks. Subgraph frequencies are shown to provide a natural representation for learning these fusion maps. The maps are linear and are learnt with automated descriptor selection. Using a dataset of as few as ~1% from the QM9 database of 133,885 molecules, these models can predict multiple thermochemical quantities at a higher level of theory with an accuracy of 1 kcal/mol. Here, the method is explainable, generalizable, and provides a diagnostic tool for outlier identification

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Potosi Reservoir Modeling; History and Recommendations

As a part of a larger project co-funded by the United States Department of Energy (US DOE) to evaluate the potential of formations within the Cambro-Ordovician strata above the Mt. Simon as potential targets for carbon sequestration in the Illinois and Michigan Basins, the Illinois Clean Coal Institute (ICCI) requested Schlumberger to evaluate the potential injectivity and carbon dioxide (CO₂) plume size of the Cambrian Potosi Formation. The evaluation of this formation was accomplished using wireline data, core data, pressure data, and seismic data from two projects: the US DOE-funded Illinois Basin–Decatur Project being conducted by the Midwest Geological Sequestration Consortium in Macon County, Illinois, as well as data from the Illinois – Industrial Carbon Capture and Sequestration (IL-ICCS) project funded through the American Recovery and Reinvestment Act. In 2010, technical performance evaluations on the Cambrian Potosi Formation were performed through reservoir modeling. The data included formation tops from mud logs, well logs from the Verification Well 1 (VW1) and the Injection Well (CCS1), structural and stratigraphic formation from three dimensional (3D) seismic data, and field data from several waste water injection wells for the Potosi Formation. The intention was for two million tonnes per annum (MTPA) of CO₂ to be injected for 20 years into the Potosi Formation. In 2013, updated reservoir models for the Cambrian Potosi Formation were evaluated. The data included formation tops from mud logs, well logs from the CCS1, VW1, and Verification Well 2 (VW2) wells, structural and stratigraphic formation from a larger 3D seismic survey, and field data from several waste water injection wells for Potosi Formation. The objective is to simulate the injection of CO₂ at a rate 3.5 million tons per annum (3.2 million tonnes per annum [MTPA]) for 30 years 106 million tons (96 MT total) into the Potosi Formation. The Potosi geomodeling efforts have evolved from using data from a single well in 2010 to the inclusion of data from three wells in 2013 which largely leverage the porosity and permeability logs plus knowledge of lost circulation zones. The first Potosi model (Potosi Geobody Model 2010) attempted to use the available seismic inversion data to inform the geomodel and predict vugular zones in advance of drilling VW1. Lost circulation zones in VW1 came in as the geologists predicted. The model was not implemented in subsequent simulation work. To date, reservoir models used for flow simulation work have relied predominately on Gaussian distributed properties (porosity and permeability) and have employed a single injection well. Potosi Model 2013b incorporated the new VW2 logs, and exhibited an extra level of sophistication by delineating the vugular intervals. This method added further realism that likely represents the best reservoir approximation to date. Where the 2010 reservoir models were 10 by 10 mi (16 by 16 km) in area, the 2013 models were expanded in size to 30 by 30 mi (48 by 48 km). The latest reservoir simulations show that a minimum of four injectors might be required to meet target injection rates. Still, there is data that requires further scrutiny and modeling methodologies that require testing for the Potosi Formation. This work is currently ongoing, and the next phase of the reservoir modeling intends to implement valuable data like porosity derived from seismic inversion, seismically derived geobodies, or a combination of both to further define vugular zones and the porosity distribution within the Potosi Formation. Understanding the dual porosity, dual permeability character of the Potosi remains the greatest challenge in representing this formation. Further analysis of the FMI* fullbore formation microimager data may aid in assessing this uncertainty. The Potosi Formation is indeed an interesting formation, and recommendations to further characterize it are included in the following list: - Data acquisition to identify the vugs permeability, distribution, and interconnectivity could be considered to perform a more rigorous evaluation of the Potosi Formation injectivity and capacity. This could be achieved by performing an injection test on a vugular interval to determine the vugs permeability, and an interference test between wells to evaluate the local vugs extent and interconnectivity. - A thorough study of the available FMI data may reveal specifics on estimating the vug to matrix ratio. This estimate could be used to further condition the porosity distribution. Porosity logs alone might underestimate the formation’s porosity associated with vugs. Porosity mapping derived from the seismic inversion could also be used in the succeeding task to characterize the lateral porosity distribution within the reservoir. This could involve the geobody methodology previously attempted in 2010. With or without seismic inversion porosity mapping, it is worth exploring whether increased lateral heterogeneity plays a significant role in Potosi injectivity. Investigations on vugular, dolomitic outcrops suggest that there may be significantly greater lateral heterogeneity than what has been modeled here. - The FMI data also reveals the presence of and helps describe open fractures. The presence of fractures will further enhance the formation’s permeability. The task of leveraging this data in the geomodeling effort still remains. Under the best of circumstances, this data describing open fractures may be combined with seismic attributes to delineate fracture corridors. Fracture modeling would certainly add another layer of sophistication to the model. Its contribution and applicability remain to be explored. - Facies modeling within the Potosi has yet to be thoroughly addressed. The carbonates during the time of deposition are believed to be regionally extensive. However, it may be worth delineating the reservoir with other regional wells or modern day analogues to understand the extent of the Potosi. More specifically, the model could incorporate lateral changes or trends if deemed necessary to represent facies transition. - Currently there is no fracture gradient data available for the Potosi in the Decatur project area. The acquisition of the fracture pressure data could be considered to determine an appropriate maximum allowable bottomhole injection pressure. This would allow the evaluation of injectivity and the required number of wells in a more precise manner. - Special core analysis (SCAL) to determine the relative permeability and capillary pressure of the vugs and matrix could be considered to have a better estimation of the reservoir injectivity and plume extent. - Formation water sampling and analysis could be considered for the Potosi to estimate the water salinity and properties. A vertical flow performance evaluation could be considered for the succeeding task to determine the appropriate tubing size, the required injection tubing head pressure, and to investigate whether the corresponding well injection rate falls within the tubing erosional velocity limit. - A simulation using several injectors could also be considered to determine the required number of wells to achieve the injection target while taking into account the pressure interference.

Smith, Valerie↗

Multiview Incomplete Knowledge Graph Integration with application to cross-institutional EHR data harmonization

Objective: The growing availability of electronic health records (EHR) data opens opportunities for integrative analysis of multi-institutional EHR to produce generalizable knowledge. A key barrier to such integrative analyses is the lack of semantic interoperability across different institutions due to coding differences. We propose a Multiview Incomplete Knowledge Graph Integration (MIKGI) algorithm to integrate information from multiple sources with partially overlapping EHR concept codes to enable translations between healthcare systems. Methods: The MIKGI algorithm combines knowledge graph information from (i) embeddings trained from the co-occurrence patterns of medical codes within each EHR system and (ii) semantic embeddings of the textual strings of all medical codes obtained from the Self-Aligning Pretrained BERT (SAPBERT) algorithm. Due to the heterogeneity in the coding across healthcare systems, each EHR source provides partial coverage of the available codes. MIKGI synthesizes the incomplete knowledge graphs derived from these multi-source embeddings by minimizing a spherical loss function that combines the pairwise directional similarities of embeddings computed from all available sources. MIKGI outputs harmonized semantic embedding vectors for all EHR codes, which improves the quality of the embeddings and enables direct assessment of both similarity and relatedness between any pair of codes from multiple healthcare systems. Results: With EHR co-occurrence data from Veteran Affairs (VA) healthcare and Mass General Brigham (MGB), MIKGI algorithm produces high quality embeddings for a variety of downstream tasks including detecting known similar or related entity pairs and mapping VA local codes to the relevant EHR codes used at MGB. Based on the cosine similarity of the MIKGI trained embeddings, the AUC was 0.918 for detecting similar entity pairs and 0.809 for detecting related pairs. For cross-institutional medical code mapping, the top 1 and top 5 accuracy were 91.0% and 97.5% when mapping medication codes at VA to RxNorm medication codes at MGB; 59.1% and 75.8% when mapping VA local laboratory codes to LOINC hierarchy. When trained with 500 labels, the lab code mapping attained top 1 and 5 accuracy at 77.7% and 87.9%. MIKGI also attained best performance in selecting VA local lab codes for desired laboratory tests and COVID-19 related features for COVID EHR studies. Compared to existing methods, MIKGI attained the most robust performance with accuracy the highest or near the highest across all tasks. Conclusions: The proposed MIKGI algorithm can effectively integrate incomplete summary data from biomedical text and EHR data to generate harmonized embeddings for EHR codes for knowledge graph modeling and cross-institutional translation of EHR codes.

Zhou, Doudou↗

Accuracy Analysis of a Robotic Radionuclide Inspection and Mapping System for Surface Contamination

The mapping of localized regions of radionuclide contamination in a building can be a time consuming and costly task. Humans moving hand-held radiation detectors over the target areas are subject to fatigue. A contamination map based on manual surveys can contain significant operator-induced inaccuracies. A Fanuc M16i light industrial robot has been configured for installation on a mobile aerial work platform, such as a tall forklift. When positioned in front of a wall or floor surface, the robot can map the radiation levels over a surface area of up to 3 m by 3 m. The robot's end effector is a commercial alpha-beta radiation sensor, augmented with range and collision avoidance sensors to ensure operational safety as well as to maintain a constant gap between surface and radiation sensors. The accuracy and repeatability of the robotically conducted contamination surveys is directly influenced by the sensors and other hardware employed. This paper presents an in-depth analysis of various non-contact sensors for gap measurement, and the means to compensate for predicted systematic errors that arise during the area survey scans. The range sensor should maintain a constant gap between the radiation counter and the surface being inspected. The inspection robot scans the wall surface horizontally, moving down at predefined vertical intervals after each scan in a meandering pattern. A number of non-contact range sensors can be employed for the measurement of the gap between the robot end effector and the wall. The nominal gap width was specified as 10 mm, with variations during a single scan not to exceed {+-} 2 mm. Unfinished masonry or concrete walls typically exhibit irregularities, such as holes, gaps, or indentations in mortar joints. These irregularities can be sufficiently large to indicate a change of the wall contour. The responses of different sensor types to the wall irregularities vary, depending on their underlying principles of operation. We explored capacitive, ultrasound, and optical Laser range sensors. The unshielded capacitive range sensors were found to be influenced by objects in their vicinity, and to have comparatively low sensitivity. Therefore they were not used for gap measurement. We did, however, use them successfully to detect obstacles in the field of motion of the sensor head. The four sensors pointing diagonally from four corners of the sensor head are capacitive range sensors, which stop the robot motion any time a pre-set threshold signal level is exceeded. Ultrasound range sensors were found to have good resolution. The ultrasound beam was frequently deflected sideways by the wall's roughness, resulting in a spurious signal peaks. On the other hand, ultrasound signals are inherently insensitive to variations of the optical surface properties. Laser range sensing proved to be generally less noisy than ultrasound measurements. The aforementioned sensitivity to the target surface's optical properties was not evident on grey, non-reflective surfaces. On such surfaces, laser range sensing was found to be superior to ultrasound measurements. Occasionally, however, surface reflectivity and specularity caused erroneous measurements. The computational burden of measuring and filtering the sensor data in real time made it impractical to control the robot directly based on sensor feedback. The robot performs a first horizontal surface range scan merely to gage the surface profile. During the subsequent passes, the robot records the radiation measurements, while recording the range data for the next pass, with the range sensor positioned below the radiation sensor. The decoupling of measurements from robot control prevents the robot controller from responding to spurious sensor signals, ensuring steadier and safer radiation surveying. The controller is configured to accept either optical or ultrasound range signals, so as to respond better to user-specific requirements. A detailed analysis of non-contact range sensors and control for the automated mapping of surface contamination has been presented. The Contamination Survey Machine was tested and is operational.

42 ENGINEERING↗

Imaging crossing fibers in mouse, pig, monkey, and human brain using small-angle X-ray scattering

Myelinated axons (nerve fibers) efficiently transmit signals throughout the brain via action potentials. Multiple methods that are sensitive to axon orientations, from microscopy to magnetic resonance imaging, aim to reconstruct the brain's structural connectome. As billions of nerve fibers traverse the brain with various possible geometries at each point, resolving fiber crossings is necessary to generate accurate structural connectivity maps. However, doing so with specificity is a challenging task because signals originating from oriented fibers can be influenced by brain (micro)structures unrelated to myelinated axons. X-ray scattering can specifically probe myelinated axons due to the periodicity of the myelin sheath, which yields distinct peaks in the scattering pattern. Here, in this work, we show that small-angle X-ray scattering (SAXS) can be used to detect myelinated, axon-specific fiber crossings. We first demonstrate the capability using strips of human corpus callosum to create artificial double- and triple-crossing fiber geometries, and we then apply the method in mouse, pig, vervet monkey, and human brains. We compare results to polarized light imaging (3D-PLI), tracer experiments, and to outputs from diffusion MRI that sometimes fails to detect crossings. Given its specificity, capability of 3-dimensional sampling and high resolution, SAXS could serve as a ground truth for validating fiber orientations derived using diffusion MRI as well as microscopy-based methods.

59 BASIC BIOLOGICAL SCIENCES↗

WE-H-BRC-04: Implement Lean Methodology to Make Our Current Process of CT Simulation to Treatment More Efficient

Purpose: Our goal is to implement lean methodology to make our current process of CT simulation to treatment more efficient. Methods: In this study, we implemented lean methodology and tools and employed flowchart in excel for process-mapping. We formed a group of physicians, physicists, dosimetrists, therapists and a clinical physics assistant and huddled bi-weekly to map current value streams. We performed GEMBA walks and observed current processes from scheduling patient CT Simulations to treatment plan approval. From this, the entire workflow was categorized into processes, sub-processes, and tasks. For each process we gathered data on touch time, first time quality, undesirable effects (UDEs), and wait-times from relevant members of each task. UDEs were binned per frequency of their occurrence. We huddled to map future state and to find solutions to high frequency UDEs. We implemented visual controls, hard stops, and documented issues found during chart checks prior to treatment plan approval. Results: We have identified approximately 64 UDEs in our current workflow that could cause delays, re-work, compromise the quality and safety of patient treatments, or cause wait times between 1 – 6 days. While some UDEs are unavoidable, such as re-planning due to patient weight loss, eliminating avoidable UDEs is our goal. In 2015, we found 399 issues with patient treatment plans, of which 261, 95 and 43 were low, medium and high severity, respectively. We also mapped patient-specific QA processes for IMRT/Rapid Arc and SRS/SBRT, involving 10 and 18 steps, respectively. From these, 13 UDEs were found and 5 were addressed that solved 20% of issues. Conclusion: We have successfully implemented lean methodology and tools. We are further mapping treatment site specific workflows to identify bottlenecks, potential breakdowns and personnel allocation and employ tools like failure mode effects analysis to mitigate risk factors to make this process efficient.

60 APPLIED LIFE SCIENCES↗

A Flexible Field Mapping System for Accelerator Magnets

Magnetic field mapping is a fundamental magnetic measurement method that typically uses Hall and NMR sensors. In magnet measurement facilities, such systems are likely used in various configurations suitable for a specific task at hand. To address this diversity, the authors developed a flexible field mapping system capable of being configured and tailored to each particular measurement case. Further, the system needs to address the variability introduced by differences in sensors and their readout systems, probe positioning systems, power supply systems, and required mapping geometry (mapping space and grid, measurement steps and sequences). Although the discussed field mapping systems range from a self-propelled multi-sensor mapper of a large detector magnet to a single 3D Hall sensor system to scan a small permanent magnet, they were all built with the same core mapping system. The variability present in field mapping systems, the measurement system architecture addressing this variability, as well as examples of several field mapping systems built in this architecture are presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Flexible Field Mapping System for Accelerator Magnets

Magnetic field mapping is a fundamental magnetic measurement method that typically uses Hall and NMR sensors. In magnet measurement facilities, such systems are likely used in various configurations suitable for a specific task at hand. To address this diversity, the authors developed a flexible field mapping system capable of being configured and tailored to each particular measurement case. The system needs to address the variability introduced by differences in sensors and their readout systems, probe positioning systems, power supply systems and in required mapping geometry (mapping space and grid, measurement steps and sequences). Although the discussed field mapping systems range from a self-propelled, multi-sensor mapper of a large detector magnet to a single 3D Hall sensor system to scan a small permanent magnet, they were all built with the same core mapping system. The variability present in field mapping systems and the measurement system architecture addressing this variability, as well as examples of several field mapping systems built in this architecture are presented.

43 PARTICLE ACCELERATORS↗

Automated tape-target centering based on template matching for construction measurement tasks using robotic total station

Robotic total stations have transformed surveying and construction mapping through precise, efficient, and automated measurements. These instruments integrate a theodolite, which measures horizontal and vertical angles, with an electronic distance measurement (EDM) unit to determine distances, allowing accurate 3D measurement of observable points. Traditionally, users manually aimed the total station at a target. Recent advancements in robotic motor control and integration of cameras now enable automatic rotation and aiming, typically requiring only a single operator to position the target. Automated aiming is commonly performed using retroreflector prisms, which reflect light back to the source with minimal scattering, enabling high-precision measurements over long distances. However, retroreflectors, especially those designed for 360 degree, can be expensive and impractical for certain applications. This paper presents an algorithm for automating the center detection of low-cost disposable tape targets using the total station's onboard camera and a template matching algorithm. The algorithm identifies the target's center pixel in the image, and the instrument is commanded to aim at that location. We evaluated the performance of this template-matching-based centering method under various distances, angles, lighting conditions, and field environments, comparing its results to both manual aiming and conventional automated aiming of tape targets. Manual aiming was used as the baseline operational reference in the absence of an independent ground-truth measurement. The proposed approach achieves target centering results comparable to the manual baseline. This method provides a cost-effective alternative for high-precision applications where retroreflector targets are constrained by budget or logistics.

Harrington, Joshua [ORNL]↗

Platform Agnostic Streaming Data Application Performance Models

The mapping of computational needs onto execution resources is, by and large, a manual task, and users are frequently guided simply by intuition and past experiences. We present a queueing theory based performance model for streaming data applications that takes steps towards a better understanding of resource mapping decisions, thereby assisting application developers to make good mapping choices. The performance model (and associated cost model) are agnostic to the specific properties of the compute resource and application, simply characterizing them by their achievable data throughput. We illustrate the model with a pair of applications, one chosen from the field of computational biology and the second is a classic machine learning problem.

Faber, Clayton↗