New Active Optical Technique Developed for Measuring Low-Earth-Orbit Atomic Oxygen Erosion of Polymers

Polymers such as polyimide Kapton (DuPont) and Teflon FEP (DuPont, fluorinated ethylene propylene) are commonly used spacecraft materials because of desirable properties such as flexibility, low density, and in the case of FEP, a low solar absorptance and high thermal emittance. Polymers on the exterior of spacecraft in the low-Earth-orbit (LEO) environment are exposed to energetic atomic oxygen. Atomic oxygen reaction with polymers causes erosion, which is a threat to spacecraft performance and durability. It is, therefore, important to understand the atomic oxygen erosion yield E (the volume loss per incident oxygen atom) of polymers being considered in spacecraft design. The most common technique for determining E is a passive technique based on mass-loss measurements of samples exposed to LEO atomic oxygen during a space flight experiment. There are certain disadvantages to this technique. First, because it is passive, data are not obtained until after the flight is completed. Also, obtaining the preflight and postflight mass measurements is complicated by the fact that many polymers absorb water and, therefore, the mass change due to water absorption can affect the E data. This is particularly true for experiments that receive low atomic oxygen exposures or for samples that have a very low E. An active atomic oxygen erosion technique based on optical measurements has been developed that has certain advantages over the mass-loss technique. This in situ technique can simultaneously provide the erosion yield data on orbit and the atomic oxygen exposure fluence, which is needed for erosion yield determination. In the optical technique, either sunlight or artificial light can be used to measure the erosion of semitransparent or opaque polymers as a result of atomic oxygen attack. The technique is simple and adaptable to a rather wide range of polymers, providing that they have a sufficiently high optical absorption coefficient. If one covers a photodiode with a uniformly thick sheet of semitransparent polymer such as Kapton H polyimide, then as atomic oxygen erodes the polymer, the short-circuit current from the photodiode will increase in an exponential manner with fluence. This nonlinear response with fluence results in a lack of sensitivity for measuring low atomic oxygen fluences. However, if one uses a variable-thickness polymer or carbon sample, which is configured as shown in the preceding figure, then a linear response can be achieved for opaque materials using a parabolic well for a circular geometry detector or a V-shaped well for a rectangular-geometry detector. Variable-thickness samples can be fabricated using many thin polymer layers. For semitransparent polymers such as Kapton H polyimide, there is an initial short-circuit current that is greater than zero. This current has a slightly nonlinear dependence on atomic oxygen fluence in comparison to opaque materials such as black Kapton as shown in the graph. For this graph figure, the total thickness of Kapton H was assumed to be 0.03 cm. The photodiode short-circuit current shown in the graph was generated on the basis of preliminary measurements-a total reflectance rho of 0.0424 and an optical absorption coefficient a of 146.5 cm(sup -1). In addition to obtaining on-orbit data, the advantage of this active erosion and erosion yield measurement technique is its simplicity and reliance upon well-characterized fluence witness materials as well as a nearly linear photodiode short-circuit current dependence upon atomic oxygen fluence. The optical technique is useful for measuring either atomic oxygen fluence or erosion, depending on the information desired. To measure the atomic oxygen erosion yield of a test material, one would need to have two photodiode sensors, one for the test material and one that uses a known erosion yield material (such as Kapton) to measure the atomic oxygen fluence.

Banks, Bruce A.↗

Alkali oxide-tantalum oxide and alkali oxide-niobium oxide ionic conductors

A search was made for new cationic conducting phases in alkali-tantalate and niobate systems. The phase equilibrium diagrams were constructed for the six binary systems Nb2O5-LiNbO3, Nb2O5-NaNbO3, Nb2O5-KNbO3, Ta2O5-NaTaO3, Ta2O5-LiTaO3, and Ta2O5-KTaO3. Various other binary and ternary systems were also examined. Pellets of nineteen phases were evaluated (by the sponsoring agency) by dielectric loss measurements. Attempts were made to grow large crystals of eight different phases. The system Ta2O5-KTaO3 contains at least three phases which showed peaks in dielectric loss vs. temperature. All three contain structures related to the tungsten bronzes with alkali ions in non-stoichiometric crystallographic positions.

Roth, R. S.↗

Comparison of Nd 1.06 and 1.33 micron operation in various hosts

Performances of Nd in various hosts including Nd:YAG, Nd:YLF, Nd:BEL, and Nd:Cr:GSGG were characterized and compared for operation on the nominal 1.06 micron and 1.33 micron transitions. Comparison included continuous mode operation, normal mode operation, Q-switched operation, and gain measurements. Continuous lasing of Nd:Cr:GSGG under lamp pumping is reported for what may be the first time. Characterization included operation with different mirror reflectivities to obtain the internal losses, measurement of the upper laser level lifetime, measurement of the beam quality of the lasers operating under nominally similar circumstances, and measurement of the wavelength. These measurements should provide a comparison of the various Nd hosts under similar circumstances for a wide variety of operational modes and at both wavelengths of interest.

Barnes, Norman P.↗

Control and Non-Payload Communications (CNPC) Prototype Radio Validation Flight Test Report

This report provides an overview and results from the unmanned aircraft (UA) Control and Non-Payload Communications (CNPC) Generation 5 prototype radio validation flight test campaign. The radios used in the test campaign were developed under cooperative agreement NNC11AA01A between the NASA Glenn Research Center and Rockwell Collins, Inc., of Cedar Rapids, Iowa. Measurement results are presented for flight tests over hilly terrain, open water, and urban landscape, utilizing radio sets installed into a NASA aircraft and ground stations. Signal strength and frame loss measurement data are analyzed relative to time and aircraft position, specifically addressing the impact of line-of-sight terrain obstructions on CNPC data flow. Both the radio and flight test system are described.

Shalkhauser, Kurt A.↗

Infrared photometry of O stars

The results of a survey of 50 O stars in the J, H, K, L, and M bands are described. The observations are described, and the fitting of reddening relations to them is discussed. The zero points in the reddening relations are related to the intrinsic colors of the samples of normal stars, and these are compared with theoretical colors. The comparison reveals anomalies at L and M, which are discussed. The residuals for an individual star from the reddening relations are a measure of its infrared excesses, if indeed it has any. How the excesses can be fitted to a stellar wind model to derive a parameter that involves the rate of mass loss in the wind, the stellar radius and temperature, and wind terminal velocity is considered. The results for a number of individual stars are discussed and compared with other mass loss measurements, and it is concluded that no single model is capable of reconciling the IR, UV, radio, and H-alpha observations for the stars.

Castor, J. I.↗

Measurement of Dielectric Loss in Silicon Nitride at Centimeter and Millimeter Wavelengths

This work presents a suite of measurement techniques for characterizing the dielectric loss tangent across a wide frequency range from similar to 1 GHz to 150 GHz using the same test chip. In the first method, we fit data from a microwave resonator at different temperatures to a model that captures the two-level system (TLS) response to extract and characterize both the real and imaginary components of the dielectric loss. The inverse of the internal quality factor is a second measure of the overall loss of the resonator, where TLS loss through the dielectric material is typically the dominant source. The third technique is a differential optical measurement at 150 GHz. The same antenna feeds two microstrip lines with different lengths that terminate in two microwave kinetic inductance detectors (MKIDs). The difference in the detector response is used to estimate the loss per unit length of the microstrip line. Our results suggest a larger loss for SiNx at 150 GHz of tan delta similar to 4 x 10(-3) compared to 2.0 x 10(-3) and greater than or similar to 1 x 10(-3) measured at similar to 1 GHz using the other two methods. These measurement techniques can be applied to other dielectrics by adjusting the microstrip lengths to provide enough optical efficiency contrast and other mm/sub-mm frequency ranges by tuning the antenna and feedhorn accordingly.

Dielectrics loss↗

Electrodermal activity as a proxy for sweat rate monitoring during physical and mental activities

Electrodermal activity has long been used for mental activity monitoring by measuring skin conductance at specific locations, such as fingertips, with high sweat gland density. However, electrodermal activity has not been considered useful for physical activity monitoring, where large sweat volumes are generated, resulting in the accumulation of sweat at the skin–electrode interface and, thus, preventing further dynamic response to sweating events. Here we show that electrodermal activity can be used as a proxy for sweat loss measurement under both low and high physical activity levels. We use wearable sweat sensors that consist of water-permeable electrodes and microfluidic-based sweat analysers, and show that skin conductance is proportional to the instantaneous sweat loss. We demonstrate that sweat loss during exercise can be estimated by integrating skin conductance over time, which can be applied to assess the body hydration status of exercisers. From multisite measurements of skin conductance, we show that the wrist, forearm and upper arm are reflective of physical activity levels, whereas the finger is indicative of mental activity. Simultaneous measurement of two different sites selectively decouples mental and physical activities.

Biomedical engineering↗

Eliminating Surface Oxides of Superconducting Circuits with Noble Metal Encapsulation

The lifetime of superconducting qubits is limited by dielectric loss, and a major source of dielectric loss is the native oxide present at the surface of the superconducting metal. Specifically, tantalum-based superconducting qubits have been demonstrated with record lifetimes, but a major source of loss is the presence of two-level systems in the surface tantalum oxide. Here, we demonstrate a strategy for avoiding oxide formation by encapsulating the tantalum with noble metals that do not form native oxide. By depositing a few nanometers of Au or AuPd alloy before breaking vacuum, we completely suppress tantalum oxide formation. Microwave loss measurements of superconducting resonators reveal that the noble metal is proximitized, with a superconducting gap over 80% of the bare tantalum at thicknesses where the oxide is fully suppressed. Further, our findings suggest that losses in resonators fabricated by subtractive etching are dominated by oxides on the sidewalls, pointing to total surface encapsulation by additive fabrication as a promising strategy for eliminating surface oxide two-level system loss in superconducting qubits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Report on High Energy Arcing Fault Experiments

This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena for medium voltage electrical switchgear containing aluminum conductors. This report covers full-scale laboratory experiments using representative nuclear power plant (NPP) three-phase electrical equipment. Electrical, thermal, and pressure data were recorded for each experiment and documented in this report. This report covers four of the fourteen planned medium voltage electrical enclosure experiments. Subsequent reports will document the additional experiments performed in the future. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the United States Nuclear Regulatory Commission (NRC), the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setups and execution. The HEAF experiments were performed on four near-identical units of General Electric metal-clad medium voltage switchgear. The three-phase arcing fault was initiated on the primary cable connection bus. All four experiments used the same system voltage (6.9 kV) but varied the current and duration. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers and slug calorimeters at various locations around the electrical enclosures. Internal enclosure pressures were measured during the experiments. The experiments were documented with normal and high-speed videography, infrared imaging, and photography. Insights from the experimental series included timing information related to enclosure breach, event progression, mass loss measurements for electrodes and steel enclosures, peak pressure rise, particle analysis, along with visual and thermal imaging data to better understand and characterize the hazard. These results will be used in subsequent efforts to advance the state of knowledge related to HEAF.

42 ENGINEERING↗

Measurement of Heat Transfer in the Turbulent Boundary Layer on a Flat Plate in a Supersonic Flow and Comparison with Skin Friction Results

Local heat-transfer rates on the surface of a heated flat plate at zero incidence to an air stream flowing at Mach numbers of 1.69 and 2.27 are presented. The Reynolds number range for both Mach numbers was 1 million to 10 million. Surface temperatures were maintained near recovery temperature. It was found that the variation of heat transfer with Mach number was in agreement with previously reported variations of directly measured skin friction with Mach number on unheated bodies. The variation with Mach number of the average skin coefficient, as determined from impact-pressure surveys, was in agreement with that from other momentum loss measurements but differed from the variation obtained from directly measured skin friction as reported by others. (author)

Pappas, C C↗

Origin of mechanical and dielectric losses from two-level systems in amorphous silicon

Amorphous silicon contains tunneling two-level systems, which are the dominant energy loss mechanisms for amorphous solids at low temperatures. These two-level systems affect both mechanical and electromagnetic oscillators and are believed to produce thermal and electromagnetic noise and energy loss. However, it is unclear whether the two-level systems that dominate mechanical and dielectric losses are the same; the former relies on the coupling between phonons and two-level systems, with an elastic field coupling constant γ while the latter depends on a two-level systems dipole moment p0, which couples to the electromagnetic field. Mechanical and dielectric loss measurements as well as structural characterization were performed on amorphous silicon thin films grown by electron beam deposition with a range of growth parameters. Samples grown at 425 °C show a large reduction of mechanical loss (34 times) and a far smaller reduction of dielectric loss (2.3 times) compared to those grown at room temperature. Additionally, mechanical loss shows lower loss for thicker films, while dielectric loss shows lower loss for thinner films. Overall, analysis of these results indicate that mechanical loss correlates with atomic density, while dielectric loss correlates with dangling-bond density, suggesting a different origin for these two energy dissipation processes in amorphous silicon.

36 MATERIALS SCIENCE↗

Characterization of GaAlAs optical waveguide heterostructures grown by molecular beam epitaxy

Multiple-layer GaAlAs optical waveguide heterostructures have been grown by MBE. These samples were designed to operate at 840 nm with negligible coupling of guided light to the absorbing GaAs substrate. The Al concentration was 13 percent for the guiding layer and was 16 percent for the cladding layers. The process for growing waveguide layers was calibrated primarily by high-energy electron diffraction, with the optical quality confirmed by photoluminescence measurements. Channel waveguide structures having widths of 5 microns were etched in a low-pressure magnetically confined multipolar plasma reactor. The resulting waveguide structures were characterized by Raman spectroscopy, ellipsometry, AES, and optical-waveguide loss measurements.

Radens, C. J.↗

Coplanar waveguide microwave filter of YBa2Cu3O7

Thin film low-pass microwave filters have been made with laser-ablated YBa2Cu3O(7-delta) (YBCO) deposited on LaAlO3 substrates, using a coplanar waveguide structure. The coplanar waveguide sections had dimensions suited for integrated circuits. Measured losses in liquid nitrogen were superior to the loss in a similar thin-film copper filter throughout the 0 to 9.5 GHz pass-band. A simple transmission-line model is adequate for filter design using YBCO films with repeatable characteristics. The measured filters demonstrate the performance of fully patterned YBCO after sealing in space-qualifiable hermetic packages. Five packaged filters of this design were delivered to the Naval Research Laboratory as candidates for space flight in the High Temperature Superconductivity Space Experiment.

Chew, Wilbert↗

Results of apparent atomic oxygen reactions with spacecraft materials during shuttle flight STS-41G

The effect of atomic oxygen interaction experienced by polymeric-based spacecraft materials is described. An experimental package (ACOMEX) flown on shuttle mission STS-41G carried out the investigation of advanced composite specimens such as carbon-epoxy and Kevlar-epoxy both with and without protective coatings added to thermal protective paints and films. Information on the exposure environment of the specimens was provided by a carbon coated atomic oxygen fluence monitor together with a photographic record. Mass loss measurements and photomicrographs made possible the analysis of the effect of interaction. After a total of about 38 hours of equivalent normal exposure at 225 km altitude the results showed that unprotected exposed surfaces exhibited severe erosion and mass loss with the possibility of seriously degrading structural and thermal performance. However, the specimens with a thin fluorocarbon overcoat showed promise of providing a protective barrier to the attack without altering the base properties of the material.

Zimcik, D. G.↗

Meta-Study of Particulate Detection Losses on Radioactive Air Sample Filters

Several mathematical relationships between air sample filter mass loading and the correlated analytical self-absorption factor were developed using data from other published research in this meta-study. Gross-alpha and -beta applications are addressed for this research. As filter media becomes loaded with particulate matter, there is potential for measurement losses due to self-absorption by mass loading. Components contributing to absorption include particulate dust, radioactive particulates, and filter material. Standards indicate a correction factor should be used when the penetration of radioactive material into the collection media or self-absorption of radiation by the material collected would reduce the detection rate by more than 5%. Previously, losses due to self-absorption have been reported up to 100% over a range up to ~10 mg∙cm -2 mass loading. These absorption losses then can be used to determine a correction factor for sample results. For low mass loadings (e.g., ≤0.1 mg∙cm -2 ) corrections factors in the 0.85 - 1 range have been recommended and used, while at higher mass loadings nearer to 10 mg∙cm -2 correction factors closer to 0 (representing near 100% losses) are used. Based on data from published studies, the different methods for relating percent loss due to self-absorption to mass loading include linear, exponential, quadratic, and trinomial derived functions. Where applicable, both forced zero and non-forced zero results were evaluated. From the derived functions evaluated, the trinomial function provided the best fit. Once the sample filter mass loading is known, the trinomial function can be applied to estimate losses and the corresponding self-absorption factor. When applied to routine operating conditions for radiological facility stacks monitored at the Pacific Northwest National Laboratory for an average sample filter mass loading of 0.09 ± 0.12 (2σ) mg∙cm -2 (excluding negative values and outliers) and a range from 0 - 0.24 mg∙cm -2 , the estimated trinomial function nominal self-absorption losses are less than 5% at 0.09 mg∙cm -2 and less than 10% at 0.24 mg∙cm -2 . The trinomial function is one method that may be used to adjust the activity results of an air sample when the sample-specific mass loading is determined. The application of no correction factor when the ANSI/HPS N13.1-2021 guidance of a 5% threshold for loss is not reached with typical stack sample mass loadings may be reasonable in high-efficiency particulate air filtered systems. For simplicity, it would be conservative in assigning the self-absorption correction factor at the 5% threshold (i.e., 0.95) for general uses but in cases of heavy mass loading to calculate the factor.

air sampling↗

Specific Impulse of Electric Solid Propellant in an Electrothermal Ablation-Fed Pulsed Plasma Thruster

Electric solid propellants are advanced solid chemical rocket propellants that can be controlled (ignited, throttled, and extinguished) through the application and removal of an electric current. Recent work has focused on application of this propellant in an electrothermal ablation-fed pulsed plasma thruster. In this paper, impulse bit measurements in such devices fed by either the electric solid propellant or a traditional state-of-the-art propellant, polytetrafluoroethylene, are expanded upon. It is demonstrated that a surface layer in the hygroscopic electric solid propellant is rapidly ablated over the first few discharges of the device, which correspondingly decreases specific impulse relative to the traditional polytetrafluoroethylene propellant. Correcting these data by subtracting the early discharge ablation mass loss measurements yields a corrected electric solid propellant specific impulse of approximately 300 s. As the test duration increases to a large number of discharges, and the initial mass loss is a reduced fraction of the total, the effect of absorbed water in the propellant is decreased and the specific impulse without any corrections approaches the corrected 300 s value.

Glascock, Matthew S.↗

High-quality microresonators in the longwave infrared based on native germanium

The longwave infrared (LWIR) region of the spectrum spans 8 to 14 μm and enables high-performance sensing and imaging for detection, ranging, and monitoring. Chip-scale LWIR photonics has enormous potential for real-time environmental monitoring, explosive detection, and biomedicine. However, realizing technologies such as precision sensors and broadband frequency combs requires ultra low-loss and low-dispersion components, which have so far remained elusive in this regime. Here, we use native germanium to demonstrate the first high-quality microresonators in the LWIR. These microresonators are coupled to partially-suspended Ge waveguides on a separate glass chip, allowing for the first unambiguous measurements of isolated linewidths. At 8 μm, we measured losses of 0.5 dB/cm and intrinsic quality (Q) factors of 2.5 × 10 5 , nearly two orders of magnitude higher than prior LWIR resonators. Our work portends the development of novel sensing and nonlinear photonics in the LWIR regime.

47 OTHER INSTRUMENTATION↗

Improved Dielectric Properties of Heterostructured Ba2.5Sr0.5TiO3 Thin Film Composites for Microwave Dielectric Devices

In the present work we have deposited MgO and Ba(sub 0.5)Sr(sub 0.5)TiO(sub 3)(BST50) thin layers in different sequences to make MgO:BST50 hetero-structured thin films. These films were characterized by X-ray diffraction and Rutherford backscattering technique and found to be highly (100) textured. The figure of merit {(C(sub0)-C(sub v)/(C(sub0-tandelta)} of the hetero-structured films was found to be higher as compared to pure BST50 films measured at 1 MHz frequency with electric field of 25.3 kV/cm. These films were used to make eight element coupled micro-strip phase shifter and characterized in a frequency range of 13-15 GHz. The high frequency figure of merit (kappa factor, defined as the ratio of degree of phase shift per dB loss) measured at around 14 GHz with electric field of 333 kV/cm has been markedly improved (around 64.28 deg/dB for hetero-structured film as compared to 24.65 deg /dB for pure film). Improvement in dielectric properties in a wide frequency range in the MgO:BST are believed to be due to the higher densification of the hetero-structured films.

Jain, M.↗