Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “local oscillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Truncated non-linear interferometer-based sensor system

A truncated non-linear interferometer-based sensor system includes an input that receives an optical beam and a non-linear amplifier that generates a probe beam and a conjugate beam from the optical beam. The system's local oscillators are related to the probe beam and the conjugate beam. The system includes a sensor that transduces an input with the probe beam and the conjugate beam. The transduction detects changes in the phase of each of the probe beam and the conjugate beam. The system's phase sensitive detectors detect phase modulations between the respective local oscillators, the probe beam, and the conjugate beam and outputs phase signals based on detected phase modulations. The system measures phase signals indicative of the sensor's input resulting from a sum or difference of the phase signals. The measurement exhibits a quantum noise reduction in an intensity difference, a phase sum, or an amplitude difference quadrature.

47 OTHER INSTRUMENTATION↗

Prototype laser-diode-pumped solid state laser transmitters

Monolithic, diode-pumped Nd:YAG ring lasers can provide diffraction-limited, single-frequency, narrow-linewidth, tunable output which is adequate for use as a local oscillator in a coherent communication system. A laser was built which had a linewidth of about 2 kHz, a power of 5 milliwatts, and which was tunable over a range of 30 MHz in a few microseconds. This laser was phase-locked to a second, similar laser. This demonstrates that the powerful technique of heterodyne detection is possible with a diode-pumped laser used as the local oscillator. Laser diode pumping of monolithic Nd:YAG rings can lead to output powers of hundreds of milliwatts from a single laser. A laser was built with a single-mode output of 310 mW. Several lasers can be chained together to sum their power, while maintaining diffraction-limited, single frequency operation. This technique was demonstrated with two lasers, with a total output of 340 mW, and is expected to be practical for up to about ten lasers. Thus with lasers of 310 mW, output of up to 3 W is possible. The chaining technique, if properly engineered, results in redundancy. The technique of resonant external modulation and doubling is designed to efficiently convert the continuous wave, infrared output of our lasers into low duty-cycle pulsed green output. This technique was verified through both computer modeling and experimentation. Further work would be necessary to develop a deliverable system using this technique.

Kane, Thomas J.↗

Superconducting terahertz mixer using a transition-edge microbolometer

We present a new device concept for a mixer element for THz frequencies. This uses a superconducting transition-edge microbridge biased at the center of its superconducting transition near 4.2 K. It is fed from an antenna or waveguide structure. Power from a local oscillator and an RF signal produce a temperature and resulting resistance variation at the difference frequency. The new aspect is the use of a very short bridge in which rapid (less than 0.1 ns) outdiffusion of hot electrons occurs. This gives large intermediate frequency (IF) response. The mixer offers about 4 GHz IF bandwidth, about 80 ohm RF resistive impedance, good match to the IF amplifier, and requires only 1-20 nW of local oscillator power. The upper RF frequency is determined by antenna or waveguide properties. Predicted mixer conversion efficiency is 1/8, and predicted double-sideband receiver noise temperatures are 260 and 90 K for transition widths of 0.1 and 0.5 Tc, respectively.

Prober, D. E.↗

Mixing efficiency in heterodyne systems

How the spatial distributions of the signal and local oscillator fields affect the heterodyne signal to noise ratio is examined for both a single detector and an array of detectors. For an array, the distribution of gain among the intermediate frequency (i.f.) amplifiers is included. The emphasis is on understanding why the distributions are important and what is the key to maximizing the signal to noise ratio in any system. It is shown that for a single detector, the highest signal to noise ratio is obtained with a local oscillator (LO) distribution the same as that of the signal. For an array, the product of the i.f. gain times the LO field at each detector has the same distribution as that of the signal field.

Fink, D.↗

Lightwave-electronic harmonic frequency mixing

Electronic frequency mixers are fundamental building blocks of electronic systems. Harmonic frequency mixing in particular enables broadband electromagnetic signal analysis across octaves of spectrum using a single local oscillator. However, conventional harmonic frequency mixers do not operate beyond hundreds of gigahertz to a few terahertz. If extended to the petahertz scale in a compact and scalable form, harmonic mixers would enable field-resolved optical signal analysis spanning octaves of spectra in a monolithic device without the need for frequency conversion using nonlinear crystals. Here, we demonstrate lightwave-electronic harmonic frequency mixing beyond 0.350 PHz using plasmonic nanoantennas. We demonstrate that the mixing process enables complete, field-resolved detection of spectral content far outside that of the local oscillator, greatly extending the range of detectable frequencies compared to conventional heterodyning techniques. Our work has important implications for applications where optical signals of interest exhibit coherent femtosecond-scale dynamics spanning multiple harmonics.

Science & Technology - Other Topics↗

Preliminary submillimeter spectroscopic measurements using a submillimeter heterodyne radiometer

A submillimeter heterodyne radiometer uses a submillimeter laser, pumped by a CO2 laser, as a local oscillator and a room temperature Schottky barrier diode as the first IF mixer. The radiometer can resolve spectral lines in the submillimeter region of the spectrum (arising from pure rotational molecular transitions) to within 0.3 MHz, using acousto-optic spectrum analyzer which measures the power spectrum by simultaneously sampling 0.3 MHz wide channels over a 100 MHz bandwidth spanning the line. Preliminary observations of eight spectral lines of H2O2, CO, NH3 and H2O, all lying in the 434-524 micrometer wavelength range are described. All eight lines were observed using two local oscillator frequencies obtained by operating the submillimeter laser with either methyl fluoride (CH3F) or formic acid (HCOOH) as the lasing gas. Sample calculations of line parameters from the observed data show good agreement with established values. One development goal is the size and weight reduction of the package to make it suitable for balloon or shuttle experiments to detect trace gases in the upper atmosphere.

Safren, H. G.↗

Detector power linearity requirements and verification techniques for TMI direct detection receivers

A system (36, 98) for determining the linearity of an RF detector (46, 106). A first technique involves combining two RF signals from two stable local oscillators (38, 40) to form a modulated RF signal having a beat frequency, and applying the modulated RF signal to a detector (46) being tested. The output of the detector (46) is applied to a low frequency spectrum analyzer (48) such that a relationship between the power levels of the first and second harmonics generated by the detector (46) of the beat frequency of the modulated RF signal are measured by the spectrum analyzer (48) to determine the linearity of the detector (46). In a second technique, an RF signal from a local oscillator (100) is applied to a detector (106) being tested through a first attenuator (102) and a second attenuator (104). The output voltage of the detector (106) is measured when the first attenuator (102) is set to a particular attenuation value and the second attenuator (104) is switched between first and second attenuation values. Further, the output voltage of the detector (106) is measured when the first attenuator (102) is set to another attenuation value, and the second attenuator (104) is again switched between the first and second attenuation values. A relationship between the voltage outputs determines the linearity of the detector (106).

Reinhardt, Victor S.↗

Flexible, reconfigurable, power efficient transmitter and method

A flexible, reconfigurable, power efficient transmitter device and method is provided. In one embodiment, the method includes receiving outbound data and determining a mode of operation. When operating in a first mode the method may include modulation mapping the outbound data according a modulation scheme to provide first modulation mapped digital data, converting the first modulation mapped digital data to an analog signal that comprises an intermediate frequency (IF) analog signal, upconverting the IF analog signal to produce a first modulated radio frequency (RF) signal based on a local oscillator signal, amplifying the first RF modulated signal to produce a first RF output signal, and outputting the first RF output signal via an isolator. In a second mode of operation method may include modulation mapping the outbound data according a modulation scheme to provide second modulation mapped digital data, converting the second modulation mapped digital data to a first digital baseband signal, conditioning the first digital baseband signal to provide a first analog baseband signal, modulating one or more carriers with the first analog baseband signal to produce a second modulated RF signal based on a local oscillator signal, amplifying the second RF modulated signal to produce a second RF output signal, and outputting the second RF output signal via the isolator. The digital baseband signal may comprise an in-phase (I) digital baseband signal and a quadrature (Q) baseband signal.

Bishop, James W.↗

Automatic carrier acquisition system

An automatic carrier acquisition system for a phase locked loop (PLL) receiver is disclosed. It includes a local oscillator, which sweeps the receiver to tune across the carrier frequency uncertainty range until the carrier crosses the receiver IF reference. Such crossing is detected by an automatic acquisition detector. It receives the IF signal from the receiver as well as the IF reference. It includes a pair of multipliers which multiply the IF signal with the IF reference in phase and in quadrature. The outputs of the multipliers are filtered through bandpass filters and power detected. The output of the power detector has a signal dc component which is optimized with respect to the noise dc level by the selection of the time constants of the filters as a function of the sweep rate of the local oscillator.

Bunce, R. C.↗

Planar Submillimeter-Wave Mixer Technology with Integrated Antenna

High-performance mixers at terahertz frequencies require good matching between the coupling circuits such as antennas and local oscillators and the diode embedding impedance. With the availability of amplifiers at submillimeter wavelengths and the need to have multi-pixel imagers and cameras, planar mixer architecture is required to have an integrated system. An integrated mixer with planar antenna provides a compact and optimized design at terahertz frequencies. Moreover, it leads to a planar architecture that enables efficient interconnect with submillimeter-wave amplifiers. In this architecture, a planar slot antenna is designed on a thin gallium arsenide (GaAs) membrane in such a way that the beam on either side of the membrane is symmetric and has good beam profile with high coupling efficiency. A coplanar waveguide (CPW) coupled Schottky diode mixer is designed and integrated with the antenna. In this architecture, the local oscillator (LO) is coupled through one side of the antenna and the RF from the other side, without requiring any beam sp litters or diplexers. The intermediate frequency (IF) comes out on a 50-ohm CPW line at the edge of the mixer chip, which can be wire-bonded to external circuits. This unique terahertz mixer has an integrated single planar antenna for coupling both the radio frequency (RF) input and LO injection without any diplexer or beamsplitters. The design utilizes novel planar slot antenna architecture on a 3- mthick GaAs membrane. This work is required to enable future multi-pixel terahertz receivers for astrophysics missions, and lightweight and compact receivers for planetary missions to the outer planets in our solar system. Also, this technology can be used in tera hertz radar imaging applications as well as for testing of quantum cascade lasers (QCLs).

Chattopadhyay, Gautam↗

Wide-Band Microwave Receivers Using Photonic Processing

In wide-band microwave receivers of a type now undergoing development, the incoming microwave signals are electronically preamplified, then frequency-up-converted to optical signals that are processed photonically before being detected. This approach differs from the traditional approach, in which incoming microwave signals are processed by purely electronic means. As used here, wide-band microwave receivers refers especially to receivers capable of reception at any frequency throughout the range from about 90 to about 300 GHz. The advantage expected to be gained by following the up-conversion-and-photonic-processing approach is the ability to overcome the limitations of currently available detectors and tunable local oscillators in the frequency range of interest. In a receiver following this approach (see figure), a preamplified incoming microwave signal is up-converted by the method described in the preceeding article. The frequency up-converter exploits the nonlinearity of the electromagnetic response of a whispering gallery mode (WGM) resonator made of LiNbO3. Up-conversion takes place by three-wave mixing in the resonator. The WGM resonator is designed and fabricated to function simultaneously as an electro-optical modulator and to exhibit resonance at the microwave and optical operating frequencies plus phase matching among the microwave and optical signals circulating in the resonator. The up-conversion is an efficient process, and the efficiency is enhanced by the combination of microwave and optical resonances. The up-converted signal is processed photonically by use of a tunable optical filter or local oscillator, and is then detected. Tunable optical filters can be made to be frequency agile and to exhibit high resonance quality factors (high Q values), thereby making it possible to utilize a variety of signal-processing modalities. Therefore, it is anticipated that when fully developed, receivers of this type will be compact and will be capable of both wide-band and narrowband signal processing. Thus, one compact receiver of this type would afford the functionality that, heretofore, could have been obtained only by use of multiple heterodyne microwave receivers.

Matsko, Andrey↗

THIS: A Next Generation Tuneable Heterodyne Infrared Spectrometer for SOFIA

A new infrared heterodyne instrument has been developed which allows the use of both tuneable diode lasers (TDL) and quantum cascade lasers (QCL) as local oscillators (LO). The current frequency tuning range of our system extends from 900 to 1100/cm depending on the availability of lasers but is planned to be extended to 600/cm soon. The IF-bandwidth is 1.4 GHz using an acousto-optical spectrometer (AOS). The frequency resolution and stability of the system is approximately 10(exp 7). Currently, mercury-cadmium-telluride (MCT) detectors are used as mixers while new devices like quantum-well-infrared-photodetectors (QWIP) and hot-electron-bolometers (HEB) are investigated. The IF-bandwidth can be extended to about 3 GHz by using a new broadband acousto-optical spectrometer presently under development. The instrument is fully transportable and can be attached to any infrared or optical telescope. The semiconductor laser is stabilized to a Fabry-Perot ring-resonator, which is also used as an efficient diplexer to superimpose the local-oscillator and the signal radiation. As a first step measurements of trace gases in Earth's atmosphere and non-LTE emission from Venus' atmosphere were carried out as well as observations of molecular features in sunspots. Further astronomical observations from ground-based telescopes and the airborne observatory SOFIA are planned for the future. Of particular interest are molecules without a permanent dipole moment like H2, CH4, C2H2 etc.

Sonnabend, Guido↗

A New Plasma Radar Concept for Simultaneous Magnetic and Density Measurements

An innovative, compact 288GHz interferometer has been fabricated, tested, installed and successfully demonstrated on the LAPD-U magnetized plasma at UCLA. The system takes advantage of frequency modulated (FM) radar techniques to deliver a compact heterodyne system. In addition, the reflected power from the source is taken advantage of to eliminate the need for additional quasi-optical components. Electron density in LAPD-U plasma has recently been increased substantially thereby requiring a higher frequency/shorter wavelength interferometer to avoid deleterious refractive effects. This system satisfies those needs. The system uses a 96GHz varactor tuned Gunn oscillator which passes to a passive tripler. This tripler has ~3% conversion efficiency. The 288GHz radiation is then coupled to free space using a so-called dual-mode or Pickett horn. The output 288GHz beam is then coupled to an aspheric lens manufactured from low-loss, high-density polyethylene. This lens is employed to collimate the emerging beam. Small axial adjustment of the lens position can also be used to create a slowly focusing beam so as to optimize the measured signal. In addition, up-down or side-to-side adjustment of the lens can be utilized to steer the beam vertically or horizontally – again to optimize alignment. The propagating beam passes through a beam splitter and then through a water-free, bubble-free fused quartz window into the LAPD-U vacuum vessel. The beam-splitter is a thin sheet of G10 which reflects a small fraction of the incident power (~5 %) towards a zero-bias detector optimized for the frequency range from 220 to 300GHz. Note that waveguides at this frequency have dimensions of ~0.9mm x 0.45mm and so have very large conductive losses. This drives the use of quasi-optical propagation. The detector requires no DC bias and is very responsive (> 1V/mW into 1MΩ). Radiation is coupled to the detector via a similar lens-horn arrangement used for the launch. This reflected beam acts as the local oscillator or reference millimeter-wave beam for the detector. The remainder of the launched source beam then enters the LAPD-U vacuum vessel and passes through the plasma at the mid-plane until reaching the opposing port which is closed off with an aluminum flange. This flange is used as a mirror to retroreflect the incident 288GHz beam back along its path. The retroreflected beam exits the input port but does NOT couple directly into the zero-bias detector. Instead, the majority of the return power continues towards the 288GHz source. As mentioned above the transmitted beam enters the source a second time. This would appear undesirable. However, at these frequencies multipliers are highly non-linear elements which results in a significant portion of the return beam (~20%) re-emerging from the multiplier and horn and then coupling via the G10 beam-splitter to the zero-bias detector. This approach eliminated the need for a second quasi-optical beam-splitter. The system is extremely compact measuring approximately 28 inches x 20 inches. The above did not explain how heterodyne operation was achieved. As mentioned above the Gunn oscillator is able to be varactor tuned. This allows a low voltage to be applied to control the operating frequency of the Gunn oscillator. During heterodyne operation a sawtooth shaped voltage is applied to the varactor at 750kHz using an 80MHz Arbitrary Waveform Generator (AWG). This voltage changes the Gunn frequency linearly during the up-sweep which is then reset abruptly at the sawtooth crash to be immediately followed by another linear sweep. Passage through the 288GHz multiplier triples the frequency change experienced by the electromagnetic wave. These frequency changes are small – tens of megahertz. This FM radar approach results in the launched electromagnetic wave frequencies at the detector for the reference and plasma wave to be different. The approximately 10 ns delay propagation delay for the plasma beam results in the local oscillator and plasma beams NOT having an identical frequency – there is in fact a fixed difference frequency. The frequency tuning level of the Gunn oscillator is then adjusted so that there is ONE cycle of this difference frequency during each linear ramp. During the sawtooth crash or downward re-sweep this one cycle replays in reverse but on a very fast timescale. The process then repeats. Low-pass filtering eliminates the fast re-sweep to leave a pure sine wave heterodyne signal. When the plasma is present it introduces a phase delay in the sine wave (caused by the extremely small Doppler shift resulting from the optical path length change). Of course, to measure this phase change we need a reference. This is simply obtained from an arbitrary waveform generator which provides a synchronized output pulse train which again is low pass filtered to obtain a 750kHz sinusoidal voltage reference for the interferometer. The interferometer was installed on LAPD-U where it has worked reliably and has established that electron densities exceeding 1x10 13 cm -3 are routinely achieved. In addition, the system sensitivity was able to easily observe density fluctuation at frequencies up to 50kHz. FM Radar techniques have enabled a full demonstration of a compact, sensitive, high frequency (288GHz/1mm) heterodyne interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photonic Integrated Circuit TUned for Reconnaissance and Exploration (PICTURE)

The mid-infrared (MIR) spectral range (3-5 μm) is of particular interest for remotely sensing gaseous molecules such as H2O, CO2, CH4, N2O, CO, NH3, and other compounds. The infrared spectra of planets, moons, comets, and asteroids are rich in information, including gas composition and surface mineralogy. Significant advances in technology have emerged for ground-based telescopes, including the higher spectral resolution permitted by cross-dispersed instruments and heterodyne techniques. New technologies offer the opportunity to break this barrier, by using solid- state photonics. In the past three years, under the NASA ROSES PICASSO program, we have been developing key components for a revolutionary MIR spectrometer: Photonic Integrated Circuit TUned for Reconnaissance and Exploration (PICTURE), which is based on integrated photonics technology that offers ultra-small size, weight, and power (SWaP) with non-moving parts and low cost for future planetary missions. In this paper, we will describe our science and technology development progress leading to demonstrating the concept and functionalities of the PICTURE instrument. The photonic integrated circuit spectrometer (PICS) of the PICTURE instrument uses an integrated heterodyne detection scheme to significantly reduce SWaP and improve sensitivity. Our program goals are to advance the building blocks needed for the PICS, which include arrayed waveguide gratings (AWGs), quantum cascade lasers (QCLs) as local oscillators, and quantum cascade detectors (QCDs) as heterodyne detectors. In addition, we are leveraging a NASA SBIR program to develop the toolsets needed to fabricate MIR photonics lanterns (PL). The PL is a critical component that enables PICTURE to bring a signal from the collecting telescope to the PICS, which requires single optical mode inputs. PICTURE focuses on the CO spectral band at 4.6-4.8 μm that is of key importance to cometary science. We also continue to explore future instrument concepts that exploit the broad wavelength potential of the PICS design to perform spectroscopy spanning the full MIR and longwave IR (LWIR) bands. This will have wide applicability in planetary science, for example, to probe the strongest CO2, H2O, and CH4 transitions that are difficult (CH4) or impossible (CO2, H2O) to detect using Earth-based telescopes due to atmospheric opacity. Each integrated-photonics-spectrometer chip will feature a single heterodyne room-temperature laser with a wide wavelength tuning range, or multiple local-oscillator lasers for much broader spectral coverage. The fully developed PICTURE instrument will provide a cost-effective, high-resolution spectrometer for future space applications.

Anthony W Yu↗

Photonic Integrated Circuit TUned for Reconnaissance and Exploration (PICTURE)

The mid-infrared (MIR) spectral range (3-5 μm) is of particular interest for remotely sensing gaseous molecules such as H2O, CO2, CH4, N2O, CO, NH3, and other compounds. The infrared spectra of planets, moons, comets, and asteroids are rich in information, including gas composition and surface mineralogy. Significant advances in technology have emerged for ground-based telescopes, including the higher spectral resolution permitted by cross-dispersed instruments and heterodyne techniques. New technologies offer the opportunity to break this barrier, by using solid-state photonics. In the past three years, under the NASA ROSES PICASSO program, we have been developing key components for a revolutionary MIR spectrometer: Photonic Integrated Circuit TUned for Reconnaissance and Exploration (PICTURE), which is based on integrated photonics technology that offers ultra-small size, weight, and power (SWaP) with non-moving parts and low cost for future planetary missions. In this paper, we will describe our science and technology development progress leading to demonstrating the concept and functionalities of the PICTURE instrument. The photonic integrated circuit spectrometer (PICS) of the PICTURE instrument uses an integrated heterodyne detection scheme to significantly reduce SWaP and improve sensitivity. Our program goals are to advance the building blocks needed for the PICS, which include arrayed waveguide gratings (AWGs), quantum cascade lasers (QCLs) as local oscillators, and quantum cascade detectors (QCDs) as heterodyne detectors. In addition, we are leveraging a NASA SBIR program to develop the toolsets needed to fabricate MIR photonics lanterns (PL). The PL is a critical component that enables PICTURE to bring a signal from the collecting telescope to the PICS, which requires single optical mode inputs. PICTURE focuses on the CO spectral band at 4.6-4.8 μm that is of key importance to cometary science. We also continue to explore future instrument concepts that exploit the broad wavelength potential of the PICS design to perform spectroscopy spanning the full MIR and longwave IR (LWIR) bands. This will have wide applicability in planetary science, for example, to probe the strongest CO2, H2O, and CH4 transitions that are difficult (CH4) or impossible (CO2, H2O) to detect using Earth-based telescopes due to atmospheric opacity. Each integrated-photonics-spectrometer chip will feature a single heterodyne room-temperature laser with a wide wavelength tuning range, or multiple local-oscillator lasers for much broader spectral coverage. The fully developed PICTURE instrument will provide a cost-effective, high-resolution spectrometer for future space applications.

Anthony W Yu↗

Photonic Integrated Circuit TUned for Reconnaissance and Exploration (PICTURE)

The mid-infrared (MIR) spectral range (3-5 μm) is of particular interest for remotely sensing gaseous molecules such as H2O, CO2, CH4, N2O, CO, NH3, and other compounds. The infrared spectra of planets, moons, comets, and asteroids are rich in information, including gas composition and surface mineralogy. Significant advances in technology have emerged for ground-based telescopes, including the higher spectral resolution permitted by cross-dispersed instruments and heterodyne techniques. New technologies offer the opportunity to break this barrier, by using solid-state photonics. In the past three years, under the NASA ROSES PICASSO program, we have been developing key components for a revolutionary MIR spectrometer: Photonic Integrated Circuit TUned for Reconnaissance and Exploration (PICTURE), which is based on integrated photonics technology that offers ultra-small size, weight, and power (SWaP) with non-moving parts and low cost for future planetary missions. In this paper, we will describe our science and technology development progress leading to demonstrating the concept and functionalities of the PICTURE instrument. The photonic integrated circuit spectrometer (PICS) of the PICTURE instrument uses an integrated heterodyne detection scheme to significantly reduce SWaP and improve sensitivity. Our program goals are to advance the building blocks needed for the PICS, which include arrayed waveguide gratings (AWGs), quantum cascade lasers (QCLs) as local oscillators, and quantum cascade detectors (QCDs) as heterodyne detectors. In addition, we are leveraging a NASA SBIR program to develop the toolsets needed to fabricate MIR photonics lanterns (PL). The PL is a critical component that enables PICTURE to bring a signal from the collecting telescope to the PICS, which requires single optical mode inputs. PICTURE focuses on the CO spectral band at 4.6-4.8 μm that is of key importance to cometary science. We also continue to explore future instrument concepts that exploit the broad wavelength potential of the PICS design to perform spectroscopy spanning the full MIR and longwave IR (LWIR) bands. This will have wide applicability in planetary science, for example, to probe the strongest CO2, H2O, and CH4 transitions that are difficult (CH4) or impossible (CO2, H2O) to detect using Earth-based telescopes due to atmospheric opacity. Each integrated-photonics-spectrometer chip will feature a single heterodyne room-temperature laser with a wide wavelength tuning range, or multiple local-oscillator lasers for much broader spectral coverage. The fully developed PICTURE instrument will provide a cost-effective, high-resolution spectrometer for future space applications.

Anthony W. Yu↗

Compact, Miniature MMIC Receiver Modules for an MMIC Array Spectrograph

A single-pixel prototype of a W-band detector module with a digital back-end was developed to serve as a building block for large focal-plane arrays of monolithic millimeter-wave integrated circuit (MMIC) detectors. The module uses low-noise amplifiers, diode-based mixers, and a WR10 waveguide input with a coaxial local oscillator. State-of-the-art InP HEMT (high electron mobility transistor) MMIC amplifiers at the front end provide approximately 40 dB of gain. The measured noise temperature of the module, at an ambient temperature of 300 K, was found to be as low as 450 K at 95 GHz. The modules will be used to develop multiple instruments for astrophysics radio telescopes, both on the ground and in space. The prototype is being used by Stanford University to characterize noise performance at cryogenic temperatures. The goal is to achieve a 30-50 K noise temperature around 90 GHz when cooled to a 20 K ambient temperature. Further developments include characterization of the IF in-phase (I) and quadrature (Q) signals as a function of frequency to check amplitude and phase; replacing the InP low-noise amplifiers with state-of-the-art 35-nm-gate-length NGC low-noise amplifiers; interfacing the front-end module with a digital back-end spectrometer; and developing a scheme for local oscillator and IF distribution in a future array. While this MMIC is being developed for use in radio astronomy, it has the potential for use in other industries. Applications include automotive radar (both transmitters and receivers), communication links, radar systems for collision avoidance, production monitors, ground-penetrating sensors, and wireless personal networks.

Kangaslahti, Pekka P.↗

Second Harmonic Generation Electric Field Triplet Interferometry for Absolute Phasing

We report second harmonic generation (SHG) electric field triplet interferometry performed using three mutually coherent ultrafast pulses in a common path with controllable relative phases, namely, the light fields of a sample signal (SI), a reference oscillator (RO), and a local oscillator (LO). The ROLO phase determined from the interference of the light fields produced by two quartz wafers is subtracted from the phase determined from the SIROLO interferogram to yield the signal phase, ϕ SI . The new method also calibrates the measured SHG intensity from a given sample internally by sending the fundamental light field reflected from the sample into one of the quartz wafers in the ROLO element. The approach avoids having to exchange the sample against a reference material with a known χ(2) value or known phase and accounts on-the-fly for situations where the reflected fundamental light field intensity changes with experimental conditions. The new method is successfully benchmarked against z-cut α-quartz, fused silica held at its point of zero charge, and hematite nanolayers in air, across three different interferometers. Furthermore, the approach should be applicable for other second-order nonlinear spectroscopies, such as vibrational or electronic sum-frequency generation.

Interfaces↗