Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder

Owing to the increased use of power electronic based appliances and energy-efficient home equipment such as modern lighting loads, the percentage of nonlinear loads has increased in the distribution system, which can impact system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determination of possible interactions at harmonic frequencies, protection planning, and the effect of system impedance. This paper focuses on harmonic load flow analysis for multiple residential load types to determine the expected impacts on an modeled distribution secondary. For this study, the household appliances include lighting, power electronic, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split phase at a nominal frequency of 60 Hz. The harmonic spectrums, as obtained from the experimental evaluation of real loads, are used to inform the harmonic load flow for a detailed secondary network, including the distribution service transformer extracted from a real distribution feeder's model. Additionally, the impact of voltage harmonics on a three-phase test load is presented with experimental results. The harmonic data of the transformer terminal voltage, as obtained from the former load flow study, are scaled to generate the source voltage for the three-phase configuration of the grid simulator to make the test setup very similar to a typical secondary design in the U.S.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

A Framework for Identifying Building Energy Models of Localized Utility Service Areas Using Smart Meter Data

Bottom-up load modeling of buildings offers a versatile approach to simulating baseline demand and scenarios of future technology evolution and adoption at the individual building level. This capability is essential to understanding how future load shapes may change with the adoption of electric equipment and vehicles, particularly as it relates to grid planning and infrastructure investments. Traditionally, grid planning techniques have used historical load data to predict future load and infrastructure needs. However, with the anticipated rise in adoption of electrification technologies such as heat pumps and electric vehicles, historical data become less reliable predictors of the future. By employing ResStock, a high-fidelity building stock modeling tool, we can fine-tune electrification scenarios and aggregate models to represent varying geographic resolutions of the grid system, while considering the underlying features of homes. This may enable a more accurate and responsive approach to anticipate and plan for the evolving landscape of energy demands. We present a new framework that leverages building stock energy modeling to identify building models that align with the load shapes and housing attributes of buildings with AMI data. This approach applies two model layers: (1) a classification step that identifies the presence of air conditioning, electric heating, and electric water heating, and (2) an optimization routine that identifies building energy models aligning with load profile data from advanced metering infrastructure meters. This report demonstrates one approach to deploying this framework, and presents results for three test cases that use both modeled and AMI data to assess performance. For a test case using AMI data in Fort Collins, Colorado, we observed a median monthly electricity load CV-RMSE of 16.6%, and a top ten daily heating and cooling median absolute percent error of 7.7% and 8.3%, respectively. For each AMI meter, we identify a set of potential energy models so that downstream use-cases can account for uncertainty driven by variability of baseline technologies and occupant behavior, which impact the response to electrification and energy efficiency scenarios. Our results indicate that ResStock has potential as a scalable solution for modeling residential energy demand at local grid resolutions. Its performance depends on location-specific factors, underlying building characteristics, and the level of aggregation, offering a path towards more precise and adaptive distribution grid planning for the evolving energy landscape.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Composite Load Spectra for Select Space Propulsion Structural Components

Generic load models are described with multiple levels of progressive sophistication to simulate the composite (combined) load spectra (CLS) that are induced in space propulsion system components, representative of Space Shuttle Main Engines (SSME), such as transfer ducts, turbine blades and liquid oxygen (LOX) posts. These generic (coupled) models combine the deterministic models for composite load dynamic, acoustic, high-pressure and high rotational speed, etc., load simulation using statistically varying coefficients. These coefficients are then determined using advanced probabilistic simulation methods with and without strategically selected experimental data. The entire simulation process is included in a CLS computer code. Applications of the computer code to various components in conjunction with the PSAM (Probabilistic Structural Analysis Method) to perform probabilistic load evaluation and life prediction evaluations are also described to illustrate the effectiveness of the coupled model approach.

Ho, Hing W.↗

Smart Ventilation for Advanced California Homes

This project investigated smart ventilation approaches to minimize energy use for providing indoor air quality (IAQ) in high performance new California homes. Evaluation criteria included annual ventilation-related energy, peak energy and time-of-use savings, and the indoor air quality relative to a minimally code-compliant ventilation system. The simulations used CONTAM’s air flow and contaminant transport model, combined with the EnergyPlus building loads model. House types representing the default California Energy Code compliance homes were investigated for four California climate zones, covering a wide range of climate types. Both single and multi-zone smart ventilation controls were investigated. Contaminant sources included contaminants emitted continuously and varying with time, temperature and relative humidity, episodic emissions from occupant activities and outdoor particles. Single-zone ventilation controls that varied ventilation depending on outdoor temperatures were able to consistently save half of ventilation-related energy without compromising long-term IAQ. Ventilation strategies that tracked occupancy were less successful, because this work included generic contaminants with constant background emission rates. Energy performance for occupancy controls improved with a one-hour pre-occupancy flush out strategy. The addition of zoning ventilation controls did not offer significant IAQ to energy improvements compared to non-zonal versions of the same ventilation system type. The best controls had HVAC energy savings of 10-20%, with individual cases reaching up to 40% savings. However, these savings cannot be achieved without worsening personal exposures for at least one contaminant. A metric is needed to assess the competing changes in exposure to different contaminants in order to determine the net-health impacts of a control strategy. Controls that directly sensed contaminants and controlled them to acceptable levels showed that the California OEHHA limit for formaldehyde completely dominates system performance, with homes not able to meet the limit even with continuous operation of a fan sized to twice the current code minimum.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Expert system development for probabilistic load simulation

A knowledge based system LDEXPT using the intelligent data base paradigm was developed for the Composite Load Spectra (CLS) project to simulate the probabilistic loads of a space propulsion system. The knowledge base approach provides a systematic framework of organizing the load information and facilitates the coupling of the numerical processing and symbolic (information) processing. It provides an incremental development environment for building generic probabilistic load models and book keeping the associated load information. A large volume of load data is stored in the data base and can be retrieved and updated by a built-in data base management system. The data base system standardizes the data storage and retrieval procedures. It helps maintain data integrity and avoid data redundancy. The intelligent data base paradigm provides ways to build expert system rules for shallow and deep reasoning and thus provides expert knowledge to help users to obtain the required probabilistic load spectra.

Ho, H.↗

tell: a Python package to model future total electricity loads in the United States

The purpose of the Total ELectricity Load (tell) model is to generate 21st century profiles of hourly electricity load (demand) across the Conterminous United States (CONUS). tell loads reflect the impact of climate and socioeconomic change at a spatial and temporal resolution adequate for input to an electricity grid operations model. tell uses machine learning to develop profiles that are driven by projections of climate/meteorology and population. tell also harmonizes its results with United States (U.S.) state-level, annual projections from a national- to global-scale energy-economy model. This model accounts for a wide range of other factors affecting electricity demand, including technology change in the building sector, energy prices, and demand elasticities, which stems from model coupling with the U.S. version of the Global Change Analysis Model (GCAM-USA). tell was developed as part of the Integrated Multisector Multiscale Modeling (IM3) project. IM3 explores the vulnerability and resilience of interacting energy, water, land, and urban systems in response to compound stressors, such as climate trends, extreme events, population, urbanization, energy system transitions, and technology change

24 POWER TRANSMISSION AND DISTRIBUTION↗

Tectonics of planetary loading - A general model and results

The tectonics of planetary loading is investigated using an analytical model for determining the stresses in an arbitrarily thick spherical shell due to an idealized axisymmetric load. The model includes the flat plate and thin shell membrane approximations as end members, and makes it possible to determine the nature of the transition between them. Using this model, the stress states and the resulting tectonic patterns due to an idealized exponential load are determined as functions of five dimensionless parameters: the ratio of the lithospheric thickness to the planetary radius; the decay width of the load; the 'support parameter', which is the ratio of the buoyancy to the flexural support; the angular distance from the load center; and the normalized radial distance from the planet center.

Janes, D. M.↗

Drought-induced changes in groundwater-surface water exchange at Lake Mead area

This study focuses on the Lake Mead region in the southwestern United States, a key water reservoir serving over 25 million people and agricultural lands across several states. The area has experienced recurring anthropogenic droughts since the early 2000s. We investigate the hydrological response of the coupled surface-groundwater system to the 2020–2022 drought, one of the most severe on record. To this end, we use Sentinel-1 Interferometric Synthetic Aperture Radar (InSAR) data to quantify vertical land motion caused by the elastic response of the crust to water-mass loss in the lake vicinity. Next, we apply an inverse elastic load modeling framework to quantify water loss. We further assess possible hydraulic connectivity between Lake Mead and adjacent groundwater reservoirs. We detect ground uplift of up to 8 mm/yr near the lake center, likely due to crustal rebound from reduced water-mass loading. We estimated the total water storage loss at 3.03 ± 0.25 km 3 /yr across a 3150 km 2 area surrounding Lake Mead. Groundwater accounts for approximately a third of that, being 0.94 ± 0.32 km 3 /yr. In addition, observed time lags of 6–98 days between lake and groundwater level responses, corresponding to a lateral diffusivity of 3.2–86 m 2 /s, suggest spatially variable connectivity between the lake and aquifers. These findings highlight that drought impacts propagate through the subsurface within interconnected systems, resulting in reduced buffering capacity of groundwater resources following droughts, and emphasizing the need for more integrated surface and groundwater management strategies to enhance resilience under climate and anthropogenic stressors.

58 GEOSCIENCES↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder: Preprint

This paper focuses on the harmonic load flow study for a set of residential loads and the impacts of the harmonic contents on the distribution feeder. Owing to the increased use of the power electronic based appliances and energy efficient home equipment like the lighting loads, the percentage of non-linear loads has increased in the distribution system which can impact the system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determining possible interactions at harmonic frequencies, protection planning, and the effect of the system impedance. For this study, the household appliances include the lighting, power electronics, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split-phase at a nominal frequency of 60 Hz. The harmonic spectrum as obtained from the experimental data is used to solve the harmonic load flow for a detailed secondary network including the distribution transformer extracted from a real distribution feeder's model. Additionally, the impact of the voltage harmonic on a three phase test load is presented through experimental results. The harmonic data of the transformer terminal voltage as obtained from the former load flow study is scaled to generate the source voltage for the three phase configuration of the grid simulator to make the test setup very similar to a real scenario.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Deep Generative Model for Non-Intrusive Identification of EV Charging Profiles

The proliferation of electric vehicles (EVs) brings environmental benefits and technical challenges to power grids. An identification algorithm which can accurately extract individual EV charging profiles out of widely available smart meter measurements has attracted great interests. This paper proposes a non-intrusive identification framework for EV charging profile extraction, which is driven by deep generative models (DGM). First, the proposed DGM is designed as a representation layer embedded into the Markov process and used to model the joint probability distribution of available time-series data. A novel contribution is to approximate posterior distributions by neural networks whose parameters are obtained by variational inference and supervised learning. Second, the EV charging status is inferred from the DGM via dynamic programming. Lastly, the desired EV charging profile can be reconstructed by the rated power of EV models and inferred status. Compared with the benchmark Hidden Markov Models, the proposed framework can better handle noise in data with less computational complexity and better overall accuracy performances with smaller recall. The proposed framework is validated by numerical experiments on the Pecan Street dataset.

33 ADVANCED PROPULSION SYSTEMS↗

Data-Driven Linear Parameter-Varying Modeling and Control of Flexible Loads for Grid Services

Flexible loads have great potential to improve the electric grid's flexibility and stability. To effectively control large ensembles of heterogeneous loads, reliable models thereof are required. This paper presents a data-driven modeling and control approach to manage flexible loads for providing grid services. We leverage a linear parameter-varying autoregressive moving average (LPV-ARMA) model to describe the aggregate load response, where the parameters in the model are used to capture external environmental impacts (e.g., weather). A gain-scheduling feedback controller is then developed to adapt to environmental variations. This data-driven approach can be easily applied to different types of loads in various environmental conditions. In addition to the ensemble controller, distributed load controllers are designed to deliver grid services, while maintaining the quality of service of inherent load tasks. We demonstrate the work on the IEEE 37-node distribution system for real-time power regulation services through control of thermostatically controlled loads.

61 RADIATION PROTECTION AND DOSIMETRY↗

Application of a Prize Mechanism to Address Data Utilization Challenges at Utilities

The electric industry sector is facing an “explosion” of data from a variety of sources. Electric sector stakeholders need to define how to capitalize on large datasets, both those they create and those from other sources (like data on weather, buildings, electric vehicles, etc.), to improve reliability and resilience and meet the changing system dynamics from renewable integration. For the electricity sector to fully utilize these vast new datasets, it must undergo a transformation in how it manages data quality, storage, and processing. The U.S. Department of Energy (DOE) Office of Electricity (OE) is committed to accelerating research, development, and demonstration of new technologies and tools within the electricity sector to advance reliability, resilience, and affordable operation of the power system. Through the prize mechanism, OE identified two widespread data-related challenges for utilities—load modeling and data analysis automation—and offered an opportunity for utilities and teams of software engineers to identify additional challenges faced by utilities. After completing one round of the American-Made Digitizing Utilities Prize, OE, the National Renewable Energy Laboratory (NREL) as the prize administrator, and Pacific Northwest National Laboratory (PNNL) as the domain experts have compiled the results and lessons learned to feed into the second round of the prize.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Model-Free Voltage Control Approach to Mitigate Motor Stalling and FIDVR for Smart Grids

Electric power networks are large and highly nonlinear dynamical systems that present unique challenges to control design. Though there is a large number of dynamic models for power system stability and control, many models are only useful with right assumptions and wrong for other tasks. Moreover, the dynamic behavior of the grid is increasingly complex under the banner of smart grids. These lead to the difficulty of developing appropriate dynamic modeling, and thus an efficient control strategy. To avoid such modeling challenges, here we present a novel dynamic voltage control strategy based on a model-free control (MFC) approach, requiring no modeling procedure. In particular, it focuses on fault-induced delayed voltage recovery (FIDVR) events, which require complex and accurate dynamic load models to replicate such events. This work utilizes MFC as an online controller to achieve the desired voltage stability under the FIDVR event. The proposed MFC strategy allows simple implementation and low computational cost for efficient mitigation of FIDVR. For benchmarking, a reasonably accurate dynamic performance model is explored. Simulation results with the IEEE 57 bus test network demonstrate the enhanced dynamic voltage profile for load buses having induction motors with the support of reactive power resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Developing and tuning a community scale energy model for a disadvantaged community

This work describes the development of a community-scale energy model for a mixed-use low-income community located in Huntington Beach, CA. An accurate community-scale energy model is useful for evaluating the use of limited capital resources used to invest in clean energy technologies. This work lays out the process of developing such a model while relying primarily on publicly available data and highlighting critical partnerships necessary for model development success. The primary contribution of this work is the demonstration of the process used to develop an accurate energy model for a disadvantaged community when minimal building and energy use data is available. The heart of the model is the physics-based community scale energy modeling platform URBANopt. Using a bottom-up load modeling approach, energy simulated energy use falls within 3% or less of aggregate annual utility data, and within 10% or less aggregate monthly utility data. The demonstrated model development and tuning process can be used by others to characterize other atypical communities, which may differ significantly from prototypical models.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development of Aeroservoelastic Analytical Models and Gust Load Alleviation Control Laws of a SensorCraft Wind-Tunnel Model Using Measured Data

Aeroservoelastic (ASE) analytical models of a SensorCraft wind-tunnel model are generated using measured data. The data was acquired during the ASE wind-tunnel test of the HiLDA (High Lift-to-Drag Active) Wing model, tested in the NASA Langley Transonic Dynamics Tunnel (TDT) in late 2004. Two time-domain system identification techniques are applied to the development of the ASE analytical models: impulse response (IR) method and the Generalized Predictive Control (GPC) method. Using measured control surface inputs (frequency sweeps) and associated sensor responses, the IR method is used to extract corresponding input/output impulse response pairs. These impulse responses are then transformed into state-space models for use in ASE analyses. Similarly, the GPC method transforms measured random control surface inputs and associated sensor responses into an AutoRegressive with eXogenous input (ARX) model. The ARX model is then used to develop the gust load alleviation (GLA) control law. For the IR method, comparison of measured with simulated responses are presented to investigate the accuracy of the ASE analytical models developed. For the GPC method, comparison of simulated open-loop and closed-loop (GLA) time histories are presented.

Silva, Walter A.↗

Development of Aeroservoelastic Analytical Models and Gust Load Alleviation Control Laws of a SensorCraft Wind-Tunnel Model Using Measured Data

Aeroservoelastic (ASE) analytical models of a SensorCraft wind-tunnel model are generated using measured data. The data was acquired during the ASE wind-tunnel test of the HiLDA (High Lift-to-Drag Active) Wing model, tested in the NASA Langley Transonic Dynamics Tunnel (TDT) in late 2004. Two time-domain system identification techniques are applied to the development of the ASE analytical models: impulse response (IR) method and the Generalized Predictive Control (GPC) method. Using measured control surface inputs (frequency sweeps) and associated sensor responses, the IR method is used to extract corresponding input/output impulse response pairs. These impulse responses are then transformed into state-space models for use in ASE analyses. Similarly, the GPC method transforms measured random control surface inputs and associated sensor responses into an AutoRegressive with eXogenous input (ARX) model. The ARX model is then used to develop the gust load alleviation (GLA) control law. For the IR method, comparison of measured with simulated responses are presented to investigate the accuracy of the ASE analytical models developed. For the GPC method, comparison of simulated open-loop and closed-loop (GLA) time histories are presented.

Walter A. Silva↗

Improvements to the Simplified Loads Methodology in IEC 61400-2: November 22, 2021 - November 21, 2022

The "Simplified Loads Model" (SLM) of IEC 61400-2 provides a simple methodology to assess the structural integrity of a small wind turbine (SWT). The SLM is unique to the small wind turbine standard. It was included to allow SWT manufacturers with limited resources to undertake integrity checks at a reasonable cost in time and resources and avoid the expense of detailed aeroelastic simulations. Unfortunately, the SLM has gained the reputation of being overly conservative and this has reduced its value to the SWT community and its use in SWT design and certification. Conservatism in design standards is needed but excessive conservatism is not. The aim of this report is to address the principal areas of excess conservatism and recommend changes to the SLM that preserve its simplicity but reduce the excess. The changes for the ultimate loads are consistent with their treatment in aeroelastic modelling for certification and with related codes for wind loading on structures. The recommendations for a new fatigue design load case are also based on aeroelastic simulations, in this case of five SWTs of varying configurations with rated power from 2.4 to 50 kW. It is also pointed out the design load case for yawed operation omits an important term. The recommended inclusion of this term would make the SLM slightly more conservative for this case.

17 WIND ENERGY↗

A multi-sheath model for highly nonlinear plasma wakefields

An improved description for nonlinear plasma wakefields with phase velocities near the speed of light is presented and compared against fully kinetic particle-in-cell simulations. These wakefields are excited by intense particle beams or lasers pushing plasma electrons radially outward, creating an ion bubble surrounded by a sheath of electrons characterized by the source term S≡−1enp(ρ−Jz/c), where ρ and Jz are the charge and axial current densities, respectively. Previously, the sheath source term was described phenomenologically with a positive-definite function, resulting in a positive definite wake potential. In reality, the wake potential is negative at the rear of the ion column which is important for self-injection and accurate beam loading models. To account for this, we introduce a multi-sheath model in which the source term, S, of the plasma wake can be negative in regions outside the ion bubble. Using this model, we obtain a new expression for the wake potential and a modified differential equation for the bubble radius. Numerical results obtained from these equations are validated against particle-in-cell simulations for unloaded and loaded wakes. The new model provides accurate predictions of the shape and duration of trailing bunch current profiles that flatten plasma wakefields. It is also used to design a trailing bunch for a desired longitudinally varying loaded wakefield. We present beam loading results for laser wakefields and discuss how the model can be improved for laser drivers in future work. Finally, we discuss differences between the predictions of the multi- and single-sheath models for beam loading.

Dalichaouch, T. N. (ORCID:0000000247350150)↗