Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load aggregation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

California Price Response Potential Study

California's energy landscape is undergoing a significant transformation, driven by the increasing integration of renewable energy sources, the increased adoption of distributed energy resources, the electrification of end-use loads, and the growing need for grid efficiency. To address these challenges, recent revisions to the State’s Load Management Standards (LMS) require all of California’s large utilities and community choice aggregators (CCAs) to offer dynamic electricity pricing options to customers by 2027. Dynamic pricing, which involves varying electricity rates based on real-time supply and demand conditions, offers a promising solution for optimizing grid operations, reducing costs, and incentivizing efficient use of grid capacity. Effective implementation of dynamic pricing requires understanding the potential impacts on customer bills, system load, and the cost-effectiveness of automation technologies. This study aims to evaluate the load response of various end-use devices to hourly dynamic prices. The end-uses studied here are space cooling, space heating, water heating, crop irrigation, pool and spa pumps, and electric vehicle (EV) charging, all for both residential and commercial applications, except for crop irrigation. In 2030, these end uses are forecasted to account for 18% of annual electricity demand in the state, but 40% of demand in the peak net load hour. By modeling possible price-responsive load dispatch algorithms and assessing the resulting impacts on both individual bills and the overall grid, we seek to inform policymakers and utilities about the potential benefits and challenges associated with dynamic pricing, and considerations for the design of dynamic pricing tariffs. Additionally, we will explore the cost effectiveness of adopting automation technologies to enable devices to respond more effectively to real-time price signals. This study considers a range of price profiles, accounting for differences across utilities and customer classes, and presents scenarios for dynamic price design via variation in the percentage of total customer electric costs that are allocated dynamically (versus constituting a fixed portion of the hourly volumetric price). We present results focused primarily on 2030, forecasting electricity prices under both low and high-cost scenarios, to inform longer-term tariff design considerations. We design tariffs by starting with 2019 prices that were calculated according to CalFUSE guidance (CPUC, 2022) and that have been used in recent studies; these prices are all-in volumetric rates that vary by utility and are revenue-neutral to each customer class. They are developed by considering six electricity cost components that are allocated hourly based on system load indicators (gross and net load, and wholesale prices). These prices are forecasted to 2030 for low and high cost scenarios, considering recent trends in total electricity costs with and without years of substantial wildfire mitigation investments. These tariffs, which allocate all costs on an hourly basis, are considered our “Full” dynamic tariff design scenario, while two additional scenarios explore allocating a portion of costs as a flat volumetric charge: the “Medium” scenario allocates 50% of revenue dynamically (and keeps 50% flat), while the “Mild” scenario allocates 20% of revenue dynamically. The 20% dynamic allocation on the Mild scenario aims to represent a case where only the marginal operating costs of the grid are included in the dynamic price.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Controlling Air Conditioners for Frequency Regulation: A Real-World Example

Even though thermostatically controlled loads like air conditioners present a great potential for providing ancillary services to the electric power grid, the practical challenges associated with their real-time coordination have not received the necessary attention. In this work, we present a nondisruptive load control application, specifically, we demonstrate how real residential air conditioners can provide frequency regulation. Aggregate power adjustment is achieved by modifying the ON/OFF modes of the air conditioners. To account for both single and multi-zone houses, we extend the currently available techniques and develop an approach that can be used for controlling aggregations that include both types of houses. A discussion of the practical challenges encountered in our field experiments is provided, along with the hardware and software approaches we developed to circumvent them. Here, we argue that limitations of current thermostat APIs introduce significant challenges and are an impediment to widespread adoption of fast load control applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Game Theory Approaches for System-level Incentive Design

This report presents a generalized Stackelberg game framework for designing and evaluating financial incentives that enhance power system resilience through strategic deployment of distributed energy resources(DERs) under various contingencies. The proposed approach addresses the challenge of coordinating individual community investment decisions to meet system-wide resilience objectives. The framework is demonstrated in a three-community test system subjected to two transmission contingency scenarios: inter-community line failure (Case 1) and complete main grid disconnection (Case 2). In both cases, three incentive levels are compared: a Base case with no financial incentives, and low and high incentive cases. In Case 1, the Base case (no incentives) results in a total installed DER capacity of 217.2 MW, with no load shedding due to alternative routing, but community costs remain high. Increasing incentives raises DER deployment to 286.9 MW, lowers aggregate community costs by $22M annually, and completely avoids the need for costly new transmission line construction. In Case 2, the Base case results in 24.3 MWh of unserved load; introducing incentives eliminates all load shedding and ensures up to 89 MWh of battery storage is available for emergency reserve. These results demonstrate that targeted incentives can dramatically improve grid resilience and cost-effectiveness. The framework thus offers policymakers and system planners a robust tool to quantify and compare the effectiveness of incentive programs for multi-community transmission networks behavior, system resilience, and economic efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Medium and Heavy-Duty Electric Vehicle Infrastructure - Load Operations and Deployment (HEVI-LOAD) v1.0

In order to support the California state goals to reduce the carbon and pollution emissions (AB2127), The goal of this project (HEVI-Pro) is to project the charging infrastructure needs by future medium- and heavy- duty electric vehicles, and assess optimal deployment the infrastructure in California and provide grid impacts analysis. The MHDV projections will also consider transportation system and electric system interaction with light duty vehicles. The project consists of 2 approaches in general: top-down approach that takes aggregated MHDV adoptions as the inputs and provide the county-level projections of charging load profile and infrastructure need, and the bottom-up approach that that incorporates more granular (temporal, spatial and duty-cycle-specific) behaviors of a variety of MHDVs into activity simulations/optimizations for further analysis.

Wang, Bin↗

Alignment frustration in block copolymer films with block copolymer grafted TiO 2 nanoparticles under soft-shear cold zone annealing

Block copolymers (BCPs) have received significant attention as promising candidates for sequestering nanoparticles and fabrication of aligned nanostructures with optimal optical or electrical properties. We investigate the influence of static and dynamic thermal field on the alignment of polystyrene-block-poly(methyl methacrylate) (PS-b-PMMA) BCP morphology with the loading of novel poly(methyl methacrylate-block-Polystyrene) (PMMA-b-PS)-grafted-TiO 2 nanoparticles (BCP-g-TiO 2 ). Observation of characteristics IR peaks for PMMA and PS in BCP-g-TiO 2 nanoparticles and Transmission Electron Microscopy (TEM) results of the outer coating of core nanoparticle, validate the grafting to approach in synthesizing BCP-g-TiO 2 . In this work, we report that under the sharp dynamic thermal field, at low loading of BCP-g-TiO 2 , there is good dispersion of nanoparticles in unidirectionally aligned BCP matrix in film interior probed by GISAXS, while, at high nanoparticle loading (~10 wt%), there is local frustration in the unidirectional alignment of the BCP matrix due to aggregation of BCP-g-TiO 2 nanoparticles. However, Grazing incidence small angle X-ray scattering (GISAXS) shows clearly that the BCP films remain largely locally ordered at the domain scale, despite these large perturbations to long-range ordering even at high loading level, while bringing in new TiO 2 functionality to the BCP films, such as UVO absorptivity or biofouling prevention, important to potential new applications of such membranes.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Material Extrusion Printing of Poly(Acrylonitrile‐Styrene‐Acrylate) and Poly(Acrylonitrile‐Butadiene‐Styrene) Structures Reinforced with Poly(Phenylene Oxide) Additives for Improved Thermomechanical Properties and their Surface Analysis by Time‐of‐Flight Secondary Ion Mass Spectrometry

Fused filament fabrication offers the ability to 3D print complex geometries made from plastic filament materials; however, these parts are mechanically outperformed by parts created by traditional fabrication methods. To overcome this challenge, a high-performance polymer poly(2,6-dimethyl-1,4-phenylene oxide) (PPO) is incorporated as an additive into two common engineering thermoplastics, poly(acrylonitrile-styrene-acrylate) (ASA) and poly(acrylonitrile-butadiene-styrene) (ABS). Structures printed from these polymer blends are more mechanically robust compared to those prepared from the parent polymers, with low loading levels (1–5 wt%) of PPO improving the elastic strength by up to ≈30% relative to the parent terpolymers. Even at higher loading levels (10 and 20 wt% PPO), there is no evidence of additive aggregation in the model thin films, which is supported by compositional analysis of the copolymers and chemical analysis via time-of-flight secondary ion mass spectrometry. The enhancements in mechanical properties of ASA and ABS blends appear to be a consequence of homogeneous incorporation of the PPO additive. In conclusion, this work explores expanding materials-property space using miscible blends of engineering thermoplastics to improve mechanical performance as a general approach to overcoming challenges with parts created by melt-based material extrusion printing.

additive manufacturing↗

Developing and tuning a community scale energy model for a disadvantaged community

This work describes the development of a community-scale energy model for a mixed-use low-income community located in Huntington Beach, CA. An accurate community-scale energy model is useful for evaluating the use of limited capital resources used to invest in clean energy technologies. This work lays out the process of developing such a model while relying primarily on publicly available data and highlighting critical partnerships necessary for model development success. The primary contribution of this work is the demonstration of the process used to develop an accurate energy model for a disadvantaged community when minimal building and energy use data is available. The heart of the model is the physics-based community scale energy modeling platform URBANopt. Using a bottom-up load modeling approach, energy simulated energy use falls within 3% or less of aggregate annual utility data, and within 10% or less aggregate monthly utility data. The demonstrated model development and tuning process can be used by others to characterize other atypical communities, which may differ significantly from prototypical models.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Pore-Selective Fullerene Loading in a Porphyrin-Based Metal–Organic Framework Controls Photoinduced Charge-Transfer Dynamics

Building porous donor−acceptor networks based on host−guest interactions in metal organic frameworks (MOFs) provides unique opportunities for tuning charge separation in highly tailorable materials. Here we focus on installing electron-rich porphyrins and electron-deficient fullerene derivatives in the PCN-222 MOF using a solvent assisted ligand insertion (SALI) method. The fullerene is primarily bound in the large pore, where it is subject to distinct dielectric environments through dimethylformamide (DMF) and 1,4-dioxane solvent exchange. Following photoexcitation, sub-picosecond charge transfer involving initial exciplex population is observed, with different charge recombination pathways and lifetimes depending on solvent polarity through modulation of charge-transfer state energies. While the 1,4-dioxane environment yields charge recombination within 1 ns via local fullerene and porphyrin triplet state population, DMF results in charge recombination directly to the ground state on much longer time scales, including some lifetime components in the microsecond range. Fullerene loading influences these kinetics, and the potential for charge delocalization due to fullerene aggregation within the pores is evaluated by using molecular dynamics simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Physically Realistic Estimates of Electric Water Heater Demand Response Resource

Multiple grid integration studies have examined the value of demand response, including from water heaters, to bulk power systems. Common shortcomings of these studies include physically unrealistic assumptions. For example, studies often assume that all electric water heater load can be shed for up to an hour to provide capacity or contingency service, that all electric water heater load is shiftable, and that round-trip efficiencies for shifting service are 100%. Another issue is that simply summing up estimates of individual water heaters' flexibility bounds, an attractive idea for constructing the MW-scale resources necessary for direct inclusion in grid investment and operational models, can result in significant overestimates of actual resource, because, e.g., a water heater with the ability to reduce load may not be able sustain the reduction for as long as the aggregate model suggests is possible. This presentation demonstrates the impact of estimating the flexibility of electric water heaters with physically realistic models suitable for grid service analysis. Electric water heater flexibility representations are constructed based on ResStock simulations of New England. Specifically, we examine contingency resource (related to capacity, shed, and contingency reserve services) and energy shifting resource from electric resistance and heat pump water heaters. Different estimation methods are compared; and the surrogate models' event responses are validated against events directly simulated in EnergyPlus. We also demonstrate the impact of using electric water heaters for contingency reserves and energy shifting in detailed models of possible future ISO New England power systems.

building energy modeling↗

Short-term electricity load forecasting: Application-driven evaluation of machine learning models across spatial and temporal scales

As we transition towards a decarbonized economy, the integration of variable renewable energy resources and new demands (e.g., electric vehicles, heat pumps) into the electricity grid places unprecedented pressure on grid operators to effectively anticipate and manage peak load. In this context, machine learning algorithms are proving to be indispensable for accurate short-term load forecasting, a crucial task to address these challenges. This study benchmarks 6 machine learning algorithms, including three neural networks and three tree-based algorithms, across various levels of spatial aggregation and time horizons (1, 4, 8, 24, and 48 h). The central contribution of this work is the comparison and analysis of load forecasting models not only based on statistical metrics, but also based on a novel error metric, which evaluates the cost implications of forecast errors for power system stakeholders. Results show that tree-based models outperform neural networks, based on statistical metrics, and yield less skewed error distributions for most spatial scales. However, through the lens of the novel error metric, neural networks are the more competitive choice, especially for forecast horizons that exceed 8 h. The study concludes with actionable recommendations to grid operators and highlights the need for the development of error metrics that link forecasting accuracy to operational costs. To promote transparency and open science, the datasets and Python code are open-sourced via a supplementary repository.

Houben, Nikolaus↗

A novel large-scale EV charging scheduling algorithm considering V2G and reactive power management based on ADMM

Electric vehicle aggregators (EVAs) that utilize vehicle-to-grid (V2G) technologies can function as both controllable loads and virtual power plants, providing key energy management services to the distribution system operator (DSO). EVAs can also balance the grid’s reactive power as a virtual static VAR compensator (SVC) and provide voltage stability by utilizing advanced electric vehicle (EV) chargers that are capable of four-quadrant operations to provide reactive power management. Finally, managed charging can benefit EVAs themselves by minimizing power factor penalties in their electricity bills. In this paper, we propose a novel EV charging scheduling algorithm based on a hierarchical distributed optimization framework that minimizes peak load and provides reactive power compensation for the DSO by collaboration with EVAs that manage both the active and the reactive charging and discharging power of participating EVs. Utilizing the alternative direction method of multipliers (ADMM), the proposed distributed optimization approach scales well with increased EV charging infrastructure by balancing active and reactive power while decreasing computational burden. In our proposed hierarchical approach, each EVA schedules the active and reactive EV charging and discharging power for 1) reactive power compensation in order to minimize power factor penalty and electricity cost accrued by the EVA, 2) satisfaction of each EV’s energy demand at minimal charging cost, and 3) peak shaving and load management for the DSO. When compared with an uncoordinated charging model, the efficacy of this proposed model is successfully demonstrated through a 300% decreased peak EV load for the DSO, 28% lower electricity costs for EV users, and 98.55% smaller power factor penalty, along with 17.58% lower overall electricity costs, for EVAs. The performance of our approach is validated in a case study with 50 EVs at multiple EVAs in an IEEE 13-bus test case and compared the results with uncoordinated EV charging.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reducing Grid Costs while Abating Emissions: Opportunities for Flexible Building Loads

This study evaluates the value of technology-agnostic, shiftable flexible building loads in modeled 2030 and 2040 U.S. grids for four types of customers under three potential aggregated distributed energy resources programs. The value examined includes monetary value from providing grid services (e.g., energy, capacity, flexibility reserve, regulation reserve, contingency reserve) and from reducing greenhouse gas emissions. By comparing more than 845,164,800 simulated shifting opportunities, the study finds that the timing of consumption is critical for profit-driven customers. A program that is activated for 30 critical hours of system operation can result in to $73 per year in revenue for 1 kWh of shiftable load. Emission reduction, on the other hand, is best accumulated through a year-round program: 1 kWh of shiftable load can lead to up to 487.9 kg CO2e carbon reduction per year. The report also provides detailed insights on the trade-off between revenue and emissions, regional variation, short- versus medium- term value, and impacts from various building flexibility parameters, such as shifting window and dissipation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PC-RPL: Joint Control of Routing Topology and Transmission Power in Real Low-Power and Lossy Networks

We present PC-RPL , a transmission power-controlled IPv6 routing protocol for low-power and lossy wireless networks that significantly improves the end-to-end packet delivery performance under heavy traffic compared to the standard RPL. We show through actual design, implementation, and experiments that a multihop wireless network can achieve better throughput and routing stability when transmission power and routing topology are “jointly and adaptively” controlled. Our experiments show that the predominant “fixed and uniform” transmission power strategy with “link quality and hop distance”–based routing topology construction (i.e., RPL) loses significant bandwidth due to hidden terminal and load imbalance problems. We design an adaptive and distributed control mechanism for transmission power and routing topology, named PC-RPL , on top of the standard RPL routing protocol for hidden terminal mitigation and load balancing. We implement PC-RPL on real embedded devices and evaluate its performance on a 49-node multihop testbed. PC-RPL reduces total end-to-end packet losses by approximately sevenfold without increasing hop distance compared to RPL with the highest transmission power, resulting in 17% improvement in aggregate bandwidth and 64% improvement for the worst-case node by successfully alleviating both hidden terminal and load imbalance problems.

Computer Science↗

Residual fracture energy of natural and recycled aggregate concrete after exposure to high temperatures

Abstract Fracture energy ( G F ) represents the average total energy consumed in the whole process of crack propagation. Using one parameter of G F , it is not sufficient to describe the fracture behavior during crack stable and unstable propagation periods. In this study, the G F , stable fracture energy ( G FS ) and unstable fracture energy ( G FU ) of natural and recycled aggregate concrete (RAC) were investigated by using three‐point bending tests. Totally, 128 cubic specimens (100 mm × 100 mm × 100 mm) and 64 notched beams with size of 510 mm × 100 mm × 100 mm were manufactured to test the compressive strength ( f cu ), splitting tensile strength ( f t ), load–deflection (P‐δ), and load‐cracking mouth opening displacement (P‐CMOD) curves, considering different replacement levels (0%, 30%, 70%, and 100%) of recycled coarse aggregate (RA) and high temperatures exposure (20, 100, 200, and 300°C). The effects of RA substitutions and temperatures on basic mechanical properties, G F , G FS , and G FU were analyzed. The results demonstrated that the f cu , f t , and elastic modulus ( E ) decreased with the incremental temperature. The G FS of concrete with different RA substitutions first decreased and then increased, and the minimum value appeared at 200°C. The G F and G FU of concrete with different RA substitutions increased with the elevated temperature, and the increase rate decreased with RA substitutions. When the temperature is less than 100°C, the G F and G FU of concrete remained mostly unchanged with the increase of RA substitutions, while the temperature reached 200 and 300°C, the G F and G FU of concrete increased and decreased with the increase of RA substitutions, respectively.

Chen, Wei↗

Co-simulation Framework for Community-scale Building-grid Integration [SWR-21-75]

Distributed energy resources (DERs), including rooftop solar, energy storage, and flexible loads, are gaining popularity as costs decline and as building owners and utilities realize their benefits. DERs can improve distribution system efficiency, help prevent the need for expensive grid upgrades, and increase the resilience of local communities. However, they can also cause difficulties in grid operations and can require controls to achieve their benefits. To address this challenge, NREL researchers have developed a community-scale solution that assesses the impacts of DERs and their control strategies on a distribution system. The framework has been shown to reduce solar photovoltaic (PV) curtailment to 0%, mitigate the adverse impact of solar variability on the distribution voltage, and provide up to 5-day critical load support during emergency events. Utilizing 5 different modules representing the feeder, buildings, home energy management systems, an aggregator, and a utility controller, NREL expects this simulation technology to play a critical role in the continued integration of DERs. According to the Energy Information Administration (EIA), solar curtailments accounted for 94% of the total energy curtailed in the California Independent System Operator (CAISO) in 2020. By enabling Independent System Operators (ISOs) and utility operators to bring solar curtailments to 0%, the electrical grid can become less dependent on fossil-fueled power generation sources. NREL's co-simulation framework contains five major components: Distribution Feeder Model: describes the distribution feeder topology using OpenDSS, including the locations of all DERs. Residential Building Model: simulates a large number of buildings at a high resolution using OCHRETM. The model is equipped to control equipment based on signals from an external module. The model includes major household appliances such as HVAC and a water heater, non-dispatchable load models, a distributed PV system, and a home battery system. Home Energy Management System: optimizes the controls for the devices in a home using foreseeTM. The control can adjust based on the user preferences including cost, comfort, and convenience. In hierarchical control scenarios, where the houses follow signals from an aggregator, the home energy management system provides a flexibility band with a range of power and follows the dispatch signals received from aggregator. Community-Level Aggregator: solves for optimal energy dispatch based on the flexibility bands received from each home and the grid service signal received from the utility controller. Utility-Level Controller: provides grid signals for voltage control using Distributed Energy Resources (DERs), such as solar systems, in the community.

Balamurugan, Sivasathya Pradha↗

An Optimization-Based HVAC Load and PV Disaggregation Methodology With Contextual Supervision

Here, this letter presents an optimization-based Heating, Ventilation, and Air Conditioning (HVAC) and PV disaggregation approach. This letter builds on the previous works of authors, which discuss HVAC disaggregation strategy for aggregated levels without requiring sub-metered information. This letter expands on previous works to discuss optimization-based HVAC disaggregation by varying PV penetration scenarios with joint disaggregation of HVAC load and PV.

Analytics↗

Object-Oriented Controllable High-Resolution Residential Energy (OCHRE) (TM) Model

This presentation describes the OCHRE model as part of NREL's Powered By webinar series. OCHRE is a building energy modeling tool designed to model flexible loads in residential buildings. OCHRE includes detailed models and controls for flexible devices including HVAC equipment, water heaters, electric vehicles, solar PV, and batteries. It is designed to run in co-simulation with custom controllers, aggregators, and grid models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗