Validation of Universal Cryogenic Flow Boiling Correlations in Thermal Desktop for Liquid Methane and Liquid Nitrogen
Future in-space cryogenic architectures will depend on the ability to accurately model various stages of cryogenic propellant transfer and storage. Currently there is a need for more accurate, direct cryogenic data-anchored models for various boiling phenomena. This paper presents the implementation and validation of recently developed universal cryogenic flow boiling correlations for saturated flow boiling heat transfer coefficients (HTC) and critical heat flux (CHF) into the Thermal Desktop (SINDA/FLUINT) modeling software. The correlations are validated against steady state cryogenic flow boiling historical heated tube cases from liquid nitrogen and liquid methane experiments covering a wide range of inlet conditions, mass flux, and heat flux. Overall, Thermal Desktop with the new universal cryogenic flow boiling correlations demonstrates significant improvement in predictive performance for both wall temperature and CHF location compared to the Thermal Desktop model with built-in correlations when both are compared to the data.