Lubricant For Use In Liquid Oxygen

Inexpensive grease, Braycote 640 AC-MS (or equivalent), increases operating lifetimes of ball bearings in liquid-oxygen turbopump. Improved grease stored and supplied very efficiently.

Beatty, Robert F.↗

Effects of Initial Geometric Imperfections On the Non-Linear Response of the Space Shuttle Superlightweight Liquid-Oxygen Tank

The results of an analytical study of the elastic buckling and nonlinear behavior of the liquid-oxygen tank for the new Space Shuttle superlightweight external fuel tank are presented. Selected results that illustrate three distinctly different types of non-linear response phenomena for thin-walled shells which are subjected to combined mechanical and thermal loads are presented. These response phenomena consist of a bifurcation-type buckling response, a short-wavelength non-linear bending response and a non-linear collapse or "snap-through" response associated with a limit point. The effects of initial geometric imperfections on the response characteristics are emphasized. The results illustrate that the buckling and non-linear response of a geometrically imperfect shell structure subjected to complex loading conditions may not be adequately characterized by an elastic linear bifurcation buckling analysis, and that the traditional industry practice of applying a buckling-load knock-down factor can result in an ultraconservative design. Results are also presented that show that a fluid-filled shell can be highly sensitive to initial geometric imperfections, and that the use a buckling-load knock-down factor is needed for this case.

Nemeth, Michael P.↗

Space Shuttle Orbiter Atlantis Liquid Oxygen Prevalve Detent Roller Cracking Investigation

During routine inspections of the Space Shuttle's Main Propulsion System (MPS) Liquid Oxygen (LO2) pre-valve, the mechanism provided to maintain the valve in the open position was found cracked. The mechanism is a Vespel roller held against the valve visor by a stack of Belleville springs. The roller has been found cracked 3 times. All three instances were in the same valve in the same location. There are 6 pre-valves on each orbiter, and only one has exhibited this problem. Every-flight inspections were instituted and the rollers were found to be cracked after only one flight. Engineers at Marshall Space Flight Center, Johnson Space Center and Kennedy Space Center worked together to determine a solution. There were several possible contributors to the failure: a mis-aligned visor, an out of specification edge with a sharp radius, an out of specification tolerance stack up of a Belleville spring stack that caused un-predicted loads on the Vespel SP-21 roller, and a dimple machined into the side of the roller to indicate LO2 compatibility that created a stress riser. The detent assembly was removed and replaced with parts that were on the low-side of the tolerance stack up to eliminate the potential for high loads on the detent roller. After one flight, the roller was inspected and showed fewer signs of wear and no cracks.

Holleman, Elizabeth↗

Critical Heat Flux of Liquid Hydrogen, Liquid Methane, and Liquid Oxygen: A Review of Available Data and Predictive Tools

Available experimental data dealing with critical heat flux (CHF) of liquid hydrogen (LH2), liquid methane (LCH4), and liquid oxygen (LO2) in pool and flow boiling are compiled. The compiled data are compared with widely used correlations. Experimental pool boiling CHF data for the aforementioned cryogens are scarce. Based on only 25 data points found in five independent sources, the correlation of Sun and Lienhard (1970) is recommended for predicting the pool CHF of LH2. Only two experiments with useful CHF data for the pool boiling of LCH4 could be found. Four different correlations including the correlation of Lurie and Noyes (1964) can predict the pool boiling CHF of LCH4 within a factor of two for more than 70% of the data. Furthermore, based on the 19 data points taken from only two available sources, the correlation of Sun and Lienhard (1970) is recommended for the prediction of pool CHF of LO2. Flow boiling CHF data for LH2 could be found in seven experimental studies, five of them from the same source. Based on the 91 data points, it is suggested that the correlation of Katto and Ohno (1984) be used to predict the flow CHF of LH2. No useful data could be found for flow boiling CHF of LCH4 or LO2. The available databases for flow boiling of LCH4 and LO2 are generally deficient in all boiling regimes. This deficiency is particularly serious with respect to flow boiling.

Multi-Phase Flow↗

Critical Heat Flux of Liquid Hydrogen, Liquid Methane, and Liquid Oxygen: A Review of Available Data and Predictive Tools

Available experimental data dealing with critical heat flux (CHF) of liquid hydrogen (LH 2 ), liquid methane (LCH 4 ), and liquid oxygen (LO 2 ) in pool and flow boiling are compiled. The compiled data are compared with widely used correlations. Experimental pool boiling CHF data for the aforementioned cryogens are scarce. Based on only 25 data points found in five independent sources, the correlation of Sun and Lienhard (1970) is recommended for predicting the pool CHF of LH 2 . Only two experiments with useful CHF data for the pool boiling of LCH 4 could be found. Four different correlations including the correlation of Lurie and Noyes (1964) can predict the pool boiling CHF of LCH 4 within a factor of two for more than 70% of the data. Furthermore, based on the 19 data points taken from only two available sources, the correlation of Sun and Lienhard (1970) is recommended for the prediction of pool CHF of LO 2 . Flow boiling CHF data for LH 2 could be found in seven experimental studies, five of them from the same source. Based on the 91 data points, it is suggested that the correlation of Katto and Ohno (1984) be used to predict the flow CHF of LH 2 . No useful data could be found for flow boiling CHF of LCH 4 or LO 2 . The available databases for flow boiling of LCH 4 and LO 2 are generally deficient in all boiling regimes. This deficiency is particularly serious with respect to flow boiling.

Multi-Phase Flow↗

Space Shuttle Orbiter Atlantis Liquid Oxygen Pre-Valve Detent Roller Cracking Investigation

During routine inspections of the Space Shuttle s Main Propulsion System Liquid Oxygen (LO2) pre-valve, the mechanism provided to maintain the valve in the open position was found cracked. The mechanism is a Vespel roller held against the valve visor by a stack of Belleville springs. The roller has been found cracked 3 times. All three instances were in the same valve in the same location. There are 6 pre-valves on each orbiter, and only one has exhibited this problem. Every-flight inspections were instituted and the rollers were found to be cracked after only one flight. Engineers at Marshall Space Flight Center, Johnson Space Center, and Kennedy Space Center worked together to determine a solution. There were several possible contributors to the failure: a misaligned visor, an out-of-specification edge with a sharp radius, an out-of-specification tolerance stack up of a Belleville spring stack that caused un-predicted loads on the Vespel SP-21 roller, and a dimple machined into the side of the roller to indicate LO2 compatibility that created a stress riser. The detent assembly was removed and replaced with parts that were on the low side of the tolerance stack up to eliminate the potential for high loads on the detent roller. After one flight, the roller was inspected and showed fewer signs of wear and no cracks.

Holleman, Elizabeth↗

Lightweight Thermal Insulation for a Liquid-Oxygen Tank

A proposed lightweight, reusable thermal-insulation blanket has been designed for application to a tank containing liquid oxygen, in place of a non-reusable spray-on insulating foam. The blanket would be of the multilayer-insulation (MLI) type and equipped with a pressure-regulated nitrogen purge system. The blanket would contain 16 layers in two 8-layer sub-blankets. Double-aluminized polyimide 0.3 mil (.0.008 mm) thick was selected as a reflective shield material because of its compatibility with oxygen and its ability to withstand ionizing radiation and high temperature. The inner and outer sub-blanket layers, 1 mil (approximately equals 0.025 mm) and 3 mils (approximately equals 0.076 mm) thick, respectively, would be made of the double-aluminized polyimide reinforced with aramid. The inner and outer layers would provide structural support for the more fragile layers between them and would bear the insulation-to-tank attachment loads. The layers would be spaced apart by lightweight, low-thermal-conductance netting made from polyethylene terephthalate.

Willen, G. Scott↗

Liquid Oxygen (LO2) propellant conditioning concept testing

Marshall Space Flight Center (MSFC) and industry contractors have undertaken activities to develop a simplified liquid oxygen (LO2) propellant conditioning concept for future expendable launch vehicles. The objective of these activities is to reduce operations costs and timelines and to improve safety of these vehicles. The approach followed has been to identify novel concepts through system level studies and demonstrate the feasibility of these concepts through small-scale and full-scale testing. Testing will also provide data for design guidelines and validation of analytical models. Four different concepts are being investigated: no-bleed, low-bleed, use of a recirculation line, and helium (He) bubbling. This investigation is being done under a Joint Institutional Research and Development (JIRAD) program currently in effect between MSFC and General Dynamics Space Systems (GDSS). A full-scale test article, which is a facsimile of a propellant feed duct with an attached section to simulate heat input from a LO2 turbopump, will be tested at the Cold Flow Facility at MSFC's West Test Area. Liquid nitrogen (LN2), which has similar properties to LO2, will be used in place of LO2 for safety and budget reasons. Work to date includes design and fabrication of the test article, design of the test facility and initial fabrication, development of a test matrix and test procedures, initial predictions of test output, and heat leak calibration and heat exchanger tests on the test article. The tests for all propellant conditioning concepts will be conducted in the summer of 1993, with the final report completed by October, 1993.

Perry, Gretchen L. E.↗

Developmental problems and their solution for the Space Shuttle main engine alternate liquid oxygen high-pressure turbopump: Anomaly or failure investigation the key

The Space Shuttle main engine (SSME) alternate high-pressure liquid oxygen pump experienced synchronous vibration and ball bearing life problems that were program threatening. The success of the program hinged on the ability to solve these development problems. The design and solutions to these problems are engirded in the lessons learned and experiences from prior programs, technology programs, and the ability to properly conduct failure or anomaly investigations. The failure investigation determines the problem cause and is the basis for recommending design solutions. For a complex problem, a comprehensive solution requires that formal investigation procedures be used, including fault trees, resolution logic, and action items worked through a concurrent engineering-multidiscipline team. The normal tendency to use an intuitive, cut-and-try approach will usually prove to be costly, both in money and time and will reach a less than optimum, poorly understood answer. The SSME alternate high-pressure oxidizer turbopump development has had two complex problems critical to program success: (1) high synchronous vibrations and (2) excessive ball bearing wear. This paper will use these two problems as examples of this formal failure investigation approach. The results of the team's investigation provides insight into the complexity of the turbomachinery technical discipline interacting/sensitivities and the fine balance of competing investigations required to solve problems and guarantee program success. It is very important to the solution process that maximum use be made of the resources that both the contractor and Government can bring to the problem in a supporting and noncompeting way. There is no place for the not-invented-here attitude. The resources include, but are not limited to: (1) specially skilled professionals; (2) supporting technologies; (3) computational codes and capabilities; and (4) test and manufacturing facilities.

Ryan, R.↗

Subscale Composite Liquid Oxygen Tank Testing

Lockheed Martin Space Systems Company recently completed a two-year fabrication and test program on subscale composite liquid oxygen (LO2) tanks. The goals of this program included the development of fabrication and inspection techniques, cryogenic acceptance testing of composite articles, and demonstrating oxygen compatibility under launch vibration loads. Two subscale diameter test bottles were fabricated using a proprietary Lockheed Martin material, known as LM21C03. The bottles were then inspected using an array of NDE techniques and then put through a cryogenic acceptance test program at Lockheed Martin. A NASA/Lockheed Martin test team then subjected a composite bottle to testing at an X-33 vibration profile for 15 minutes at use pressure. The tests were run at various LO2 fill levels, with and without intentionally added debris. All tests were successful in that the composite bottle showed no signs of ignition or combustion as a result of the vibration testing. This test program is an important bridge between coupon-level and subcomponent LO2 compatibility tests and full-scale composite LO2 tank use.

Graf, Neil A.↗

Liquid oxygen dicting cleaned by falling film method

Principle of a vertical falling film is used to clean contaminated large diameter and length liquid oxygen /LOX/ cylindrical ducting. The cleaning cycle is performed by flowing trichloroethylene in a falling film down a vertically mounted duct for approximately one hour.

Paul, H. I.↗

Cable Feedthrough Between Liquid Oxygen And Ambient

Encapsulant and back pressure provide double protection. Cable-feedthrough tube between ambient air and interior of vessel containing liquid oxygen protects external instrumentation and cable from oxygen. Cable in tube surrounded by potting compound. Provides flow of gaseous nitrogen to dilute oxidant and makes it harmless in case of leakage through crack in potting compound.

Myers, Don A.↗

Theoretical Performance of Liquid Hydrogen with Liquid Oxygen as a Rocket Propellant

Theoretical rocket performance for both equilibrium and frozen composition during expansion was calculated for the propellant combination liquid hydrogen and liquid oxygen at four chamber pressures (60, 150, 300, and 600 lb/sq in. abs) and a wide range of pressure ratios (1 to 4000) and oxidant-fuel ratios (1.190 to 39.683). Data are given to estimate performance parameters at chamber pressures other than those for which data are tabulated. The parameters included are specific impulse, specific impulse in vacuum, combustion-chamber temperature, nozzle-exit temperature, molecular weight, molecular-weight derivatives, characteristic velocity, coefficient of thrust, ratio of nozzle-exit area to throat area, specific heat at constant pressure, isentropic exponent, viscosity, thermal conductivity, Mach number, and equilibrium gas compositions.