Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “level sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A 1 GHz Oscillator-Type Active Antenna

Wireless sensors are desired for monitoring aircraft engines, automotive engines, industrial machinery, and many other applications. The most important requirement of sensors is that they do not interfere with the environment that they are monitoring. Therefore, wireless sensors must be small, which demands a high level of integration. Sensors that modulate an oscillator active antenna have advantages of small size, high level of integration, and lower packaging cost. Several types of oscillator active antennas have been reported. Ip et al. demonstrated a CPW line fed patch antenna with a feedback loop [1]. No degradation in performance was noticed without a ground plane. A GaAs FET was used in an amplifier/oscillator-based active antenna [2]. An oscillator based on a Cree SiC transistor was designed and characterized in [3]. This paper reports the integration of the SiC Clapp oscillator to a slotline loop antenna.

Jordan, Jennifer L.↗

BOREAS Level-3a Landsat TM Imagery: Scaled At-sensor Radiance in BSQ Format

For BOREAS, the level-3a Landsat TM data, along with the other remotely sensed images, were collected in order to provide spatially extensive information over the primary study areas. This information includes radiant energy, detailed land cover, and biophysical parameter maps such as FPAR and LAI. Although very similar in content to the level-3s Landsat TM products, the level-3a images were created to provide users with a more usable BSQ format and to provide information that permitted direct determination of per-pixel latitude and longitude coordinates. Geographically, the level-3a images cover the BOREAS NSA and SSA. Temporally, the images cover the period of 22-Jun-1984 to 30-Jul-1996. The images are available in binary, image-format files. With permission from CCRS and RSI, several of the full-resolution images are included on the BOREAS CD-ROM series. Due to copyright issues, the images not included on the CD-ROM may not be publicly available. See Sections 15 and 16 for information about how to acquire the data. Information about the images not on the CD-ROMs is provided in an inventory listing on the CD-ROMs.

Nickerson, Jaime↗

BOREAS Level-3s SPOT Imagery: Scaled At-sensor Radiance in LGSOWG Format

For BOReal Ecosystem-Atmosphere Study (BOREAS), the level-3s Satellite Pour l'Observation de la Terre (SPOT) data, along with the other remotely sensed images, were collected in order to provide spatially extensive information over the primary study areas. This information includes radiant energy, detailed land cover, and biophysical parameter maps such as Fraction of Photosynthetically Active Radiation (FPAR) and Leaf Area Index (LAI). The SPOT images acquired for the BOREAS project were selected primarily to fill temporal gaps in the Landsat Thematic Mapper (TM) image data collection. CCRS collected and supplied the level-3s images to BOREAS Information System (BORIS) for use in the remote sensing research activities. Spatially, the level-3s images cover 60- by 60-km portions of the BOREAS Northern Study Area (NSA) and Southern Study Area (SSA). Temporally, the images cover the period of 17-Apr-1994 to 30-Aug-1996. The images are available in binary image format files. Due to copyright issues, the SPOT images may not be publicly available.

Strub, Richard↗

A fault tolerant approach to state estimation and failure detection in nonlinear systems

The design problem considered in the present investigation involves a nonlinear discrete time stochastic system where replicated sensors provide redundant observations of inputs and outputs of the system, compensate for sensor 'normal operating' bias levels, and generate reliable estimates for the plant states in the presence of possible sensor failures. The resulting fault tolerant design should utilize inherent analytical redundancy and be capable of detecting many different types and levels of sensor failures. In addition, it should have minimal complexity. In connection with these goals, a sensor fault tolerant system design methodology is developed. The performance of the considered approach to an application is discussed, taking into account the design of a sensor fault tolerant system using analytic redundancy for the Terminal Configured Vehicle research aircraft in a microwave landing system environment.

Lancraft, R. E.↗

A Comparison of Wind Speed Data from Mechanical and Ultrasonic Anemometers

This study compared the performance of mechanical and ultrasonic anemometers at the Eastern Range (ER; Kennedy Space Center and Cape Canaveral Air Force Station on Florida's Atlantic coast) and the Western Range (WR; Vandenberg Air Force Base on California's Pacific coast). Launch Weather Officers, forecasters, and Range Safety analysts need to understand the performance of wind sensors at the ER and WR for weather warnings, watches, advisories, special ground processing operations, launch pad exposure forecasts, user Launch Commit Criteria (LCC) forecasts and evaluations, and toxic dispersion support. The current ER and WR weather tower wind instruments are being changed from the current propeller-and-vane (ER) and cup-and-vane (WR) sensors to ultrasonic sensors through the Range Standardization and Automation (RSA) program. The differences between mechanical and ultrasonic techniques have been found to cause differences in the statistics of peak wind speed in previous studies. The 45th Weather Squadron (45 WS) and the 30th Weather Squadron (30 WS) requested the Applied Meteorology Unit (AMU) to compare data between RSA and current sensors to determine if there are significant differences. Approximately 3 weeks of Legacy and RSA wind data from each range were used in the study, archived during May and June 2005. The ER data spanned the full diurnal cycle, while the WR data was confined to 1000-1600 local time. The sample of 1-minute data from numerous levels on 5 different towers on each range totaled more than 500,000 minutes of data (482,979 minutes of data after quality control). The 10 towers were instrumented at several levels, ranging from 12 ft to 492 ft above ground level. The RSA sensors were collocated at the same vertical levels as the present sensors and typically within 15 ft horizontally of each another. Data from a total of 53 RSA ultrasonic sensors, collocated with present sensors were compared. The 1-minute average wind speed/direction and the 1-second peak wind speed/direction were compared.

Short, D.↗

An Analysis of Peak Wind Speed Data from Collocated Mechanical and Ultrasonic Anemometers

This study compared peak wind speeds reported by mechanical and ultrasonic anemometers at Cape Canaveral Air Force Station and Kennedy Space Center (CCAFS/KSC) on the east central coast of Florida and Vandenberg Air Force Base (VAFB) on the central coast of California. Launch Weather Officers, forecasters, and Range Safety analysts need to understand the performance of wind sensors at CCAFS/KSC and VAFB for weather warnings, watches, advisories, special ground processing operations, launch pad exposure forecasts, user Launch Commit Criteria (LCC) forecasts and evaluations, and toxic dispersion support. The legacy CCAFS/KSC and VAFB weather tower wind instruments are being changed from propeller-and-vane (CCAFS/KSC) and cup-and-vane (VAFB) sensors to ultrasonic sensors under the Range Standardization and Automation (RSA) program. Mechanical and ultrasonic wind measuring techniques are known to cause differences in the statistics of peak wind speed as shown in previous studies. The 45th Weather Squadron (45 WS) and the 30th Weather Squadron (30 WS) requested the Applied Meteorology Unit (AMU) to compare data between the RSA ultrasonic and legacy mechanical sensors to determine if there are significant differences. Note that the instruments were sited outdoors under naturally varying conditions and that this comparison was not designed to verify either technology. Approximately 3 weeks of mechanical and ultrasonic wind data from each range from May and June 2005 were used in this study. The CCAFS/KSC data spanned the full diurnal cycle, while the VAFB data were confined to 1000-1600 local time. The sample of 1-minute data from numerous levels on five different towers on each range totaled more than 500,000 minutes of data (482,979 minutes of data after quality control). The ten towers were instrumented at several levels, ranging from 12 ft to 492 ft above ground level. The ultrasonic sensors were collocated at the same vertical levels as the mechanical sensors and typically within 15 ft horizontally of each another. Data from a total of 53 RSA ultrasonic sensors, collocated with mechanical sensors were compared. The 1- minute average wind speed/direction and the 1-second peak wind speed/direction were compared.

Short, David A.↗

BOREAS Level-1B TIMS Imagery: At-sensor Radiance in BSQ Format

The Boreal Ecosystem-Atmospheric Study (BOREAS) Staff Science Aircraft Data Acquisition Program focused on providing the research teams with the remotely sensed satellite data products they needed to compare and spatially extend point results. For BOREAS, the Thermal Infrared Multispectral Scanner (TIMS) imagery, along with other aircraft images, was collected to provide spatially extensive information over the primary study areas. The Level-1b TIMS images cover the time periods of 16 to 20 Apr 1994 and 06 to 17 Sep 1994. The system calibrated images are stored in binary image format files. The TIMS images are available from the Earth Observing System Data and Information System (EOSDIS) Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).

Hall, Forrest G.↗

BOREAS Level-1B MAS Imagery At-sensor Radiance, Relative X and Y Coordinates

For BOReal Ecosystem-Atmosphere Study (BOREAS), the MODIS Airborne Simulator (MAS) images, along with the other remotely sensed data, were collected to provide spatially extensive information over the primary study areas. This information includes detailed land cover and biophysical parameter maps such as fraction of Photosynthetically Active Radiation (fPAR) and Leaf Area Index (LAI). Collection of the MAS images occurred over the study areas during the 1994 field campaigns. The level-1b MAS data cover the dates of 21-Jul-1994, 24-Jul-1994, 04-Aug-1994, and 08-Aug-1994. The data are not geographically/geometrically corrected; however, files of relative X and Y coordinates for each image pixel were derived by using the C-130 INS data in a MAS scan model. The data are provided in binary image format files.

Strub, Richard↗

Nonlinear effects of a modal domain optical fiber sensor in a vibration suppression control loop for a flexible structure

Recently, a modal domain optical fiber sensor has been demonstrated as a sensor in a control system for vibration suppression of a flexible cantilevered beam. This sensor responds to strain through a mechanical attachment to the structure. Because this sensor is of the interferometric type, the output of the sensor has a sinusoidal nonlinearity. For small levels of strain, the sensor can be operated in its linear region. For large levels of strain, the detection electronics can be configured to count fringes. In both of these configurations, the sensor nonlinearity imposes some restrictions on the performance of the control system. In this paper we investigate the effects of these sensor nonlinearities on the control system, and identify the region of linear operation in terms of the optical fiber sensor parameters.

Lindner, D. K.↗

Sensor Fusion for a Network of Processes/Systems with Highly Autonomous Sensors

This paper describes a distributed sensor-data-fusion paradigm and theory based on a previously developed theory to model sensors as highly autonomous units. Generic procedures are defined to reason and make decisions at the qualitative level. This facilitates distribution of intelligence ( code and hardware) to the sensor level and peer-to-peer communication among sensors, controllers, and other devices in the system.

Figueroa, Fernando↗

Aircraft instrumentation system for the remote sensing of carbon monoxide

A light twin-engine aircraft has been instrumented with a carbon monoxide remote gas sensor system and test flown over the Southern Lake Michigan basin during August, 1976. The remote sensor is based on the gas filter correlation technique. The radiance levels from the sensor along with the data on the surface temperature, air temperature, dewpoint, and altitude were digitized and recorded on seven-track magnetic tape. Air samples were collected at various altitudes over selected sites for later analysis of carbon monoxide concentration and comparison with the inferred concentration from the remote sensor. The values of carbon monoxide obtained from the air samples and the values inferred from the remote sensor for data collected over water are in good agreement.

Beck, S. M.↗

Prototype development and test results of a continuous ambient air monitoring system for hydrazine at the 10 ppb level

A Hydrazine Vapor Area Monitor (HVAM) system is currently being field tested as a detector for the presence of hydrazine in ambient air. The MDA/Polymetron Hydrazine Analyzer has been incorporated within the HVAM system as the core detector. This analyzer is a three-electrode liquid analyzer typically used in boiler feed water applications. The HVAM system incorporates a dual-phase sample collection/transport method which simultaneously pulls ambient air samples containing hydrazine and a very dilute sulfuric acid solution (0.0001 M) down a length of 1/4 inch outside diameter (OD) tubing from a remote site to the analyzer. The hydrazine-laden dilute acid stream is separated from the air and the pH is adjusted by addition of a dilute caustic solution to a pH greater than 10.2 prior to analysis. Both the dilute acid and caustic used by the HVAM are continuously generated during system operation on an "as needed" basis by mixing a metered amount of concentrated acid/base with dilution water. All of the waste water generated by the analyzer is purified for reuse by Barnstead ion-exchange cartridges so that the entire system minimizes the generation of waste materials. The pumping of all liquid streams and mixing of the caustic solution and dilution water with the incoming sample are done by a single pump motor fitted with the appropriate mix of peristaltic pump heads. The signal to noise (S/N) ratio of the analyzer has been enhanced by adding a stirrer in the MDA liquid cell to provide mixing normally generated by the high liquid flow rate designed by the manufacturer. An onboard microprocessor continuously monitors liquid levels, sample vacuum, and liquid leak sensors, as well as handles communications and other system functions (such as shut down should system malfunctions or errors occur). The overall system response of the HVAM can be automatically checked at regular intervals by measuring the analyzer response to a metered amount of calibration standard injected into the dilute acid stream. The HVAM system provides two measurement ranges (threshold limit value (TLV): 10 to 1000 parts per billion (ppb)/LEAK: 100 ppb to 10 parts per million (ppm)). The LEAK range is created by dilution of the sulfuric acid/hydrazine liquid sample with pure water. This dual range capability permits the analyzer to quantify ambient air samples whose hydrazine concentrations range from 10 ppb to as high as 10 ppm. The laboratory and field prototypes have demonstrated total system response times on the order of 10 to 12 minutes for samples ranging from 10 to 900 ppb in the lLV mode and is greater than 2 minutes for samples ranging from 100 to 1300 ppb in the LEAK mode. Service intervals of over 3 months have been demonstrated for continuous 24 hour/day, 7 day/week usage. The HVAM is made up of a purged cabinet that contains power supplies, RS422 signal transmission capabilities, a UPS, an on-site warning system, and a Line Replaceable Unit (LRU). The LRU includes all of the liquid flow system, the analyzer, the control/data system microprocessor and assorted flow and liquid-level sensors. The LRU is mounted on a track slide system so it can be serviced inplace or totally removed and quickly exchanged with another calibrated unit, thus minimizing analyzer downtime. Once an LRU is removed from an analyzer enclosure, it can be brought to a laboratory facility for complete calibration and periodic maintenance.

Meneghelli, Barry↗

Systems level polarization modeling of multispectral space sensors

The 2-percent polarization sensitivity specification in many of NASA's Earth Observing System sensors has motivated Santa Barbara Research Center (SBRC) to develop computer programs that model the polarization characteristics of optical systems. In support of the Moderate Resolution Imaging Spectroradiometer program, SBRC has developed an analytical tool which unites the completed 3D lens design and coating designs to accurately predict an optical system's polarization characterization compensators, nonnormal incidence reflection and transmission from dichroic beam splitters and protected silver mirrors are analyzed without the need for proprietary coating prescriptions. The phenomenon of diattenuation and phase change are treated using the Jones matrix formalism.

Wells, Conrad↗

BOREAS RSS-18 Level-1B AVIRIS Imagery: At-Sensor Radiance in BIL Format

These data were collected and processed by the BOREAS RSS-18 team at NASA JPL. Data were acquired for BOREAS with NASA's AVIRIS. This optical sensor measures images that consist of spectra from 400 to 2500 nm at 10-nm sampling. These spectra are acquired as images with 20-meter spatial resolution, 11-km swath width and up to 800-km length. The measurements are spectrally, radiometrically, and geometrically calibrated. Spatially, the data are focused on the BOREAS NSA and SSA near Thompson, Manitoba, and Candle Lake, Saskatchewan, Canada, respectively. AVIRIS data were collected in 1994 during the Thaw campaign at the NSA and SSA, at the SSA in IFC-1, and at the NSA and SSA in both IFC-2 and IFC-3. In 1996, AVIRIS was deployed in the winter and summer campaigns in the SSA only. The data files are available on a CD-ROM (see document number 20010000884) or from the Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).

Newcomer, Jeffrey A.↗

NASA Tech Briefs, July 2009

Topics covered include: Dual Cryogenic Capacitive Density Sensor; Hail Monitor Sensor; Miniature Six-Axis Load Sensor for Robotic Fingertip; Improved Blackbody Temperature Sensors for a Vacuum Furnace; Wrap-Around Out-the-Window Sensor Fusion System; Wide-Range Temperature Sensors with High-Level Pulse Train Output; Terminal Descent Sensor Simulation; A Robust Mechanical Sensing System for Unmanned Sea Surface Vehicles; Additive for Low-Temperature Operation of Li-(CF)n Cells; Li/CFx Cells Optimized for Low-Temperature Operation; Number Codes Readable by Magnetic-Field-Response Recorders; Determining Locations by Use of Networks of Passive Beacons; Superconducting Hot-Electron Submillimeter-Wave Detector; Large-Aperture Membrane Active Phased-Array Antennas; Optical Injection Locking of a VCSEL in an OEO; Measuring Multiple Resistances Using Single-Point Excitation; Improved-Bandwidth Transimpedance Amplifier; Inter-Symbol Guard Time for Synchronizing Optical PPM; Novel Materials Containing Single-Wall Carbon Nanotubes Wrapped in Polymer Molecules; Light-Curing Adhesive Repair Tapes; Thin-Film Solid Oxide Fuel Cells; Zinc Alloys for the Fabrication of Semiconductor Devices; Small, Lightweight, Collapsible Glove Box; Radial Halbach Magnetic Bearings; Aerial Deployment and Inflation System for Mars Helium Balloons; Steel Primer Chamber Assemblies for Dual Initiated Pyrovalves; Voice Coil Percussive Mechanism Concept for Hammer Drill; Inherently Ducted Propfans and Bi-Props; Silicon Nanowire Growth at Chosen Positions and Orientations; Detecting Airborne Mercury by Use of Gold Nanowires; Detecting Airborne Mercury by Use of Palladium Chloride; Micro Electron MicroProbe and Sample Analyzer; Nanowire Electron Scattering Spectroscopy; Electron-Spin Filters Would Offer Spin Polarization Greater than 1; Subcritical-Water Extraction of Organics from Solid Matrices; A Model for Predicting Thermoelectric Properties of Bi2Te3; Integrated Miniature Arrays of Optical Biomolecule Detectors; A Software Rejuvenation Framework for Distributed Computing; Kurtosis Approach to Solution of a Nonlinear ICA Problem; Robust Software Architecture for Robots; R4SA for Controlling Robots; Bio-Inspired Neural Model for Learning Dynamic Models; Evolutionary Computing Methods for Spectral Retrieval; Monitoring Disasters by Use of Instrumented Robotic Aircraft; Complexity for Survival of Living Systems; Using Drained Spacecraft Propellant Tanks for Habitation; Connecting Node; and Electrolytes for Low-Temperature Operation of Li-CFx Cells.

Source record↗

BOREAS Level-3s Landsat TM Imagery Scaled At-sensor Radiance in LGSOWG Format

For BOReal Ecosystem-Atmosphere Study (BOREAS),the level-3s Landsat Thematic Mapper (TM) data, along with the other remotely sensed images,were collected in order to provide spatially extensive information over the primary study areas. This information includes radiant energy,detailed land cover, and biophysical parameter maps such as Fraction of Photosynthetically Active Radiation (FPAR) and Leaf area Index (LAI). CCRS collected and supplied the level-3s images to BOREAS for use in the remote sensing research activities. Geographically,the bulk of the level-3s images cover the BOREAS Northern Study Area (NSA) and Southern Study Area (SSA) with a few images covering the area between the NSA and SSA. Temporally,the images cover the period of 22-Jun-1984 to 30-Jul-1996. The images are available in binary,image-format files.

Nickeson, Jaime↗

Characterization and comparison of Landsat-4 and Landsat-5 Thematic Mapper data

Engineering analyses of Thematic Mapper (TM) image data have been conducted, giving particular attention to the radiometric characterization of the sensor. While the data in general were found to be excellent, anomalies do exist in the data from both Landsat-4 and Landsat-5 TM. A summary is provided of the Landsat-4 TM image data. The present paper concentrates, however, on recent analyses of Landsat-5 TM data and comparisons of the radiometry of the two sensors. One of the specific topics covered is within-line droop, a phenomenon whereby the signal levels of the sensor change systematically during the active scan. Attention is also given to scan-correlated level shifts, an effect which raises or lowers the signal level of all pixels in a scan line or set of scan lines. A comparison of Landsat-4 and Landsat-5 radiometric corrections is also discussed.

Metzler, M. D.↗

Thermal-vacuum testing and in-situ optical alignment measurements of the HALOE telescope/sun sensor assembly

Design features, test data and projected performance levels of the telescope/sun sensor assembly for the Halogen Occultation Experiment (HALOE) on board the Upper Atmosphere Research Satellite are described. HALOE will gather data on stratospheric chemical species with an IR telescope pointed through the atmosphere at the sun during occultation periods. The pointing accuracy will need to be 1 arcmin elevation and 1.6 arcmin azimuthal. Adjustments of the gimbaled instrument are guided by a sun sensor and its associated electronics. The components were subjected to thermal-vacuum, optical boresight stability tests and the data generated were compared with a finite element model of the telescope and sun sensor. The tests consisted of exposure to various thermal gradients while the telescope and sun sensor alignments were tracked by optical deflectometry. The thermal behavior was compared with predictions made with a finite difference model. Alignments were within tolerable ranges and the thermal behavior model was concluded valid for predicting the thermal behavior of orbiting instruments.

Foss, R. A.↗