Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “leak test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Recent Developments in Hydrogeologic Applications for Strain Tensor Analyses

Changes in fluid pressure deform porous media and this effect occurs in a variety of hydrogeologic processes, from the change in storage during pumping or injection to fluctuations in water levels caused by barometric pressure. We have developed instruments for measuring small strains in porous media, and we have used the resulting strain data to evaluate well testing, hydraulic fracturing, manual loading at the ground surface, and ambient hydrologic processes, like rainfall and evaporation. A particularly important application is the use of strain tensor data measured at shallow depths to analyze well tests or hydraulic fractures conducted at much greater depths. An early demonstration of this technique was conducted at the North Avant Field north of Tulsa, Oklahoma, where Pennsylvanian sandstone creates a confined aquifer and oil reservoir at a depth of 530m. We have showed that the strains caused by injecting into the aquifer could be measured at a depth of 30m and used to evaluate the properties of the aquifer. We recently expanded the array of strainmeters at the North Avant Field by deploying three more instruments at shallow depth (30m) along with a deep instrument at 520m depth in the winter, 2021. The deep instrument is deployed in shale caprock slightly above the aquifer. To our knowledge, the deep strainmeter at the North Avant Field is the deepest strainmeter ever deployed and this required refining methods originally developed for shallow deployments. The instrument was lowered to depth on oil field tubing and cemented in place using techniques and materials developed for use in oil wells. Optical fiber used to communicate with the instrument was cemented in the annulus on the outside of tubing. This is significant because the techniques we used could readily be extended to greater depth, suggesting that strainmeters can be deployed over a wide range of depths for monitoring critical subsurface processes. For example, it suggests that strainmeters could be deployed through the caprock to monitor for leaks from underlying CO2 storage reservoirs. The strainmeter array at the North Avant Field has been used to characterize deformation during a series of injection tests in the spring and summer, 2021. All the new strainmeters respond to pumping, and the strainmeters we installed earlier also responded. To our knowledge, this is the first application of well testing in a deep aquifer that was monitored by an array of strainmeters—our earlier work used strainmeters at a single location. We are currently analyzing the strain data using an analytical solution, a proxy-based Bayesian inversion algorithm, and other methods. Strainmeter data has also been used to characterize periodic pumping tests by us and Riley Blais. A periodically varying pumping rate causes both hydraulic head and strain signals that vary with the same period as the pumping. The peaks and troughs of the head in monitoring wells lag behind the peaks and troughs of the head in the pumping well, and this lag time increases with distance from the pumping well. The lag time of the pressure and the distance to the monitoring well can be used in a simple analysis to estimate the hydraulic diffusivity of the aquifer. The lag time determined from strain data can be used to estimate aquifer properties using the same analysis that works for the pressure only for strain data measured at particular locations. That is because the strain field in a confining unit advances upward, laterally and then downward even though the pressure in the underlying aquifer only advances laterally, according to our recent simulations. We have field data showing that a small periodic signal superimposed on an injection rate at the North Avant Field will create a periodic strain signal at shallow strainmeters. The field data and the recent simulations suggest that including a periodic component to injection or pumping and then monitoring the resulting strain signal could be a way to monitor the subsurface.

Murdoch, Larry↗

Design of the DUNE APATF cryogenic system

Fermi National Accelerator Laboratory (FNAL) is developing the international Long- Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE) to advance neutrino science. The flagship of the DUNE project consists of a large particle detector constructed one-mile (1.6 km) beneath the surface at the Sanford Underground Research Facility (SURF) in Lead, SD. The SURF detector is the largest of its type ever built and is comprised of four cryostats totaling 70,000 tons of liquid argon (LAr) to record neutrino interactions with unprecedented precision. Each cryostat houses a detector, the first includes 150 Anode Panel Assemblies (APA) submersed within 17,500 tons of LAr. Before installing 150 APA within the SURF detector they will be cryogenically cooled to nominally 90 K at the APA Test Facility (APATF) utilizing nitrogen flows. The APATF cryogenic system is entirely located one-mile underground at the SURF facility and includes nominally 13 kW of refrigeration at 80 K, cryogenic transfer lines, APA test cryostats, a cryogenic control system, and various control and pressure safety elements to ensure performance and safety requirements are achieved. The APATF preliminary design is in progress and major considerations include an efficient, costeffective mechanism to deliver the required refrigeration to the APATF underground, support of rigid testing intervals to support the DUNE operating schedule, temperature stability of the APA and electronics within cryostats, efficient cryogenic system operation to minimize heat leak and/or liquid nitrogen consumption, thermo-mechanical stability and flexibility of components, and pressure safety of the APATF cryogenic system. Installation and integration of the APATF cryogenic system within the footprint and to adjacent sub-systems is also discussed.

43 PARTICLE ACCELERATORS↗

Field Testing of a Mixed Potential IoT Sensor Platform for Methane Quantification

Emissions of CH 4 from natural gas infrastructure must urgently be addressed to mitigate its effect on global climate. With hundreds of thousands of miles of pipeline in the US used to transport natural gas, current methods of surveying for leaks are inadequate. Mixed potential sensors are a low cost, field deployable technology for remote and continuous monitoring of natural gas infrastructure. We demonstrate for the first time a field trial of a mixed potential sensor device coupled with machine learning and internet-of-things platform at Colorado State University’s Methane Emissions Technology Evaluation Center (METEC). Emissions were detected from a simulated buried underground pipeline source. Sensor data was acquired and transmitted from the field test site to a remote cloud server. Quantification of concentration as a function of vertical distance is consistent with previously reported transport modelling efforts and experimental surveys of methane emissions by more sophisticated CH 4 analyzers.

03 NATURAL GAS↗

Open Radiation Monitoring: Conceptual System Design

The Open Radiation Monitoring (ORM) Project seeks to develop and demonstrate a modular radiation detection architecture designed specifically for use in arms control treaty verification (ACTV) applications that will facilitate rapid development of trusted systems to meet the needs of potential future treaties. Development of trusted systems to support potential future treaties is a complex and costly endeavor that typically results in a purpose-built system designed to perform one specific task. The majority of prior trusted system development efforts have relied on the use of commercial embedded computers or microprocessors to control the system and process the acquired data. These processors are complex, making authentication and certification of measurement systems and collected data challenging and time consuming. We believe that a modular architecture can be used to reduce more complex systems to a series of single-purpose building blocks that could be used to implement a variety of detection modalities with shared functionalities. With proper design, the functionality of individual modules can be confirmed through simple input/output testing, thereby facilitating equipment inspection and in turn building trust in the equipment by all treaty parties. Furthermore, a modular architecture can be used to control data flow within the measurement system, reducing the risk of "hidden switches" and constraining the amount of sensitive information that could potentially be inadvertently leaked. This report documents a conceptual modular system architecture that is designed to facilitate inspection in an effort to reduce overall authentication and certification burden. As of publication, this architecture remains in a conceptual phase and additional funding is required to prove out the utility of a modular architecture and test the assumptions used to rationalize the design.

61 RADIATION PROTECTION AND DOSIMETRY↗

Molten Salt Loop Operational Experience and Test Campaigns in FY24

The Facility to Alleviate Salt Technology Risks (FASTR) at the US Department of Energy (DOE) Oak Ridge National Laboratory (ORNL) was developed to demonstrate technology for high-temperature chloride salt systems (Figure 1). FASTR is primarily constructed using alloy C-276 and is designed to operate at temperatures of up to 725°C. The facility is loaded with 250 kg of NaCl-KCl-MgCl 2 salt. This salt provides a relevant test environment for de-risking technology while avoiding the costs and hazards associated with beryllium-based or uranium-bearing salts. The facility’s major components include a centrifugal pump for salt circulation, an air-based heat exchanger to reject heat, a suite of instrumentation, and trace heating to prevent salt freezing. The salt was purified in 2020 and 2022, and the pumped loop first operated in December 2022. FASTR is a unique US capability for high-temperature molten halide salt testing. FASTR’s scale, co located purification system, and relatively large power (465 kW) differentiates it from other testing systems. Furthermore, access to the DOE-supported facility and efficient communication of results— which are generally disseminated publicly—distinguish FASTR as being broadly significant throughout the molten salt reactor community. FASTR is similar to ORNL’s Liquid Salt Test Loop (LSTL), although FASTR contains chloride-based salt instead of the fluoride-based salt (LiF-NaF-KF) found in LSTL. Furthermore, FASTR is approximately 2× larger than LSTL in terms of pipe size and length, power, salt volume, flow rate, and number of thermocouples. The LSTL first operated in 2016. At the end of FY23, there was a suspected gas leak in the LSTL that halted operation. At the start of FY24, a leak in the LSTL pump’s tank gas space was confirmed. Because the gas-space leak prevented operation of LSTL, FY24 efforts were focused on operation of FASTR. This report summarizes the progress made during FY24 in support of the DOE Office of Nuclear Energy (DOE-NE) work package, AT-24OR070202 Salt Loop and Capability for Testing Sensors and Off Gas Components.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Advancing Development of Emissions Detection (Final Report)

This document is the final report to the U.S. Department of Energy (DOE for contract DE-FE0031873) awarded to Colorado State University (CSU). CSU and partners at Harrisburg University of Science and Technology, University of Texas Arlington, and University of Texas at Austin organized several testing rounds to provide knowledge focused on advancing the detection capabilities of emissions monitoring devices. With this funding opportunity the research group began by establishing the Advancing the Development of Emission Detection (ADED) program, with the goal focused on enhancing the accuracy, reliability, and field applicability of methane detection technologies. This effort aimed to address the critical challenges of identifying and quantifying methane emissions while enabling industry stakeholders to meet regulatory compliance and environmental sustainability goals. The program engaged with industry, government, and technology stakeholders to promote adoption and consensus on testing techniques for methane detection solutions. Methane, a potent greenhouse gas, contributes significantly to global warming, and the oil and natural gas (O&G) sector is a primary source of methane emissions. Regulatory measures such as leak detection and repair (LDAR) programs have been implemented to address emissions. However, traditional LDAR approaches, reliant on handheld and component-level measurements, are resource-intensive. To address these limitations and move with evolving regulations, advanced methane technologies are emerging. These solutions include ground-based sensors, mobile systems (e.g., drones, vehicles, and aircraft), and satellite-based platforms. They offer innovative capabilities for autonomous monitoring, larger spatial coverage, and emission quantification using methods such as tracer gas techniques and inverse modeling with Gaussian plume analysis. The ADED program began with creating protocols for methane controlled release (CR) testing these continuous monitoring (CM) and survey technologies that detect and monitor methane emissions at O&G facilities. The protocols were then implemented throughout testing of CM and survey devices at CSU’s Methane Emissions Technology Evaluation Center (METEC) facility from 2021 through 2024. As apart of the protocol, solutions that tested under the ADED program installed their solutions at METEC, documented their system under test, and provided detection reports to the METEC team for analysis. The METEC team would provide the solutions with analyzed reports of their emissions and ground truth data of the releases conducted during their testing session. Under the ADED program, CMs were also tested at O&G facilities for a six week test run of challenge release (ChR) releases. The findings from the ADED program underscore the critical role of collaborative research and innovation in tackling methane emissions, offering a pathway for the oil and gas sector to achieve significant environmental and economic benefits. Results from METEC testing saw improvement of performance and accuracy across all solutions over the extent of the ADED experiments. The results also showed a variance in CM solution performance between CRs and ChRs. That variance pushed the team to further analyze the differences between CR testing environments and field conditions. With the drive from regulations and that variance in field conditions, the ADED team began designing a new CR testing protocol and additions to the METEC testing facility. The METEC team is furthering the progress made through the ADED program with awarded funding from DE-FE0032276. This funding pushes the development of METEC’s addition with new equipment, allowing for an updated facility layout. METEC still facilitates for traditional facilities, with a legacy pad, while expanding an new design based on how O&G infrastructure has Final Report - Contract Number: DE-FE0031873 been changed over the last decade. Throughout the ADED program the team has also been working with international partners to ensure staying in the trend globally. International partners have been essential in moving the new protocol forward to implement into CR testing at the METEC facility in Spring 2025.

42 ENGINEERING↗

Progress Towards the Validation of a new RELAP5-3D model of the High Temperature Test Facility

Validation is a key step in the development of any type of systems model. As the next generation of reactors approaches, the need for codes that have been validated for these new types of systems continues to grow. An example of a prominent option is the Reactor Excursion Leak Analysis Program (RELAP5-3D), developed by Idaho National Laboratory. This code was developed for the purpose of systems level thermal-hydraulic modeling of light water reactors (LWRS) and postulated transients that can occur in LWRS.RELAP5-3D has been substantially validated against LWR data. Due to its long history as a reactor safety analysis tool, there has been an effort to adapt RELAP5-3D for the purposes of advanced reactor concepts such as prismatic high-temperature gas-cooled reactors (HTGRs). However, RELAP5-3D has not nearly been validated and verified for HTGRs to the degree of LWRs, warranting verification and validation opportunities with computational benchmarks and existing experimental facilities. Examples of such facilities include the modular high-temperature gas-cooled reactor (MHTGR) 350 and the high temperature engineering test reactor (HTTR) from Japan. The MHTGR 350 is a benchmark design concept for code-to-code verification purposes; therefore, it does not provide any experimental data for validation opportunities The HTTR provides useful multiphysics validation data but does not have the in-core instruments to generate thermal-hydraulic experimental data to help with RELAP5-3D validation. Consequently, a facility that could provide key in-core temperatures for thermal-hydraulic validation was still needed. The High Temperature Test Facility (HTTF) is an integral effects facility for HTGR thermal hydraulics developed and operated by Oregon State University. HTTF represents ¼ length scale of the General Atomics MHTGR and is rated for a total power of 2.2 MW. Axially, the core consists of an upper and lower reflector and 10 blocks, numbered from bottom to top (Block 1 is right above lower reflector). The core is heated via graphite resistive heater rods, with respective channels distributed throughout the core. The primary coolant is helium and heat can radiate out of the core to the reactor cavity cooling system (RCCS), which is cooled by water. The primary purpose of the facility is to investigate pressurized conduction cooldown (PCC) and depressurized conduction cooldown (DCC) transients, which are also referred to as the pressurized and depressurized loss of forced cooling respectively. Two experiments were chosen to perform the validation study with a RELAP5-3D model of HTTF. These experiments are PG-27 (PCC) and PG-29 (DCC). These were chosen based off of the quality of available experimental data before and during the experiment which led to their inclusion in the HTGR Thermal Hydraulics Benchmark.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental and Computational Validation of a Novel Particle Flow Control Valve for CSP Systems

Particle-based Concentrated Solar Power (CSP) systems most often utilize the state-of-the art slide gate mechanism for particle flow control. The slide-gate was found to have a sensitivity of 0.354 g/s-mm, a measure of mass flow rate over actuation position [1]. Particle-based CSP developers have noted that the slide gate is conducive to particle lodging, leaking, and difficulty actuating under particle pressure as well as differential expansion of the gate from thermal cycling. The goal of this work is to design, develop and test a novel particle flow control device that can operate without any hindrance from these shortcomings.

14 SOLAR ENERGY↗

Design of a removable vacuum bellow restraint for RHIC vacuum vessels

In preparation for the rework of a RHIC Siberian snake for EIC, a DU7 cold section is being refurbished to replace the snake magnet before the RHIC run 25. There is a need to check the vacuum vessel leak tightness before tunnel installation, however the vacuum vessel original restraints have been removed. So there is a need to design a new removable bellow restraint for this vacuum testing. This report details the design and analysis done to ensure the safe operation of this bellow restraint.

43 PARTICLE ACCELERATORS↗

A Qualitative Strategy for Fusion of Physics into Empirical Models for Process Anomaly Detection

To facilitate the automated online monitoring of power plants, a systematic and qualitative strategy for anomaly detection is presented. This strategy is essential to provide credible reasoning on why and when an empirical versus hybrid (i.e., physics-supported) approach should be used and to determine the ideal mix of these two approaches for a defined anomaly detection scope. Empirical methods are usually based on pattern, statistical, and causal inference. Hybrid methods include the use of physics models to train and test data methods, reduce data dimensionality, reduce data-model complexity, augment data, and reduce empirical uncertainty; hybrid methods also include the use of data to tune physics models. The presented strategy is driven by key decision points related to data relevance, simple modeling feasibility, data inference, physics-modeling value, data dimensionality, physics knowledge, method of validation, performance, data availability, and suitability for training and testing, cause-effect, entropy inference, and model fitting. The strategy is demonstrated through a pilot use case for the application of anomaly detection to capture a valve packing leak at the high-pressure coolant injection system of a nuclear power plant.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methane Quantification Performance of the Quantitative Optical Gas Imaging (QOGI) System Using Single-Blind Controlled Release Assessment

Quantitative optical gas imaging (QOGI) system can rapidly quantify leaks detected by optical gas imaging (OGI) cameras across the oil and gas supply chain. A comprehensive evaluation of the QOGI system’s quantification capability is needed for the successful adoption of the technology. This study conducted single-blind experiments to examine the quantification performance of the FLIR QL320 QOGI system under near-field conditions at a pseudo-realistic, outdoor, controlled testing facility that mimics upstream and midstream natural gas operations. The study completed 357 individual measurements across 26 controlled releases and 71 camera positions for release rates between 0.1 kg Ch 4 /h and 2.9 kg Ch 4 /h of compressed natural gas (which accounts for more than 90% of typical component-level leaks in several production facilities). The majority (75%) of measurements were within a quantification factor of 3 (quantification error of –67% to 200%) with individual errors between –90% and 831%, which reduced to –79% to +297% when the mean of estimates of the same controlled release from multiple camera positions was considered. Performance improved with increasing release rate, using clear sky as plume background, and at wind speeds ≤1 mph relative to other measurement conditions.

42 ENGINEERING↗

Design and Analysis of an Integrated Additively Manufactured Test Article for Plasma-Facing Components

Current plasma-facing components (PFCs) used in helium-cooled divertor modules are complex structures with tungsten tile, steel sleeve components, and cartridges, all assembled in a helium-cooled multiple jet (HEMJ) structure. The goal of this project is to simplify the complex PFC design using additive manufacturing techniques to create a single integrated tungsten test article. Apart from the flexibility this opens up in exploring a wide array of geometries for the article, having a single integrated article significantly reduces the number of joints and parts in the article, thus reducing chances of leaks. A process called electron beam melting has shown to produce very high-density samples and unique geometries, enabling HEMJ or similar designs. To validate and optimize this novel design, the model underwent a series of computational fluid dynamics and finite element analysis simulations to replicate steady-state heat flux in the divertors. The simulations presented in this study consider a steady-state base heat flux of 5 MW/m 2 , with water serving as the coolant. Future research will explore the use of helium as a coolant, simulate edge-localized-mode conditions, and include experimental validation. Since 3D-printed tungsten is anisotropic, the build direction versus build plane of the article are taken into consideration for the test article strength. Because of the high operating temperatures and low ductility of tungsten, thermal creep and brittle fracture are important failure mechanisms to consider. In conclusion, the cap is evaluated with various flow velocities and nozzle diameters, and an optimal design choice is made for which this cap will survive the divertor conditions with a conservative safety margin.

Divertor↗

Aerosol Envelope Sealing of New Residences

This project investigated the use of an aerosol-based sealing method to reduce air leakage of new homes in the United States. The process involves pressurizing the building while dispersing an aerosol sealant “fog” to the building interior. As air escapes the building through leaks in the envelope, the sealant particles are carried to the leaks where they make contact and stick, sealing the leaks. A standard blower door is used to facilitate the sealing process and to provide real-time feedback and a permanent record of the sealing. The technology is thus capable of simultaneously measuring, locating, and sealing leaks in a building automatically.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Double-Shell Tank Primary Bottom Visual Inspection Results - 20025

A pressing need for the Double-Shell Tank Integrity Program at Hanford is of the ability to inspect the bottom of the tanks. Though the DSTs' annulus spaces (the space between the internal and external tank walls) have been inspected visually since 1992 and with Ultrasonic Testing (UT) since 1996, inspections of the tank bottoms have been able to be conducted due to limitations of available technology, omitting about 40 percent of the tank surface below the maximum fill level from routine inspection. Visual inspections of the tank annulus have been conducted up to five times in some DSTs and portions of the annulus space for all of the DSTs has been inspected twice with UT. This region includes the walls of the primary tank and secondary liner along with accessible portions of the secondary liner bottom. Due to this lack of technology, the degradation of the primary tank bottom in Tank AY-102 was undetected until the tank leaked into its annulus space, confirmed in 2012. Since that time, WRPS has been working with the nondestructive examination community and the Pacific Northwest National Laboratory, to evaluate potential technologies to conduct these challenging remote inspections. Recent work has included the development, testing, and deployment of several remote visual inspection technologies to observe the condition of the primary tank bottom of the DSTs by leveraging air distribution slots in the refractory pad on which it rests. Robotic solutions to conduct this inspection were developed with a detailed understanding of the physical configuration and operational logistics. Understanding and subsequent communication of these details to vendors within the robotics and nondestructive examination community was a critical component to the successful production of these new tools. Throughout the FY16-FY18 years, vendors from nondestructive examination community were solicited for ideas to meet the tank bottom inspection challenge. Two tank bottom visual inspection solutions were then pursued to meet that challenge. Both tools were successfully deployed at Tank AP-107, and provided valuable visuals, never before obtained from the under tank environment of a double-shell tank. While there are minor opportunities for improvement identified with each system, general outcomes were overwhelmingly positive. Both systems were successfully able to navigate the refractory air slot pattern from the outer edge to the tank center and record video footage. The micro-crawler provided high quality and very stable footage through the air slot pattern, but took longer to deploy into the slots and traverse through them than the alternative system. The push-pull tethered camera was able to navigate all seven of its target air slots in a matter of a few hours, which included deployment, movement between slot entrances, and complete removal of the system from the annulus environment. Through these air slots, new information was gained about the tank bottom and refractory pad condition of tank AP-107, AP-106, AP-108, and AN-102. While some debris was noted in the air slots, including sand, chipped refractory, and construction materials, the refractory was found to be structurally stable and adequately supporting the primary tank bottom through the full diameter of the tank. Primary tank bottom steel exterior was found to be in good condition, free of ongoing or aggressive corrosion conditions. Looking toward the future, robotic access to and visual inspection of refractory air slots and the primary tank bottom steel has now proven viable. Incorporating periodic air slot inspections as a regular practice within the Double-Shell Tank Integrity Program is the next step, allowing trending of any changes in condition. As ultrasonic testing infrastructure was leveraged to complete the initial system deployments described in this report, it makes sense to adopt that same strategy for ongoing periodic examinations and deploy these primary tank bottom inspection tools alongside ultrasonic testing operations. Development of visual inspection tools to evaluate the primary tank bottom region of the double-shell tanks was planned as the first stage of inspection. Continued development of volumetric sensors and incorporation of these inspection tools into Hanford's ongoing Double-Shell Tank Integrity Program are the next steps, seeking to continuously expand understanding of asset integrity and remaining useful life. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reduced Order Model to Predict Dispersion of Flammable Refrigerant into a Space

As the HVAC&R industry mobilizes to deploy more low-GWP refrigerants, relevant standards are being continually reviewed and updated. Those include the general safety standards ISO 5149 and ASHRAE 15, and the equipment standards IEC and UL. The standards systematically set the allowable maximum amount of refrigerant that should be used in different equipment types and different applications. To do so, they rely on predictions of how a leaked refrigerant mass will disperse into a space. Dispersion characteristics, such as total flammable volume and its residence time, determine the risk associated with the presence of the flammable refrigerant. The standards have included provisions for the use of flammable refrigerants for approximately two decades. They relied on limited analytical analyses and test cases in their development. Dispersion of a refrigerant into a space is complex. Computational fluid dynamics (CFD) are the most accurate in predicting a given problem. However, CFD is computationally expensive and requires specialized expertise and resources and is not suitable for use by standards development working group as prediction tool. This paper presents the development of a reduced order model (ROM) that predicts the key dispersion characteristics relevant to the dispersion of a leaked refrigerant into a space for any combination of input variables. The inputs are the refrigerant release height, the total released refrigerant mass and its release flow rate, the refrigerant molecular weight, the ventilation flow rate, the floor area and height of the space, recirculation air flow rate, and the tightness of the space. The outputs are histograms of volume fraction of the room in prescribed concentration bins and the total mass of the refrigerant in each bin normalized by the total refrigerant charge at 13 prescribed simulation time stamps between 1 and 900 seconds. The ROM is constructed from a set of CFD simulations with carefully chosen combinations of input parameters. The selection if done using a multidimensional sparse grid which is a generalization of the classical tensor approach but offers additional flexibility and thus can be more carefully tuned towards a specific model. The tuning is done to improve the accuracy, measured in the difference between the output values of the ROM and the CFD model, while minimizing the computational cost, measured in number of CFD simulations which is orders of magnitude more expensive than the processing the training data.

Edwards, Dean↗

Thermal Hydraulic Experimental Test Article (FY21 Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time. Following installation of THETA into vessel #4, all data acquisition and control systems were brought online and commissioned at room temperature in the argon gas space of the empty vessel. The vessel zone 1 heaters were reinstalled and the flange was then insulated. The vessel 4 heaters were brought to a temperature of 100 °C and the THETA pump was jogged at 600 RPM to ensure it was functioning correctly. The secondary, AC Conduction based electromagnetic pump from CMI Novacast (product number CA-15) was ordered and will be delivered in late calendar year 2021. The custom designed permanent magnet based secondary flowmeter was designed, a drawing package and manufacturing specification created and quote requested from a machine shop. The intermediate heat exchanger design was completed and a drawing package is currently in progress. During the middle of calendar year 2021 the Building 308 sodium scrubber system was shut down in order to replaced some corroded piping and facilitate improvements on the system, thus requiring the sodium in METL to remain frozen. This has imposed a delay in filling vessel 4 with sodium to begin THETA testing. Sodium testing is expected to begin in early fiscal year 2022 as all THETA primary systems are operational.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Epoxy Sealant Self-leveling and Adhesion Test Report

The Hanford tank farms have 149 single shell tanks which were built between 1943 - 1964, and 28 double-shell tanks (DSTs) which were built between 1968 – 1986 (Tank Farms, 2020) which contain radioactive and chemical mixed waste. Many of the tanks have leaked, including DST AY-102 (Waste Tank Summary Report, 2023). As a result, methods of repairing or reinforcing double-shell storage tanks are being evaluated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of the Mobile Systems for Conditioning of Disused Sealed Radioactive Sources in Serbia - 20105

Sealed radioactive sources (SRS) are being used worldwide in the field of medicine, agriculture, industry and research. They can be found in mobile as well as stationary devices. SRS contains radioactive material that is (a) permanently sealed in a capsule or (b) closely bounded and in a solid form. The capsule or material of an SRS should be strong enough to maintain leak tightness under the conditions of use and purpose for which the source was designed, also in case of accidents. In this case only emitted radiation is utilized. Firstly, the hazard from external radiation has to be considered, but the possibility of contamination due to fracture of the capsule should not be disregarded. The radioactive sources are composed of the radiating isotope contained in the filling medium, the single or double isotope holder that partially or totally surrounds the filling medium, the outer cover that contains the parts mentioned above and the capsule closed airtightly by welding or using some other method. The capsule must be tested for leakage periodically. If the SRS is no longer needed (e.g. replaced by a different technique) or it becomes useless for the intended application (e.g. the activity becomes too weak, the equipment containing the source works poorly or becomes obsolete, the source is damaged or leaking) it is considered disused. Disused sealed radioactive sources (DSRS) are typically conditioned and disposed if a facility is available. If the disposal option is not available, conditioned DSRS should be stored under proper conditions. In some cases, the radionuclide(s) in DSRS can be recovered/recycled or the DSRS can be repurposed for other applications. Conditioning of DSRS ensures containment of the radioactive material, provides confinement for leaking sources, provides sufficient radiation shielding, reduces storage/disposal volume by allowing consolidation of multiple sources into a single storage/disposal container, facilitates transport operations and contributes to safety and security as well. Typically, conditioning technologies are deployed either as permanently installed stationary systems in centralized or mobile on-site waste processing facilities, or in a mobile configuration. Centralized stationary facilities provide a single processing location for multiple users that requires transport of the waste to the facility. On the other hand, mobile systems may be provided for the selection and application of the optimum technology for a specific waste stream (such as DSRS) by bringing the process to the point where the waste is generated. In addition, mobile systems could offer additional flexibility by sharing equipment among multiple waste generating sites for processing campaigns that vary in duration, from very short periods to several years. The term 'mobile processing system' refers to any radioactive waste processing system or component which is designed to be transportable and which is not considered permanently installed. Two mobile system for conditioning of disused sealed radioactive sources are developed in the Public Company Nuclear Facilities of Serbia. Development of these mobile systems was supported by SRB9005 national project via Technical Cooperation of the IAEA. The first mobile system, built inside the 20 feet ISO container, will be used for conditioning of DSRS category 3 to 5. The second mobile system, built inside the 7 m long vehicle (Iveco Daily Van), will be used for dismantling of ionizing smoke detectors mostly with Am-241 sources. Designs of the mobile systems were defined in cooperation with two companies from Belgium (Belgoprocess and Leniko) and a Croatian company Ekoteh as well as with the support of the IAEA experts. The generic safety assessment and operational procedures for the mobile systems are developed. Based on safety assessment the acceptance criteria and operational limits and conditions are established. Operational procedures include: (a) equipment and material requirements, (b) assembling procedure of the mobile unit, (c) procedure for acceptance of devices for dismantling and conditioning, (d) dismantling procedure for devices to recover the DSRS, (e) characterization of DSRS, (f) encapsulation procedure of DSRS, (g) disassembling procedure of the mobile unit, and (h) keeping records, identification and traceability. In addition, radiation safety, health safety, security and emergency preparedness plans are prepared. The generic safety assessment and operational procedures could be updated with site specific requirements, DSRS inventory, and different needs for future customers. Developed mobile systems could be used in all situations when it is feasible to perform conditioning of DSRS on the spot in the county and worldwide. Development of these mobile units was just the first step to create the Reference Center for Radioactive Waste Treatment and Disused Radioactive Sources Conditioning for Small Facilities which can become a regional training center in the future, and/or as a tool for comprehensive national search and secure programmes. In the next phases development of e-learning platforms and blended learning packages as well as application for the IAEA Qualified Technical Centre (QTC) for the management of DSRS is foreseen. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗