Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “leak”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Quantification of air leakage paths: a comparison of airflow and acoustic measurements

Today, the fan pressurization method is the most frequently used method to evaluate a building's airtightness. However, the localization and quantification of leaks remain difficult. In this paper, an acoustic method is introduced to estimate the leakage size of single leaks. Acoustic and airflow measurements were conducted and compared in laboratory tests within the same boundary conditions. This work aims to investigate if various leak sizes can be predicted using acoustic measurement methods. The test apparatus consists of two chambers, separated by a test wall. This wall represents a single characteristic air leakage path. Various types of wall structures with different slit geometries, wall thicknesses, and insulation materials were investigated. The acoustic measurements were performed with a sound source placed in one chamber and ultrasonic microphones located in both chambers. These results were compared to measured airflows through the test wall to provide estimates of uncertainty in the acoustic approach, which indicate a linear trend. Finally, these laboratory measurements were compared to the same measurements at a real office building. Finally, although the acoustic measurement uncertainty is still significant (greater than +/- 50%), the acoustic method has the potential to give an order of magnitude of single leak sizes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensitivity Analysis of Salt Storage Cavern Mechanical Integrity Test Parameters

This report examines the sensitivity of salt cavern Mechanical Integrity Tests (MIT) to uncertainties in key test parameters. MIT's are used by cavern operators to detect and quantify leak rates in access wells in underground salt storage caverns and involve a suite of measured and assumed parameters that have a direct impact on the sensitivity of the testing to detect actual leaks from the cavern storage system. Determining the sensitivity of the testing to these different parameters provides a basis for understanding the results from, and informing the design criteria for, this type of testing. Without fully understanding the sensitivity of the test to the testing parameters, it is possible that the test results may not accurately reflect the integrity of the cavern system; an actual leak may be missed, or an intact system may be interpreted as leaking. This report reviews the main parameters included in MITs and examines how selected changes in their values can impact test results. The deviations used in the sensitivity analyses were designed to be within the ranges believed to be similar to those which may be encountered during testing. The results show that small, plausible fluctuations in some of the parameters measured values can have a significant impact on the testing results. Of the parameters studied here, the sensitivity analyses showed the order of importance to be (from highest to lowest): nitrogen-oil interface depth measurement, well bore temperature, well head pressure, and finally the internal geometry of the testing interval.

42 ENGINEERING↗

Aerosol Envelope Sealing of New Residences

This project investigated the use of an aerosol-based sealing method to reduce air leakage of new homes in the United States. The process involves pressurizing the building while dispersing an aerosol sealant “fog” to the building interior. As air escapes the building through leaks in the envelope, the sealant particles are carried to the leaks where they make contact and stick, sealing the leaks. A standard blower door is used to facilitate the sealing process and to provide real-time feedback and a permanent record of the sealing. The technology is thus capable of simultaneously measuring, locating, and sealing leaks in a building automatically.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aerosol Envelope Sealing of New Residences

This project investigated the use of an aerosol-based sealing method to reduce air leakage of new homes in the United States. The process involves pressurizing the building while dispersing an aerosol sealant “fog” to the building interior. As air escapes the building through leaks in the envelope, the sealant particles are carried to the leaks where they make contact and stick, sealing the leaks. A standard blower door is used to facilitate the sealing process and to provide real-time feedback and a permanent record of the sealing. The technology is thus capable of simultaneously measuring, locating, and sealing leaks in a building automatically.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Progress Report on Model Development for the Transport of Aerosol Through Microchannels

Accuracy of consequence assessments could be improved by accounting for the leak path deposition of aerosol in the source term. Recent experimental measurements from Sandia (2018) provided evidence of partial microchannel plugging due to particulate deposition. This filtration effect is relevant to the source term assessments and it is not unreasonable to anticipate that aerosol deposition in more realistic geometries could even lead to complete plugging of the leak path. This report summarizes current progress (as of end of Q3 FY 2020) on the development of a phenomenological model of aerosol transport, deposition, and plugging through microchannels. The purpose is to introduce a generic, reliable numerical model for the prediction of aerosol transport, deposition, and plugging in leak paths while accounting for potential plugging formation. This report includes (1) an overview of recent additions and improvements on the recently developed numerical model to analyze the various deposition processes in leak paths, to provide quantitative estimates of penetration factors, and to gain an understanding of the variables that affect them and (2) a summary of recent benchmarking results of the model’s validity with recent experimental measurements from Sandia.

54 ENVIRONMENTAL SCIENCES↗

Progress Report of Alloy 709 Performance in Liquid Sodium

With improved high-temperature properties, Alloy 709 shows great potential for advanced reactor applications. To understand the effects of sodium on A709, small tensile specimens were machined from two commercial heats and subject to sodium exposure in two forced convection loops operated by Argonne. Thermal aging experiments were also conducted in parallel to isolate any sodium-specific effects. An increasing trend in yield strength and a decrease trend in ultimate tensile strength can be seen with the increasing exposure time, suggesting microstructural changes at these temperatures. Nonetheless, the thermally aged and sodium exposed samples behaved similarly, implying no sodium-specific effect at these temperatures. In contrast, 316H SS exposed to sodium at 650°C showed a strong sodium effect. The different responses of A709 and 316H SS to sodium exposure is of interest and requires additional effort to understand. The cold traps of the sodium loop were replaced early in FY23. During a maintenance operation, an unexpected sodium leak incident occurred at one of the sodium loops, triggering an emergency response. An investigation into the incident revealed that the leak happened at a VCR fitting on the recently replaced cold trap. The metal gasket of the leaked VCR fitting was not compressed sufficiently. A dimensional mismatch between the new component and old piping configuration was responsible for a significant misalignment. A new cold trap with improved design is in production. The new design provides additional flexibility and an access point for post-installation helium leak check and for venting of trapped gas. These design features will make the system more error-tolerant and the installation quality verifiable. A thermodynamic analysis was performed to understand the carburization-decarburization behavior of A709 in sodium environment. The equilibrium carbon activity in the alloy was evaluated with M 23 C 6 , TiC, and NbC. The carburization-decarburization boundary was calculated with different methods developed previously. The results suggests that A709 will be carburized in SMT-1 and SMT-2, and can be decarburized in low-carbon-activity environments such as EBR-II at temperatures above 620-650°C. Nonetheless, A709 should be less likely to be decarburized than 316H SS when exposed to the same low-carbon-activity environment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development Fiber Optic Distributed System for Direct Detection of Subsurface Gases Leakages

Carbon, natural gas, and hydrogen gas storage is an emerging solution to safeguard us against pollution, support goals of negative carbon emission, and protect sources of renewable energy. Properly constructed storage wells provide a virtually impervious barrier to any unintended subsurface transmission. The ability to ensure the long-term integrity of such wells is vital to the success of any storage operation and be successful in the public eyes. Therefore, robust monitoring of any gas migration into the subsurface is highly sought. A fiber-optic distributed chemical sensor (DCS) enables monitoring of long-term well integrity along its depth, ensuring the success of any storage operation and bolsters public acceptance of the safety of the reservoir via leak early detection. The same technique can be applied to gas monitoring in pipeline networks and nuclear stockpile monitoring applications. Fiber based Raman spectroscopy enables DCS, as optical fibers can be deployed in virtually any environment and relay spectroscopic information over long distances back to the user. Hollow core fibers (HCF) make excellent DCSs as the air core of the fiber allows gas from the environment to diffuse into the core, which interacts with the laser signal that is carried in the air core. This work builds upon the previous LDRD project, Fiber Optic System for Direct Detection of Carbon Dioxide Leakage in Carbon Storage Wells (21-FS-003), in which the feasibility of Raman spectroscopy detection of Carbon Dioxide (CO2) in HCF detection was demonstrated. We mitigated the risk of this DCS technology by establishing and completing five objectives. The first objective was to model and optically characterize HCF uptake of CO2, establishing the relationship between HCF length, gas diffusion time, detectable gas concentration, and measured Raman intensity. In objective two, we developed a fiber core drilling recipe to enable additional diffusion ports in the fiber core and established a method for maintaining fiber strength and integrity post drilling. Objective three characterized the drilled fibers against the undrilled fibers, establishing the differences in the gas mechanics and optical properties and provided parameters to iterate the drilling process. In objective four, a fusion splicing technique was developed to join the HCF to conventional single-mode fibers, localizing the gas detection point at the drilled HCF hole, emulating a DCS. Lastly, objective five was the testing of the sensor in Edgar Mines at Colorado School of Mines on a CO2 pipeline with a simulated leak, to showcase the ability to detect CO2 leaks. This capstone result showed CO2 leak detection in < 10 minutes, raising the technology readiness level of HCF segments as deployable DCS.

organic↗

Seawater Acidification and Bubble Plume Dispersion from Accidental Subsea CO 2 Pipeline Rupture: A Multiphase CFD Study

If a CO 2 reservoir or transmission pipeline were to leak, both the surrounding ecology and maritime traffic safety could be put at risk. To better understand and prepare for this risk, multiphase Computational Fluid Dynamics (CFD) models were built in ANSYS Fluent to capture the behavior of a leak once it enters the water. A 3D Eulerian–Eulerian model was used for validation, while a simplified 2D model was applied to simulate conditions at a 50-m depth. The models integrate bubble dynamics, gas holdup, CO 2 dissolution, dissolved species transport, and seawater acidification into a unified CFD framework. Mass transfer was calculated using the Hughmark correlation, and local seawater temperature and salinity were factored in to determine dissociation behavior and the relevant Henry’s Law constant. To confirm the 3D model’s accuracy, results were checked against two experimental datasets: the QICS field study and the Hauser Tank experiments. The team also modeled a hypothetical release scenario at the High Island 10L site and compared the results with earlier published work. The results show that at a depth of 50 m, the surrounding water column can completely absorb a CO 2 release at a rate of 35 kg/s, since the gas dissolves into the seawater as it rises toward the surface. Beyond confirming this mitigation capacity, the simulations shed light on how a leak would actually unfold in the environment, including the shape and movement of the rising bubble plume, how much CO 2 dissolves along the way, and the resulting shifts in seawater pH and pCO 2 . Together, this provides a practical framework for assessing how CO 2 leaks could affect marine environments in the Gulf of Mexico.

54 ENVIRONMENTAL SCIENCES↗

Gas-mapping 3D imager measurement techniques and method of data processing

Measurement approaches and data analysis methods are disclosed for combining 3D topographic data with spatially-registered gas concentration data to increase the efficiency of gas monitoring and leak detection tasks. Here, the metric for efficiency is defined as reducing the measurement time required to achieve the detection, or non-detection, of a gas leak with a desired confidence level. Methods are presented for localizing and quantifying detected gas leaks. Particular attention is paid to the combination of 3D spatial data with path-integrated gas concentration measurements acquired using remote gas sensing technologies, as this data can be used to determine the path-averaged gas concentration between the sensor and points in the measurement scene. Path-averaged gas concentration data is useful for finding and quantifying localized regions of elevated (or anomalous) gas concentration making it ideal for a variety of applications including: oil and gas pipeline monitoring, facility leak and emissions monitoring, and environmental monitoring.

Thorpe, Michael↗

Smartphone application for visualizing building air leakage

Annually, unwanted air leakage through building envelopes accounts for 4 quads of energy consumption in the United States, which translates to about 10% of total building energy consumption. Locating and sealing leakage sites is crucial fordecreasing building energy consumption. Smartphones are ubiquitous and contain sophisticated cameras and highperformance processors that could be employed to visualize air leakage using the background-oriented schlieren imaging technique, making leak detection cheaper and easier. This technique requires a textured and high-contrast background such as a brick or concrete masonry unit wall, a building air leak that has a temperature difference compared with the ambient air, and an imaging system. This work focuses on using smartphones as the imaging system to visualize air leakages. The paper discusses application development and the results of testing to determine leakage visualization performance as a function of leak temperature. The results show that leaks with a temperature difference greater than 16°C compared with the ambient air temperature were visualized using existing smartphones.

Boudreaux, Philip [ORNL] (ORCID:0000000229564665)↗

Automated, Unmanned Detection and Quantification of Fugitive Methane Emissions

Compressor stations used to move natural gas are one of the largest sources of fugitive methane emissions in the midstream sector, accounting for approximately 50% of all fugitive emissions (Zimmerle et al., 2015). This problem is most widespread at reciprocating compressors (Subramanian et al., 2015) where faulty seals are a key contributor to methane emissions (Johnson et al., 2015). As such, there is a significant need for a robust technology that could provide an early indication of an unexpected emission. Equally important, the technology needs to be able to account for biogenic versus anthropogenic sources of methane. One means of indirectly making this determination, is to leverage optical technologies that can autonomously pinpoint the source of such leaks. This presentation discusses recent work funded by the U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL), focused on the development of an innovative remote sensing technology that can reliably and autonomously detect fugitive methane emissions in near real-time, using computer vision and deep learning. The technology called the Smart Methane Leak Detection (SLED/M) system was initially developed to monitor facilities such as compressor stations in a stationary, pan-tilt-zoom configuration. The system has recently been adapted to monitor facilities from an unmanned aerial system (UAS). The speed and maneuverability of UAS platforms are attractive to leak detection and repair program operators, but introduce several challenges. Many existing methane detection algorithms rely on mostly static backgrounds becoming unusable with motion. In addition, top-down views of fugitive methane emissions present differently in Optical Gas Imagers (OGI) compared to looking across the plume. Our work has focused on overcoming these challenges, enhancing the operators ability to detect methane emissions, and pinpoint their sources. Another recent adaptation to SLED/M is the ability to quantify methane emissions using passive sensors (OGI, thermal camera), environmental conditions, plume modeling, and deep learning. SLED/M advances the state-of-the-art for methane emission detection and quantification by focusing on three key critical criteria for effective methane emission mitigation: (1) autonomy (no need for a human to be in the loop), (2) high reliability (low false alarm rates), and (3) real-time performance. Results from this work will be presented.

03 NATURAL GAS↗

A Modeling-Based Flammable Risk Treatment of Refrigerant Leakage from a Commercial R-290 Refrigeration Machine

Because of serious concerns about global warming, manufacturers have started phasing out high global warming potential (GWP) refrigerants in commercial refrigeration equipment (e.g., R-134a). As a potential replacement, propane (R-290) is an environmentally friendly refrigerant for commercial refrigeration equipment because its GWP is only three. However, propane is flammable and is therefore classified as a Class A3 refrigerant per ASHRAE Standards, so safety is a very important consideration when propane-based equipment is designed and deployed in buildings. In the event of a refrigerant leak, flammability of the refrigerant depends on the refrigerant’s local concentration, which is highly affected by the indoor air environment, including temperature and air flow. In this study, a ventilation system attached to a commercial R-290 refrigeration device was designed to eliminate the flammability risk. Moreover, a computational fluid dynamics (CFD) model was developed to investigate the refrigerant leak, thereby evaluating effects of the ventilation system. The CFD model can visualize the flammable zones owing to the leak.

42 ENGINEERING↗

An approach for spent nuclear fuel containment integrity verification using gas tagging

Verification of containment integrity is required for spent nuclear fuel (SNF) managed by the commercial nuclear industry and U.S. Department of Energy (DOE), especially after extended storage. Certain SNF storage systems, such as the DOE road-ready dry storage system, hold several packaged containments within a welded over-canister. These packaged containments are called Department of Energy Standard Canisters (DOESCs). DOESC leakage identification is challenging because their containment boundary cannot be accessed for testing and their contents (i.e., SNF and fill gas) are often similar. There are concerns that this could result in costly characterization and repackaging operations of DOE road-ready dry storage systems if compromised DOESCs are suspected. Here, to address these concerns, this paper presents an approach for applying a gas tagging process using xenon to uniquely identify compromised inaccessible containments following extended storage. The containments considered for this application are seven DOESCs, each packaged within a single over-canister. Two different SNF loading configurations from the Advanced Test Reactor and Fort Saint Vrain nuclear power plant are considered. These configurations are used to represent research reactor aluminum-clad spent nuclear fuel (ASNF) and TRi-structural ISOtropic (TRISO) SNF types. Results for this application show that for ASNF and TRISO type fuels for which the selected fuels are representative, the volume of taggant required at loading is determined primarily by the lower detection limit and leak rate of taggant from a compromised DOESC, rather than the amount of fission-generated xenon in the loaded fuel. While the application presented is suited for larger leaks, smaller leaks could be detected by modifying certain design parameters. This gas tagging approach can also be applied to other DOE containments and advanced reactor SNF storage systems.

07 - ISOTOPES AND RADIATION SOURCES↗

Effect of initial water saturation on the performance of fracturing fluids with and without polyallylamine under simulated EGS conditions

Objectives/Scope: StimuFrac (US Patents 9,873,828 B2 and 9,447,315 B2), a CO 2 - reactive polymer aqueous solution [polyallylamine (PAA) 1wt% in water] combined with CO 2 , can be used as a potentially less water-intensive fracturing fluid for enhanced geothermal systems (EGS). Our previous results show that in hot dry rock (HDR), PAA/CO 2 fracturing fluids outperformed other fluids such as water, CO 2 , and CO 2 /water in generating large fractures with less fluid consumed. The objective of this work is to investigate the effect of initial water saturation on the performance of StimuFrac by conducting hydraulic fracturing tests with ½ foot cubic rock samples held under representative EGS stress/temperature conditions and by using cyclic injection strategies (under constant injection rate). The resulting fracture hydraulic conductivities, breakdown pressures, and volumes of fluids required are compared. Methods/Procedures/Process: To simulate geothermal reservoir conditions, in all tests, the rock sample was held under triaxial confinement and at 200 °C, and different volumes of water were initially injected into the rock sample before any fracturing processes were initiated. For the single-cycle PAA (or water) alternating CO 2 (PAG or WAG) injection fracturing experiments, one complete cycle consisted of two steps: (1) injecting a PAA slug (or water slug) followed by (2) injecting CO 2 to initiate and propagate the fracture. For experiments involving multiple injection cycles, the CO 2 injection pressure is increased until it peaks and begins to decline (indicating fracture initiation at this moment), and then continued being injected for another 30 seconds to propagate the fracture. Then, these two-step cycles [injection of PAA (or water) followed by CO 2 injection (up to 2-4 mL/min)] are repeated. Applications/Significance/Novelty: The results of this study suggest that water saturation significantly affects the fracturing fluid transmission into the rock pore space, thus affecting the fracture initiation and propagation. In this study, fracturing tests via a single injection cycle or multiple injection cycles were performed. Splitting the rock samples in half after testing reveals that fracture propagation is significantly limited under high water saturation conditions (three-day initial water injection) compared to stimulation experiments performed in hot dry rock. The fractures propagate less than 1/3 of the distance from the wellbore to the outer rock surface, and in some cases, no fracture is generated. This may be caused by leak-off dominating the fracturing process and the fluid injection rate is insufficient to overcome leak-off, even under high injection rate conditions. Additionally, CO 2 could be leaking off into the wellbore annulus and this may be making it more difficult to generate sufficiently high-pressure gradients away from the near-wellbore region. Under low water saturation conditions (dry rock or after 1-day initial water injection), PAA/CO 2 consistently generated significantly larger fractures compared with the other fluids. CO 2 generated large fractures only in the hot dry rock and only when using high injection rates, though data variability is high.

58 GEOSCIENCES↗

Normal or abnormal? Machine learning for the leakage detection in carbon sequestration projects using pressure field data

The international commitments for atmospheric carbon reduction will require a rapid increase in carbon capture and storage (CCS) projects. The key to any successful CCS project lies in the long term storage and prevention of leakage of stored carbon dioxide (CO 2 ). In addition to being a greenhouse gas, CO 2 leaks reaching the surface can accumulate in low-lying areas resulting in a serious health risk. Among several alternatives, some of the more promising CCS storage formations are depleted oil and gas reservoirs, where the reservoirs had good geological seals prior to hydrocarbon extraction. With more CCS wells coming online, it is imperative to implement permanent, automated monitoring tools. We apply machine learning models to automate the leakage detection process in carbon storage reservoirs using rates of (CO 2 ) injection and pressure data measured by simple harmonic pulse testing (HPT). To validate the feasibility of this machine learning based workflow, we use data from HPT experiments carried out in the Cranfield oil field, Mississippi, USA. The data consist of a series of pulse tests conducted with baseline parameters and with an artificially introduced leak. Here, in this study, we pose the leakage detection task as an anomaly detection problem where deviation from the predicted behavior indicates leaks in the reservoir. Results show that different machine learning architectures such as multi-layer feed forward network, Long Short-Term Memory, and convolutional neural network are able to identify leakages and can provide early warning. These warnings can then be used to take remedial measures.

58 GEOSCIENCES↗

Development of risk mitigation guidance for sensor placement inside mechanically ventilated enclosures – Phase 1

Guidance on Sensor Placement was identified as the top research priority for hydrogen sensors at the 2018 HySafe Research Priority Workshop on hydrogen safety in the category Mitigation, Sensors, Hazard Prevention, and Risk Reduction. This paper discusses the initial steps (Phase 1) to develop such guidance for mechanically ventilated enclosures. This work was initiated as an international collaborative effort to respond to emerging market needs related to the design and deployment equipment for hydrogen infrastructure that is often installed in individual equipment cabinets or ventilated enclosures. The ultimate objective of this effort is to develop guidance for an optimal sensor placement such that, when integrated into a facility design and operation, will allow earlier detection at lower levels of incipient leaks, leading to significant hazard reduction. Reliable and consistent early warning of hydrogen leaks will allow for the risk mitigation by reducing or even eliminating the probability of escalation of small leaks into large and uncontrolled events. To address this issue, a study of a real-world mechanically ventilated enclosure containing GH2 equipment was conducted, where CFD modeling of the hydrogen dispersion (performed by AVT and UQTR, and independently by the JRC) was validated by the NREL Sensor laboratory using a Hydrogen Wide Area Monitor (HyWAM) consisting of a 10-point gas and temperature measurement analyzer. In the release test, helium was used as a hydrogen surrogate. Expansion of indoor releases to other larger facilities (including parking structures, vehicle maintenance facilities and potentially tunnels) and incorporation into QRA tools, such as HyRAM is planned for Phase 2. It is anticipated that results of this work will be used to inform national and international standards such as NFPA 2 Hydrogen Technologies Code, Canadian Hydrogen Installation Code (CHIC) and relevant ISO/TC 197 and CEN documents.

08 HYDROGEN↗

Impact of boundary layer simulation on predicting radioactive pollutant dispersion: a case study for HANARO Research Reactor using the WRF-MMIF-CALPUFF modeling system

Wind plays an important role in cases of unexpected radioactive pollutant dispersion, deciding distribution and concentration of the leaked substance. The accurate prediction of wind has been challenging in numerical weather prediction models, especially near the surface because of the complex interaction between turbulent flow and topographic effect. As such, in this study, we investigated the characteristics of atmospheric dispersion of radioactive material (i.e. 137 Cs) according to the simulated boundary layer around the HANARO research nuclear reactor in Korea using the Weather Research and Forecasting (WRF)-Mesoscale Model Interface (MMIF)-California Puff (CALPUFF) model system. We examined the impacts of orographic drag on wind field, stability calculation methods, and planetary boundary layer parameterizations on the dispersion of radioactive material under a radioactive leaking scenario. We found that inclusion of the orographic drag effect in the WRF model improved the wind prediction most significantly over the complex terrain area, leading the model system to estimate the radioactive concentration near the reactor more conservatively. We also emphasized the importance of the stability calculation method and employing the skillful boundary layer parameterization to ensure more accurate low atmospheric conditions, in order to simulate more feasible spatial distribution of the radioactive dispersion in leaking scenarios.

54 ENVIRONMENTAL SCIENCES↗

Stationary and drone-assisted methane plume localization with dispersion spectroscopy

This work presents stationary and mobile retroreflector-based remote sensing techniques for methane leak localization and quantification using chirped laser dispersion spectroscopy equipped with a custom laser transceiver capable of continuous tracking of a flying drone and coupled with inverse atmospheric gas dispersion modeling. The techniques demonstrate the ability to localize leaks as low as 0.13 g CH 4 ·s -1 , which are up to 25 times smaller than those typically observed at natural gas facilities, as well as actively track a moving retroreflector mounted on a lightweight (~250 g) drone to enable spatial plume reconstruction. This system exhibited a 2.3 ppm-m sensitivity over pathlengths of 40–150 m. Source localization to within ±7 m is demonstrated using a modified horizontal radial plume mapping technique with a stationary retroreflector grid. Meanwhile, the mobile system utilizing a drone-mounted retroreflector is able to localize a controlled release within ±1 m of its source location and estimate leak rates using inversion techniques assuming type B Gaussian plume stability class within ±30% error with respect to the actual low flow rate releases.

47 OTHER INSTRUMENTATION↗