Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “laser systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

High Precision Wavelength Monitor for Tunable Laser Systems

A solid-state apparatus for tracking the wavelength of a laser emission has a power splitter that divides the laser emission into at least three equal components. Differing phase shifts are detected and processed to track variations of the laser emission.

Mark E Froggatt↗

Broadly tunable high-power operation of an all-solid-state titanium-doped sapphire laser system

Broadly tunable and high-power operation of a Ti-doped sapphire laser is obtained with a diode-laser-pumped frequency-doubled Nd:YAG laser as the pump source. A maximum broadband (FWHM = 25 nm) output pulse energy of 720 microJ at 795 nm in a TEM00 mode is obtained for 1850 microJ of energy of 532-nm pump light. A minimum pulse duration of 7 nsec is obtained from a 40-mm-long cavity. With the use of an intracavity prism, the Ti:sapphire laser is tunable continuously over the 696-1000-nm spectral range (with three different mirror sets).

Steele, T. R.↗

Advanced Orion Optimized Laser System Analysis

Contractor shall perform a complete analysis of the potential of the solid state laser in the very long pulse mode (100 ns pulse width, 10-30 hz rep-rate) and in the very short pulse mode (100 ps pulse width 10-30 hz rep rate) concentrating on the operation of the device in the 'hot-rod' mode, where no active cooling the laser operation is attempted. Contractor's calculations shall be made of the phase aberrations which develop during the repped-pulse train, and the results shall feed into the adaptive optics analyses. The contractor shall devise solutions to work around ORION track issues. A final report shall be furnished to the MSFC COTR including all calculations and analysis of estimates of bulk phase and intensity aberration distribution in the laser output beam as a function of time during the repped-pulse train for both wave forms (high-energy/long-pulse, as well as low-energy/short-pulse). Recommendations shall be made for mitigating the aberrations by laser re-design and/or changes in operating parameters of optical pump sources and/or designs.

Source record↗

Mitigation of the harmful effects of stray-light reflections in high-energy laser systems

Reduction or elimination of negative consequences of reflected stray light from lens surfaces is achieved by propagating a laser beam through an eccentric pupil that excludes the optical axis of the system, which is rotationally symmetric. In such systems, stray light reflections eventually are focused onto the unique optical axis of the system, in either a real or virtual focal region. By using an eccentric pupil, all damage due to focusing of the stray light lies outside of the beam. These focal regions can, e.g., be physically blocked to eliminate beam paths that lead to optical damage, re-pulse beams and parasitic lasing.

Seppala, Lynn G.↗

Solid state laser systems for space application

Since the last report several things have happened to effect the research effort. In laser metrology, measurements using Michelson type interferometers with an FM modulated diode laser source have been performed. The discrete Fourier transform technique has been implemented. Problems associated with this technique as well as the overall FM scheme were identified. The accuracy of the technique is not at the level we would expect at this point. We are now investigating the effect of various types of noise on the accuracy as well as making changes to the system. One problem can be addressed by modifying the original optical layout. Our research effort was also expanded to include the assembly and testing of a diode pumped\Nd:YAG laser pumped\Ti sapphire laser for possible use in sounding rocket applications. At this stage, the diode pumped Nd:YAG laser has been assembled and made operational.

Kay, Richard B.↗

The advent of third-harmonic-generation laser systems: personal recollections

In the mid to late 1970s there was considerable debate as to which laser technology should be pursued—glass lasers (1-μm wavelength) or CO 2 lasers (10 μm). Based on target-physics considerations, theorists were advocating for shorter wavelengths. The physics understanding was confirmed by exciting results from the group at the École Polytechnique, who observed close to 100% target absorption with just a few joules of fourth-harmonic energy. These results motivated the leadership at LLE to plan similar experiments at the third harmonic, with a few more joules. This presentation covers a small time period from 1979 to 1980 during which highly efficient Third-Harmonic Generation (THG) became understood theoretically and demonstrated experimentally, leading to the worldwide adoption of THG with glass lasers for fusion research.

47 OTHER INSTRUMENTATION↗

Development of improved amorphous materials for laser systems

Crystallization calculations were performed in order to determine the possibility of forming a particular type of laser glass with the avoidance of devitrification in an outer space laboratory. It was demonstrated that under the homogenuous nucleating conditions obtainable in a zero gravity laboratory this laser glass may be easily quenched to a virtually crystal-free product. Experimental evidence is provided that use of this material as a host in a neodymium glass laser would result in more than a 10 percent increase in efficiency when compared to laser glass rods of a similar composition currently commercially available. Differential thermal analysis, thermal gradient oven, X-ray diffraction, and liquidus determination experiments were carried out to determine the basics of the crystallization behavior of the glass, and small-angle X-ray scattering and splat-cooling experiments were performed in order to provide additional evidence for the feasibility of producing this laser glass material, crystal free, in an outer space environment.

Neilson, G. F.↗

High-resolution laser system for the S 3 -Low Energy Branch

Here, in this paper we present the first high-resolution laser spectroscopy results obtained at the GISELE laser laboratory of the GANIL-SPIRAL2 facility, in preparation for the first experiments with the S 3 -Low Energy Branch. Studies of neutron-deficient radioactive isotopes of erbium and tin represent the first physics cases to be studied at S 3 . The measured isotope-shift and hyperfine structure data are presented for stable isotopes of these elements. The erbium isotopes were studied using the 4f 12 6s 2 3 H 6 → 4f 12 ( 3 H)6s6p J = 5 atomic transition (415 nm) and the tin isotopes were studied by the 5s 2 5p 2 ( 3 P 0 ) → 5s 2 5p6s( 3 P 1 ) atomic transition (286.4 nm), and are used as a benchmark of the laser setup. Additionally, the tin isotopes were studied by the 5s 2 5p6s( 3 P 1 ) → 5s 2 5p6p( 3 P 2 ) atomic transition (811.6 nm), for which new isotope-shift data was obtained and the corresponding field-shift F 812 and mass-shift M 812 factors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of air pollutants over a Los Angeles freeway with a bistatic laser system

Nitric oxide, ozone, and ethylene were monitored over roads during periods of heavy traffic by transmitting several known laser wavelengths over an atmospheric path and measuring the differential absorption of the wavelengths. Heavy afternoon traffic between four and five o'clock over a 3.75 km path produced a noticeable increase in ethylene and a decrease in ozone. The changes occurred on a short time scale and correlated with the sudden traffic density increase. The ozone decrease occurs because of the sudden presence of large quantities of nitric oxide. Although the laboratory laser equipment used is rather cumbersome, the measurements did point out the potential of the laser absorption technique for monitoring large areas from one location.-

Menzies, R. T.↗

Advanced Sine Wave Modulation of Continuous Wave Laser System for Atmospheric CO2 Differential Absorption Measurements

NASA Langley Research Center in collaboration with ITT Exelis have been experimenting with Continuous Wave (CW) laser absorption spectrometer (LAS) as a means of performing atmospheric CO2 column measurements from space to support the Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) mission.Because range resolving Intensity Modulated (IM) CW lidar techniques presented here rely on matched filter correlations, autocorrelation properties without side lobes or other artifacts are highly desirable since the autocorrelation function is critical for the measurements of lidar return powers, laser path lengths, and CO2 column amounts. In this paper modulation techniques are investigated that improve autocorrelation properties. The modulation techniques investigated in this paper include sine waves modulated by maximum length (ML) sequences in various hardware configurations. A CW lidar system using sine waves modulated by ML pseudo random noise codes is described, which uses a time shifting approach to separate channels and make multiple, simultaneous online/offline differential absorption measurements. Unlike the pure ML sequence, this technique is useful in hardware that is band pass filtered as the IM sine wave carrier shifts the main power band. Both amplitude and Phase Shift Keying (PSK) modulated IM carriers are investigated that exibit perfect autocorrelation properties down to one cycle per code bit. In addition, a method is presented to bandwidth limit the ML sequence based on a Gaussian filter implemented in terms of Jacobi theta functions that does not seriously degrade the resolution or introduce side lobes as a means of reducing aliasing and IM carrier bandwidth.

Campbell, Joel F.↗

Remote measurements of ambient air pollutants with a bistatic laser system

The ambient air pollutants ozone, nitric oxide, and ethylene have been monitored in the Pasadena area with a bistatic IR laser apparatus. These pollutants were measured with a differential absorption technique, using selected wavelengths in the 9.5-, 5.2-, and 10.5-micron regions, respectively. The transmitted laser radiation was detected using both direct and heterodyne detection techniques. In the direct detection case, cube corner retroreflectors provided the return, and the heterodyne detection responded to scattered radiation from various rough surfaces, ranging from 400 m to 1.9 km in distance from the apparatus. Significant departures from ambient background concentration levels were noticed in the region near a local freeway during periods of moderate and heavy traffic.

Menzies, R. T.↗

In-situ detection of OH in the lower stratosphere with a balloon borne high repetition rate laser system

Midday stratospheric OH density measurements have been carried out within the altitude interval of 31 to 24 km using the laser-induced fluorescence technique deployed on a balloon-borne gondola launched from Palestine, Texas on July 15, 1987. Laser output at 282 nm is produced with a pulsed, 17 kHz repetition rate, copper vapor laser pumped tunable dye laser. The OH mixing ratio ranged from 16 + or - 5 ppt at 31 km to 4 + or - 3 ppt in the 27 to 24 km region. Simultaneous ozone and water vapor measurements were also obtained with separate instruments.

Stimpfle, R. M.↗

Laser System for Precise, Unambiguous Range Measurements

The Modulation Sideband Technology for Absolute Range (MSTAR) architecture is the basis of design of a proposed laser-based heterodyne interferometer that could measure a range (distance) as great as 100 km with a precision and resolution of the order of 1 nm. Simple optical interferometers can measure changes in range with nanometer resolution, but cannot measure range itself because interference is subject to the well-known integer-multiple-of-2 -radians phase ambiguity, which amounts to a range ambiguity of the order of 1 m at typical laser wavelengths. Existing rangefinders have a resolution of the order of 10 m and are therefore unable to resolve the ambiguity. The proposed MSTAR architecture bridges the gap, enabling nanometer resolution with an ambiguity range that can be extended to arbitrarily large distances. The MSTAR architecture combines the principle of the heterodyne interferometer with the principle of extending the ambiguity range of an interferometer by using light of two wavelengths. The use of two wavelengths for this purpose is well established in optical metrology, radar, and sonar. However, unlike in traditional two-color laser interferometry, light of two wavelengths would not be generated by two lasers. Instead, multiple wavelengths would be generated as sidebands of phase modulation of the light from a single frequency- stabilized laser. The phase modulation would be effected by applying sinusoidal signals of suitable frequencies (typically tens of gigahertz) to high-speed electro-optical phase modulators. Intensity modulation can also be used

Dubovitsky, Serge↗