Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “kW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Design, construction and evaluation of a 12.2 GHz, 4.0 kW-CW high efficiency klystron amplifier

An analytical and experimental program is described, for studying design techniques for optimizing the conversion efficiency of klystron amplifiers, and to utilize these techniques in the development and fabrication of an X-band 4 kW cw klystron, for use in satellite-borne television broadcast transmitters. The design is based on a technique for increasing the RF beam current by using the second harmonic space charge forces in the bunched beam. Experimental analysis was also made of a method to enhance circuit efficiency in the klystron cavities. The design incorporates a collector which is demountable from the tube to facilitate multistage depressed collector experiments employing an axisymmetric, electrostatic collector for linear beam microwave tubes.

Vishida, J. M.↗

Design, construction and evaluation of a 12.045 GHz, 2.0 kW-cw permanent-magnet focused klystron amplifier

An analytical and experimental program to demonstrate the technical feasibility of a lightweight, high-efficiency, 1-2 kW cw, permanent magnet focused klystron operating at 12.0 GHz was described. The design is based on use of a samarium-cobalt permanent magnet for focusing of the electron beam and choice of the most optimum parameters for maximum efficiency. A filter-loaded output circuit is used for the required bandwidth. The design incorporates a collector which is demountable from the tube to facilitate multistage depressed collector experiments, permitting replacement with a NASA-designed axisymmetric, electrostatic collector for linear beam microwave tubes. A further requirement is that the focusing field between the last interaction gap and the collector decay in a prescribed manner referred to as adiabatic expansion.

Nishida, J. M.↗

Research study on multi-KW-DC distribution system

A detailed definition of the HVDC test facility and the equipment required to implement the test program are provided. The basic elements of the test facility are illustrated, and consist of: the power source, conventional and digital supervision and control equipment, power distribution harness and simulated loads. The regulated dc power supplies provide steady-state power up to 36 KW at 120 VDC. Power for simulated line faults will be obtained from two banks of 90 ampere-hour lead-acid batteries. The relative merits of conventional and multiplexed power control will be demonstrated by the Supervision and Monitor Unit (SMU) and the Automatically Controlled Electrical Systems (ACES) hardware. The distribution harness is supported by a metal duct which is bonded to all component structures and functions as the system ground plane. The load banks contain passive resistance and reactance loads, solid state power controllers and active pulse width modulated loads. The HVDC test facility is designed to simulate a power distribution system for large aerospace vehicles.

Berkery, E. A.↗

Transient analysis of unbalanced short circuits of the ERDA-NASA 100 kW wind turbine alternator

Unbalanced short-circuit faults on the alternator of the ERDA-NASA Mod-O100-kW experimental wind turbine are studied. For each case, complete solutions for armature, field, and damper-circuit currents; short-circuit torque; and open-phase voltage are derived directly by a mathematical analysis. Formulated results are tabulated. For the Mod-O wind turbine alternator, numerical calculations are given, and results are presented by graphs. Comparisons for significant points among the more important cases are summarized. For these cases the transients are found to be potentially severe. The effect of the alternator neutral-to-ground impedance is evaluated.

Hwang, H. H.↗

Early operation experience on the ERDA/NASA 100 kW wind turbine

As part of the Energy Research and Development Administration (ERDA) wind energy program, NASA Lewis Research Center is testing an experimental 100-kW wind turbine. Rotor blade and drive shaft loads and tower deflection were measured during operation of the wind turbine at rated rpm. The blade loads measured are higher than anticipated. Preliminary results indicate that air flow blockage by the tower structure probably caused the high rotor blade bending moments.

Glasgow, J. C.↗

A 100-kW metal wind turbine blade basic data, loads and stress analysis

A rotor loads computer program was used to define the steady state and cyclic loads acting on 60 ft long metal blades designed for the ERDA/NASA 100 kW wind turbine. Blade load and stress analysis used to support the structural design are presented. For the loading conditions examined, the metal blades are structurally adequate for use, within the normal operating range, as part of the wind turbine system.

Cherritt, A. W.↗

A 100-kW wind turbine blade dynamics analysis, weight-balance, and structural test results

The results of dynamic analyses, weight and balance tests, static stiffness tests, and structural vibration tests on the 60-foot-long metal blades for the ERDA-NASA 100-kW wind turbine are presented. The metal blades are shown to be free from structural or dynamic resonance at the wind turbine design speed. Aeroelastic instabilities are unlikely to occur within the normal operating range of the wind turbine.

Anderson, W. D.↗

Synchronization of the ERDA-NASA 100 kW wind turbine generator with large utility networks

The synchronizing of a wind turbine generator against an infinite bus under random conditions is studied for the first time. With a digital computer, complete solutions for rotor speed, generator power angle, electromagnetic torque, wind turbine torque, wind turbine blade pitch angle, and armature current are obtained and presented by graphs. Experiments have been recently performed on the ERDA-NASA 100 kW wind turbine. Experimental results matched computer study results very closely and confirmed that the synchronization can be accomplished by means of the existing speed control system and an automatic synchronizer.

Hwang, H. H.↗

Solar power satellite 50 kW VKS-7773 cw klystron evaluation

A test program for evaluating the electrical characteristics of a cw, 50 kW power output klystron at 2.45 GHz is described. The tube tested was an 8-cavity klystron, the VKS-7773 which had been in storage for seven years. Tests included preliminary testing of the tube, cold tests of microwave components, tests of the electromagnet, and first and second hot tests of the tube. During the second hot test, the tuner in the fifth cavity went down to air, preventing any further testing. Cause of failure is not known, and recommendations are to repair and modify the tube, then proceed with testing as before to meet program objectives.

Larue, A. D.↗

Experimental data and theoretical analysis of an operating 100 kW wind turbine

Experimental test data are correlated with analyses of turbine loads and complete system behavior of the ERDA-NASA 100 kW Mod-0 wind turbine generator over a broad range of steady state conditions, as well as during transient conditions. The deficit in the ambient wind field due to the upwind tower turbine support structure is found to be very significant in exciting higher harmonic loads associated with the flapping response of the blade in bending.

Linscott, B. S.↗

A 30-cm mercury ion thruster performance with a 1 kW capacitor-diode voltage multiplier beam supply

A 1 kW solar array and capacitor-diode voltage multiplier converter (S/A-CDVM) was successfully integrated with a 30 cm diameter mercury ion thruster system to provide ion beam power. Measurements were made to compare steady state and transient response performance of a conventional bridge converter with the S/A-CDVM converter used for the ion beam supply. The ability to recover from screen to accelerator arcs and promptly re-establish stable thruster performance was demonstrated. Solar array transient response to thruster arcing was measured.

Terdan, F. F.↗

Multi-KW dc distribution system technology research study

The Multi-KW DC Distribution System Technology Research Study is the third phase of the NASA/MSFC study program. The purpose of this contract was to complete the design of the integrated technology test facility, provide test planning, support test operations and evaluate test results. The subjet of this study is a continuation of this contract. The purpose of this continuation is to study and analyze high voltage system safety, to determine optimum voltage levels versus power, to identify power distribution system components which require development for higher voltage systems and finally to determine what modifications must be made to the Power Distribution System Simulator (PDSS) to demonstrate 300 Vdc distribution capability.

Dawson, S. G.↗

30-cm mercury ion thruster performance with a 1 kW capacitor-diode voltage multiplier beam supply

A 1 kW Solar Array and Capacitor-Diode Voltage Multiplier Converter (S/A-CDVM) has been successfully integrated with a 30 cm-diameter mercury ion thruster system to provide ion beam power. Measurements were made to compare steady state and transient response performance of a conventional bridge converter with the S/A-CDVM converter used for the ion beam supply. The ability to recover from screen to accelerator arcs and promptly re-establish stable thruster performance was demonstrated. Solar array transient response to thruster arcing was also measured.

Terdan, F. F.↗

The 25 kW power module - First step beyond the baseline STS

The backbone of the first reusable Space Transportation System (STS) is the Space Shuttle. The 25 kW Power Module is currently being defined by NASA as the first significant increment in capability beyond the baseline STS and is to be available for use in 1983. The Power Module is an orbit-based space system which will augment the capability of the Space Shuttle Orbiter to support Spacelab sortie missions and will provide a unique free-flying mode for a variety of payloads which require high capability, long duration, and man-tended operation. The Power Module will make it possible for the Space Shuttle Orbiter and Spacelab to remain on-orbit for periods of time significantly in excess of that provided by the baseline STS (7 days) without major penalty to the Shuttle and its payload.

Mordan, G. W.↗

Power train analysis for the DOE/NASA 100-kW wind turbine generator

Progress in explaining variations of power experienced in the on-line operation of a 100 kW experimental wind turbine-generator is reported. Data are presented that show the oscillations tend to be characteristic of a wind-driven synchronous generator because of low torsional damping in the power train, resonances of its large structure, and excitation by unsteady and nonuniform wind flow. The report includes dynamic analysis of the drive-train torsion, the generator, passive driveline damping, and active pitch control as well as correlation with experimental recordings. The analysis assumes one machine on an infinite bus with constant generator-field excitation.

Seidel, R. C.↗

The 25 kW power module evolution study. Part 1: Payload requirements and growth scenarios

Payload power level requirements and their general impact on the baseline and growth versions of the 25 kW power module during the 1983 to 1990 period are discussed. Extended duration Orbiter sortie flight, supported by a power module, with increased payload power requirements per flight, and free-flyer payload missions are included. Other payload disciplines considered, but not emphasized for the 1983 to 1986 period include astrophysics/astronomy, earth observations, solar power satellite, and life sciences. Of these, only the solar power satellite is a prime driver for the power module.

Source record↗