Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “isotopic tracers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Anthropogenic Markers in Alta Irrigation District Water Supply Wells

In July 2016, LLNL produced a report for the Kings River Watershed Coalition Authority (KRWCA) entitled “Groundwater Age and Nitrate Isotopic Composition in Alta Irrigation District Water Supply Wells” (Esser et al., 2016). That report summarized groundwater age and nitrate isotopic composition data produced by LLNL for Alta Irrigation District (AID) groundwater wells sampled by KRWCA in a pilot project to test the utility of advanced isotopic methods for constraining the timing and source of nitrate in groundwater at selected sites in the Kings River service area. One section of that report made recommendations for follow-on study. The first and strongest recommendation was to measure a wider suite of source tracers including co-contaminants such as herbicides, pesticides, pharmaceuticals, personal care products, and food constituents and additives. KRWCA followed up on this recommendation in Phase II of the pilot study by re-sampling the original set of wells and submitting the samples to a commercial laboratory for analysis of a limited range of co-contaminants (including pharmaceuticals, personal care products , and food constituents and additives, but not including herbicides or pesticides). They have asked that LLNL review and interpret these data in the context of previous LLNL analyses and to evaluate the utility of such co-contaminant analyses in providing additional constraints on the source of groundwater nitrate contamination in Alta Irrigation District water supply wells. The goal of the second phase of this pilot project is to evaluate the utility of co-contaminant occurrence for constraining nitrate source in groundwater at selected sites in the Kings River service area, with special reference to the use of such data in conjunction with advanced isotopic methods such as nitrate isotopic composition and groundwater age. Nitrate isotopic composition alone cannot distinguish nitrate derived from animal manure from nitrate derived from human septic waste. The presence or absence of agricultural chemicals (herbicides, pesticides, veterinary pharmaceuticals) or chemicals associated with people (human pharmaceuticals, artificial sweeteners) can help make this distinction. Co-contaminant analyses using multi-analyte LC-MS-MS protocols are now commercially available and reasonably priced. The feasibility and utility of the using co-contaminants for nitrate source attribution can be evaluated by 1) determining the degree to which co-contaminants occur in distinct and easily attributable groupings (e.g. agricultural chemicals vs personal care products and food additives); 2) determining the degree to which co-contaminant occurrence is consistent with nitrate isotopic composition and groundwater age (e.g. no co-contaminant occurrence in very old groundwater; co-contaminants consistent with animal manure or human septic waste occurring in groundwaters having nitrate isotopic composition also consistent with animal manure or human septic waste); and 3) determining the degree to which co-contaminants provide additional constraint on nitrate source over and beyond nitrate isotopic composition and groundwater age (e.g. distinguishing between animal manure and human septic waste).

58 GEOSCIENCES↗

Evidence of both molecular cloud and fluid chemistry in Ryugu regolith

The sulfur chemistry of (162173) Ryugu particles can be a powerful tracer of molecular cloud chemistry and small body processes, but it has not been well explored. We report identification of organosulfurs and a sulfate grain in two Ryugu particles, A0070 and A0093. The sulfate grain shows oxygen isotope ratios (δ 17 O = -11.0 ± 4.3 per mil, δ 18 O = -7.8 ± 2.3 per mil) that are akin to silicates in Ryugu but exhibit mass-independent sulfur isotopic fractionation (Δ 33 S = +5 ± 2 per mil). A methionine-like coating on the sulfate grain is isotopically anomalous (δ 15 N = +62 ± 2 per mil). Both the sulfate and organosulfurs can simultaneously form and survive during aqueous alteration within Ryugu’s parent body, under reduced conditions, low temperature, and a pH >7 in the presence of N-rich organic molecules. This work extends the heliocentric zone where anomalous sulfur, formed by selective photodissociation of H 2 S gas in the molecular cloud, is found.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gamma-ray spectra analyses of molten salts in spent nuclear fuels pyroprocessing facilities for mass measurement

To evaluate radioactive tracer dilution and gamma spectroscopy as a safeguards technique for monitoring the mass of liquid salt in molten salt systems, the gamma spectroscopy data of salt samples from the pyroprocessing facilities in Idaho National Laboratory were acquired and analyzed. The primary focus is the uncertainty analysis of the gamma radioactivity of 154 Eu isotope in the molten salts. The facilities include an electrorefiner for pyroprocessing spent oxide fuels (SOF-ER) and Mark-IV ER for processing the metallic fuels from Experimental Breeder Reactor-II (EBR-II). The relative gamma radioactivity uncertainty was consistently at 3% for 137 Cs for both Mark-IV ER and SOF-ER salts. However, for 154 Eu, it was 8% for SOF-ER salt and 7% for Mark-IV ER salt. Here, the main reason for the higher uncertainty for 154 Eu is believed to be the lower counting statistics in gamma spectroscopy. To improve the gamma radioactivity uncertainty of isotope 154 Eu, a longer data acquisition time (12 h instead of 4 h) and a higher count rate gamma detector for gamma spectroscopy were tested and it was found that the uncertainty for 154 Eu was significantly improved from 7% or 8–3%.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Column separation of tetravalent cerium fission products from trivalent rare earth radio-isotopes

Rapid and efficient isolation of individual rare earth element (REE) radioisotopes from complex mixtures is necessary to support the fields of nuclear forensics, medical isotope production and nuclear physics measurements. The separations must be robust and generate sufficiently high purity samples for subsequent radiological analysis. Current methodologies utilize a laborious two step Ce(IV)-iodate precipitation followed by Ce(IV)-nitrate di-(2-ethylhexyl)phosphoric acid/n-heptane extraction. This work reports an alternative method to isolate Ce fission product isotopes equilibrated with milligrams of cold carrier, from the remaining REE’s using a Ce(IV)/LN-resin (Eichrom Technologies) based separation. Optimization of Ce(IV) loading, REE(III) elution volume and subsequent Ce(III) stripping step utilized 166m Ho tracer. Mixed fission product experiments provided a further test of this LN-resin method, with analysis of purified 141/144 Ce, 147 Nd and 91 Y. Overall, while decontamination factors were lower for the LN-resin method, (vs. the combined precipitation/extraction) the simplicity of the technique and the satisfactory fission product analysis results point to the efficacy of this method.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Recovery of Neptunium-236g from Photon and Proton-Irradiated Actinide Targets

Neptunium-236g is a rare radionuclide used as a tracer for neptunium-237 analyses. The availability of 236gNp is limited and the viable production routes are costly, time consuming, and only produce trace quantities of the desired product. For this work, two known production methods were tested to determine product recovery, purity, and viability for use as a tracer. The first method utilizes a photon-irradiated 237Np target to produce 236gNp by the 237Np(?,n)?236Np reaction. The second method utilizes the 238U(d,4n) ?236Np reaction. These production routes were evaluated previously, and the former was considered ineffective without isotope separation and the latter was not well-characterized for the 236mNp/236gNp production ratio. Recent resurgence of electromagnetic isotope separation technology has enabled at least partial recovery of 236gNp from part-per-million abundance feeds produced by the photonuclear reaction. To address the lack of production data for the second method, a deuteron-irradiated depleted uranium target was chemically processed to recover and purify the Np for abundance and ratio analyses. The status and current analytical results for each production method are presented.

07 ISOTOPE AND RADIATION SOURCES↗

Separation of Lipoproteins for Quantitative Analysis of 14 C-Labeled Lipid-Soluble Compounds by Accelerator Mass Spectrometry

To date, 14 C tracer studies using accelerator mass spectrometry (AMS) have not yet resolved lipid-soluble analytes into individual lipoprotein density subclasses. The objective of this work was to develop a reliable method for lipoprotein separation and quantitative recovery for biokinetic modeling purposes. The novel method developed provides the means for use of small volumes (10–200 µL) of frozen plasma as a starting material for continuous isopycnic lipoprotein separation within a carbon- and pH-stable analyte matrix, which, following post-separation fraction clean up, created samples suitable for highly accurate 14 C/ 12 C isotope ratio determinations by AMS. Manual aspiration achieved 99.2 ± 0.41% recovery of [5- 14 CH 3 ]-(2R, 4'R, 8'R)-α-tocopherol contained within 25 µL plasma recovered in triacylglycerol rich lipoproteins (TRL = Chylomicrons + VLDL), LDL, HDL, and infranatant (INF) from each of 10 different sampling times for one male and one female subject, n = 20 total samples. Small sample volumes of previously frozen plasma and high analyte recoveries make this an attractive method for AMS studies using newer, smaller footprint AMS equipment to develop genuine tracer analyses of lipophilic nutrients or compounds in all human age ranges.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Comparison of Groundwater Sampling Technologies, Including Passive Diffusion Sampling, for Radionuclide Contamination - 20205

Using traditional high-flow purge methods for long-term water quality monitoring of deep groundwater wells can be expensive, affect contaminant migration, and produce excessive volumes of discharge water that can be difficult to manage. The use of low-flow pumping methods and depth discrete bailers (DDBs) can reduce the cost of sampling deep groundwater wells. In general, using different pumping methods to obtain reproducible and representative groundwater can be challenging. Passive diffusion samplers (PDSs) have successfully been used in long-term monitoring for volatile organic compounds, major ions, and trace-elements, but application has been limited for stable and radioactive isotopes. Beginning in 2018, the United States Geological Survey (USGS) conducted three sampling events to test the ability of PDSs and DDBs to obtain reproducible and representative groundwater samples. The sampled well is completed in a regional, permeable carbonate aquifer and is one in a set of wells that have historically been used for tritium tracer testing. All samples were obtained at 180 m (590 ft) below land surface (bls) in a 13.97 cm (5.5 inch) uncased well that has a total depth of 202 m (662 ft) bls. The first sampling event deployed a regenerated cellulose dialysis membrane (RCDM) PDS for 14 days with deionized water as the blank. The second sampling event deployed a RCDM for 27 days also with deionized water as the blank. The third sampling event deployed a Dual Membrane (DM) PDS for 65 days using a blank of tritium-dead carbonate water. The DM PDS was used to assess the effect of longer term deployment on tritium concentrations and address whether or not the PDSs reached equilibrium with ambient groundwater. The day after each of the three passive samplers were retrieved a DDB was used to obtain discrete non-integrated groundwater samples. For each DDB sampling day, the bailer was lowered into the well 10 consecutive times to determine if the water chemistry changed from the first to the last bailed sample. Quality assurance samples including blanks and duplicates were obtained during all three sampling events. All blank waters had tritium concentrations less than 21±33 pCi/L. Major ion (e.g. calcium, chloride, sodium, and sulfate) results were compared between all samples obtained with RCDM and DDB. Major ion concentrations showed a coefficient of variation of less than 6% between all RCDM and DDB samples; however, the coefficient of variation between the different deployment times and the two different methods for trace-element concentrations was much larger, particularly for manganese (82%), lead (41%), and zinc (33%). Stable isotope values were compared between the RCDM and DDB samples. The DDB sample results all fell within analytical uncertainty and were considered representative of the formation groundwater. The stable isotope values from the RCDM samples indicated that a longer deployment time was necessary to gain equilibrium and to obtain representative groundwater samples. Tritium results from groundwater samples obtained from the RCDM, DM, and DDB indicate that groundwaters obtained with PDSs produced tritium concentrations 2 to 3 times higher (between 1,426 and 3,060±87 pCi/L) than groundwaters obtained with a DDB (479 to 1,219±51 pCi/L). The longer the passive diffusion samplers were deployed, the higher the tritium concentration, suggesting that equilibrium with tritium was not reached within a 27-day deployment. DDB samples showed tritium results declining from the first to the last bailed sample for all three sampling events. This research suggests that tritium results from groundwater samples obtained from PDSs are more reproducible than samples obtained from DDBs. Also, PDSs likely do not accumulate isotopes of water but rather equilibrate with the ambient groundwater. On the other hand, both PDSs and DDBs were able to provide representative groundwater samples for major ions and have the potential to produce representative groundwater samples for stable isotopes of water (δD and δ{sup 18}O). Utilizing the most effective method for sampling groundwater is important for long-term groundwater monitoring. Quantifying the ability of passive diffusion groundwater samplers to obtain representative radioactive chemistry samples will help determine if these methods can be a useful alternative to pumping and purging wells for long-term monitoring. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NanoSIP: NanoSIMS Applications for Microbial Biology

High-resolution imaging with secondary ion mass spectrometry (nanoSIMS) has become a standard method in systems biology and environmental biogeochemistry and is broadly used to decipher ecophysiological traits of environmental microorganisms, metabolic processes in plant and animal tissues, and cross-kingdom symbioses. When combined with stable isotope-labeling—an approach we refer to as nanoSIP—nanoSIMS imaging offers a distinctive means to quantify net assimilation rates and stoichiometry of individual cell-sized particles in both low- and high-complexity environments. While the majority of nanoSIP studies in environmental and microbial biology have focused on nitrogen and carbon metabolism (using 15 N and 13 C tracers), multiple advances have pushed the capabilities of this approach in the past decade. The development of a high-brightness oxygen ion source has enabled high-resolution metal analyses that are easier to perform, allowing quantification of metal distribution in cells and environmental particles. New preparation methods, tools for automated data extraction from large data sets, and analytical approaches that push the limits of sensitivity and spatial resolution have allowed for more robust characterization of populations ranging from marine archaea to fungi and viruses. Further, NanoSIMS studies continue to be enhanced by correlation with orthogonal imaging and ‘omics approaches; when linked to molecular visualization methods, such as in situ hybridization and antibody labeling, these techniques enable in situ function to be linked to microbial identity and gene expression. Here we present an updated description of the primary materials, methods, and calculations used for nanoSIP, with an emphasis on recent advances in nanoSIMS applications, key methodological steps, and potential pitfalls.

07 ISOTOPE AND RADIATION SOURCES↗

13 C-Isotope-Assisted Assessment of Metabolic Quenching During Sample Collection from Suspension Cell Cultures

Metabolomics and fluxomics are core approaches to directly profile and interrogate cellular metabolism in response to various genetic or environmental perturbations. In order to accurately measure the abundance and isotope enrichment of intracellular metabolites, cell culture samples must be rapidly harvested and cold-quenched to preserve the in vivo metabolic state of the cells at the time of sample collection. When dealing with suspension cultures, this process is complicated by the need to separate the liquid culture media from cellular biomass prior to metabolite extraction. Here, we examine the efficacy of several commonly used metabolic quenching methods, using the model cyanobacterium Synechocystis sp. PCC 6803 as an example. Multiple 13 C-labeled compounds, including 13 C-bicarbonate, 13 C-glucose and 13 C-glutamine, were used as tracers during the sample collection and cold-quenching process to assess the extent of metabolic turnover after cells were harvested from culture flasks. We show that the combination of rapid filtration followed by 100% cold (–80°C) methanol quenching exhibits the highest quenching efficiency, while mixing cell samples with a partially frozen 30% methanol slurry (–24°C) followed by centrifugation is slightly less effective at quenching metabolism but enables less laborious sample processing. By contrast, rapidly mixing the cells with a saline ice slurry (~0°C) is less effective as indicated by high isotope-labeling rates after sample harvest, while mixing the cells with 60% cold methanol (–65°C) prior to centrifugation causes significant metabolite loss. Furthermore, this study demonstrates a rigorous, quantitative, and broadly applicable method for assessing the metabolic quenching efficacy of protocols used for sample collection in metabolomics and fluxomics studies.

59 BASIC BIOLOGICAL SCIENCES↗

An Automated Ultraclean Ion Exchange Separation Method for the Determinations of 232Th and 238U in Copper using Inductively Coupled Plasma Mass Spectrometry

This work presents a novel automated analytical method developed for high throughput ultrasensitive determinations of Th and U in copper using inductively coupled plasma mass spectrometry (ICP-MS). The method is based on the use of ultra clean sample preparation procedures including the use of a fully automated off-line chromatography system for the extraction and pre-concentration of the analytes prior to ICP-MS analysis. The separation system is equipped with a single reusable chromatographic column that, with the rigorously clean procedures developed herein, provided a low carryover, low background, and reproducible automated separation method. Isotope dilution methods were used for quantitation. Method Detection Limits (MDLs) of 3.7 and 9.4 fg·g-1 were obtained for the quantitation of 232Th and 238U in copper, respectively, corresponding to activities of 0.0148 and 0.116 microBq·kg-1 for 232Th and 238U, respectively. The analytical method provided high and reproducible tracer recoveries. The use of an automated system significantly reduced the extremely tedious active work time required for the chemist (by ca. 80%) relative to manually performing the separation. This method could be adapted to other critical sample matrices requiring the utmost in high throughput clean chemistry procedures for automated ultrasensitive analyses.

Arnquist, Isaac J.↗

Inorganic resins enable the increased purification efficiency of 82 Sr from rubidium targets for use in PET imaging isotope production

The 82 Sr/ 82 Rb generator system has found use in positron emission tomography (PET) imaging of myocardial perfusion. 82 Sr is produced by proton irradiation of Rb metal/RbCl salt followed by chemical separation. Inorganic ion-exchangers were synthesized by hydrothermal methods and evaluated for the purification of accelerator-produced 82Sr from a RbCl target and co-produced impurities like 75 Se, Fe, Cr, and Ni. A process consisting of removal of bulk RbCl using sodium nonatitanate (SNT), then removal of remaining tracers of Rb and Se using poorly crystalline silicotitanate (pCST) is suitable for 82 Sr separation and achieves higher purity of 82 Sr vs. commonly used organic resins.

43 PARTICLE ACCELERATORS↗

Standoff Detection of Chemical Plumes Using Swept-ECQCL Remote Detection Technology: Results from EMRTC Complex Terrain Dual Tracer Experiment

As part of the Complex Terrain Dual Tracer Experiments performed in support of the LYNM program, a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) remote detection system was deployed to measure chemical plume propagation with high temporal resolution. The swept-ECQCL remote detection technology was initially developed at PNNL, and is now under further development at Opticslah, LLC under SBIR funding from DOE (DOE SBIR Phase I Project DE-SC0019855, Remote Detection Technologies, Program Manager Chris Ramos). The swept-ECQCL technology provides a single-frequency infrared laser source which is rapidly scanned over a large wavelength range to measure the infrared absorption of gases, liquids, or solids. Analysis of the measured infrared absorption spectrum is used to detect, identify, and quantify the chemical species which are present. While most previous laser-based techniques used small wavelength tuning ranges to measure only a few isolated spectral lines of a few species, the swept-ECQCL provides the large tuning range needed to measure multiple species simultaneously, and to detect broad absorption features from large molecules or condensed phase materials. In addition, the swept-ECQCL systems have high enough spectral resolution and sensitivity to measure narrow lines of small molecules and determine isotope ratios. The remote detection system for gas plumes is based on the swept-ECQCL technology, and consists of a swept-ECQCL source, infrared detector, control electronics, and beam transmitting and alignment optics. The remote detection system directs the infrared output of the swept-ECQCL to a target retro reflector typically located at ~10-10,000 m distance. The swept-ECQCL wavelength is varied continuously over a large wavelength range (>1000 nm) at rates up to 1000 Hz. The swept ECQCL light reflected from the remote target is collected and focused onto an infrared photodetector. By measuring the detector signal continuously as the swept-ECQCL wavelength is varied, a time-series of absorption spectra are measured for the gases along the beam line of-sight. Based on analysis and fitting of the measured absorption spectra, the time-dependent chemical concentrations of species are determined. Multiple species and mixtures can be detected simultaneously, for all species with absorption features above the sensor noise floor. The sensor output is thus a continuous, high-speed record of identified chemicals along with their concentrations and isotope ratios of interest. The high-speed operation enables low-noise operation in conditions of atmospheric turbulence and allows tracking of fluctuating concentrations in transient chemical plumes as needed for reliable remote detection applications. All components operate with minimal cooling requirements and no cryogens are needed. In addition, the output infrared light is invisible with an intensity below the maximum permissible exposure (MPE) threshold of 100 mW/cm2 for these infrared wavelengths and thus eye safe. The measurement concept for plume detection using the swept-ECQCL remote detection system is as follows. The ECQCL beam is directed toward a remote retro-reflector, which reflects the beam back to the ECQCL system where it is focused onto an infrared photodetector. The line-of-sight from the ECQCL system to the retro-reflector defines the measurement path. The detected infrared signal is recorded continuously and detects the absorption of molecular species along the measurement path. Before a plume release, the system measures absorption from atmospheric constituents, which in this LWIR band consist primarily of lines from H 2 O and CO 2 , with additional weaker absorption from N 2 O, NH 3 , and O 3 possibly contributing. The system then measures any changes in absorption due to the tracer compounds when they enter the measurement path. The shape of absorption features is used to distinguish and identify the different tracer compounds, and the strength of the absorption is used to determine the path-integrated concentration – also called the column density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrating a Water Tracer Model Into WRF‐Hydro for Characterizing the Effect of Lateral Flow in Hydrologic Simulations

Abstract Most current land models approximate terrestrial hydrological processes as one‐dimensional vertical flow, neglecting lateral water movement from ridges to valleys. Such lateral flow is fundamental at catchment scales and becomes crucial for finer‐scale land models. To test the effect of incorporating lateral flow toward three‐dimensional representations of hydrological processes in the next generation land models, we integrate a water tracer model into the WRF‐Hydro framework to track water movement from precipitation to discharge and evapotranspiration. This hydrologic‐tracer integrated system allows us to identify the key mechanisms by which lateral flow affects the flow paths and transit times in WRF‐Hydro. By comparing modeling experiments with and without lateral routing in two contrasting catchments, we determine the impacts of lateral flow on the transit times of precipitation event‐water. Results show that with limited hydrologic connectivity, lateral flow extends the transit times by reducing (increasing) event‐water drainage loss (accumulation) in ridges (valleys) and allowing reinfiltration of infiltration‐excess flow, which is missing in most land models. On the contrary with high hydrologic connectivity, lateral flow can effectively accelerate the water release to streams and reduce the transit time. However, the transit times are substantially underestimated by the model compared with isotope‐derived estimates, indicating model limitations in representing flow paths and transit times. This study provides some insights on the fundamental differences in terrestrial hydrology simulated by land models with and without lateral flow representation.

54 ENVIRONMENTAL SCIENCES↗

Investigating Mountain Watershed Headwater‐To‐Groundwater Connections, Water Sources, and Storage Selection Behavior With Dynamic‐Flux Particle Tracking

Abstract Climate change will impact mountain watershed streamflow both directly—with changing precipitation amounts and variability—and indirectly—through temperature shifts altering snowpack, melt, and evapotranspiration. To understand how these complex processes will affect ecosystem functioning and water resources, we need tools to distinguish connections between water sources (rain/snowmelt), groundwater storage, and exit fluxes (streamflow/evapotranspiration), and to determine how these connections change seasonally and as climate shifts. Here, we develop novel watershed‐scale approaches to understand water source, storage, and exit flux connections using a dynamic‐flux particle tracking model (EcoSLIM) applied in California's Cosumnes Watershed, which connects the Sierra Nevada and Central Valley. This work develops new visualizations and applications to provide mechanistic understanding that underpins the interpretation of isotopic field data at watershed scales to distinguish sources, flow paths, residence times, and storage selection. In our simulations, streamflow comes primarily from snow‐derived water while evapotranspiration generally comes from rain. Most streamflow starts above 1,000 m while evapotranspiration is sourced relatively evenly across the watershed and is generally younger than streamflow. Modeled streamflow consists primarily of water sourced from precipitation in the previous 5 years but before the current water year, while ET consists primarily of water from precipitation in the current water year. ET, and to a lesser extent streamflow, are both younger than water in groundwater storage. However, snowmelt‐derived streamflow preferentially discharges older water from snow‐derived storage. Dynamic‐flux particle tracking and new approaches presented here enable novel model‐tracer comparisons in large‐scale watersheds to better understand watershed behavior in a changing climate.

54 ENVIRONMENTAL SCIENCES↗

Gas diffusion through variably-water-saturated zeolitic tuff: Implications for transport following a subsurface nuclear event

Noble gas transport through geologic media has important applications in the characterization of underground nuclear explosions (UNEs). Without accurate transport models, it is nearly impossible to distinguish between xenon signatures originating from civilian nuclear facilities and UNEs. Understanding xenon transport time through the earth is a key parameter for interpreting measured xenon isotopic ratios. One of the most challenging aspects of modeling gas transport time is accounting for the effect of variable water saturation of geological media. In this study, we utilize bench-scale laboratory experiments to characterize the diffusion of krypton, xenon, and sulfur hexafluoride (SF6) through intact zeolitic tuff under different saturations. Here, we demonstrate that the water in rock cores with low partial saturation dramatically affects xenon transport time compared to that of krypton and SF6 by blocking sites in zeolitic tuff that preferentially adsorb xenon. This leads to breakthrough trends that are strongly influenced by the degree of the rock saturation. Xenon is especially susceptible to this phenomenon, a finding that is crucial to incorporate in subsurface gas transport models used for nuclear event identification. We also find that the breakthrough of SF6 diverges significantly from that of noble gases within our system. When developing field scale models, it is important to understand how the behavior of xenon deviates from chemical tracers used in the field, such as SF6 (Carrigan et al., 1996). These new insights demonstrate the critical need to consider the interplay between rock saturation and fission product sorption during transport modeling, and the importance of evaluating specific interactions between geomedia and gases of interest, which may differ from geomedia interactions with chemical tracers.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Application of GOTHIC to Groundwater Transport Analysis - 20152

Migration of pollutants and hazardous wastes, potentially containing radioactive isotopes, via groundwater transport is a concern at most waste cleanup sites. Predictive analysis can be used to evaluate mitigating actions intended to minimize impact on the environment and public exposure. GOTHIC is a multipurpose thermal hydraulics code that is used extensively in the nuclear industry for design, licensing and operation evaluations. It combines the capabilities of typical one-dimensional system codes and the essential features of Computational Fluid Dynamics (CFD) codes for three-dimensional analysis. There are other codes that are specifically developed for groundwater transport analysis and the results presented here are consistent with prior analyses. However, GOTHIC has some unique features that offer advantages for applications related to nuclear waste. Most importantly, it has been developed and maintained under a Quality Assurance program in compliance with the requirements of 10CFR50 Appendix B [2] and applicable portions of ASME NQA-1 [3] since 1995. Available GOTHIC capabilities that make the code especially useful for groundwater transport of nuclear materials include: - Tracking of any number of tracer elements for contaminants and other species of interest; - Radioactive decay and progeny of tracer elements; - Adsorption/desorption of tracer elements; - Tracking of any number of dissolved gases; - Release and absorption for dissolved gases; - Vapor phase tracking; - Non-Newtonian fluid modeling. The general porous body modeling approach makes GOTHIC well suited to groundwater transport analysis. The multi-region modeling approach used by GOTHIC simplifies model construction for regions of varying hydrologic characteristics and focuses the computational effort on regions of particular interest while simultaneously capturing the macroscopic response and any feedback effects across the larger domain. The applicability of GOTHIC to groundwater transport applications is demonstrated by comparing code results with available analytic or semi-analytic solutions for groundwater behavior. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

GLBRC Soil Yearlong Incubation 13C-SIP-Lipidomics

Data package for Lipids represent a dynamic, yet stable pool of microbially-derived soil carbon This data is published under a CC0 license. The authors encourage data reuse and request attribution by referencing the below citations for the data packages and associated manuscript. Please cite as: Rempfert KR, Bell SL, Kasanke CP, Kyle JE, Hofmockel KS. 2025. GLBRC Soil Yearlong Incubation 13C-SIP-Lipidomics. [Data Set] PNNL DataHub. doi: Rempfert KR, Bell SL, Kasanke CP, Kyle JE, Hofmockel KS. 2025. MSV000097435: GLBRC soil yearlong incubation 13C-SIP-Lipidomics [Data Set] MassIVE. doi:10.25345/C57659T3K Rempfert KR, Bell SL, Kasanke CP, Kyle JE, Hofmockel KS. 2025. Lipids represent a dynamic, yet stable pool of microbially-derived soil carbon. In Prep This data package consists of compound-specific 13C SIP-lipidomics data from a yearlong tracer incubation experiment designed to investigate microbial lipid persistence in switchgrass bioenergy crop soils. In order to explore how lipid structure may modulate the persistence of C in soil lipids, we leveraged soils from two sites (Michigan - sandy texture, Wisconsin - silty texture) operated by the U.S. Department of Energy-funded Great Lakes Bioenergy Research Center (GLBRC). These sites had comparable climates, identical management practices, but contrasting soil textures, allowing us to assess the variability of lipid accrual or degradation in soils as well as provide insight regarding the degree to which edaphic properties may regulate the retention of soil lipids. Untargeted lipidomics analyses were performed to identify 13C-labeled lipids in the soil microbiome after long-term incubation. Soils were supplemented with 100 micrograms glucose per gram dry soil (99 atom % 13C or natural abundance for paired control) and incubated; samples were collected two months and one year after glucose addition. Lipid extracts (MPLEx) were analyzed by LC-MS/MS and identified using LIQUID. Calculation of isotopic enrichment of lipids was performed by targeted approach using TarMet to quantify lipid isotopologues and IsoCorrectoR to correct for natural abundance isotopes. Contents: Data package contents reported here are the first version and contain downstream analysis files for the raw LC-MS mass spectrometry files (.mzXML) deposited at the MassIVE database repository under accession MSV000097435 (80 experimental runs; 5.85 GB) | MassIVE DOI: 10.25345/C57659T3K. Support files include the additional data download 'Read Me' file containing data descriptor information. Reported data download contents are structured for compliance with project data sharing guidelines, community standards initiatives, and sponsor stakeholder policies supporting FAIR data principles. Data processing software, analysis tools, and data workflows are listed below corresponding to the host repository long-term location. Available Data Downloads (0.3 GB): "GLBRC soil yearlong incubation 13C-SIP-Lipidomics_readme.txt" - 'Read Me' data package content file (txt) "GLBRC_DataPackage_analysis files" - Data processing files (Rmd) and saved intermediate data processing outputs (rds, csv, xlsx) "GLBRC_13C_lipidomics_dataset.xlsx" - processed data in tabular format (xlsx) Linked Software: LIQUID LC-MS Analysis Software | 10.5281/zenodo.6459462 Lipid Mini-On Software Tools | 10.5281/zenodo.1492803 pmartR Omics Statistical Software | 10.5281/zenodo.6108667 xcms (v4.3.3) TarMet (v1.1.1) IsoCorrectoR (1.24.0) Funding Acknowledgments: This research was supported by an Early Career Research Program award funded by the U.S. Department of Energy, Office of Science, Office of Biological and Environmental Research (OBER) Genomic Science program under FWP 68292, FWP 07880 and EMSL Exploratory Research Project 51095. A portion of this work was performed in the William R. Wiley Environmental Molecular Sciences Laboratory, a national scientific user facility sponsored by OBER and located at Pacific Northwest National Laboratory (PNNL). PNNL is a multi-program national laboratory operated by Battelle for the DOE under Contract DE-AC05-76RLO1830.

Rempfert, Kaitlin R [Pacific Northwest National La↗

Precision measurement of 65 Zn electron-capture decays with the KDK coincidence setup

65 Zn is a common calibration source, moreover used as a radioactive tracer in medical and biological studies. In many cases, γ-spectroscopy is a preferred method of 65 Zn standardization, which relies directly on the branching ratio of Jπ( 65 Zn) = 5/2- → Jπ( 65 Cu) = 5/2 - via electron capture (EC*). We measure the relative intensity of this branch to that proceeding directly to the ground state (EC 0 ) using a novel coincidence technique, finding I EC 0/IEC* = 0.9684 ± 0.0018. Re-evaluating the decay scheme of 65 Zn by adopting the commonly evaluated branching ratio of I β+ = 1.4271(7)% we obtain IEC* = (50.08 ± 0.06)%, and I EC 0 = (48.50 ± 0.06)%. The associated 1115 keV gamma intensity agrees with the previously reported NNDC value, and is now accessible with a factor of ~2 increase in precision. Our re-evaluation removes reliance on the deduction of this gamma intensity from numerous measurements, some of which disagree and depend directly on total activity determination. The KDK experimental technique provides a new avenue for verification or updates to the decay scheme of 65 Zn, and is applicable to other isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗