Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Investigation of International Space Station Major Constituent Analyzer Anomalous ORU 02 Performance

The Major Constituent Analyzer (MCA) is a mass spectrometer-based instrument designed to provide critical monitoring of six major atmospheric constituents; nitrogen, oxygen, hydrogen, carbon dioxide, methane, and water vapor on-board the International Space Station. It is an integral part of the Environmental Control and Life Support System (ECLSS). The MCA system is comprised of seven orbit-replaceable units (ORUs) that provide flexibility in maintaining the MCA. Of these, ORU 02, the analyzer assembly requires replacement every 1 to 2 years due to the consumption of limited life components including the ion pump and ion source filaments. Typically, ORU 02s that reach end of life are swapped out of the MCA on orbit and replaced with the on-orbit spare. The replaced ORU 02 is then returned to the OEM for refurbishment and is then return to service. Recently, 2 refurbished ORU 02s, serial numbers F0001 and F0003, failed on orbit shortly after being installed into the MCA. Both ORU 02s have been returned to ground for TT&E, and a failure investigation is underway. The failure signatures have been reproduced on the ground and an initial investigation has determined that both ORU 02 failures involve either the ion source or the ion source control electronics. This paper discusses the results of the failure investigation, the steps required to refurbish the ORU 02s, and the risk mitigation steps that are being incorporated into the refurbishment process to preclude the reoccurrence of these failures in the future

Gardner, Ben D.↗

The use of an ion-beam source to alter the surface morphology of biological implant materials

An electron bombardment, ion thruster was used as a neutralized-ion beam sputtering source to texture the surfaces of biological implant materials. Scanning electron microscopy was used to determine surface morphology changes of all materials after ion-texturing. Electron spectroscopy for chemical analysis was used to determine the effects of ion texturing on the surface chemical composition of some polymers. Liquid contact angle data were obtained for ion textured and untextured polymer samples. Results of tensile and fatigue tests of ion-textured metal alloys are presented. Preliminary data of tissue response to ion textured surfaces of some metals, polytetrafluoroethylene, alumina, and segmented polyurethane were obtained.

Weigand, A. J.↗

The use of an ion-beam source to alter the surface morphology of biological implant materials

An electron-bombardment ion-thruster was used as a neutralized-ion-beam sputtering source to texture the surfaces of biological implant materials. The materials investigated included 316 stainless steel; titanium-6% aluminum, 4% vanadium; cobalt-20% chromium, 15% tungsten; cobalt-35% nickel, 20% chromium, 10% molybdenum; polytetrafluoroethylene; polyoxymethylene; silicone and polyurethane copolymer; 32%-carbon-impregnated polyolefin; segmented polyurethane; silicone rubber; and alumina. Scanning electron microscopy was used to determine surface morphology changes of all materials after ion-texturing. Electron spectroscopy for chemical analysis was used to determine the effects of ion-texturing on the surface chemical composition of some polymers. Liquid contact angle data were obtained for ion-textured and untextured polymer samples. Results of tensile and fatigue tests of ion-textured metal alloys are presented. Preliminary data of tissue response to ion-textured surfaces of some metals, polytetrafluoroethylene, alumina, and segmented polyurethane have been obtained.

Weigand, A. J.↗

Plasma jet effects on the ionospheric plasma

Heavy ion beams were injected into the ionospheric plasma (experiments ARCS 1 and ARCS 2). In ARCS 1, operation of a 25eV argon ion source, mounted on a plasma diagnostic payload, produced an accelerated electron population; broadband electric field turbulence; large, spin synchronized electric field perturbations; and depletions of thermal ions. In ARCS 2, the ion source was deployed upward along the local magnetic field direction away from the diagnostic payload, and observed effects are contained within several meters of the ion source. However, enhanced wave levels near the LHR frequency are observed at distances up to 1 km, as are the injected ions themselves. A measurement of the dominant wavelength of the enhanced waves is consistent with an inference based upon the accelerated electron population seen in ARCS 1. This electron population is not evident during ARCS 2.

Moore, T. E.↗

Ion beam treatment of potential space materials at the NASA Lewis Research Center

Ion source systems in different configurations, have been used to generate unique morphologies for several NASA space applications. The discharge chamber of a 30 cm ion source was successfully used to texture potential space radiator materials for the purpose of obtaining values of thermal emittance greater than 0.85 at 700 and 900 K. High absorptance surfaces were obtained using ion beam seed texturing, for space radiator materials that were flown on the Long Duration Exposure Facility (LDEF) for 5.8 years in space. An ion source discharge chamber was also used to develop electrode surfaces with suppressed secondary electron emission characteristics for use in collectors in microwave amplifier traveling wave tubes. This was accomplished by sputtering textured carbon onto copper as well as texturing copper using tantalum and molybdenum as sacrificial texture inducing seeding materials. In a third configuration, a dual ion beam system was used to generate high transmittance diamondlike carbon (DLC) films.

Kussmaul, Michael↗

The impact of gas-surface reactions on mass spectrometric measurements of atomic nitrogen

The paper presents a simplified model of the ion source chemistry, explains several details of the data reduction method used in obtaining atomic-nitrogen (N) densities from OSS data, and discusses implications of gas-surface reactions for the design of future satellite-borne mass spectrometers. Because of various surface reactions, N appears in three different forms in the ion source, as N, NO, and NO2. Considering the rather small spin modulation of NO and NO2 in the semi-open ionization chamber used in the OSS instrument, it is not surprising that these reaction products have not been previously identified in closed source instruments as a measure of the presence of atomic nitrogen. Warmup and/or outgassing of the ion source are shown to drastically reduce the NO2 concentration, thereby making possible reliable measurement of ambient N densities.

Engebretson, M. J.↗

Radio frequency power load and associated method

A radio frequency power load and associated method. A radio frequency power load apparatus includes a container and a fluid having an ion source therein, the fluid being contained in the container. Two conductors are immersed in the fluid. A radio frequency transmission system includes a radio frequency transmitter, a radio frequency amplifier connected to the transmitter and a radio frequency power load apparatus connected to the amplifier. The apparatus includes a fluid having an ion source therein, and two conductors immersed in the fluid. A method of dissipating power generated by a radio frequency transmission system includes the steps of: immersing two conductors of a radio frequency power load apparatus in a fluid having an ion source therein; and connecting the apparatus to an amplifier of the transmission system.

Sims, III, William Herbert↗

Development of an apparatus for obtaining molecular beams in the energy range from 2 to 200 eV

The formation and detection of molecular beams obtained by charge exchange from a low-energy ion source is discussed. Dispersion in energy of the ion source was measured and problems concerning detection of neutral beams were studied. Various methods were used, specifically secondary electron emissivity of a metallic surface and ionization of a gas target with a low ionization voltage. The intensities of neutral beams as low as 10 eV are measured by a tubular electron multiplier and a lock-in amplifier.

Clapier, R.↗

Products of Dissociative Recombination in the Ionosphere

SRI International undertook a novel experimental measurement of the product states formed by dissociative recombination (DR) of O2(+), NO(+), and N2(+) as a function of both electron energy and reactant ion vibrational level. For these measurements we used a recently developed experimental technique for measuring dissociation product distributions that allows both the branching ratios to be accurately determined and the electronic and rovibrational state composition of the reactant ions to be specified. DR is the dominant electron loss mechanism in all regions of the ionosphere. In this process, electron attachment to the molecular ion produces an unstable neutral molecule that rapidly dissociates. For a molecular ion such as O2(+), the dissociation recombination reaction is (1) O2(+) + e yields O + O + W. The atomic products of this reaction, in this case two oxygen atoms, can be produced in a variety of excited states and with a variety of kinetic energies, as represented by W in Eq. (1). These atoms are not only active in the neutral chemistry of the ionosphere, but are also especially important because their optical emissions are often used to infer in situ concentrations of the parent molecular ion and ambient electron densities. Many laboratory measurements have been made of DR reaction rates under a wide range of electron temperatures, but very little is known about the actual distributions among the final states of the atomic products. This lack of knowledge seriously limits the validity and effectiveness of efforts to model both natural and man-made ionospheric disturbances. Bates recently identified major deficiencies in the currently accepted branching ratios for O2(+) as they relate to blue and green line emission measurements in the nocturnal F-region. During our two-year effort, we partially satisfied our ambitious goals. We constructed and operated a variable pressure, electron-impact ion source and a high pressure, hollow-cathode discharge ion source for O2(+), NO(+), and N2(+) beams. Translational spectroscopy of the products of dissociative charge transfer in Cs vapor was used to accurately assay the composition of the O2(+) and NO(+) beams and to develop a methodology for the vibrationally controlled preparation of the ground state ion beams. Attempts to assay the N2(+) beam revealed a novel two-electron process in the charge transfer reactions. A coaxial electron gun for the DR measurements was constructed following an extensive numerical design of the fields. Tests of the gun, however, found substantial perturbations of the magnetic fields by the soft iron (CMI-C) assembly containing the Langmuir probe that locates the electron beam. Hydrogen annealing of the iron failed to eliminate the field perturbations, necessitating the removal of the probe assembly. During this work on the coaxial electron gun, we discovered that predissociated high Rydberg states of O2 could be produced by subjecting the molecules to a sudden perturbation by an electromagnetic field. This technique allowed a measurement of the product branching to the atomic limits for the lowest seven vibrational levels of O2(+).

Cosby, Philip↗

International Space Station Major Constituent Analyzer On-Orbit Performance

The Major Constituent Analyzer is a mass spectrometer based system that measures the major atmospheric constituents on the International Space Station. A number of limited-life components require periodic change-out, including the ORU 02 analyzer and the ORU 08 Verification Gas Assembly. Improvements to ion pump operation and ion source tuning have improved lifetime performance of the current ORU 02 design. The most recent ORU 02 analyzer assemblies, as well as ORU 08, have operated nominally. For ORU 02, the ion source filaments and ion pump lifetime continue to be key determinants of MCA performance and logistical support. Monitoring several key parameters provides the capacity to monitor ORU health and properly anticipate end of life.

Gardner, Ben D.↗

A Lunar-Based Spacecraft Propulsion Concept - The Ion Beam Sail

We describe a concept for spacecraft propulsion by means of an energetic ion beam, with the ion source fixed at the spacecraft starting point (e.g., a lunar-based ion beam generator) and not onboard the vessel. This approach avoids the substantial mass penalty associated with the onboard ion source and power supply hardware, and vastly more energetic ion beam systems can be entertained. We estimate the ion beam parameters required for various scenarios, and consider some of the constraints limiting the concept. We find that the "ion beam sail' approach can be viable and attractive for journey distances not too great, for example within the Earth-Moon system, and could potentially provide support for journeys to the inner planets.

Brown, Ian G.↗

Theoretical Investigation of the High-Altitude Cusp Region using Observations from Interball and ISTP Spacecraft

A fundamental goal of magnetospheric physics is to understand the transport of plasma through the solar wind-magnetosphere-ionosphere system. To attain such an understanding, we must determine the sources of the plasma, the trajectories of the particles through the magnetospheric electric and magnetic fields to the point of observation, and the acceleration processes they undergo enroute. This study employed plasma distributions observed in the near-Earth plasma sheet by Interball and Geotail spacecraft together with theoretical techniques to investigate the ion sources and the transport of plasma. We used ion trajectory calculations in magnetic and electric fields from a global Magnetohydrodynamics (MHD) simulation to investigate the transport and to identify common ion sources for ions observed in the near-Earth magnetotail by the Interball and Geotail spacecraft. Our first step was to examine a number of distribution functions and identify distinct boundaries in both configuration and phase space that are indicative of different plasma sources and transport mechanisms. We examined events from October 26, 1995, November 29-30, 1996, and December 22, 1996. During the first event Interball and Geotail were separated by approximately 10 R(sub E) in z, and during the second event the spacecraft were separated by approximately 4(sub RE). Both of these events had a strong IMF By component pointing toward the dawnside. On October 26, 1995, the IMF B(sub Z) component was northward, and on November 1-9-30, 1996, the IMF B sub Z) component was near 0. During the first event, Geotail was located near the equator on the dawn flank, while Interball was for the most part in the lobe region. The distribution function from the Coral instrument on Interball showed less structure and resembled a drifting Maxwellian. The observed distribution on Geotail, on the other hand, included a great number of structures at both low and high energies. During the third event (December 22, 1996) both spacecraft were in the plasma sheet and were separated bY approximately 20 R(sub E) in the y direction. During this event the IMF was southward.

Ashour-Abdalla, Maha↗

Non-volatile, solid state bistable electrical switch

A bistable switching element is made of a material whose electrical resistance reversibly decreases in response to intercalation by positive ions. Flow of positive ions between the bistable switching element and a positive ion source is controlled by means of an electrical potential applied across a thermal switching element. The material of the thermal switching element generates heat in response to electrical current flow therethrough, which in turn causes the material to undergo a thermal phase transition from a high electrical resistance state to a low electrical resistance state as the temperature increases above a predetermined value. Application of the electrical potential in one direction renders the thermal switching element conductive to pass electron current out of the ion source. This causes positive ions to flow from the source into the bistable switching element and intercalate the same to produce a non-volatile, low resistance logic state. Application of the electrical potential in the opposite direction causes reverse current flow which de-intercalates the bistable logic switching element and produces a high resistance logic state.

Williams, Roger M.↗

Small mass spectrometer with extended measurement capabilities at high pressures

For the in situ investigation of planetary atmospheres a small Mattauch-Herzog mass spectrometer has been developed. Its high-pressure performance has been improved by incorporating differential pumping between the ion source and the analyzing fields, shortening the path-length as well as increasing the extraction field in the ion source. In addition doubly ionized and dissociated ions are used for mass analysis. These measures make possible operation up to 0.01 millibars. Results of laboratory tests related to linearity, dynamic range, and mass resolution are presented, in particular for CO2.

Von Zahn, U.↗

Negative ions in comets

Negative ion sources in comets are identified and cometary plasma effects caused by negative ions are examined. The primary negative ion sources are shown to be: (1) for the inner coma - photodissociation of HCN, electron attachment of OH, and collision with alkalis; (2) in the vicinity of the nucleus - interplanetary dust collisions with the nucleus; and (3) for both the contaminated solar wind region and sporadic discharges in the nonhomogeneous inner coma plasma - dissociative electron attachment and charge inversion during keV positive ion scattering by cometary dust. Negative ion abundance for Halley's Comet has been estimated to be 10 to the -6th - 10 to the -10th of electron densities.

Wekhof, A.↗

Segmented Ion Engine Operation and Performance

The continuing trend toward smaller and smaller planetary spacecraft to enable the use of smaller, less expensive launch vehicles has motivated an examination of new approaches to reduce the size and mass of xenon ion propulsion systems for these new spacecraft. A system is proposed which is based on the use of a single 4x15-cm segmented ion thruster operated from a single internally redundant power processing unit. An engine input power throttling range of 380 to 4640 W is projected. The design and operation over a power range of 600 to 2400 W of a laboratory model segmented ion engine equipped with carbon-carbon grids is presented. There appear to be no problems associated with interactions with multiple ion sources operating from a single set of high voltage power supplies, neutralization of multiple ion sources from a single centrally located neutralizer, or operation of flat, thin carbon-carbon grids.

ion↗