Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interferometry metrology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

The Effect of Companions on the SIM Reference Frame

The Space Interferometry Mission (SIM) is a 10-m Michelson space-based optical interferometer designed for precision astrometry (4 microarcseconds, 3 microarcseconds/year) with better accuracy than before over a narrow field of view. One of the primary objectives of the SIM instrument is to determine accurately the directions to a grid of stars, together with their proper motions and parallax, improving a priori knowledge by nearly three orders of magnitude over Hipparcos and one order of magnitude over FAME's planned accuracy (Johnston, 2000). The instrument does not measure directly the angular separation between stars, but rather it measures the projection of each star's direction vector onto the interferometer baseline vector by measuring the pathlength delay of starlight as it passes through the two arms of the interferometer. The accuracy and stability of SIM's celestial reference frame is subject to degradation over the 5-year mission from the reflex motion induced by massive companions of the objects used to construct the celestial reference frame. The authors present the results of simulations that show the sensitivity of reference frame accuracy to companions as a function of mass and period. They assume that pre-launch ground surveys will eliminate all objects with RMS radial velocity greater than 10 m/s. They further assume that the standard astrometric parameters of position, parallax, and proper motion plus acceleration terms in right ascension and declination will be allowed to absorb reflex motion.

ASTROMETRY↗

Compact instantaneous phase-shifting Sagnac interferometer for nanoscale tilt measurement

There is a large inter disciplinary need for high precision angular sensors in state-of-the-art technologies. This particularly applies to optical metrology in the field of Extreme Ultraviolet (EUV) or X-ray where the optics are commonly characterized in terms of slope errors at a nanoradian scale level. Here, in this paper, we present the in-lab development of an angular sensor based on a single reflection compact Sagnac interferometer using instantaneous phase shifting. Our automated prototype and first results show less than 15 nrad RMS repeatability, at least 200 nrad sensitivity and 280 nrad reproducibility over 100 μrad angular range.

36 MATERIALS SCIENCE↗

Quantum Enhanced Cavity QED Interferometer with Partially Delocalized Atoms in Lattices

Herein, we propose a quantum enhanced interferometric protocol for gravimetry and force sensing using cold atoms in an optical lattice supported by a standing-wave cavity. By loading the atoms in partially delocalized Wannier-Stark states, it is possible to cancel the undesirable inhomogeneities arising from the mismatch between the lattice and cavity fields and to generate spin squeezed states via a uniform one-axis twisting model. The quantum enhanced sensitivity of the states is combined with the subsequent application of a compound pulse sequence that allows us to separate atoms by several lattice sites. This, together with the capability to load small atomic clouds in the lattice at micrometric distances from a surface, make our setup ideal for sensing short-range forces. We show that for arrays of 10 4 atoms, our protocol can reduce the required averaging time by a factor of 10 compared to unentangled lattice-based interferometers after accounting for primary sources of decoherence.

74 ATOMIC AND MOLECULAR PHYSICS↗

Deep Space 3 Metrology System

A metrology subsystem on board the Deep Space 3, a separated interferometer mission, is used to determine stellar fringe delay jitter, delay rate, and intial delay.

Deep↗

Barium Fluoride as a Standard Reference Material for Infrared Refractometry

This work proposes a standard reference material (SRM) for measurements of refractive index in the infrared spectral region (1–12 μm). The purpose of this material is to enable cross-method comparison of refractive index data obtained through minimum deviation, ellipsometry, interferometry, and prism coupling techniques. This will allow vendors and metrology laboratories, regardless of which technique they employ, to certify that their measurements meet required levels of accuracy, precision, and repeatability. Drawing on foundational work by Tilton at the National Bureau of Standards, a figure of merit for candidate SRM materials is outlined, and three materials are selected for further evaluation. Ultimately, barium fluoride is proposed as the most suitable SRM for the infrared spectral region, based on its broad transmission range, chemical and mechanical stability, low temperature dependence of refractive index, and well-characterized dispersion behavior.

Andrew Howe↗

Improvements in optical metrology for high-performance variable-line-spacing x-ray gratings

Here, we discuss a project to develop a precision metrology system for variable-line-spacing x-ray gratings using interferometric microscopes. We are developing test standards and calibration techniques to measure and correct for geometrical distortion and blur, and data processing techniques to combine multiple measurements and measure line spacing with high accuracy.

Calibration methods↗

Two-step retrace error calibration removing tilt ambiguity in coherence scanning interferometry

In interferometry measurement, the retrace error often limits its high-precision metrology applications. Retrace error calibration with tilted flats can give a relation between the retrace error and the introduced tilt angles, but there is still an ambiguity between the introduced tilt angles and the tilt terms in the created retrace error. Here, we propose a novel, to the best of our knowledge, two-step calibration method to resolve this tilt ambiguity. It involves additional measurements of spherical mirror(s) with known curvature(s). The experiment shows that the curvature deviation due to the tilt ambiguity can be significantly reduced after applying the proposed method.

36 MATERIALS SCIENCE↗

Comparison of theory with the experimental characterization of the spatial frequency response of interferometers using a binary pseudo-random array sample

Experimental evaluations of the surface height response of an interference microscope using a binary pseudo-random array test sample are compared with a theory based on a Fourier optics model. Measurements of key instrument characteristics, including the illumination, imaging, and obscuring apertures of three different Mirau objectives, support the theoretical calculations. Agreement between experimental and theoretical modeling confirms the predictability of the spatial frequency response for the purpose of specification and optimization of instrument configuration for specific metrology tasks. The results also provide confidence in methods of compensating for the decrease in instrument response with spatial frequency.

Calibration↗

Observational Model for Precision Astrometry with the Space Interferometry Mission

The Space Interferometry Mission (SIM) is a space-based 10-m baseline Michelson optical interferometer operating in the visible waveband that is designed to achieve astrometric accuracy in the single digits of the microarcsecond domain. Over a narrow field of view SIM is expected to achieve a mission accuracy of 1 microarcsecond. In this mode SIM will search for planetary companions to nearby stars by detecting the astrometric "wobble" relative to a nearby reference star. In its wide-angle mode, SIM will provide 4 microarcsecond precision absolute position measurements of stars, with parallaxes to comparable accuracy, at the end of its 5-year mission. The expected proper motion accuracy is around 3 microarcsecond/year, corresponding to a transverse velocity of 10 m/ s at a distance of 1 kpc. The basic astrometric observable of the SIM instrument is the pathlength delay. This measurement is made by a combination of internal metrology measurements that determine the distance the starlight travels through the two arms of the interferometer, and a measurement of the white light stellar fringe to find the point of equal pathlength. Because this operation requires a non-negligible integration time, the interferometer baseline vector is not stationary over this time period, as its absolute length and orientation are time varying. This paper addresses how the time varying baseline can be "regularized" so that it may act as a single baseline vector for multiple stars, as required for the solution of the astrometric equations.

TILE OBSERVATIONS↗

Techniques for studying materials under extreme states of high energy density compression

The properties of materials under extreme conditions of pressure and density are of key interest to a number of fields, including planetary geophysics, materials science, and inertial confinement fusion. In geophysics, the equations of state of planetary materials, such as hydrogen and iron, under ultrahigh pressure and density provide a better understanding of their formation and interior structure [Celliers et al., “Insulator-metal transition in dense fluid deuterium,” Science 361, 677–682 (2018) and Smith et al., “Equation of state of iron under core conditions of large rocky exoplanets,” Nat. Astron. 2, 591–682 (2018)]. The processes of interest in these fields occur under conditions of high pressure (100 GPa–100 TPa), high temperature (>3000 K), and sometimes at high strain rates (>103 s−1) depending on the process. With the advent of high energy density (HED) facilities, such as the National Ignition Facility (NIF), Linear Coherent Light Source, Omega Laser Facility, and Z, these conditions are reachable and numerous experimental platforms have been developed. To measure compression under ultrahigh pressure, stepped targets are ramp-compressed and the sound velocity, measured by the velocity interferometer system for any reflector diagnostic technique, from which the stress-density of relevant materials is deduced at pulsed power [M. D. Knudson and M. P. Desjarlais, “High-precision shock wave measurements of deuterium: Evaluation of exchange-correlation functionals at the molecular-to-atomic transition,” Phys. Rev. Lett. 118, 035501 (2017)] and laser [Smith et al., “Equation of state of iron under core conditions of large rocky exoplanets,” Nat. Astron. 2, 591–682 (2018)] facilities. To measure strength under high pressure and strain rates, experimenters measure the growth of Rayleigh–Taylor instabilities using face-on radiography [Park et al., “Grain-size-independent plastic flow at ultrahigh pressures and strain rates,” Phys. Rev. Lett. 114, 065502 (2015)]. The crystal structure of materials under high compression is measured by dynamic x-ray diffraction [Rygg et al., “X-ray diffraction at the national ignition facility,” Rev. Sci. Instrum. 91, 043902 (2020) and McBride et al., “Phase transition lowering in dynamically compressed silicon,” Nat. Phys. 15, 89–94 (2019)]. Medium range material temperatures (a few thousand degrees) can be measured by extended x-ray absorption fine structure techniques, Yaakobi et al., “Extended x-ray absorption fine structure measurements of laser-shocked V and Ti and crystal phase transformation in Ti,” Phys. Rev. Lett. 92, 095504 (2004) and Ping et al., “Solid iron compressed up to 560 GPa,” Phys. Rev. Lett. 111, 065501 (2013), whereas more extreme temperatures are measured using x-ray Thomson scattering or pyrometry. This manuscript will review the scientific motivations, experimental techniques, and the regimes that can be probed for the study of materials under extreme HED conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamic and quasi-static strength of additively repaired aluminum

Additive manufacturing has the potential to repair high value components, saving significant time and resources; however, the level of reliability and performance of additive repairs is still relatively unknown. In this work, the structure–property and performance of laser wire additive manufacturing repairs in 1100 aluminum are investigated. Two types of intentional damage are inflicted on the samples and subsequently repaired with pulsed laser deposition additive manufacturing. Quasi-static (10 –3 s –1 ) and high strain-rate (10 –3 s –1 ) mechanical testing is carried out with in situ diagnostics and post-mortem imaging. The results show that while the quasi-static strength and ductility of samples with a repaired region are lower than a pristine sample, the dynamic strength under shock loading is comparable. This work highlights both the potential utility of additive manufacturing for repair purposes, the significant risk of compromised performance of additive parts under specific conditions, and the need to test at varying strain rates to fully characterize material performance.

36 MATERIALS SCIENCE↗

Laser System for Precise, Unambiguous Range Measurements

The Modulation Sideband Technology for Absolute Range (MSTAR) architecture is the basis of design of a proposed laser-based heterodyne interferometer that could measure a range (distance) as great as 100 km with a precision and resolution of the order of 1 nm. Simple optical interferometers can measure changes in range with nanometer resolution, but cannot measure range itself because interference is subject to the well-known integer-multiple-of-2 -radians phase ambiguity, which amounts to a range ambiguity of the order of 1 m at typical laser wavelengths. Existing rangefinders have a resolution of the order of 10 m and are therefore unable to resolve the ambiguity. The proposed MSTAR architecture bridges the gap, enabling nanometer resolution with an ambiguity range that can be extended to arbitrarily large distances. The MSTAR architecture combines the principle of the heterodyne interferometer with the principle of extending the ambiguity range of an interferometer by using light of two wavelengths. The use of two wavelengths for this purpose is well established in optical metrology, radar, and sonar. However, unlike in traditional two-color laser interferometry, light of two wavelengths would not be generated by two lasers. Instead, multiple wavelengths would be generated as sidebands of phase modulation of the light from a single frequency- stabilized laser. The phase modulation would be effected by applying sinusoidal signals of suitable frequencies (typically tens of gigahertz) to high-speed electro-optical phase modulators. Intensity modulation can also be used

Dubovitsky, Serge↗

Novel Wide Field-of-view Laser Retroreflector for the Space Interferometry Mission

A new type of laser retroreflector has been developed for JPL's future Space Interferometry Mission. The retroreflector consists of an assembly of prisms to form multiple hollow cornercubes. This way the limited field of view (FOV) of about 60deg of a single corner can be overcome, to comply with the geometry of an optical truss.

interferometry↗

Nano-Newton Electrostatic Force Actuators for Femto-Newton-Sensitive Measurements: System Performance Test in the LISA Pathfinder Mission

Electrostatic force actuation is a key component of the system of geodesic reference test masses (TM) for the LISA orbiting gravitational wave observatory and in particular for performance at low frequencies, below 1 mHz, where the observatory sensitivity is limited by stray force noise. The system needs to apply forces of order 10 −9 N while limiting fluctuations in the measurement band to levels approaching 10 −15 N=Hz 1/2 . We present here the LISA actuation system design, based on audio-frequency voltage carrier signals, and results of its in-flight performance test with the LISA Pathfinder test mission. In LISA, TM force actuation is used to align the otherwise free-falling TM to the spacecraft-mounted optical metrology system, without any forcing along the critical gravitational wave-sensitive interferometry axes. In LISA Pathfinder, on the other hand, the actuation was used also to stabilize the TM along the critical x axis joining the two TM, with the commanded actuation force entering directly into the mission’s main differential acceleration science observable. The mission allowed demonstration of the full compatibility of the electrostatic actuation system with the LISA observatory requirements, including dedicated measurement campaigns to amplify, isolate, and quantify the two main force noise contributions from the actuation system, from actuator gain noise and from low frequency “in band” voltage fluctuations. These campaigns have shown actuation force noise to be a relevant, but not dominant, noise source in LISA Pathfinder and have allowed performance projections for the conditions expected in the LISA mission.

M. Armanos↗

Optical path control in the MAM testbed

The Micro-Arcsecond Metrology (MAM) experiment is one of a family of ground-based testbeds that will demonstrate critical technologies for SIM, the Space Interferometry Mission.

optical interferometers optical path MAM testbed M↗

Technology for Space Optical Interferometry

Optical interferometers are expected to provide the next great leap forward in space based astronomy beyond the Hubble Space Telescope. Various systems are envisioned, ranging from large orbiting structures to lunar based facilities to separated spacecraft flying in formation. Regardless of the specific architecture, these systems will present unprecedented challenges in the measurement and control of optical surfaces, hence driving the technological state-of-the-art in the areas of laser metrology and alignment and stabilization of optomechanical systems.

interferometry↗

Extracting Zero-Gravity Surface Figure of a Mirror

The technical innovation involves refinement of the classic optical technique of averaging surface measurements made in different orientations with respect to gravity, so the effects of gravity cancel in the averaged image. Particularly for large, thin mirrors subject to substantial deformation, the further requirement is that mount forces must also cancel when averaged over measurement orientations. The zerogravity surface figure of a mirror in a hexapod mount is obtained by analyzing the summation of mount forces in the frame of the optic as surface metrology is averaged over multiple clockings. This is illustrated with measurements taken from the Space Interferometry Mission (SIM) PT-Ml mirror for both twofold and threefold clocking. The positive results of these measurements and analyses indicate that, from this perspective, a lighter mirror could be used; that is, one might place less reliance on the damping effects of the elliptic partial differential equations that describe the propagation of forces through glass. The advantage over prior art is relaxing the need for an otherwise substantial thickness of glass that might be needed to ensure accurate metrology in the absence of a detailed understanding and analysis of the mount forces. The general insights developed here are new, and provide the basic design principles on which mirror mount geometry may be chosen.

Bloemhof, Eric E.↗