Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “integrity attacks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Overview and Commentary on Applying the Coordinated Vulnerability Disclosure Process to Photovoltaic System Devices

The rapid expansion of photovoltaic (PV) systems, particularly inverters, has introduced new cybersecurity challenges that threaten both local operations as well as the broader electrical grid’s stability. PV inverters, integrated into critical energy infrastructure are potential targets for cyber attacks due to vulnerabilities in firmware, remote access systems, and communication protocols. The Coordinated Vulnerability Disclosure (CVD) process, as defined by the Cybersecurity and Infrastructure Security Agency (CISA), provides a framework for identifying, reporting, and addressing these vulnerabilities in a transparent and collaborative manner. This report outlines the CVD process as it applies to PV systems, detailing the roles of key stakeholders, such as manufacturers, grid operators, and security researchers. The report also highlights specific challenges in managing vulnerabilities for new and legacy PV systems, which includes those introduced by insecure communications and third-party supply chain components. By adhering to the CVD process, the PV industry can mitigate cybersecurity risks, ensure regulatory compliance, and maintain consumer trust, while safeguarding the operational resilience of the energy grid. Ultimately, the effective coordination of vulnerability management is crucial for securing the future of PV systems within the critical electric grid infrastructure landscape.

14 SOLAR ENERGY↗

A Next-Generation Countermeasure Architecture to Prevent Explosives Attacks at Large Public Events

A concept has been developed for a next-generation integrated countermeasure architecture to detect improvised explosive devices hidden on people or left behind in unstructured crowds. The work is part of the Standoff Technology Integration and Demonstration Program of the U.S. Department of Homeland Security’s Science and Technology Directorate. The architecture is based on results from an initial design tested in crowd conditions and a broad survey of existing and emerging technologies. The architecture uses a layered-defense approach that automates screening operations and prioritizes threats and mobilizes resources accordingly. A system tracks people as they move, integrating sensors to optimize threat identification accuracy and screening resources. A threat-based decision module prioritizes screening targets based on user-defined rules. Operators manage system-wide risk and mobilize field teams for interdiction. DHS is working with industry on technology development and testing to achieve the required level of system integration and economics in crowd conditions.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Resilience Measurement Framework For Post-deployment Artificial Intelligence (ai) Integrated Systems

Resilience is largely defined as the ability to adapt or recover from adverse conditions, stresses, attacks, or compromises on systems that use or are enabled by digital resources. In Artificial Intelligence Management and Research for Advanced Networked Testbed Hub (AMARANTH), resilience is measured in the amount of time it took from the beginning of a testing period for the model to reach predictions outside of the original 95% confidence interval or using the Kullback-Leibler (KL) divergence theorem, the Population Stability Index (PSI), and traditional methods such as root mean squared error (RMSE) threshold. Artificial Intelligence (AI) model drift is of significant concern when deploying AI-integrated systems into critical and/or secure environments. Drift can impact resilience of the AI-integrated system post-deployment and requires consistent maintenance and upkeep to ensure the model is accurate and precise. To quantify model drift and predict the point when a model's drift becomes unacceptable, we describe using Kullback-Leibler (KL) divergence, Population Stability Index (PSI) and/or confidence interval width estimations to determine the point of failure and time to failure of a model post-deployment. Through simple code functions, the KL-divergence, PSI, confidence interval, and root mean squared (RMSE) point of failures can be used to derive when a model needs to be maintained as well as the impact of adversarial action through statistical means.

Yockey, Patience [Idaho National Laboratory (INL),↗

Adaptive Cybersecurity for Distributed Energy Resources (AdCyDER): Online Reinforcement Learning with Stackelberg-Optimized Defenses — Pipeline Architecture, Evaluation Methodology, and Findings from a Synthetic-Data Evaluation

This report documents the design and evaluation of an integrated online-learning pipeline developed within the AdCyDER project for Distributed Energy Resource (DER) cybersecurity. The pipeline couples a Reinforcement Learning (RL) attack classifier — which produces an attack-type probability distribution — with a Stackelberg game-theoretic (GT) defense selector that consumes those distributions alongside SME-encoded priors over (defense, attack) effectiveness pairings and perdefense costs to choose grid-health-preserving defenses. The objective is not attack classification per se but production of distributions that drive effective defense selection through the Stackelberg layer, learned from delayed grid-health feedback rather than labeled attack data. AdCyDER as a whole is broader than the work presented here; this report covers the specific RL/GT loop integration and its evaluation. We present the integrated pipeline (SCADA telemetry with Fronius inverter physics, Suricata IDS, time-windowed aggregation, per-facility LSTM classifier, Stackelberg optimizer, OpenC2 actuators), an experimental campaign of 28 eight-hour iterations across three baseline modes, and a pipeline-ordered diagnostic protocol. The protocol identifies two distinct failure modes within the loop: paired supervised ceilings on the same features establish that the deployed online RL classifier (macro F1 ≈ 0.07) sits at least 4.7× below a same-architecture supervised LSTM (≈ 0.34) and 10–11× below a linear feature-signal ceiling (≈ 0.70–0.79 depending on per-facility isolation), localizing the dominant failure to the training procedure; and the reward signal driving online updates carries weak directional coupling with classifier correctness in the methodology-expected direction (multi-lens convergent: top-decile P(true) records produce more frequent state changes and slightly larger improvements, top-vs-bot Cohen’s 𝑑 ≈ −0.19), but at effect magnitudes too small to drive gradient-based learning at the campaign sample size. The original learning hypothesis is not supported by the data. The primary contributions are the diagnostic methodology — proposed as a transferable falsification protocol for online RL/GT defense pipelines learning from delayed environmental reward — and the open, reproducible experimental infrastructure. We outline reward reformulation as the highest-priority aspirational next step given the underpowered-but-aligned Q6 reading, with hardware-in-the-loop evaluation as the broadest scope-expansion option.

Blakely, Benjamin [Argonne National Laboratory (AN↗

Faster-than-real-time Simulation with Demonstration for Resilient DER Integration

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. The Faster-than-real-time Simulation with demonstration for Resilient DER Integration project set out to do the following: a. Flatten the voltage profile through the feeders and system for cost saving and voltage stabilization needs. b. Increase the amount of intermittent distributed energy resources (IDERs) that could be deployed on a utility feeder and provide 100% or more energy needed for the demands on that feeder, and c. based on an accurate model (Digital Twin) of the utilities system, be able to detect any abnormalities on the utilities distribution system. To manage the voltage and increase IDER penetration (a,b), Graph Trace Analysis is employed in a time-series, optimal power flow to coordinate the time-varying feedback control setpoints of a distribution feeder’s utility control devices. Under the coordinated control are a Load Tap Changing Transformer, a voltage regulator, and five switched capacitor banks. The feeder serves over 2000 customers, the feeder secondaries are modeled, and the feeder has 2.3 MW of PV generation, corresponding to a 17.4% penetration of PV generation. The feeder model has over 12,000 components, where every customer load bus and PV generator are modeled. The accuracy of the power flow solution is compared against historical meter voltage measurements, the improvement in conservation voltage reduction energy savings as a function of the coordinated control desired voltage profile is investigated, and the increase in PV penetration of the coordinated control over the existing control is presented. To achieve improved control performance while observing system operation constraints, bellwether Advanced Metering Infrastructure (AMI) voltage measurements are used to adjust the desired voltage profile used by the optimal power flow analysis. To detect and alleviate or negate attacks or failures on the distribution and transmission utility grids (c) the grid needs to be resilient and self-healing. In this project software was designed to do just that. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hard-ware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

Integrated System Model, Graph Trace Analysis, Adv↗

STAINLESS STEEL INTERACTIONS WITH SALT CONTAINING PLUTONIUM OXIDES

Salt containing plutonium oxide materials are treated, packaged and stored within nested, stainless steel containers based on requirements established in the DOE 3013 Standard. The moisture limit for the stored materials is less than 0.5 weight %. Surveillance activities which are conducted to assess the condition of the containers and assure continuing 3013 container integrity include the destructive examination of a select number of containers to determine whether corrosion attack has occurred as a result of stainless steel interactions with salt containing plutonium oxides. To date, some corrosion has been observed on the innermost containers, however, no corrosion has been noted on the outer containers and the integrity of the 3013 container systems is not expected to be compromised over a 50 year storage lifetime.

36 MATERIALS SCIENCE↗

Evaluation of Joint Cyber/Safety Risk in Nuclear Power Systems

This report presents an analysis of the Emergency Core Cooling System (ECCS) for a generic Boiling Water Reactor (BWR)-4 NPP. The Electric Power Research Institute (EPRI) developed Hazards and Consequences Analysis for Digital Systems (HAZCADS) process is applied to the ECCS and its subsystems to identify unsafe control actions (UCAs) which act as possible cyber events of concern. The analysis is performed for two design basis events: Small-break Loss of Coolant Accident (SLOCA) and general transients (TRANS), such as unintended reactor trip. In previous work, HAZCADS UCAs were combined with other cyber-attack analysis to develop a risk-informed approach; however, this was for a single system. This report explores advanced systems engineering modeling approaches to model the interactions between digital assets across multiple systems which may be targeted by cyber adversaries. The complex and interdependent design of digital systems has the potential to introduce emergent cyber properties that are generally not covered by hazard analyses nor formal nuclear Probabilistic Risk Assessment (PRA). The R&D and supporting analysis presented here explores approaches to predict and manage how interdependent system properties effect risk. To show the potential impact of a successful cyber-attack to formal PRA event tree probabilities, HAZCADS analysis was also used. HAZCADS was also used to model the automatic depressurization system (ADS) automatic actuation. This analysis extended to an integrated system analysis for common-cause failure (CCF). In this aspect, the HAZCADS analysis continued by analyzing plant design details for system connectivity in support of critical plant functions. A dependency matrix was developed to depict the integrated functionality of the interconnected systems. Areas of potential CCF are indicated. Future work could include adversary attack development to show how CCF could be caused, resulting in PRA events. Across the multiple systems that comprise the ECCS, the analysis shows that the change in such probabilities was very different between systems. This indicates that some systems have a larger potential risk impact from successful cyber-attack or digital failure, which indicates a need for these systems to have a higher priority for design and defensive measures. Furthermore, we were able to establish that a risk analysis using any arbitrary threat model establishes an ordering of components with regard to cyber-risk. This ordering can be used to influence the overall system design with an eye to lowering risk, or as a way to understand real-time risk to operational systems based on a current threat landscape. Expert knowledge of both the analysis process and the system being analyzed is required to perform a HAZCADS analysis. The need for a tiered risk analysis is demonstrated by the results of this report.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Robust Restoration From Cyber-Physical Attacks in Active Distribution Grids With Grid-Edge IBRs

The inverter-based resources (IBRs) have enabled the integration of renewable energy at the grid edge with enhanced control capabilities to support the reliable operation of power grids. Different control frameworks, such as hierarchical or distributed architecture, have been proposed with the expansion of cyber networks for real-time monitoring and control. This evolution of critical infrastructure into cyber-physical systems also brings more vulnerabilities for the broadened attack surfaces, and significantly increases the possibility of physical system failures or outages caused by cyberattacks. Among tremendous efforts in the defense-in-depth approach, it remains challenging to provide prompt detection and accurate location of attack entry points or paths. Therefore, the prevailing restoration framework may struggle to fully consider the cyber-physical interdependence, successfully isolate the compromised cyber and physical components, and safely recover the systems without the potential risks leading to secondary outages. This paper is motivated to develop a cyber-physical restoration framework for distribution grids to recover from cyber attacks by harnessing grid-edge IBRs. The framework is first built on the operational guidelines of IBRs considering the compromised cyber layer. Then, an ambiguity set is established to represent the uncertainty of attack scenarios and their possibility levels. Next, a distributionally robust optimization model is developed to provide the optimal load restoration strategy across all scenarios. The effectiveness of the proposed model is demonstrated through various use cases on the modified IEEE 13-node and 123-node test systems. Finally, simulation results demonstrate the effectiveness and advancement of developed post-attack restoration strategies.

Cybersecurity↗

The solvability of the first initial-boundary problem for parabolic and degenerate parabolic equations in domains with a conical point

The first initial-boundary problem for second-order parabolic and degenerate parabolic equations is investigated in a domain with a conical or angular point. The means of attack is already known and uses weighted classes of smooth or integrable functions. Sufficient conditions for a unique solution to exist and for coercive estimates for the solution to be obtained are formulated in terms of the angular measure of the solid angle and the exponent of the weight. It is also shown that if these conditions fail to hold, then the parabolic problem has elliptic properties, that is, it can have a nonzero kernel or can be nonsolvable, and, in the latter case, it is not even a Fredholm problem. A parabolic equation and an equation with some degeneracy or a singularity at a conical point are considered. Bibliography: 49 titles.

97 MATHEMATICS AND COMPUTING↗

HIDES: Hybrid Intrusion Detector for Energy Systems

The establishment of a resilient electric grid accompanied by a secure communications network is an ongoing battle as advanced persistent threats continue to exploit existing vulnerabilities in legacy supervisory control and data acquisition system (SCADA) infrastructure. Traditional intrusion detection systems (IDSs) lack consistent performance because of the continuously evolving attack surface of SCADA systems. These shortcomings can be overcome by integrating logical system behavior, protocol-specific knowledge, and data-based learning to develop a comprehensive IDS solution. In this paper, we present a Hybrid Intrusion Detector for Energy Systems by integrating a network-based IDS, state-of-the-art machine learning-based IDS, and model-based IDS to detect unknown and stealthy cyberattacks targeting the SCADA networks. The proposed IDS uses synchrophasor measurements and cyber logs to learn patterns of different scenarios based on spatiotemporal behaviors of power systems. As a proof of concept, we implement and validate the proposed IDS by leveraging resources available at the National Renewable Energy Laboratory's Energy Systems Integration Facility test bed. Experimental results show promising performance in detecting cyberattacks while providing realtime visualization of power system measurements and cyber logs.

machine-learning intrusion detection system↗

Increasing the resilience and security of the United States' power infrastructure

The United States' power infrastructure is aging, underfunded, and vulnerable to cyber attack. Emerging smart grid technologies may take some of the burden off of existing systems and make the grid as a whole more efficient, reliable, and secure. The Pacific Northwest National Laboratory (PNNL) is funding research into several aspects of smart grid technology and grid security, creating a software simulation tool that will allow researchers to test power infrastructure control and distribution paradigms by utilizing different smart grid technologies to determine how the grid and these technologies react under different circumstances. Understanding how these systems behave in real-world conditions will lead to new ways to make our power infrastructure more resilient and secure. Demonstrating security in embedded systems is another research area PNNL is tackling. Many of the systems controlling the U.S. critical infrastructure, such as the power grid, lack integrated security and the aging networks protecting them are becoming easier to attack.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Model Driven Deception for Defense of Operational Technology Environments

Due to the strong integration of real-world physics, OT deception platforms must operate differently than traditional IT deceptions. For instance, turning off a valve will be detected downstream by other sensors because the flow will reduce and stop. Additionally, controllers and applications leverage data from sensors to send control commands to each other. A believable deception must be integrated with the system to project the effects of events. An attack will likely attempt to control the physical process in a negative manner. To make the attacker believe they are achieving their objective, it must predict the effects of these actions, to a reasonable degree. Our approach to simulating a model to generate realistic decoy behavior is explored including description of two approaches: a physics model-based approach and a data driven approach. The performance of two machine learning techniques are investigated in their ability to learn a good enough model of the physics of the system.

97 MATHEMATICS AND COMPUTING↗

Integrating System Dynamics and Bayesian Networks with Application to Counter-IED Scenarios

The practice of choosing a single modeling paradigm for predictive analysis can limit the scope and relevance of predictions and their utility to decision-making processes. Considering multiple modeling methods simultaneously may improve this situation, but a better solution provides a framework for directly integrating different, potentially complementary modeling paradigms to enable more comprehensive modeling and predictions, and thus better-informed decisions. The primary challenges of this kind of model integration are to bridge language and conceptual gaps between modeling paradigms, and to determine whether natural and useful linkages can be made in a formal mathematical manner. To address these challenges in the context of two specific modeling paradigms, we explore mathematical and computational options for linking System Dynamics (SD) and Bayesian network (BN) models and incorporating data into the integrated models. We demonstrate that integrated SD/BN models can naturally be described as either state space equations or Dynamic Bayes Nets, which enables the use of many existing computational methods for simulation and data integration. To demonstrate, we apply our model integration approach to techno-social models of insurgent-led attacks and security force counter-measures centered on improvised explosive devices.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Emulation and detection of physical faults and cyber-attacks on building energy systems through real-time hardware-in-the-loop experiments

The increasing use of remote or mobile access, integrated wearable technologies, data exchange, and cloud-based data analytics in modern smart buildings is steering the building industry towards open communication technologies. The increased connectivity and accessibility could lead to more cyber-attacks in smart buildings. On the other hand, physical faults (e.g., HVAC -heating, ventilation, and air-conditioning faults) may have similar adverse impacts as those from the cyber-attacks on building energy systems, such as occupant discomfort, energy wastage, and equipment downtime. However, current physical behavior-based anomaly detection methods fail to differentiate between cyber-attacks and physical faults in building energy systems. Moreover, the challenge in collecting real-world threat data with ground truth has led researchers to rely on numerical models with user-defined assumptions, which may not accurately reflect real-world conditions due to the lack of in-situ experimental datasets. To address these challenges and gaps, this paper presents a flexible hardware-in-the-loop (HIL) testbed for generating cyber-attack and physical fault datasets and demonstrating threat detection algorithms in a real building automation system (BAS) environment. This testbed combines hardware (i.e., real BAS with local HVAC controllers and a physical network) with software (i.e., high-fidelity models to represent behaviors of building envelope and HVAC energy systems), enabling emulations of realistic threats. Five HIL experiments, including one baseline without any threats, two with physical faults, and two with cyber-attacks, were conducted to generate datasets containing detailed network traffic and system states. A joint classification framework, incorporating a network analyzer and a physical HVAC fault detector, was proposed to automatically detect cyber-physical abnormalities on BAS at both the network and the physical HVAC levels. The network analyzer comprises a conditional random fields (CRF) based command validator and a statistics-based detection strategy. The fault detector employs a weather and schedule-based pattern matching and feature-based principal component analysis (WPM-FPCA) method. Evaluation of the classification using four metrics from the multi-class confusion matrix revealed an average accuracy of 90.2%, recall of 89.7%, precision of 88.5% and F1-score of 89.2%. Finally, these results demonstrate that the proposed joint classification framework can effectively differentiate between specific types of cyber-attacks (e.g., device reinitialization attack, network Denial-of-Service attack) and physical faults (e.g., air handling unit operational fault, cooling coil valve stuck) in real time for improved building energy management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cybersecurity Assessment Methodology for International Safeguards

International nuclear safeguards are technical measures implemented by the International Atomic Energy Agency (IAEA) to verify the correctness and completeness of declarations made by States about their nuclear activities. The systems used to verify such activities include electronic and digital hardware and software components capable of data collection, processing, analysis, storage and transmission. Despite increasing efforts to protect digital systems against unauthorized access or attack through cybersecurity measures, these systems are not immune to cyber exploitation that could compromise their integrity or reliability. Previous versions of these systems did not include capabilities that exist today, such as BluetoothTM and GPS. The inclusion of these new capabilities, as well as new data processing and storage mechanisms, adds new attack vectors and opportunities for adversaries to exploit the devices that did not previously exist. As mentioned in the above referenced Cybersecurity for Safeguards study, cyber-domain vulnerabilities present risks to the equipment used to perform the international nuclear safeguards mission. The IAEA has produced guidance on the protection of nuclear facilities and their computer systems against cyber threats, but these documents do not specifically address the risks to safeguards or safeguards equipment. In response, the U.S. Department of Energy National Nuclear Security Administration (DOE/NNSA) Office of International Nuclear Safeguards/Safeguards Technology Development (NA-241) sponsored Sandia National Laboratories (Sandia, SNL) and the Idaho National Laboratory (Idaho, INL) to conduct a one-year study to evaluate cyber related vulnerabilities in safeguards equipment and develop recommendations for the mitigation of any identified risks.

97 MATHEMATICS AND COMPUTING↗

Blockchain-Based Man-in-the-Middle (MITM) Attack Detection for Photovoltaic Systems

Cybersecurity of photovoltaic (PV) systems entails a much larger scope than just encryption and firewall of communications. For instance, integrity of data in transit between inverters and a cloud server can be compromised by authorized third-party, devices, and internal network within security perimeter (i.e., man-in-the-middle (MITM) attack). To address this challenge, this paper proposes a blockchain-based MITM attack detection method for a PV system. A breakthrough method includes screening network data, network intrusion detection, and hash comparison of in-transit data using distributed ledgers. Furthermore, the proposed method is implemented in Internet-of-Thing (IoT) security modules as clients of a blockchain network and validated by experiments.

blockchain↗

Employing a Hardware-in-the-Loop Approach to Realize a Fully Homomorphic Controller for a Small Modular Advanced High Temperature Reactor

This paper addresses the cybersecurity challenges of advanced nuclear reactors by integrating fully homomorphic encryption (FHE) into their control systems, enabling encrypted processing of control signals without compromising functionality. Advanced nuclear reactors, including Small Modular Reactors (SMRs) and microreactors, aim to achieve autonomous and remote operations, reducing costs and enhancing competitiveness. However, these advancements expand the attack surface for cyberattacks, particularly in autonomous and remote operation scenarios. Cyberattacks can exploit vulnerabilities to manipulate physical processes, causing shutdowns, asset damage, or public harm. Such attacks begin with passive reconnaissance, where adversaries intercept communications or observe behaviors to gather information, which is then leveraged to execute cyber-physical attacks by injecting malicious commands. Nuclear power must adopt cybersecurity protection measures to secure the integrity and availability of their digital control systems. This paper demonstrates the application of FHE to secure operations by enabling encrypted processing of sensitive signals and parameters -- ensuring privacy without exposing data. FHE supports secure mathematical operations on encrypted data without requiring decryption. Using a hardware-in-the-loop (HIL) approach, this paper implements an FHE-integrated controller on a BeagleBone Black (BBB) controlling a simulation of the Small Modular Advanced High Temperature Reactor (SmAHTR). By doing so, the encrypted controller protects the integrity of critical set points and control signals during transmission and processing. Thus, FHE-integrated controllers enhance secure operations of advanced nuclear reactors while maintaining functionality.

control systems↗

Volt-Var Curve Reactive Power Control Requirements and Risks for Feeders with Distributed Roof-Top Photovoltaic Systems

The benefits and risks associated with Volt-Var Curve (VVC) control for management of voltages in electric feeders with distributed, roof-top photovoltaic (PV) can be defined using a stochastic hosting capacity analysis methodology. Although past work showed that a PV inverter’s reactive power can improve grid voltages for large PV installations, this study adds to the past research by evaluating the control method’s impact (both good and bad) when deployed throughout the feeder within small, distributed PV systems. The stochastic hosting capacity simulation effort iterated through hundreds of load and PV generation scenarios and various control types. The simulations also tested the impact of VVCs with tampered settings to understand the potential risks associated with a cyber-attack on all of the PV inverters scattered throughout a feeder. The simulation effort found that the VVC can have an insignificant role in managing the voltage when deployed in distributed roof-top PV inverters. This type of integration strategy will result in little to no harm when subjected to a successful cyber-attack that alters the VVC settings.

24 POWER TRANSMISSION AND DISTRIBUTION↗