Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “integrated electrode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

"Fuel Gage" for Electric Vehicles

Gas-emmission and time-integrated-current measurements indicate battery charge state. Tests indicate possibility of monitoring state of charge of lead/acid batteries at any stage in charging cycle by measuring charging current and either gas evolution or electrode potential. Data then processed by microcomputer. Uses include cell voltage, cell pressure, cell temperature and rate of gas recombination on catalyst.

Rowlette, J. J.↗

Capillary electrophoresis-electrochemistry microfluidic system for the determination of organic peroxides

A microfluidic analytical system for the separation and detection of organic peroxides, based on a microchip capillary electrophoresis device with an integrated amperometric detector, was developed. The new microsystem relies on the reductive detection of both organic acid peroxides and hydroperoxides at -700 mV (vs. Ag wire/AgCl). Factors influencing the separation and detection processes were examined and optimized. The integrated microsystem offers rapid measurements (within 130 s) of these organic-peroxide compounds, down to micromolar levels. A highly stable response for repetitive injections (RSD 0.35-3.12%; n = 12) reflects the negligible electrode passivation. Such a "lab-on-a-chip" device should be attractive for on-site analysis of organic peroxides, as desired for environmental screening and industrial monitoring.

NASA Discipline Life Sciences Technologies↗

Integrated photo-responsive metal oxide semiconductor circuit

An infrared photoresponsive element (RD) is monolithically integrated into a source follower circuit of a metal oxide semiconductor device by depositing a layer of a lead chalcogenide as a photoresistive element forming an ohmic bridge between two metallization strips serving as electrodes of the circuit. Voltage from the circuit varies in response to illumination of the layer by infrared radiation.

Jhabvala, Murzban D.↗

Mass Spectrometer Containing Multiple Fixed Collectors

A miniature mass spectrometer that incorporates features not typically found in prior mass spectrometers is undergoing development. This mass spectrometer is designed to simultaneously measure the relative concentrations of five gases (H2, He, N2, O2, and Ar) in air, over the relative-concentration range from 10(exp -6) to 1, during a sampling time as short as 1 second. It is intended to serve as a prototype of a product line of easy-to-use, portable, lightweight, highspeed, relatively inexpensive instruments for measuring concentrations of multiple chemical species in such diverse applications as detecting explosive or toxic chemicals in air, monitoring and controlling industrial processes, measuring concentrations of deliberately introduced isotopes in medical and biological investigations, and general environmental monitoring. The heart of this mass spectrometer is an integral combination of a circular cycloidal mass analyzer, multiple fixed ion collectors, and two mass-selective ion sources. By circular cycloidal mass analyzer is meant an analyzer that includes (1) two concentric circular cylindrical electrodes for applying a radial electric field and (2) a magnet arranged to impose a magnetic flux aligned predominantly along the cylindrical axis, so that ions, once accelerated into the annulus between the electrodes, move along circular cycloidal trajectories. As in other mass analyzers, trajectory of each ion is determined by its mass-to-charge ratio, and so ions of different species can be collected simultaneously by collectors (Faraday cups) at different locations intersected by the corresponding trajectories (see figure). Unlike in other mass analyzers, the installation of additional collectors to detect additional species does not necessitate increasing the overall size of the analyzer assembly.

Moskala, Robert↗

Status of commercial phosphoric acid fuel cell system development

A review of the current commercial phosphoric acid fuel cell system development efforts is presented. In both the electric utility and on-site integrated energy system applications, reducing cost and increasing reliability are important. The barrier to the attainment of these goals has been materials. The differences in approach among the three major participants are their technological features, including electrodes, matrices, intercell cooling, bipolar/separator plates, electrolyte management, fuel selection and system design philosophy.

Warshay, M.↗

A Novel, Free-Space Optical Interconnect Employing Vertical-Cavity Surface Emitting Laser Diodes and InGaAs Metal-Semiconductor-Metal Photodetectors for Gbit/s RF/Microwave Systems

Emerging technologies and continuing progress in vertical-cavity surface emitting laser (VCSEL) diode and metal-semiconductor-metal (MSM) photodetector research are making way for novel, high-speed forms of optical data transfer in communication systems. VCSEL diodes operating at 1550 nm have only recently become commercially available, while MSM photodetectors are pushing the limits of contact lithography with interdigitated electrode widths reaching sub micron levels. We propose a novel, free-space optical interconnect operating at about 1Gbit/s utilizing VCSEL diodes and MSM photodetectors. We report on development, progress, and current work, which are as follows: first, analysis of the divergent behavior of VCSEL diodes for coupling to MSM photodetectors with a 50 by 50 m active area and second, the normalized frequency response of the VCSEL diode as a function of the modulating frequency. Third, the calculated response of MSM photodetectors with varying electrode width and spacing on the order of 1 to 3 m as well as the fabrication and characterization of these devices. The work presented here will lead to the formation and characterization of a fully integrated 1Gbit/s free-space optical interconnect at 1550 nm and demonstrates both chip level and board level functionality for RF/microwave digital systems.

Savich, Gregory R.↗

Carbon Nanotubes as Resonators for RF Spectrum Analyzers

Electromechanical resonators of a proposed type would comprise single carbon nanotubes suspended between electrodes (see Figure 1). Depending on the nanotube length, diameter, and tension, these devices will resonate at frequencies in a range from megahertz through gigahertz. Like the carbon-nanotube resonators described in the preceding article, these devices will exhibit high quality factors (Q values), will be compatible with integration with electronic circuits, and, unlike similar devices made from silicone and silicone carbide, will have tunable resonant frequencies as high as several GHz. An efficient electromechanical transduction method for the carbon nanotube resonators is provided by the previously observed variation of carbon nanotube length with charge injection. It was found that injection of electrons or holes, respectively, lengthens or shortens carbon nanotubes, by amounts of the order of a percent at bias levels of a few volts. The charge-dependent length change also enables a simple and direct means of tuning the resonant frequency by varying the DC bias and hence the tension along the tube, much like tuning a guitar string. In its basic form, the invention is a tunable high-Q resonator based on a suspended carbon nanotube bridge with attached electrodes (see Figure 1). An applied DC bias controls the tension and thus the frequency of resonance. If one were to superimpose a radio-frequency (RF) bias on the DC bias, then the resulting rapid variation in tension or length would set the tube into vibration. If, on the other hand, the carbon nanotube were to be set into vibration by interaction between an incident RF electric field and electric charges in the nanotube, then the vibration would give rise to an RF signal output that is proportional to the RF amplitude at the resonance frequency. Because the transduction mechanism is extremely sensitive and the active volume is only a few nanometers in diameter, this device is not well suited for use as a microwave power device. Instead, this carbon nanotube mechanical resonator would be useful primarily as part of a highly precise, sensitive, frequency-selective detector. An array of such devices featuring nanotubes of different lengths (and thus different frequencies) could be made to operate as a highspeed spectrum analyzer (see Figure 2)

Hunt, Brian↗

Linear charge coupled device detector array for imaging light propagating in an integrated thin-film optical waveguide

Device design, fabrication, and operation of a linear charge coupled device (CCD) detector array integrated with a thin film optical waveguide and applications of this structure to integrated optical signal processing and fiber optical communications were discussed. A two phase, overlapping-gate CCD is connected in parallel by means of a series of gates to an array of photodiodes. The photodiode provides an electrode free surface region so that a highly efficient waveguide detector coupling technique can be implemented. A thermally-oxidized layer of SiO2 forms an effective substrate for the optical waveguide.

Chen, C. L.↗

Compact Packaging of Photonic Millimeter-Wave Receiver

A carrier structure made from a single silicon substrate is the basis of a compact, lightweight, relatively inexpensive package that holds the main optical/electronic coupling components of a photonic millimeter-wave receiver based on a lithium niobate resonator disk. The design of the package is simple and provides for precise relative placement of optical components, eliminating the need for complex, bulky positioning mechanisms like those commonly used to align optical components to optimize focus and coupling. Although a prototype of the package was fabricated as a discrete unit, the design is amenable to integration of the package into a larger photonic and/or electronic receiver system. The components (see figure) include a lithium niobate optical resonator disk of 5-mm diameter and .200- m thickness, positioned adjacent to a millimeter- wave resonator electrode. Other components include input and output coupling prisms and input and output optical fibers tipped with ball lenses for focusing and collimation, respectively. Laser light is introduced via the input optical fiber and focused into the input coupling prism. The input coupling prism is positioned near (but not in contact with) the resonator disk so that by means of evanescent-wave coupling, the input laser light in the prism gives rise to laser light propagating circumferentially in guided modes in the resonator disk. Similarly, a portion of the circumferentially propagating optical power is extracted from the disk by evanescent-wave coupling from the disk to the output coupling prism, from whence the light passes through the collimating ball lens into the output optical fiber. The lens-tipped optical fibers must be positioned at a specified focal distance from the prisms. The optical fibers and the prisms must be correctly positioned relative to the resonator disk and must be oriented to obtain the angle of incidence (55 in the prototype) required for evanescent-wave coupling of light into and out of the desired guided modes in the resonator disk. To satisfy all these requirements, precise alignment features are formed in the silicon substrate by use of a conventional wet-etching process. These features include a 5-mm-diameter, 50- m-deep cavity that holds the disk; two trapezoidal-cross-section recesses for the prisms; and two grooves that hold the optical fibers at the correct positions and angles relative to the prisms and disk. The fiber grooves contain abrupt tapers, near the prisms, that serve as hard stops for positioning the lenses at the focal distance from the prisms. There are also two grooves for prismadjusting rods. The design provides a little slack in the prism recesses for adjusting the positions of the prisms by means of these rods to optimize the optical coupling.

Nguyen, Hung↗

Biochips Containing Arrays of Carbon-Nanotube Electrodes

Biochips containing arrays of nanoelectrodes based on multiwalled carbon nanotubes (MWCNTs) are being developed as means of ultrasensitive electrochemical detection of specific deoxyribonucleic acid (DNA) and messenger ribonucleic acid (mRNA) biomarkers for purposes of medical diagnosis and bioenvironmental monitoring. In mass production, these biochips could be relatively inexpensive (hence, disposable). These biochips would be integrated with computer-controlled microfluidic and microelectronic devices in automated hand-held and bench-top instruments that could be used to perform rapid in vitro genetic analyses with simplified preparation of samples. Carbon nanotubes are attractive for use as nanoelectrodes for detection of biomolecules because of their nanoscale dimensions and their chemical properties.

Li, Jun↗

A dense plasma ultraviolet source

The intense ultraviolet emission from the NASA Hypocycloidal-Pinch (HCP) plasma is investigated. The HCP consists of three disk electrodes whose cross section has a configuration similar to the cross section of a Mather-type plasma focus. Plasma foci were produced in deuterium, helium, xenon, and krypton gases in order to compare their emission characteristics. Time-integrated spectra in the wavelength range from 200 nm to 350 nm and temporal variations of the uv emission were obtained with a uv spectrometer and a photomultiplier system. Modifications to enhance uv emission in the iodine-laser pump band (250 to 290 nm) and preliminary results produced by these modifications are presented. Finally, the advantages of the HCP as a uv over use of conventional xenon lamps with respect to power output limit, spectral range, and lifetime are discussed.

Lee, J. H.↗

Sensing strategies for toxic vapor detection

This work was motivated by the recommendations of the American Conference of Governmental Industrial Hygienists (ACGIH) that threshold limits for hydrazine, H2N-NH2 in air be lowered from 100 to 10 parts-per-billion (ppb) concentration levels. Hydrazine is one of the high-energy propellants used in large volumes in Space Shuttle, Titan, payloads, and other aerospace operations. Since analytical methods presently available for hydrazine detection and/or determination do not satisfy such low levels of detection, the ultimate goal of this research is the development and characterization of a portable and compact chemical sensor ideally capable to detect (in real time) 1 ppb of hydrazine, continuously and reversibly. The laboratory prototype developed as part of this project is comprised of: (1) a reactor part in which H2N-NH2 reacts, generating chemiluminescence emission, with tris(2,2'-bipyridine)ruthenium(III), which is immobilized on an ion-exchange polymeric materials of a perfluorinated hydrocarbon containing sulfonate groups as exchange centers (Nafion); (2) an electrochemical three-electrode cell posed at a potential at which the immobilized ruthenium complex could be reoxidized to the 3-oxidation state (as to provide reversible and continuous detection); and (3) a low power consumption photomultiplier tube to collect and quantitatively integrate the emitted photons with the help of auxiliary electronics and readout device.

Mottola, Horacio A.↗

NASA Tech Briefs, February 2005

Topics discussed include: Instrumentation for Sensitive Gas Measurements; Apparatus for Testing Flat Specimens of Thermal Insulation; Quadrupole Ion Mass Spectrometer for Masses of 2 to 50 Da; Miniature Laser Doppler Velocimeter for Measuring Wall Shear; Coherent Laser Instrument Would Measure Range and Velocity; Printed Microinductors for Flexible Substrates; Digital Receiver for Microwave Radiometry; Printed Antennas Made Reconfigurable by Use of MEMS Switches; Traffic-Light-Preemption Vehicle-Transponder Software Module; Intersection-Controller Software Module; Central-Monitor Software Module; Estimating Effects of Multipath Propagation on GPS Signals; Parallel Adaptive Mesh Refinement Library; Predicting Noise From Aircraft Turbine-Engine Combustors; Generating Animated Displays of Spacecraft Orbits; Diagnosis and Prognosis of Weapon Systems; Training Software in Artificial-Intelligence Computing Techniques; APGEN Version 5.0; Single-Command Approach and Instrument Placement by a Robot on a Target; Three-Dimensional Audio Client Library; Isogrid Membranes for Precise, Singly Curved Reflectors; Nickel-Tin Electrode Materials for Nonaqueous Li-Ion Cells; Photocatalytic Coats in Glass Drinking-Water Bottles; Fast Laser Shutters With Low Vibratory Disturbances; Series-Connected Buck Boost Regulators; Space Physics Data Facility Web Services; Split-Resonator, Integrated-Post Vibratory Microgyroscope; Blended Buffet-Load-Alleviation System for Fighter Airplane; Gifford-McMahon/Joule-Thomson Refrigerator Cools to 2.5 K; High-Temperature, High-Load-Capacity Radial Magnetic Bearing; Fabrication of Spherical Reflectors in Outer Space; Automated Rapid Prototyping of 3D Ceramic Parts; Tissue Engineering Using Transfected Growth-Factor Genes; Automation of Vapor-Diffusion Growth of Protein Crystals; Atom Skimmers and Atom Lasers Utilizing Them; Gears Based on Carbon Nanotubes; Patched Off-Axis Bending/Twisting Actuators for Thin Mirrors; and Improving Control in a Joule-Thomson Refrigerator.

Source record↗

Miniature biotelemeter gives multichannel wideband biomedical data

A miniature biotelemeter was developed for sensing and transmitting multiple channels of biomedical data over a radio link. The design of this miniature, 10-channel, wideband (5 kHz/channel), pulse amplitude modulation/ frequency modulation biotelemeter takes advantage of modern device technology (e.g., integrated circuit operational amplifiers, complementary symmetry/metal oxide semiconductor logic, and solid state switches) and hybrid packaging techniques. The telemeter is being used to monitor 10 channels of neuron firings from specific regions of the brain in rats implanted with chronic electrodes. Design, fabrication, and testing of an engineering model biotelemeter are described.

Carraway, J. B.↗

Hall Magnetohydrodynamic Power Generation and Drag Augmentation Using A Coaxial-Electrode Configuration During Hypersonic Entry

For interplanetary missions, a spacecraft must reduce its relative velocity from orbital speeds of multiple kilometers per second to zero in order to safely land on the surface of a planetary body. During this phase known as planetary reentry, the spacecraft undergoes high speed above Mach 5 up to Mach 30. This hyper-sonic flight regime imposes a strong bow shock in front of the vehicle that imparts extreme aerodynamic and thermal effects. In addition, during portions of this regime, a plasma is formed in the post-shock flow-field around the vehicle due to these high temperatures. Interaction between an applied magnetic field with this electrically conductive fluid, or magnetohydrodynamic (MHD) interaction, can be utilized to convert kinetic energy from the flow into storable electrical energy. Onboard MHD energy generation can benefit the spacecraft by increasing the power of active thermal control components and vehicle control systems during reentry. MHD interaction also exerts a Lorentz body force on the plasma flow that can be manipulated to act as an additional drag force through the vehicle body. MHD drag augmentation can benefit the spacecraft with an additional control mechanism that operates without moving parts. This can be utilized at higher altitudes and subsequently reduce convective heat transfer to the vehicle. MHD interaction with plasma flow suggests that both power generation and drag augmentation can be integrated together in one design. Modern numerical studies have only demonstrated the viability and potential of MHD energy generation and drag modulation separately for implementation into future spacecraft designs [1] [2] [3]. Steeves et. al. presented one possible generator design specifically for reentry vehicles that utilized a modular panel with two embedded electromagnets and two extruding electrodes for air plasma to flow between. Fujino et. al. presented results that indicated increased total drag with a permanent magnet embedded in the blunt body of the Orbital Reentry Experiment (OREX) trajectory. Furthermore, experimental investigations of these two MHD applications have been limited and separate due to the difficult technical nature of experimental de-sign and analysis. For MHD energy generation, there have been two designs which used a cylindrical fore-body with two embedded permanent magnets and two outward facing curved electrodes for tangency to an artificially ionized plasma that flowed along the body length [4] [5]. The first design was studied using an air microwave (MW) ionized supersonic plasma wind tunnel and the second design used radio frequency (RF) ionization of Argon, but both physically demonstrated the feasibility of MHD energy generation in reentry plasma conditions. For MHD drag modulation, one study involved a small-scale cylindrical blunt body embedded with permanent magnets immersed in plasma flow in an arcjet tunnel [6], and another utilized a spherical permanent magnet enclosed with a spherical forebody that was evaluated in a shock expansion tunnel [7]. Both experimental studies provided physical evidence of drag augmentation due to MHD interactions. Therefore, because of the multi-faceted effects of MHD along with both applications having been deemed feasible and beneficial during reentry, this indicates that a coupled power generation and drag modulation design could be achievable. The axi-symmetric nature of blunt bodies for reentry suggests that a spherical set of two ring electrodes near the nose along the body axis. Based on first principles, flow along the walls of the spherical body can then produce MHD interactions between the electrodes. As a result, two currents are generated: a Hall current that produces power and a primary inductive current that augments the drag force. The goal of this work is to provide a simulated design of a coaxial-electrode con-figuration for power generation and drag modulation for experimental testing.

E. Leong↗

3D Material Response Analysis of PICA Pyrolysis Experiments

The PICA decomposition experiments of Bessire and Minton are investigated using 3D material response analysis. The steady thermoelectric equations have been added to the CHAR code to enable analysis of the Joule-heated experiments and the DAKOTA optimization code is used to define the voltage boundary condition that yields the experimentally observed temperature response. This analysis has identified a potential spatial non-uniformity in the PICA sample temperature driven by the cooled copper electrodes and thermal radiation from the surface of the test article (Figure 1). The non-uniformity leads to a variable heating rate throughout the sample volume that has an effect on the quantitative results of the experiment. Averaging the results of integrating a kinetic reaction mechanism with the heating rates seen across the sample volume yield a shift of peak species production to lower temperatures that is more significant for higher heating rates (Figure 2) when compared to integrating the same mechanism at the reported heating rate. The analysis supporting these conclusions will be presented along with a proposed analysis procedure that permits quantitative use of the existing data. Time permitting, a status on the in-development kinetic decomposition mechanism based on this data will be presented as well.

Oliver, A. Brandon↗

Propellant sidefeed-short pulse discharge thruster studies

The technique of feeding a solid propellant into the discharge from the sides of the discharge was evaluated. The thrust/power ratio could be significantly effected by the included angle of V-shaped propellants and by the electrode length. This result implies that when results are compared at the same specific impulse it is possible to obtain higher thrust efficiencies. In particular, it was found that for a given discharge energy the thrust/power ratio correlated with propellant mass. Increasing the integral simultaneously increases both the gas dynamic and electromagnetic thrust. An analytic expression was formulated for ablated mass which comprehensively describes experimental data in terms of geometry and electrical parameters. The correlation of the product impulse x specific impulse with discharge energy was also described. It is suggested that the reliability of dry energy storage capacitors does not equal the reliability of liquid impregnated units when the comparison is made at the same joules/Kg rating.

Palumbo, D. J.↗

Low Crossover Polymer Electrolyte Membranes for Direct Methanol Fuel Cells

Direct Methanol Fuel Cells (DMFC's) using polymer electrolyte membranes are promising power sources for portable and vehicular applications. State of the art technology using Nafion(R) 117 membranes (Dupont) are limited by high methanol permeability and cost, resulting in reduced fuel cell efficiencies and impractical commercialization. Therefore, much research in the fuel cell field is focused on the preparation and testing of low crossover and cost efficient polymer electrolyte membranes. The University of Southern California in cooperation with the Jet Propulsion Laboratory is focused on development of such materials. Interpenetrating polymer networks are an effective method used to blend polymer systems without forming chemical links. They provide the ability to modify physical and chemical properties of polymers by optimizing blend compositions. We have developed a novel interpenetrating polymer network based on poly (vinyl - difluoride)/cross-linked polystyrenesulfonic acid polymer composites (PVDF PSSA). Sulfonation of polystyrene accounts for protonic conductivity while the non-polar, PVDF backbone provides structural integrity in addition to methanol rejection. Precursor materials were prepared and analyzed to characterize membrane crystallinity, stability and degree of interpenetration. USC JPL PVDF-PSSA membranes were also characterized to determine methanol permeability, protonic conductivity and sulfur distribution. Membranes were fabricated into membrane electrode assemblies (MEA) and tested for single cell performance. Tests include cell performance over a wide range of temperatures (20 C - 90 C) and cathode conditions (ambient Air/O2). Methanol crossover values are measured in situ using an in-line CO2 analyzer.

Prakash, G. K. Surya↗