Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “hyperspectral imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Characteristics of the Mars Pathfinder Landing Site from CRISM Hyperspectral Imaging

Preliminary analysis of CRISM imaging of the Mars Pathfinder landing site is consistent with previously reported results from landed imaging. At tens of meters scale, the surface is largely dust-covered. Lee portions of topographic knobs are reddest and show most evidence for ferric mineralogy. The nearby 1.5-km diameter "Big Crater" exposes olivine, which is atypical of the northern plains. Big Crater may have penetrated northern plains material to expose buried basaltic highlands.

Murchie, S.↗

LiveCheckHSI: a Hardware/Software Co-verification Tool for Hyperspectral Imaging Systems with Embedded System-on-Chip Instrument Avionics

The emergent technology of system-on-chip (SoC) devices promises lighter, smaller, cheaper, and more capable and reliable space electronic systems that could help to unveil some of the most treasured secrets in our universe. This technology is an improvement over the technology that is currently used in space applications, which lags behind state-of-the-art commercial-off-the-shelf (COTS) equipment by several generations. SoC technology integrates all computational power required by next-generation space exploration science instruments onto a single chip. This paper describes hardware/software co-verification tools for the Xilinx Zynq-based control and data handling system that have been developed at the Jet Propulsion Laboratory (JPL) for visible-infrared imaging spectrometers. The system acquires and compresses images in real-time, in addition to programming the spectrometer (frame rate, exposure time), focus step motor, and heaters and reporting telemetry.

Dolman, David↗

Hyperspectral Imager-Tracker

The Hyperspectral Imager-Tracker (HIT) is a technique for visualization and tracking of low-contrast, fast-moving objects. The HIT architecture is based on an innovative and only recently developed concept in imaging optics. This innovative architecture will give the Light Prescriptions Innovators (LPI) HIT the possibility of simultaneously collecting the spectral band images (hyperspectral cube), IR images, and to operate with high-light-gathering power and high magnification for multiple fast- moving objects. Adaptive Spectral Filtering algorithms will efficiently increase the contrast of low-contrast scenes. The most hazardous parts of a space mission are the first stage of a launch and the last 10 kilometers of the landing trajectory. In general, a close watch on spacecraft operation is required at distances up to 70 km. Tracking at such distances is usually associated with the use of radar, but its milliradian angular resolution translates to 100- m spatial resolution at 70-km distance. With sufficient power, radar can track a spacecraft as a whole object, but will not provide detail in the case of an accident, particularly for small debris in the onemeter range, which can only be achieved optically. It will be important to track the debris, which could disintegrate further into more debris, all the way to the ground. Such fragmentation could cause ballistic predictions, based on observations using high-resolution but narrow-field optics for only the first few seconds of the event, to be inaccurate. No optical imager architecture exists to satisfy NASA requirements. The HIT was developed for space vehicle tracking, in-flight inspection, and in the case of an accident, a detailed recording of the event. The system is a combination of five subsystems: (1) a roving fovea telescope with a wide 30 field of regard; (2) narrow, high-resolution fovea field optics; (3) a Coude optics system for telescope output beam stabilization; (4) a hyperspectral-mutispectral imaging assembly; and (5) image analysis software with effective adaptive spectral filtering algorithm for real-time contrast enhancement.

Agurok, Llya↗

Mission Concept, Science, and Technology of the PRIMA Astrophysics Probe

PRIMA addresses questions about the origins and growth of planets, supermassive black holes, stars, and dust. Much of the radiant energy from these formation processes is obscured and only emerges in the far infrared (IR) where PRIMA observes (24–261 um). PRIMA’s PI science program (25% of its 5-year mission) focuses on three questions and feeds a rich archival Guest Investigator program: How do exoplanets form and what are the origins of their atmospheres? How do galaxies’ black holes and stellar masses co-evolve over cosmic time? How do interstellar dust and metals build up in galaxies over time? PRIMA provides access to atomic (C, N, O, Ne) and molecular lines (HD, H2O, OH), redshifted PAH emission bands, and far-IR dust emission. PRIMA’s 1.8-m, 4.5-K telescope serves two instruments using sensitive KIDs: the Far-InfraRed Enhanced Survey Spectrometer (continuous, high-resolution spectral coverage with over an order of magnitude improvement in spectral line sensitivity and 3-5 orders of magnitude improvement in spectral survey speed) and the PRIMA Imager (hyperspectral imaging, broadband polarimetry). PRIMA opens new discovery space with 75% of the time for General Observers.

Jason Glenn↗

Hyperspectral Raman Imaging using a Spatial Heterodyne Spectrometer (SHS)

Savannah River National Laboratory, and the larger community, has limited chemical-specific imaging capabilities, which would be beneficial for remote detection of threat chemicals or use in inaccessible and harsh environments, as well as in-line process monitoring. The project objective is to develop a novel, rugged, highly sensitive spectrometer to support real-time, chemically specific imaging using hyperspectral Raman spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distribution and Spectroscopy of Green Fluorescent Protein and Acyl-CoA: Cholesterol Acytransferase in Sf21 Insect Cells

Acyl-CoA: cholesterol acyltransferase (ACAT) is thought to significantly participate in the pathway of cholesterol esterification that underlies the pathology of artherosclerosis. This enzyme is a membrane protein known to be preferentially bound within the endoplasmic reticulum of mammalian cells, from which location it esterifies cholesterol derived from low density lipoprotein. Cultures of insect cells were separately infected with baculovirus containing the gene for green fluroescent protein (GFP) and with baculovirus containing tandem genes for GFP and ACAT. These infected cultures expressed GFP and the fusion protein GCAT, respectively, with maximum expression occurring on the fourth day after infection. Extraction of GFP- and of GCAT-expressing cells with urea and detergent resulted in recovery of fluorescent protein in aqueous solution. Fluorescence spectra at neutral pH were identical for both GFP and GCAT extracts in aqueous solution, indicating unperturbed tertiary structure for the GFP moiety within GCAT. In a cholesterol esterification assay, GCAT demonstrated ACAT activity, but with less efficiency compared to native ACAT. It was hypothesized that the membrane protein ACAT would lead to differences in localization of GCAT compared to GFP within the respective expressing insect cells. The GFP marker directly and also within the fusion protein GCAT was accordingly used as the intracellular probe that was fluorescently analyzed by the new biophotonics technique of hyperspectral imaging. In that technique, fluorescence imaging was obtained from two dimensional arrays of cells, and regions of interest from within those images were then retrospectively analyzed for the emission spectra that comprises the image. Results of hyperspectral imaging of insect cells on day 4 postinfection showed that GCAT was preferentially localized to the cytoplasm of these cells compared to GFP. Furthermore, the emission spectra obtained for the localized GCAT displayed a peak blue shift from 518nm obtained in neutral aqueous solution to 505nm obtained in localized regions within the cells. This blue shift indicates change in the fluorescence coupling of the GFP moiety of GCAT. It is hypothesized that change in tertiary environment of GCAT, coincident with intracellular deposition of GCAT, follows from intracellular trafficking of GCAT leading to membrane interactions with the ACAT moiety, and/or self-assembly of GCAT, that alters the chromophore environment of the GFP moiety of GCAT. These findings introduce a new technique of biophotonic imaging to studies of intracellular protein trafficking and interactions. This technique of hyperspectral imaging could contribute to advancing the emergent field of proteomics. Because of the noninvasive nature of this technique, kinetic processes associated with intracellular protein trafficking, and interactions of proteins within cellular domains, can be considered for investigation within a single cell as well as a cell population.

Richmond, R. C.↗