Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “hot wire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

All-nickel hot-wire probe

Device operates in supersonic and hypersonic wind tunnels at temperatures of 700 to 760 C.

Lemos, F. R.↗

Hot-wire tile removal tool

Cheesecutterlike device uses electrically heated wire to slice through thermosetting embedment. Technique does not damage tile or create unwanted debris in work area.

Holt, J. W.↗

Flush-mounted hot-wire gage for skin friction and separation detection measurements

A heated-element skin-friction gage employing a very low thermal-conductivity support is described. It is shown that the effective dimension of the gage in the stream direction is only 0.06 mm, including the effects of heat conduction in the supporting material. Because of its small size, the calibration of the gage is independent of the kind of boundary-layer flow (whether laminar or turbulent) and is insensitive to pressure gradients. Construction tolerances can be maintained so that a single universal calibration can be applied. Multiple gages, sufficiently closely spaced so as to interfere with each other, are shown to provide accurate determinations of the location of the points of boundary-layer separation and reattachment.

Rubesin, M. W.↗

A hot wire radiant energy source for mapping the field of view of a radiometer

The design and performance of a calibration device that allows the measurement of a radiometer's field of view are described. The heart of the device is a heated 0.0254-mm (0.001-inch) diameter filament that provides a variable, isothermal line source of radiant energy against a cold background. By moving this discrete line source across the field of view of a radiometer, the radiometer's spatial response can be completely mapped. The use of a platinum filament provides a durable radiation source whose temperature is stable and repeatable to 10 K over the range of 600 to 1200 K. By varying the energy emitted by the filament, the field of view of radiometers with different sensitivities (or multiple channel radiometers) can be totally mapped.

Edwards, S. F.↗

Ignition of confined gaseous mixtures by hot surfaces and hot wires

Ignition times and spatial and temporal variations of temperature and concentration in gaseous mixtures confined between two infinite parallel walls or two infinite cylinders have been obtained by numerical integration of the appropriate conservation equations written in Lagrangian coordinates. Ignition times and ignition energies are presented for the case of an isothermal wall in terms of the initial mixture pressure and equivalence ratio for both one and two-step chemical reaction mechanisms. The numerical results indicate that there is a critical mixture pressure for which the ignition time is minimum. The values of this critical pressure are larger (smaller) than 1 atm for the one- (two-) step reaction mechanism. The critical pressure for the ignition time is not equal to the critical pressure for the ignition energy. The ignition time and energy decrease with the equivalence ratio within a certain range and then remain constant.

Ramos, J. I.↗

Hot-Wire Probe for Compressible Subsonic Flow

Probe measures velocity, density, and total temperature fluctuations. Three-wire probe used with each wire operating at different overheat ratio. Technique extendable into transonic and low supersonic flow regimes without difficulty except for those problems usually associated with lengthy calibration and possible wire breaking.

Stainback, P. C.↗

Turbulence measurements in a complex flowfield using a crossed hot-wire

An X-wire probe was used to measure the time-mean and fluctuating velocities and shear stress in nonswirling nonreacting confined jet flows. Data were taken from an axisymmetric confined jet with an expansion ratio of 2 and an expansion angle of 90 deg, and from the same segment with a contraction nozzle. Velocity profiles developed faster in the confined jet than in the free jet, with the former experiencing higher turbulence levels and larger time-mean velocities. The X-wire is concluded to furnish more accurate results for the turbulent shear stress than a multioriented single-wire technique.

Lilley, D. G.↗

Transverse vorticity measurements using an array of four hot-wire probes

A comprehensive description of the technique used to obtain a time series of the quasi-instantaneous transverse vorticity from a four wire array of probes is presented. The algorithmic structure which supports the technique is described in detail and demonstration data, from a large plane shear layer, are presented to provide a specific utilization of the technique. Sensitivity calculations are provided which allow one contribution to the inherent uncertainty of the technique to be evaluated.

Foss, J. F.↗

Hot-wire measurements of a single lateral jet injected into swirling crossflow

In the present experiments documenting the time-mean and turbulent flowfield of a deflected turbulent jet in a combined, swirling crossflow, attention is given to a jet-to-crossflow velocity ratio of 4 at swirler vane angles of 45 and 70 deg. The results obtained are presented in the form of r-x plots in order to aid in three-dimensional flowfield visualization. The time-mean velocity measurements were found to closely correspond to pitot-probe data obtained in identical flow conditions. The lateral jet was found to deflect the axis of the precessing vortex core.

Lilley, D. G.↗

Comparison of hot-wire measurement techniques in a Mach 3 pilot quiet tunnel

Disturbance measurements were made in the free stream of a small Mach 3 quiet tunnel using constant-current and constant-temperature anemometers (CCA and CTA). Data from the two types of instruments are compared in terms of frequency response and normalized rms levels of mass flow fluctuations. The mode-diagram analysis of the CCA data produces reliable results because the frequency response is consistent for a wide range of overheat ratios. However, the mode-diagram results for the CTA data cannot be used due to the rapidly decreasing frequency response with decreasing overheat ratio. Only the mass flow fluctuations at high overheat ratio can be obtained with the CTA system, and they can be as much as 50 percent higher than those from the CCA system. Possible reasons for these measurement differences between the two systems are considered.

Chen, F.-J.↗

A rotating hot-wire technique for spatial sampling of disturbed and manipulated duct flows

A duct flow spatial sampling technique, in which an X-wire probe is rotated about the center of a cylindrical test section at a radius equal to one-half that of the test section in order to furnish nearly instantaneous multipoint measurements of the streamwise and azimuthal components, is presently evaluated in view of the control of flow disturbances downstream of various open inlet contractions. The effectiveness of a particular contraction in controlling ingested flow disturbances was ascertained by artificially introducing disturbances upstream of the contractions; control effectiveness if found to be strongly dependent on inlet contraction, with consequences for the reduction of passing-blade frequency noise during gas turbine engine ground testing.

Wark, C. E.↗

The effects of feedback amplifier characteristics on constant temperature hot-wire anemometer systems

The 3rd-order analysis of Perry and Morrison (1971) was extended to 7th-order by Watmuff (1987) by including both the bridge-capacitance and the frequency-response characteristics of the feedback amplifier. In this paper, the bridge capacitance has been excluded from the analysis. The influence of the gain K, roll-off frequency f(A), and offset voltage E(qi) of the feedback amplifier are examined in more detail together with their interactions with the bridge inductance.

Watmuff, J. H.↗

Fluctuation diagrams for hot-wire anemometry in subsonic compressible flows

The concept of using 'fluctuation diagrams' for describing basic fluctuations in compressible flows was reported by Kovasznay in the 1950's. The application of this technique, for the most part, was restricted to supersonic flows. Recently, Zinovev and Lebiga published reports where they considered the fluctuation diagrams in subsonic compressible flows. For the above studies, the velocity and density sensitivities of the heated wires were equal. However, there are considerable data, much taken in the 1950's, which indicate that under some conditions the velocity and density sensitivities are not equal in subsonic compressible flows. Therefore, possible fluctuation diagrams are described for the cases where the velocity and density sensitivities are equal and the more general cases where they are unequal.

Stainback, P. C.↗