Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “glycolization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

The effects of fluids in the aircraft environment on a polyetherimide

Fluid absorption studies have been made for a polyetherimide thermoplastic film and a unidirectional composite of the thermoplastic with graphite fibers immersed in water. JP4 jet fuel, ethylene glycol, and hydraulic fluid. The changes in the weight, thickness, and tensile properties were measured for the film. The changes in the flexural properties of the composite were measured for specimens whose fiber orientation was transverse to their length. Only the hydraulic fluid, which caused an erosion or dissolving of the resin at the specimen surface, affected the film's properties. Both the water and the hydraulic fluid affected the flexural properties of the composite, due to capillary absorption along the fiber-resin interface.

Long, Edward R., Jr.↗

Phase partitioning in space and on earth

The influence of gravity on the efficiency and quality of the impressive separations achievable by bioparticle partitioning is investigated by demixing polymer phase systems in microgravity. The study involves the neutral polymers dextran and polyethylene glycol, which form a two-phase system in aqueous solution at low concentrations. It is found that demixing in low-gravity occurs primarily by coalescence, whereas on earth the demixing occurs because of density differences between the phases.

Van Alstine, James M.↗

Prepenetrant Etchant For Incology(R) 903 Weld Overlays

Etching solution developed for use prior to type-IVc penetrant inspection of Incology(R) 903 weld overlays. Formulated as follows: 80 g ferric chloride hexahydrate, 300 mL reagent-grade hydrochloric acid, 25 mL food- or reagent-grade phosphoric acid, and 100 mL ethylene glycol. Gives more reasonable range of etching time and reduces probability of overetching and resulting damage. Stored indefinitely.

O'Tousa, Joseph E.↗

Flow visualization techniques for flight research

In-flight flow visualization techniques used at the Dryden Flight Research Facility of NASA Ames Research Center (Ames-Dryden) and its predecessor organizations are described. Results from flight tests which visualized surface flows using flow cones, tufts, oil flows, liquid crystals, sublimating chemicals, and emitted fluids were obtained. Off-surface flow visualization of vortical flow was obtained from natural condensation and two methods using smoke generator systems. Recent results from flight tests at NASA Langley Research Center using a propylene glycol smoker and an infrared imager are also included. Results from photo-chase aircraft, onboard and postflight photography are presented.

Fisher, David F.↗

A vapor generator for transonic flow visualization

A vapor generator was developed for use in the NASA Langley Transonic Dynamics Tunnel (TDT). Propylene glycol was used as the vapor material. The vapor generator system was evaluated in a laboratory setting and then used in the TDT as part of a laser light sheet flow visualization system. The vapor generator provided satisfactory seeding of the air flow with visible condensate particles, smoke, for tests ranging from low subsonic through transonic speeds for tunnel total pressures from atmospheric pressure down to less than 0.1 atmospheric pressure.

Bruce, Robert A.↗

Human serum albumin crystals and method of preparation

Human serum albumin (HSA) crystals are provided in the form of tetragonal plates having the space groups P42(sub 1)2, the crystals being grown to sizes in excess of 0.5 mm in two dimensions and a thickness of 0.1 mm. Growth of the crystals is carried out by a hanging drop method wherein a precipitant solution containing polyethylene glycol (PEG) and a phosphate buffer is mixed with an HSA solution, and a droplet of mixed solution is suspended over a well of precipitant solution. Crystals grow to the desired size in 3 to 7 days. Concentration of reagents, pH and other parameters are controlled within prescribed limits. The resulting crystals exhibit a size and quality such as to allow performance of x ray diffraction studies and enable the conduct of drug binding studies as well as genetic engineering studies.

Carter, Daniel C.↗

Three-dimensional structure of human serum albumin

The three-dimensional structure of human serum albumin has been solved at 6.0 A resolution by the method of multiple isomorphous replacement. Crystals were grown from solutions of polyethylene glycol in the infrequently observed space group P42(1)2 and diffracted X-rays to lattice d-spacings of less than 2.9 A. The electron density maps are of high quality and revealed the structure as a predominantly alpha-helical globin protein in which the course of the polypeptide can be traced. The binding loci of several organic compounds have been determined.

Carter, Daniel C.↗

Application of partition technology to particle electrophoresis

The effects of polymer-ligand concentration on particle electrophoretic mobility and partition in aqueous polymer two-phase systems are investigated. Polymer coating chemistry and affinity ligand synthesis, purification, and analysis are conducted. It is observed that poly (ethylene glycol)-ligands are effective for controlling particle electrophoretic mobility.

Van Alstine, James M.↗

Cell separation in immunoaffinity partition in aqueous polymer two-phase systems

Two methods for immunoaffinity partitioning are described. One technique involves the covalent coupling of poly (ethylene glycol) (PEG) to immunoglobulin G antibody preparations. In the second method PEG-modified Protein A is used to complex with cells and unmodified antibody. The effects of PEG molecular weight, the degree of modification, and varying phase system composition on antibody activity and its affinity for the upper phase are studied. It is observed that both methods resulted in effective cell separation.

Karr, Laurel J.↗

Laboratory studies of polyoxymethylene - Application to comets

Formaldehyde polymer mass spectra gathered by means of the particle beam and direct insertion probe system indicate that these substances can evaporate at 300 K and yield gas-phase polyoxymethylene glycols in the presence of water. These experimental results are presently used to ascertain the likely origin of the polymeric ions that have been observed with the Giotto mission's PICCA instrument. The experimental results are held to be in keeping with the hypothesized presence of formaldehyde polymers in comets.

Moller, Gregory↗

Radial spreading of viscous-gravity currents with solidifying crust

In the present investigation of solidifying-crust effects on the dynamics and surface morphology of radial viscous-gravity currents, polyethylene glycol inflows into the base of a tank holding a cold sucrose solution are used as analogs. As the radial current advanced away from the inlet, its surface solidified and deformed through a combination of folding anf fracturing. When cooling was sufficiently rapid, solid crust formed and caused the spreading rate to increase; progressively colder experiments revealed a sequence of surface morphologies resembling features of cooling lava flows and lava lakes, including multiarmed rift structures with shear offsets and bulbous lobate forms resembling pillow lavas on the ocean floor.

Fink, Jonathan H.↗

A synchronous strobed laser light sheet for helicopter model rotor flow visualization

A synchronous, strobed laser light sheet has been developed for use in flow visualization of a helicopter rotor model. The light sheet strobe circuit included selectable blade position, strobe duration, and multiple pulses per revolution for rotors having 2 to 9 blades. The flow was seeded with propylene glycol. Between runs, a calibration grid board was placed in the plane of the laser sheet and recorded with the video camera at the position used to record the flow field. A slip-sync mode permitted slow motion visualization of the flow field over complete rotations of the rotor. The system was used to make two-dimensional flow field cuts of a four-bladed rotor operating at advance ratio of 0.37 at wind tunnel speeds up to 79.25 meters per second (260 feet per second).

Leighty, Bradley D.↗

Calorimetric output power measurements on a CW 20 kW 7.16 GHz microwave transmitter

A calorimetric measurement technique developed for NASA's Deep Space Network (DSN) transmitters that does not require data on the coolant's thermal parameters is described. Calibration of the measurement system is achieved by measuring the DC input power to the klystron and relating coolant temperature increases to this known power dissipation. Agreement between calorimetric and electrical measurements of total system power was good, the difference being less than 2 percent. The operation of the system was not greatly affected by the composition of the coolant, which was varied from pure water to 40 percent ethylene glycol by mass. Good accuracy was also shown at output power levels, which varied over a 3.6:1 range.

Perez, Raul M.↗

Gel-Filled Holders For Ultrasonic Transducers

In new technique, ultrasonic transducer embedded in rubbery, castable, low-loss gel to enable transducer to "look" into surface of test object or human body at any desired angle. Composed of solution of water and ethylene glycol in collagen matrix. Provides total contact of water bath, also used on bodies or objects too large for water baths, even if moving. Also provides look angles of poly(methyl methacrylate) angle block with potential of reduced acoustic impedance and refraction. Custom-tailored to task at hand, and gel sufficiently inexpensive to be discarded upon completion. Easy to couple ultrasound in and out of gel, minimizing losses and artifacts of other types of standoffs employed in ultrasonic testing.

Companion, John A.↗

Metallized gelled monopropellants

Thermochemical calculations of seven metallized monopropellants were conducted to quantify theoretical specific impulse and density specific impulse performance. On the basis of theoretical performance, commercial availability of formulation constituents, and anticipated viscometric behavior, two metallized monopropellants were selected for formulation characterization: triethylene glycol dinitrate, ammonium perchlorate, aluminum and hydrogen peroxide, aluminum. Formulation goals were established, and monopropellant formulation compatibility and hazard sensitivity were experimentally determined. These experimental results indicate that the friction sensitivity, detonation susceptibility, and material handling difficulties of the elevated monopropellant formulations and their constituents pose formidable barriers to their future application as metallized monopropellants.

Nieder, Erin G.↗

Metal etching composition

The present invention is directed to a chemical etching composition for etching metals or metallic alloys. The composition includes a solution of hydrochloric acid, phosphoric acid, ethylene glycol, and an oxidizing agent. The etching composition is particularly useful for etching metal surfaces in preparation for subsequent fluorescent penetrant inspection.

Otousa, Joseph E.↗

Controlled method of reducing electrophoretic mobility of macromolecules, particles, or cells

A method of reducing electrophoretic mobility of macromolecules, particles, cells, and other substances is provided which comprises interacting in a conventional electrophoretic separating procedure, the substances with a polymer-linked affinity compound comprised of a hydrophilic neutral polymer such as polyethylene glycol bound to a second component such as a hydrophobic compound, an immunocompound such as an antibody or antibody active fragment, or a ligand such as a hormone, drug, antigen, or a hapten. The reduction of electrophoretic mobility achieved is directly proportional to the concentration of the polymer-linked affinity compound employed, and such reduction can comprise up to 100 percent for particular particles and cells. The present invention is advantageous in that electrophoretic separation can now be achieved for substances whose native surface charge structure had prevented them from being separated by normal electrophoretic means. Depending on the affinity component utilized, separation can be achieved on the basis of the specific/irreversible, specific/reversible, semi-specific/reversible, relatively nonspecific/reversible, or relatively nonspecific/irreversible ligand-substance interactions.

Vanalstine, James M.↗

Evaluation of heat sink materials for thermal management of lithium batteries

Aluminum, neopentyl glycol (NPG), and resins FT and KT are evaluated theoretically and experimentally as heat sink materials for lithium battery packs. The thermal performances of the two resins are compared in a thermal vacuum experiment. As solutions to the sublimation property were not immediately apparent, a theoretical comparison of the thermal performance of NPG versus KT, Al, and no material, is presented.

Dimpault-Darcy, E. C.↗