Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “germanium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Characterization of Partial Charge Collection Induced by Neutron Damage in High-Purity Germanium Detectors

This paper investigates the correlation of damage induced by neutron interactions and degradation in the spectra of HPGe detectors. As neutrons kinetically interact with germanium crystals, they create interstitial and vacancy defects within the lattice. These defects then interfere with the charge migration of electron-hole pairs and reduce resolution in the observed energy spectrum. The partial charge collection produces observable spectral changes by increasing the peak width and reducing resolution (full width half maximum). A detailed characterization using various check sources was performed before and after iterations of neutron exposure in order to observe the effects of the neutron damage. An additional set of measurements was performed along with characterizations to show the detector’s response at discrete locations on the HPGe crystal. This was done to observe how the spectrum changes when the gamma rays are isolated to regions of various thicknesses of germanium. In order to impart damage, the detector was placed inside a californium shuffler with the face of the detector against the guide tube for the 252 Cf source. For irradiation of the HPGe, the source was then positioned in front of the face of the detector using the stepper motor of the shuffler. The neutron exposure time intervals were recorded and increased based on the initial damage observed. An MCNP simulation was performed to estimate the amount of interactions that occurred in the germanium crystal to ensure enough damage had occurred. Studying the effects that neutron damage imparts on a bullet-type HPGe detector can help provide necessary data to estimate total neutron exposure limits, reduce the likelihood of decisions made on suspect data, and aid in diagnostics of a damaged detector.

36 MATERIALS SCIENCE↗

Segmented Monolithic Germanium Detector Arrays for X-ray Absorption Spectroscopy

The experimental results from the Phase I effort were extremely encouraging. During Phase I PHDs Co. made the first strides toward a new detector technology that could have great impact on synchrotron x-ray absorption (XAS) measurements, and x-ray detector technology in general. Detector hardware that allowed critical demonstration measurements of our technology was designed and fabricated. This new technology allows good charge collection from many pixels on a single side of a multi-element monolithic germanium planar detector. The detector technology provides “dot-like” collection electrodes having very low capacitance. The detector technology appears to perform as anticipated in the Phase I proposal. In particular, the 7-pixel detector studied showed remarkable properties; making it an interesting example of detector physics. The technology is enabled by the use of amorphous germanium contact technology on germanium planar detectors. Because of the scalability associated with the fabrication of these technologies at PHDs Co., we anticipate being able to supply larger detector systems at significantly lower cost than systems made in the conventional manner.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Silicon-germanium technology program of the Jet Propulsion Laboratory.

The outer planetary exploration missions studied by the Jet Propulsion Laboratory require silicon-germanium radioisotope thermoelectric generators (RTGs) in which the factors of safety are as low as is compatible with the reliable satisfaction of the power needs. Work on silicon germanium sublimation performed at the Jet Propulsion Laboratory is presented. Analytical modeling work on the solid-diffusion process involved in the steady-state (free) sublimation of silicon germanium is described. Analytical predictions are made of the sublimation suppression which can be achieved by using a cover gas. A series of accelerated (high-temperature) tests which were performed on simulated hardware (using four SiGe couples) to study long-term sublimation and reaction mechanisms are also discussed.

De Winter, F.↗

The solar abundance of germanium

Spectral scans of the wavelength regions around 3039 A and 3269 A were used as a basis for the determination of the solar abundance of germanium. A solar model similar to the one given by Elste (1968) was used in the analysis of the data. The germanium abundance values obtained are presented in a table. Taking into account an abundance compilation for the solar system conducted by Cameron (1973), it is concluded that the 'solar system' and solar atmospheric abundances of germanium are in accord.

Ross, J. E.↗

Capabilities of germanium detectors

The gamma ray detection efficiency and energy resolution of germanium detectors is reviewed. A general sensitivity equation for gamma-ray detectors is presented and calculated sensitvity curves are shown for a large volume balloon-borne spectrometer using germanium detectors. Improvement anticipated from a planned satellite experiment using germanium detectors is discussed.

Willett, J. B.↗

Present growth technology of silicon germanium alloys and possible advantages of microgravity growth

The growth technology of Silicon-germanium (Si-Ge) alloys and the possible advantages of growth in microgravity is reviewed. The Si-Ge alloys have a continuous variation of bandgap energy from the germanium bandgap to the silicon bandgap. The unusual two slope behavior of Eg versus composition is due to the differences in the conduction band structure between Si and Ge. Below 17% (atomic), the germanium band structure dominates; and above it, the bands are "silicon like". It is found that the growth of Si-Ge alloys in microgravity is very attractive. In particular, the float zone method, in which a liquid zone of controlled starting composition, used to grow a large amount of useful alloy crystal. Large temperature gradients and relatively flat growth interfaces are necessary to obtain homogeneous crystal growth.

Stafsudd, O. M.↗

Extrinsic germanium Blocked Impurity Bank (BIB) detectors

Ge:Ga blocked-impurity-band (BIB) detectors with long wavelength thresholds greater than 190 microns and peak quantum efficiencies of 4 percent, at an operating temperature of 1.8 K, have been fabricated. These proof of concept devices consist of a high purity germanium blocking layer epitaxially grown on a Ga-doped Ge substrate. This demonstration of BIB behavior in germanium enables the development of far infrared detector arrays similar to the current silicon-based devices. Present efforts are focussed on improving the chemical vapor deposition process used to create the blocking layer and on the lithographic processing required to produce monolithic detector arrays in germanium. Approaches to test the impurity levels in both the blocking and active layers are considered.

Krabach, Timothy N.↗

Electronic considerations for externally segmented germanium detectors

The dominant background source for germanium gamma ray detector spectrometers used for some astrophysics observations is internal beta decay. Externally segmented germanium gamma ray coaxial detectors can identify beta decay by localizing the event. Energetic gamma rays interact in the germanium detector by multiple Compton interactions while beta decay is a local process. In order to recognize the difference between gamma rays and beta decay events, the external electrode (outside of detector) is electrically partitioned. The instrumentation of these external segments and the consequence with respect to the spectrometer energy signal is examined.

Madden, N. W.↗

Gamma-ray imaging with germanium detectors

Externally segmented germanium detectors promise a breakthrough in gamma-ray imaging capabilities while retaining the superb energy resolution of germanium spectrometers. By combining existing position-sensitive detectors with an appropriate code aperture, two-dimensional imaging with 0.2-deg angular resolution becomes practical for a typical balloon experiment. Much finer resolutions are possible with larger separations between detectors and the coded aperture as would be applicable for space-based or lunar-based observatories. Two coaxial germanium detectors divided into five external segments have been fabricated and have undergone extensive performance evaluation and imaging testing in our laboratory. These tests together with detailed Monte Carlo modeling calculations have demonstrated the great promise of this sensor technology for future gamma-ray missions.

Mahoney, W. A.↗

Epitaxial Deposition Of Germanium Doped With Gallium

Epitaxial layers of germanium doped with gallium made by chemical vapor deposition. Method involves combination of techniques and materials used in chemical vapor deposition with GeH4 or GeCl4 as source of germanium and GaCl3 as source of gallium. Resulting epitaxial layers of germanium doped with gallium expected to be highly pure, with high crystalline quality. High-quality material useful in infrared sensors.

Huffman, James E.↗

Determining orbital particle parameters of impacts into germanium using morphology analysis and calibration data from hypervelocity impact experiments in the laboratory

This paper describes the work that is done at the Lehrstuhl fur Raumfahrttechnik (lrt) at the Technische Universitat Munchen to examine particle impacts into germanium surfaces which were flown on board the LDEF satellite. Besides the description of the processing of the samples, a brief overview of the particle launchers at our institute is given together with descriptions of impact morphology of high- and hypervelocity particles into germanium. Since germanium is a brittle, almost glass-like material, the impact morphology may also be interesting for anyone dealing with materials such as optics and solar cells. The main focus of our investigations is to learn about the impacting particle's properties, for example mass, velocity and direction. This is done by examining the morphology, various geometry parameters, crater obliqueness and crater volume.

Paul, Klaus G.↗

Defect Density Comparison of Detached versus Attached Bridgman Grown Germanium Crystals

Semiconductor Bridgman growth without contact between the growing crystal and the growth ampoule has been observed on Earth in the last few years during several experiments. Previously, this so-called detached or dewetted growth phenomenon occurred preferentially under microgravity conditions due to the absence of the hydrostatic pressure. Many theoretical as well as experimental investigations helped to provide a better understanding of the mechanism and to identify the parameters leading to the detachment. Thus, recent attempts to get stable detached growth under terrestrial conditions by Duffar et al. growing III-V compounds and our own group with germanium and germanium-silicon alloys were frequently successful. At this conference we present the results of several germanium growth experiments performed in pyrolytic boron nitride containers. To exert an influence on the pressure ratio above and below the melt we used closed-bottom and open-bottom containers. This resulted in mainly detached-grown single crystals with the closed-bottom crucibles and attached single crystals with the open-bottom tubes. Evidence of detached growth is obtained from the crystal surface with a combination of axial profilometer scans and optical and electron microscopy. Detailed investigations of the defect structure, which is the main focus of this presentation, have shown an improvement of the crystal quality in the detached-grown samples, with a strong reduction of the etch pit density by about two orders of magnitude.

Schweizer, M.↗

Temperature-dependent Refractive Index of Silicon and Germanium

Silicon and germanium are perhaps the two most well-understood semiconductor materials in the context of solid state device technologies and more recently micromachining and nanotechnology. Meanwhile, these two materials are also important in the field of infrared lens design. Optical instruments designed for the wavelength range where these two materials are transmissive achieve best performance when cooled to cryogenic temperatures to enhance signal from the scene over instrument background radiation. In order to enable high quality lens designs using silicon and germanium at cryogenic temperatures, we have measured the absolute refractive index of multiple prisms of these two materials using the Cryogenic, High-Accuracy Refraction Measuring System (CHARMS) at NASA's Goddard Space Flight Center, as a function of both wavelength and temperature. For silicon, we report absolute refractive index and thermo-optic coefficient (dn/dT) at temperatures ranging from 20 to 300 K at wavelengths from 1.1 to 5.6 pin, while for germanium, we cover temperatures ranging from 20 to 300 K and wavelengths from 1.9 to 5.5 microns. We compare our measurements with others in the literature and provide temperature-dependent Sellmeier coefficients based on our data to allow accurate interpolation of index to other wavelengths and temperatures. Citing the wide variety of values for the refractive indices of these two materials found in the literature, we reiterate the importance of measuring the refractive index of a sample from the same batch of raw material from which final optical components are cut when absolute accuracy greater than k5 x 10" is desired.

Frey, Bradley J.↗

Germanium Lift-Off Masks for Thin Metal Film Patterning

A technique has been developed for patterning thin metallic films that are, in turn, used to fabricate microelectronics circuitry and thin-film sensors. The technique uses germanium thin films as lift-off masks. This requires development of a technique to strip or undercut the germanium chemically without affecting the deposited metal. Unlike in the case of conventional polymeric lift-off masks, the substrate can be exposed to very high temperatures during processing (sputter deposition). The reason why polymeric liftoff masks cannot be exposed to very high temperatures (greater than 100 C) is because (a) they can become cross linked, making lift-off very difficult if not impossible, and (b) they can outgas nitrogen and oxygen, which then can react with the metal being deposited. Consequently, this innovation is expected to find use in the fabrication of transition edge sensors and microwave kinetic inductance detectors, which use thin superconducting films deposited at high temperature as their sensing elements. Transition edge sensors, microwave kinetic inductance detectors, and their circuitry are comprised of superconducting thin films, for example Nb and TiN. Reactive ion etching can be used to pattern these films; however, reactive ion etching also damages the underlying substrate, which is unwanted in many instances. Polymeric lift-off techniques permit thin-film patterning without any substrate damage, but they are difficult to remove and the polymer can outgas during thin-film deposition. The outgassed material can then react with the film with the consequence of altered and non-reproducible materials properties, which, in turn, is deleterious for sensors and their circuitry. The purpose of this innovation was to fabricate a germanium lift-off mask to be used for patterning thin metal films.

Brown, Ari↗

Influence of Containment on the Growth of Silicon-Germanium: A Materials Science Flight Project

This investigation involves the comparison of results achieved from three types of crystal growth of germanium and germanium-silicon alloys: (1) Float zone growth (2) Bridgman growth (3) Detached Bridgman growth crystal The fundamental goal of the proposed research is to determine the influence of containment on the processing-induced defects and impurity incorporation in germanium-silicon (GeSi) crystals (silicon concentration in the solid up to 5 at%) for three different growth configurations in order to quantitatively assess the improvements of crystal quality possible by detached growth.

Volz, M. P.↗

Slow Crack Growth of Germanium

The fracture toughness and slow crack growth parameters of germanium supplied as single crystal beams and coarse grain disks were measured. Although germanium is anisotropic (A=1.7), it is not as anisotropic as SiC, NiAl, or Cu, as evidence by consistent fracture toughness on the 100, 110, and 111 planes. Germanium does not exhibit significant slow crack growth in distilled water. (n=100). Practical values for engineering design are a fracture toughness of 0.7 MPam and a Weibull modulus of m=6+/-2. For well ground and reasonable handled coupons, fracture strength should be greater than 30 MPa.

Stress Corrosion Susceptibility↗

Influence of Containment on the Growth of Germanium-Silicon in Microgravity

This investigation involves the comparison of results achieved from three types of crystal growth of germanium and germanium-silicon alloys: Float zone growth, Bridgman growth, and Detached Bridgman growth. The fundamental goal of the proposed research is to determine the influence of containment on the processing-induced defects and impurity incorporation in germanium-silicon (GeSi) crystals (silicon concentration in the solid up to 5%) for three different growth configurations in order to quantitatively assess the improvements of crystal quality possible by detached growth.

Volz, M. P.↗

High-quality, single-crystalline silicon-germanium films

High-quality, single-crystalline silicon-germanium (Si.sub.(1-x)Ge.sub.x) having a high germanium content is provided. Layers of the high-quality, single-crystalline silicon-germanium can be grown to high sub-critical thicknesses and then released from their growth substrates to provide Si.sub.(1-x)Ge.sub.x films without lattice mismatch-induced misfit dislocations or a mosaic distribution of crystallographic orientations.

Lagally, Max G.↗