Modeling Framework and Validation of a Smart Grid and Demand Response System for Wind Power Integration

Electricity generation from wind power and other renewable energy sources is increasing, and their variability introduces new challenges to the power system. The emergence of smart grid technologies in recent years has seen a paradigm shift in redefining the electrical system of the future, in which controlled response of the demand side is used to balance fluctuations and intermittencies from the generation side. This paper presents a modeling framework for an integrated electricity system where loads become an additional resource. The agent-based model represents a smart grid power system integrating generators, transmission, distribution, loads and market. The model incorporates generator and load controllers, allowing suppliers and demanders to bid into a Real-Time Pricing (RTP) electricity market. The modeling framework is applied to represent a physical demonstration project conducted on the Olympic Peninsula, Washington, USA, and validation simulations are performed using actual dynamic data. Wind power is then introduced into the power generation mix illustrating the potential of demand response to mitigate the impact of wind power variability, primarily through thermostatically controlled loads. The results also indicate that effective implementation of Demand Response (DR) to assist integration of variable renewable energy resources requires a diversity of loads to ensure functionality of the overall system.

Demand Response↗

Regional water consumption for hydro and thermal electricity generation in the United States

Water is an essential resource for most electric power generation technologies. Thermal power plants typically require a large amount of cooling water whose evaporation is regarded to be consumed. Hydropower plants result in evaporative water loss from the large surface areas of the storing reservoirs. This paper estimated the regional water consumption factors (WCFs) for thermal and hydro electricity generation in the United States, because the WCFs of these power plants vary by region and water supply and demand balance are of concern in many regions. For hydropower, total WCFs were calculated using a reservoir’s surface area, state-level water evaporation, and background evapotranspiration. Then, for a multipurpose reservoir, a fraction of its WCF was allocated to hydropower generation based on the share of the economic valuation of hydroelectricity among benefits from all purposes of the reservoir. For thermal power plants, the variations in WCFs by type of cooling technology, prime mover technology, and by region were addressed. The results show that WCFs for electricity generation vary significantly by region. Finally, the generation-weighted average WCFs of thermoelectricity and hydropower are 1.25 (range of 0.18–2.0) and 16.8 (range of 0.67–1194) L/kWh, respectively, and the generation-weighted average WCF by the U.S. generation mix in 2015 is estimated at 2.18 L/kWh.

13 HYDRO ENERGY↗

The Impact of CCS Readiness on the Evolution of China's Electric Power Sector

In this study, GCAM-China is exercised to examine the impact of CCS availability on the projected evolution of China’s electric power sector under the Paris Increased Ambition policy scenario developed by Fawcett et al. based on the Intended Nationally Determined Contributions (INDCs) submitted under the COP-21 Paris Agreement. This policy scenario provides a backdrop for understanding China’s electric generation mix over the coming century under several CCS availability scenarios: CCS is fully available for commercial-scale deployment by 2025; by 2050; by 2075; and CCS is unavailable for use in meeting the modelled mitigation targets through 2100. Without having CCS available, the Chinese electric power sector turns to significant use of nuclear, wind, and solar to meet growing demands and emissions targets, at a cost. Should large-scale CCS deployment be delayed in China by 25 years, the modeled per-ton cost of climate change mitigation is projected to be roughly $420/tC (2010 US dollars) by 2050, relative to $360/tC in the case in which CCS is available to deploy by 2025, a 16% increase. Once CCS is available for commercial use, mitigation costs for the two cases converge, equilibrating by 2085. However, should CCS be entirely unavailable to deploy in China, the mitigation cost spread, compared to the 2025 case, doubles by 2075 ($580/tC and $1130/tC respectively), and triples by 2100 ($1050/tC vs. $3200/tC). However, while delays in CCS availability may have short-term impacts on China’s overall per-ton cost of meeting the emissions reduction target evaluated here, as well as total mitigation costs, the carbon price is likely to approach the price path associated with the full CCS availability case within a decade of CCS deployment. Having CCS available before the end of the century, even under the delays examined here, could reduce the total amount of nuclear and renewable energy that must deploy, reducing the overall cost of meeting the emissions mitigation targets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cooperation or Rivalry? Impact of alternative development pathways on India's long-term electricity generation and associated water demands

The world has witnessed a significant shift in the last decade in the way countries interact with each other. A cooperation based international paradigm is being challenged by countries engaging in rivalry with each other in the name of their national interests. What developmental pathway the world charts in the future is going to be path defining for global energy and emissions use. India, expected to play a critical role in the emissions mitigation debate, would contribute to and would be impacted by these pathways. In India specific literature, however, little attention has been paid to development pathways related uncertainties and their impact on energy futures. We seek to address this gap by modelling India's electricity futures and associated water demands under different development pathways. Our analysis shows that alternative development pathways would have significantly different implications for the energy access, electricity generation mix, associated water withdrawals, and carbon dioxide emissions in India. We conclude by arguing that energy, emissions and water policies should be conceived with an explicit understanding of uncertainties related to potential development pathways that the world and India can chart.

India, Electricity-Water Nexus, Development Pathwa↗

Emissions implications of downscaled electricity generation scenarios for the western United States

This study explores how emissions from electricity generation in the Western Interconnection region of the U.S. might respond in circa 2030 to contrasting scenarios for fuel prices and greenhouse gas (GHG) emissions fees. We examine spatial and temporal variations in generation mix across the region and year using the PLEXOS unit commitment and dispatch model with a production cost model database adapted from the Western Electricity Coordinating Council. Emissions estimates are computed by combining the dispatch model results with unit-specific, emissions-load relationships. Wind energy displaces natural gas and coal in scenarios with relatively expensive natural gas or with GHG fees. Correspondingly, annual emissions of NOx, SO2, and CO2 are reduced by 20-40% in these cases. NOx emissions, which are a concern as a precursor of ground-level ozone, are relatively high and consistent across scenarios during summer, when peak electricity loads occur and wind resources in the region are comparatively weak. Accounting for the difference in start-up versus stabilized NOx emissions rates for natural gas plants had little impact on region-wide emissions estimates due to the dominant contribution from coal-fired plants, but would be more important in the vicinity of the natural gas units.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Role of Energy Storage in the Uptake of Renewable Energy: A Model Comparison Approach

The power sector needs to ensure a rapid transition towards a low-carbon energy system to avoid the dangerous consequences of greenhouse gas emissions. Storage technologies are a promising option to provide the power system with the flexibility required when intermittent renewables are present in the electricity generation mix. This paper focuses on the role of electricity storage in energy systems with high shares of renewable sources. The study encompasses a model comparison approach where four models (GENeSYS-MOD, MUSE, NATEM, and urbs - MX) are used to analyse the storage uptake in North America. The analysis addresses the conditions affecting storage uptake in each country and its dependence on resource availability, technology costs, and public policies. Results show that storage may promote emissions reduction at lower costs when renewable mandates are in place whereas in presence of carbon taxes, renewables may compete with other low-carbon options. The study also highlights the main modelling approach shortcomings in the modelling of electricity storage in integrated assessment models.

electricity storage↗

Cost and life cycle analysis for deep CO 2 emissions reduction of steelmaking: Blast furnace-basic oxygen furnace and electric arc furnace technologies

Iron and steel manufacturing is the largest contributor to CO 2 emissions among heavy industries worldwide. This is mostly due to the use of coal in blast furnace-basic oxygen furnace (BF-BOF) process for virgin (primary) steel production. The electricity generation mix used in the electric arc furnace (EAF) process to recycle scrap steel also contributes to the CO 2 emission associated with secondary steel production. To decarbonize iron and steel sector, we investigated decarbonization options for BF-BOF and EAF processes, including energy efficiency, carbon capture and storage, and the use of clean energy sources, in various BF-BOF and EAF process configurations. Additionally, for each decarbonization approach, we evaluated the CO 2 reduction potential via life cycle analysis (LCA) and estimated the associated cost through techno-economic analysis (TEA). A typical U.S. BF-BOF for virgin steel production has a cradle-to-gate (CTG) CO 2 emissions of 1,990 kg/MT steel with a levelized cost of steel (LCOS) of $\$439$/MT steel, while a typical U.S. EAF process for secondary steel production in the United States has a CTG CO 2 emissions of 270 kg/MT steel with a LCOS of $\$365$/MT steel. Combining renewable energy sources and carbon capture, BF-BOF CTG CO 2 emissions can be reduced to 16 kg/MT steel, and EAF configurations can achieve similar deep reductions to reach 25 kg/MT steel. The corresponding LCOS with these decarbonization levels is estimated to increase to $\$542$/MT steel and $\$348$/MT steel, respectively. The estimated CO 2 avoidance costs vary from -$\$90$/MT CO 2 to $\$646$/MT CO 2 , depending on the various decarbonization technologies and energy prices.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Comparative life cycle analysis on ethylene production from electrocatalytic reduction of carbon dioxide

Ethylene is one of the largest greenhouse gas emitters and the most diversly used commodity chemicals globally. Electrocatalytic reduction of CO 2 to ethylene received great attention from the research society to decarbonize the ethylene production. Here, in this study, a life-cycle analysis is conducted using the Greenhouse Gases, Regulated Emissions, and Energy use in Technologies (GREET) model on the three electrocatalytic CO 2 -reduction pathways (or “e-ethylene” pathways): i) cascade conversion via carbon monoxide intermediate; ii) single-step conversion in membrane electrode assembly (MEA); and iii) single-step conversion in alkaline flow cell. The results showed that the electricity consumption is the lowest for the cascade pathway (164 MJ/kg), thus resulting in the lowest cradle-to-gate carbon intensity [18 kgCO 2 e/kg with United States (US) average grid)] among the three pathways followed by the single-step MEA (32 kgCO 2 e/kg) and then by the single-step alkaline (56 kgCO 2 e/kg). However, all three e-ethylene pathways were significantly more carbon-intensive than their fossil-based counterpart (1.1 kgCO 2 e/kg) due to their excessive energy consumption with the current state of technology. With renewable electricity, all three pathways yielded negative carbon intensity: from -3.1 kgCO 2 e/kg to -1.6 kgCO 2 e/kg depending on the source of CO 2 . The threshold carbon intensity of electricity (TCIE), defined as the upper bound of the carbon intensity of electricity to achieve lower carbon intensity for e-ethylene compared to fossil-based ethylene, is calculated for both current and future state of e-ethylene technologies. The cascade pathway had the highest TCIE out of the three e-ethylene pathways for both current (92 gCO 2 e/kWh) and future (124 gCO 2 e/kWh) state of technologies. However, the carbon intensity of average US grid (i.e., 467 and 303 gCO 2 e/kWh for current and future projections) were higher than the TCIEs of the corresponding timeline. Thus, reducing electricity requirement for e-ethylene pathways and bringing low-carbon generation mix in the United States (US) grid faster than the current projection are both essential to decarbonize ethylene and its downstream chemicals/polymers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Accelerating Photovoltaic Market Entry with Module Replacement

Today's approach to deploying solar photovoltaics (PV) implicitly assumes that module technology is fixed. Solar panels are installed and expected to operate for the system life of 30 years or more. However, many PV technologies are improving rapidly along several dimensions, including cost, power conversion efficiency, and reliability. Periodic module replacement or planned repowering takes advantage of this technological improvement and counteracts predictable degradation. Here, we show that a module replacement strategy allows a competitive levelized cost of electricity to be achieved with an initial module lifetime of less than 15 years, assuming backward compatibility with the original system design. We also assess the life-cycle environmental impacts of module replacement and find that all commercial PV technologies offer benefits in the majority of impact categories, regardless of the replacement strategy, compared to today's electric generation mix. Module replacement can thus accelerate the market introduction and decarbonization impact of emerging PV technologies that have achieved a competitive module efficiency (=20%), cost (=$0.30/W), and lifetime (=10 years) and have the potential to improve further on all three metrics but lack decades-long field deployment experience.

14 SOLAR ENERGY↗

Influence of aluminum source and Ni/Al ratio in a batch stirred tank reactor on the structure, morphology, and electrochemical performance of Ni-rich NMA cathodes

Here, the structural, morphological, and electrochemical performance of Ni-rich LiNi 0.9 Mn 0.05 Al 0.05 O 2 (955NMA) and LiNi 0.85 Mn 0.05 Al 0.1 O 2 (85,510) cathodes strongly depends on the properties of their hydroxide precursors. Ni-Mn-Al hydroxide precursors were synthesized through controlled co-precipitation in a batch stirred tank reactor, where pH, reaction time, metal-ion feed rate, aluminum source, and aluminum concentration were systematically varied to tailor particle morphology, phase composition, and dopant distribution. Two aluminum sources, aluminum nitrate and sodium aluminate produced two distinct hydroxide precursors NMA(OH) 2 -1 and NMA(OH) 2 -2, which were lithiated to form LiNMA1 (Li 0.992 [Ni 0.905 Mn 0.049 Al 0.046 ]O 2 ) and LiNMA2 (Li 0.990 [Ni 0.850 Mn 0.047 Al 0.103 ]O 2 ). Structural and compositional analyses revealed that aluminum incorporation and phase formation in Ni–Mn–Al hydroxides are governed by local supersaturation and interfacial growth kinetics. Rapid dilute aluminum addition produced aluminum-free β-phase hydroxides, intermediate conditions generated mixed α/β phases, whereas slow concentrated dosing enabled uniform aluminum incorporation and stabilization of the β-phase structure. LiNMA1 delivers a high initial discharge capacity of 223 mAhg −1 but significant capacity fading with 67% retention after 100 cycles, associated with structural instability. In contrast, LiNMA2 delivers a lower initial capacity 172 mAhg −1 yet excellent cycling stability 91% retention, attributed to improved TM–O framework stability and reduced cation disorder.

Capacity↗

MgCoAl and NiCoAl LDHs synthesized by the hydrothermal urea hydrolysis method: Structural characterization and thermal decomposition

Highlights: • We synthesized MgCoAl and NiCoAl LDHs by the urea hydrolysis method. • Aluminum rich and crystalline materials have been formed. • The calcination of the LDHs generated mixed oxides with high surface areas. - Abstract: Layered double hydroxides (LDHs) with Mg/Co/Al and Ni/Co/Al were synthesized for the first time by the urea hydrolysis method. The experimental conditions promoted aluminum rich and crystalline materials. The formation of LDHs was investigated by powder X-ray diffraction (XRD), chemical analysis, solid state nuclear magnetic resonance with magic angle spinning ({sup 27}Al-MAS-NMR), simultaneous thermogravimetric/differential thermal analysis (TGA/DTA), FTIR spectroscopy, scanning electron microscopy (SEM), and N{sub 2} adsorption–desorption experiments. A single phase corresponding to LDH could be obtained in all the investigated compositions. Thermal calcination of these LDHs at 500 °C resulted in the formation of solid solutions in which Al{sup 3+} was dissolved. All the calcined materials have rock-salt like structures and high surface areas.

36 MATERIALS SCIENCE↗

Exploring the impact of increased solar deployment levels on residential electricity bills in India

Here, in this study, the impact of increased solar penetration in the electricity generation mix on residential electricity consumer bills is explored. The study comprises of two sections: simulation of wholesale electricity rates and retail rate modeling. In the first stage, wholesale prices were modeled using a bottom-up long term unit commitment optimization model for different energy mix scenarios based on increased solar penetration, ranging from 5 to 40% on energy basis. The simulations indicated a fall in wholesale prices with increased solar penetration, a result of merit order effect. The simulated wholesale prices were then used to model retail rates for residential consumers. Four different types of retail rates were designed: flat rate, real time pricing, time of use and critical peak pricing. The impact of these retail rate mechanisms on electricity bills of residential consumers was analyzed and it was found that the bill savings achieved from time varying rates are greater than for time invariant rates. With increased solar penetration, customers with time-varying rates are likely to benefit the most from electricity bill savings. Although consumers with flat rate gain bill savings with increased solar penetration, the savings are likely to be lower than with time-varying rates.

14 SOLAR ENERGY↗

Complementary relationship between small-hydropower and increasing penetration of solar photovoltaics: Evidence from CAISO

To achieve the 100% green electricity goal, we need to understand the relationship between resources in the market and identify the flexible clean resources (i.e., hydropower) to integrate power from wind and photovoltaic (PV). This paper reveals a complementary relationship between small hydropower plants and solar PVs in the California Independent System Operator (CAISO) based on the system-wide hourly generation data from 2013 to 2017. When the solar PV increases its portion in the generation mix by 1%, small hydro will increase its portion by 0.01–0.06%. Such response is obvious in the net demand peak hours, both morning and evening. The low operation cost, flexibility, and dispatchability of small hydro in CAISO explain this complementarity. Due to its benefit in emission and low Levelized Cost of Electricity (LCOE), it is suggested to consider more small hydro projects to accommodate additional PV capacity for the 100% green electricity goal. Our estimation indicates that the current feasible potential of small hydro is sufficient, if the relation stays the same over years. If developers can mitigate the environmental impact, more technical potential will become feasible. Thus, small hydro could integrate more solar PV and reduce the demand for natural gas plants and batteries.

13 HYDRO ENERGY↗

Impacts of Solar Land Availability on the Evolution of the U.S. Power System

Long-term planning scenarios of the United States electricity system have not identified solar resource availability to be a limiting factor in how much solar capacity might be deployed. However, there are some smaller regions where siting challenges indicate solar deployment could be limited by solar resource availability. In this work, we use geospatial modeling tools to develop a restrictive siting scenario that significantly reduces the amount and location of utility-scale solar resources. We use that restrictive siting regime, along with other previously defined siting scenarios, to examine how solar resource availability impacts the buildout of the electricity system using business-as-usual and decarbonization futures in a national-scale capacity expansion model. The restrictive siting scenario uses observed siting pressures to exclude many types of land on which development is allowed today and results in a greater than 90% reduction in solar resource potential-to approximately 3000 GW. Even with this drastic reduction, utility-scale solar capacity grows by more than 3 times through 2050 in the business-as-usual scenarios and by more than 6 times in the decarbonization scenarios, though less solar is deployed in scenarios with lower available solar resource. We quantify how system costs and generation mixes change as solar resource availability changes.

14 SOLAR ENERGY↗

The importance of combined cycle generating plants in integrating large levels of wind power generation

Integration of high wind penetration levels will require fast-ramping combined cycle and steam cycles that, due to higher operating costs, will require proper pricing of ancillary services or other forms of compensation to remain viable. Several technical and policy recommendations are presented to help realign the generation mix to properly integrate the wind. (author)

17 WIND ENERGY↗

Capacity contributions of Southern Oregon offshore wind to the Pacific Northwest and California

Variable renewable energy generation poses unique capacity challenges, which increasingly depend on weather events at varying timescales. Facilitated by transmission planning, geographic and technological diversity of the generation fleet may provide a mitigation to capacity shortfalls. In this work, offshore wind (OSW) energy is sited in the areas off the West Coast between Coos Bay, Oregon, and Crescent City, California. Three generation and transmission scenarios are modeled within the Western Interconnection: (i) 3.4 gigawatts (GW) of installed OSW capacity connected to Southern Oregon through a High Voltage Alternating Current (HVAC) Radial Topology in 2030; (ii) 12.9 GW of installed OSW capacity connected to Washington, Oregon, and California through a High Voltage Direct Current (HVDC) Radial Topology post-2030, and (iii) the same 12.9 GW connected to the same locations through a Multi-terminal DC (MTDC) Backbone Topology post-2030. Zonal dispatch simulations assuming coincident wind, solar, and hydropower production and loads over 18 meteorological years, accounting for temperature-dependent equipment derating and forced outages, serve as inputs to the Associated System Capacity Contribution (ASCC) methodology. The capacity credit is 33%, 25% and 34% for the 2030 HVAC Radial Topology, 2030+ HVDC Radial Topology, and 2030+ MTDC Backbone Topology, respectively. Transmission design is shown to mitigate the typical erosion of marginal capacity contribution as more OSW is developed, underscoring the opportunity for grid modernization while decarbonizing the generation mix.

17 WIND ENERGY↗

Tandem chemocatalysis and biological funneling to valorize lignin

In 2014, Linger et al. presented a tandem process for lignin valorization by integrating chemical and biological catalysis. Chemical pretreatment of corn stover generated mixed lignocellulose-derived monomers that were converted to a single product, polyhydroxyalkanoates, by Pseudomonas putida. Tandem processes have since been developed for diverse feedstocks to support the bioeconomy.

09 BIOMASS FUELS↗