Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “full stack”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Experimental Determination of Exhaust Gas Thrust, Special Report

This investigation presents the results of tests made on a radial engine to determine the thrust that can be obtained from the exhaust gas when discharged from separate stacks and when discharged from the collector ring with various discharge nozzles. The engine was provided with a propeller to absorb the power and was mounted on a test stand equipped with scales for measuring the thrust and engine torque. The results indicate that at full open throttle at sea level, for the engine tested, a gain in thrust horsepower of 18 percent using separate stacks, and 9.5 percent using a collector ring and discharge nozzle, can be expected at an air speed of 550 miles per hour.

Pinkel, Benjamin↗

GeantV: Results from the Prototype of Concurrent Vector Particle Transport Simulation in HEP

Full detector simulation was among the largest CPU consumers in all CERN experiment software stacks for the first two runs of the Large Hadron Collider. In the early 2010s, it was projected that simulation demands would scale linearly with increasing luminosity, with only partial compensation from increasing computing resources. The extension of fast simulation approaches to cover more use cases that represent a larger fraction of the simulation budget is only part of the solution, because of intrinsic precision limitations. The remainder corresponds to speeding up the simulation software by several factors, which is not achievable by just applying simple optimizations to the current code base. In this context, the GeantV R&D project was launched, aiming to redesign the legacy particle transport code in order to benefit from features of fine-grained parallelism, including vectorization and increased locality of both instruction and data. This paper provides an extensive presentation of the results and achievements of this R&D project, as well as the conclusions and lessons learned from the beta version prototype.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Computational Fluid Dynamics Modeling to Facilitate Qualification of Stack Sampling Probe Location

Computational fluid dynamics (CFD) modeling was used to help evaluate modifications to a radiological effluent stack and assist with establishing a stack sampling location that met the mixing criteria for qualification. Requirements for stack sampling location are listed in the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-2021 standard. Modeling was performed to help develop a suitable design for increasing building ventilation for the radiological effluent stack. The ANSI/HPS N13.1-2021 criteria for the air monitoring probe location are that the coefficient of variation of velocity uniformity, gaseous tracer uniformity, and particulate tracer uniformity must be less than or equal to 20%. Furthermore, no point in the sampling location may have a gaseous tracer concentration that varies from the mean concentration by more than 30%. Additionally, the flow angle at the sampling location must not be more than 20 degrees. The ANSI/HPS N13.1-2021 standard allows for models (physical or computational) to be employed to perform the full suite of qualification tests, followed by a more limited set of verification tests on the actual stack to qualify the stack sampling location. Here, a series of computational model simulations were employed to evaluate the stack qualification criteria. Significant time and re-source savings are achieved using CFD modeling. CFD modeling demonstrated that the stack meets the criteria at the sample probe location. Verification tests were performed on the modified stack to measure the velocity uniformity and flow angle at the stack sampling location, and results demonstrated that the CFD model results may be used to support the qualification of the stack sampling location.

Air Monitoring↗

Qualification of ANSI/HPS N13.1-2011 Mixing Criteria by Computational Fluid Dynamics Modeling for the 3430 Building Fan Addition and Increased Ventilation Capacity

Additional ventilation capacity has been designed for the 3430 Building filtered exhaust stack system. The updated system will increase the number of fans from two to three and include new ductwork with a larger diameter to integrate the new fan into the existing stack. Stack operations will involve running various fan combinations at any given time. The air monitoring system of the existing two-fan stack previously was found to comply with the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard. Full-scale, three-dimensional computational fluid dynamics (CFD) modeling was used to evaluate the modified three-fan system for compliance with the ANSI/HPS N13.1-2011 standard, which essentially is equivalent to the ANSI/HPS N13.1-1999 standard. The four mixing criteria evaluated are 1) flow angle, 2) velocity, 3) gas tracer, and 4) particle tracer. Benchmarking of the CFD modeling methodology showed good agreement with previous testing used to qualify the stack, and modeling of the existing two-fan system showed good agreement with test data collected from the 3430 Building stack. Modeling was performed to develop a suitable three-fan design. Initial modeling of the three-fan design and basic ductwork showed that flow angles and velocity uniformity were acceptable; however, the gas tracer and particle tracer mixing results were not acceptable. To meet ANSI/HPS N13.1-2011 criteria, an air blender was added to the stack design.

42 ENGINEERING↗

Qualification of ANSI/HPS N13.1-2011 Mixing Criteria by Computational Fluid Dynamics Modeling for the 3430 Building Fan Addition and Increased Ventilation Capacity

Additional ventilation capacity has been designed for the 3430 Building filtered exhaust stack system. The updated system will increase the number of fans from two to three and include new ductwork with a larger diameter to integrate the new fan into the existing stack. Stack operations will involve running various fan combinations at any given time. The air monitoring system of the existing two-fan stack previously was found to comply with the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard. Full-scale, three-dimensional computational fluid dynamics (CFD) modeling was used to evaluate the modified three-fan system for compliance with the ANSI/HPS N13.1-2011 standard, which essentially is equivalent to the ANSI/HPS N13.1-1999 standard. The four mixing criteria evaluated are 1) flow angle, 2) velocity, 3) gas tracer, and 4) particle tracer. Benchmarking of the CFD modeling methodology showed good agreement with previous testing used to qualify the stack, and modeling of the existing two-fan system showed good agreement with test data collected from the 3430 Building stack. Modeling was performed to develop a suitable three-fan design. Initial modeling of the three-fan design and basic ductwork showed that flow angles and velocity uniformity were acceptable; however, the gas tracer and particle tracer mixing results were not acceptable. To meet ANSI/HPS N13.1-2011 criteria, an air blender was added to the stack design. This revision models the individual maximum fan reduced flow capacity from 38,000 cfm to 31,200 cfm; no changes to the duct design are made.

42 ENGINEERING↗

Performance of stainless steel interconnects with (Mn,Co) 3 O 4 -Based coating for solid oxide electrolysis

Mixed transition-metal oxide coatings are commonly applied to stainless steel interconnects for solid oxide cell stacks. Such coatings reduce oxidation and Cr evaporation rates, leading to improved degradation rate and stack lifetime. Here, the ChromLok™ MCO-based composition (Mn,Co) 3 O 4 is applied to Crofer 22 APU stainless steel and evaluated specifically for application in solid oxide electrolyzer stacks operating around 800 °C and utilizing oxygen-ion-conducting solid oxide cells. The MCO coating is found to decrease the stainless steel oxidation rate by about one order of magnitude, and decrease the Cr evaporation rate by fourfold. Furthermore, the coating also dramatically lowers the rate of area-specific resistance increase for stainless steel coupons oxidized for 500 h with constant current applied, from 33 mΩ*cm 2 kh -1 for an uncoated coupon to less than 4 mΩ*cm2 kh -1 for coated coupons. The coating is demonstrated on full-scale interconnects for single-cells, where the coating dramatically reduces degradation rate, and for a stack, which displays stable operation for 700 h.

08 HYDROGEN↗

Qualification of Mixing Criteria by Computational Fluid Dynamics Modeling for the 325 Building Stack Revision

Additional ventilation capacity has been designed for the 325 Building filtered exhaust stack system. The four (4) existing main facility exhaust fans are past the end of their useful life. The fans are being replaced to provide additional exhaust capacity for future growth and to provide a more robust system. Stack operations will involve running various fan combinations at any given time. The air monitoring system of the existing stack previously was found to comply with the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard. Full-scale, three-dimensional computational fluid dynamics (CFD) modeling was used to evaluate the modified four-fan system for compliance with the ANSI/HPS N13.1-2021 standard, which essentially is equivalent in mixing requirements to the ANSI/HPS N13.1-1999 standard (and ANSI/HPS N13.1-2011). The four mixing criteria evaluated are 1) flow angle, 2) velocity, 3) gas tracer, and 4) particle tracer. In addition to the evaluating the modified four-fan system a temporary single fan stack configuration was also evaluated with CFD modeling. The temporary stack is planned to be used while the four-fan system is being modified. Modeling of the modified four-fan design and temporary ductwork showed that flow angles, velocity uniformity, gas tracer, and particle tracer were acceptable.

42 ENGINEERING↗

Distorted dislocation cores and asymmetric glide resistances in titanium

The determination of Critical Resolved Shear Stress (CRSS) in titanium for basal, prismatic, and pyramidal slip-planes without empirical constants is presented by combining Density Functional Theory (DFT) and anisotropic elasticity. A new mechanism leading to tension-compression (T-C) asymmetry in the CRSS levels has been revealed for the first time. The conditions for this asymmetry are established, involving a complex interplay between the dislocation core-structure and core-advance behavior. The three conditions for T-C asymmetry that need to be simultaneously satisfied can be summarized as: (1) a medium stacking fault width, d, (3 < d/b F < 10, where b F is the magnitude of the Burgers vector of the full dislocation), (2) an asymmetric core-structure of the extended dislocation (ξ 1 ≠ ξ 2 , where ξ 1 and ξ 2 are the core-widths of the first and second partials, respectively), and (3) intermittent motion of the partials (Δd/b F ≠ 0, where Δd is the magnitude of fluctuation in stacking fault width during intermittent motion). Pyramidal-slip in titanium satisfies all three conditions, resulting in significant T-C asymmetry. The CRSS theory considers a Wigner-Seitz (W-S) cell based domain area assigned to each lattice site for the calculations of core-energies accurately capturing the slip-plane lattice. The W-S based approach is essential due to the lower symmetry of the HCP crystal circumventing potential errors associated with the one-dimensional atomic-row approximation. Dislocation core structures are obtained for all the slip-systems in titanium showing significant distortion of the disregistry profile governing the core-advance behavior. The CRSS values predicted from the theory show agreement with the experimental CRSS levels reported in the literature.

Dislocation core↗

Full-film dry transfer of MBE-grown van der Waals materials

Abstract Molecular beam epitaxy (MBE) has been used to create high-quality, large-scale two-dimensional van der Waals (2D vdW) materials. However, due to the strong adhesion between the substrate and deposited materials, the peel-off and dry transfer of MBE-grown vdW films onto other substrates has been challenging. This limits the study and use of MBE films for heterogeneous integration including stacked and twisted heterostructures. In this work, we develop a polymer-assisted dry transfer method and successfully perform full-film transfer of various MBE-grown 2D vdW materials including transition metal dichalcogenides, topological insulators and 2D magnets. In particular, we transfer air-sensitive 2D magnets, characterize their magnetic properties, and compare them with as-grown materials. The results show that the transfer technique does not degrade the magnetic properties, with the Curie temperature and hysteresis loops exhibiting similar behaviors after the transfer. Our results enable further development of heterogeneous integration of 2D vdW materials based on MBE growth.

Li, Ziling (ORCID:0000000203537036)↗

A Self-Healable Sulfide/Polymer Composite Electrolyte for Long-Life, Low-Lithium-Excess Lithium-Metal Batteries

Solid electrolyte-protected lithium-metal anodes promise energy-dense, safe cells. While sulfide solid electrolytes enable facile processability and fast ion transport, they suffer from complex chemo-mechanical issues, including Li plating-induced fracture and Li stripping-induced contact loss. To address these issues, a grafting approach is implemented to functionalize the sulfide solid electrolyte (Li 3,85 Sn 0.85 Sb 0.15 S 4 ) with a self-healing unit. This leads to a dynamic bonding between the solid electrolyte network and a mechanically robust polymer scaffold, which reversibly accommodates the volume changes of the lithium-metal anode. Thus, the approach improves the interfacial contact between the lithium-metal anode and the composite electrolyte, enabling stable cycling at a mild stack pressure (160 kPa). With a negative to positive capacity ratio equals to 1, pouch full cells with a high-nickel cathode (nickel content > 90%) and lithium-metal anode display 92% capacity retention for 140 cycles. Engineering the interface between solid electrolyte and the polymeric binder offers a promising pathway to address the chemo-mechanical issues.

36 MATERIALS SCIENCE↗

Characterization of a Multilayered Dielectric Transmissive Phase Modulator

We describe a multilayered dielectric stack configuration designed specifically for use as a transmissive phase modulator for broadband optical signals. Applications for this device range from full aperture wavefront correction to nonmechanical beam steering arrays for free space optical communication links. Our implementation employs alternating GaAs and AlAs layers of varying thickness on a GaAs substrate to create a bandpass region of high average transmission centered about the one micrometer wavelength. Within this transmission bandpass, the phase component of the complex transmission coefficient varies in a near-linear fashion with respect to wavelength. The transmission bandpass is designed to have a bandwidth of 21.0 nm (or 6.3THz frequency bandwidth) and to have an edge-to-edge phase change of greater than 47T radians. Modification of the stack materials' optical properties causes the transmission profile to shift spectrally, resulting in a phase modulation for bands of transmitted frequencies. Our broadband phase modulator imparts up to a full-cycle of phase modulation with low loss and low group velocity dispersion. We identify several methods for implementing the requisite modulation, including refractive index modulation through free carrier injection and optical path length modulation through variation in angle of incidence. At least one sample comprising 91 alternating layers has been fabricated to exhibit the bandpass properties required for optical signal phase modulation. We experimentally characterize the sample using an interferometer and spectrometer to measure the transmitted signal spectrum and relative phase modulation. We compare the experimental data to computational predictions and discuss the results.

Keys, Andrew S.↗

Refreshable Braille Displays Using EAP Actuators

Refreshable Braille can help visually impaired persons benefit from the growing advances in computer technology. The development of such displays in a full screen form is a great challenge due to the need to pack many actuators in small area without interferences. In recent years, various displays using actuators such as piezoelectric stacks have become available in commercial form but most of them are limited to one line Braille code. Researchers in the field of electroactive polymers (EAP) investigated methods of using these materials to form full screen displays. This manuscript reviews the state of the art of producing refreshable Braille displays using EAP-based actuators..

Electroactive Polymers↗

Mechanical Design and Development of TES Bolometer Detector Arrays for the Advanced ACTPol Experiment

The next generation Advanced ACTPol (AdvACT) experiment is currently underway and will consist of four Transition Edge Sensor (TES) bolometer arrays, with three operating together, totaling 5800 detectors on the sky. Building on experience gained with the ACTPol detector arrays, AdvACT will utilize various new technologies, including 150 mm detector wafers equipped with multichroic pixels, allowing for a more densely packed focal plane. Each set of detectors includes a feedhorn array of stacked silicon wafers which form a spline pro le leading to each pixel. This is then followed by a waveguide interface plate, detector wafer, back short cavity plate, and backshort cap. Each array is housed in a custom designed structure manufactured from high purity copper and then gold plated. In addition to the detector array assembly, the array package also encloses cryogenic readout electronics. We present the full mechanical design of the AdvACT high frequency (HF) detector array package along with a detailed look at the detector array stack assemblies. This experiment will also make use of extensive hardware and software previously developed for ACT, which will be modi ed to incorporate the new AdvACT instruments. Therefore, we discuss the integration of all AdvACT arrays with pre-existing ACTPol infrastructure.

Advanced ACTPol (AdvACT)↗

Long-exposure NuSTAR constraints on decaying dark matter in the Galactic halo

Here, we present two complementary NuSTAR x-ray searches for keV-scale dark matter decaying to monoenergetic photons in the Milky Way halo. In the first, we utilize the known intensity pattern of unfocused stray light across the detector planes—the dominant source of photons from diffuse sources—to separate astrophysical emission from internal instrument backgrounds using ~7- Ms/detector deep blank-sky exposures. In the second, we present an updated parametric model of the full NuSTAR instrument background, allowing us to leverage the statistical power of an independent ~20-Ms/detector stacked exposures spread across the sky. Finding no evidence of anomalous x-ray lines using either method, we set limits on the active-sterile mixing angle sin 2 ⁡(2⁢θ) for sterile-neutrino masses 6–40 keV. The first key result is that we strongly disfavor a ~7-keV sterile neutrino decaying into a 3.5-keV photon. The second is that we derive leading limits on sterile neutrinos with masses ~15–18 keV and ~25–40 keV, reaching or extending below the big bang nucleosynthesis limit. In combination with previous results, the parameter space for the neutrino minimal standard model is now nearly closed.

79 ASTRONOMY AND ASTROPHYSICS↗

Time-Integrated Neutrino Source Searches with 10 Years of IceCube Data

This Letter presents the results from pointlike neutrino source searches using ten years of IceCube data collected between April 6, 2008 and July 10, 2018. We evaluate the significance of an astrophysical signal from a pointlike source looking for an excess of clustered neutrino events with energies typically above ~1 TeV among the background of atmospheric muons and neutrinos. We perform a full-sky scan, a search within a selected source catalog, a catalog population study, and three stacked Galactic catalog searches. The most significant point in the northern hemisphere from scanning the sky is coincident with the Seyfert II galaxy NGC 1068, which was included in the source catalog search. The excess at the coordinates of NGC 1068 is inconsistent with background expectations at the level of 2.9σ after accounting for statistical trials from the entire catalog. The combination of this result along with excesses observed at the coordinates of three other sources, including TXS 0506+056, suggests that, collectively, correlations with sources in the northern catalog are inconsistent with background at 3.3σ significance. The southern catalog is consistent with background. Finally these results, all based on searches for a cumulative neutrino signal integrated over the 10 years of available data, motivate further study of these and similar sources, including time-dependent analyses, multimessenger correlations, and the possibility of stronger evidence with coming upgrades to the detector.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and Execution of the Hypersonic Inflatable Aerodynamic Decelerator Large-Article Wind Tunnel Experiment

The testing of 3- and 6-meter diameter Hypersonic Inflatable Aerodynamic Decelerator (HIAD) test articles was completed in the National Full-Scale Aerodynamics Complex 40 ft x 80 ft Wind Tunnel test section. Both models were stacked tori, constructed as 60 degree half-angle sphere cones. The 3-meter HIAD was tested in two configurations. The first 3-meter configuration utilized an instrumented flexible aerodynamic skin covering the inflatable aeroshell surface, while the second configuration employed a flight-like flexible thermal protection system. The 6-meter HIAD was tested in two structural configurations (with and without an aft-mounted stiffening torus near the shoulder), both utilizing an instrumented aerodynamic skin.

Cassell, Alan M.↗

Investigation of long-term light stability of negative charge injected into oxide-nitride-oxide passivation stack of crystalline silicon solar cells

A negatively charged oxide-nitride-oxide stack for field-effect passivation of crystalline silicon solar cells is discussed. The negative charge was injected into the stack by a plasma charge injection technology. Charge stability was studied by exposing samples to AM1.5 simulation visible light and full-spectrum light at temperatures ranging from 55 to 78 °C for up to 300 h. Charge injection and loss were quantified based on shifts in the flatband voltage of capacitance–voltage curves measured with a mercury probe. The most probable mechanism of charge loss was found to be diffusion of negative charged hydrogen atoms through nitride and bottom oxide. The optimum recipe for each layer of the stack was investigated to minimize the loss of injected charge. The flatband voltage decay of the optimized stack was found to fit a power-law trend, suggesting the dispersive transport of hydrogen atoms with a dispersion parameter of ~0.06–0.07. The optimized stack is projected to maintain a negative charge density of about 3.6 × 10 12 cm –2 or more after 25 years of field operation in an environment such as Arizona, which would be sufficient for field-effect passivation under one-sun illumination. Furthermore, the high stability of the negative injected charge makes the plasma charging technology a safer and lower cost alternative to Al 2 O 3 -passivation technology commonly used to passivate p-type surfaces.

14 SOLAR ENERGY↗

Develop and test fuel cell powered on-site integrated total energy system

Satisfactory performance is reported for the first 12-cell sub-stack of the 5 kW rebuild using improved ABA reactant distribution plates. Construction and test results are described for the first full-sized single-cell test (0.33 m x 0.56 m). Test duration was 450 hours. Plans are outlined for construction and testing of two methanol reformer units based on commercially-available shell-and-tube heat exchangers. A 5 kW-equivalent precursor and a 50 kW-equivalent prototype will be built. Supporting design and single-tube experimental data are presented. Stack support efforts are summarized on corrosion currents of graphite materials and acid-management of single-cell test facilities. Comparative properties are summarized for the two methanol/steam reforming catalysts evauated under Task V (now completed); T2107RS and C70-2RS.

Kaufman, A.↗