Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “friction experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Towards a predictive, physics-based friction model for the dynamics of jointed structures

Bolted connections are ubiquitous in mechanical designs and pose a significant challenge to understanding and predicting the vibration response of assembled structures. The present paper develops a physics-based rough contact model of the frictional interactions within a joint. This model sums over the probable interactions of asperities – defined as locally maximum surface features – to determine the contact forces. Here, the tangential contact forces vary smoothly between sticking and slipping and allow the model to better capture the qualitative trends of experimental amplitude dependent frequency and damping than previous studies. Furthermore, the novel model is generalized to allow for arbitrarily varying normal pressure including potential separation to better represent the interfacial dynamics. This includes developing a new, computationally tractable approximation to the analytical Mindlin partial slip solution for tangential loading of contacting spheres. Further, the results highlight the importance of accurately characterizing the as-built topology of the interface, the plastic behavior of the contacting asperities, the relevant length scale of asperities, and the eccentricity of asperities. A predictive friction coefficient based on plasticity provides a poor match to experiments, so fitting the friction coefficient is also considered. Numerical results are compared to experiments on the Brake-Reuß Beam to assess the predictive potential of the models. While blind predictions over-predict the slip limit, the current model presents a significant improvement in physics-based modeling and highlights areas for ongoing research.

42 ENGINEERING↗

Polyimide film wear: Effect of temperature and atmosphere

Friction and wear experiments conducted on polyimide films bonded to 440C stainless steel disks indicated that a wear transition (from high wear to low wear) accompanied a friction transition (from high friction to low friction). In dry argon or dry air (less than 20 ppm H2O), the transition was found to occur at 40 plus or minus 10 C; when H20 was present in air (10,000 ppm H2O), the transition was found to be elevated to a temperature between 100 and 200 C. Wear rate calculations made at 25, 100, and 200 C indicated that film wear was relatively constant for particular experimental conditions; however, the rate was strongly dependent on temperature and atmosphere.

Fusaro, R. L.↗

Effect of atmosphere and temperature on wear, friction, and transfer of polyimide films

Friction and wear experiments conducted on polyimide films bonded to 440C stainless steel disks indicated that a wear transition (from high wear to low wear) accompanied the friction transition (from high friction to low friction). The transition was found to be atmosphere dependent as well as temperature dependent. Wear rate calculations indicated that at temperatures above the transition, wear could be up to 600 times less than at temperatures below the transition. Transfer to metallic riders was also investigated and found to be considerably different at temperatures above and below the transition.

Fusaro, R. L.↗

Effect of atmosphere and temperature on wear, friction, and transfer of polyimide films

Friction and wear experiments conducted on polyimide films bonded to 440 C stainless steel disks indicated that a wear transition (from high wear to low wear) accompanied the friction transition (from high friction to low friction). The transition was found to be atmospheric dependent as well as temperature dependent. Wear rate calculations indicated that, at temperatures above the transition, wear could be up to 600 times less than at temperatures below the transition. Transfer to metallic riders was also investigated and found to be considerably different at temperatures above and below the transition.

Fusaro, R. L.↗

Compliant wall-turbulent skin-friction reduction research

Previous compliant-wall experiments successful in reducing skin-friction drag probably have had a (unplanned) membrane resonance at a favorable frequency, amplitude, wave shape, length, and speed. The most probable drag reduction mechanism involves a direct coupling between the fluid and the moving wall when the wall natural resonance frequencies are near the fundamental turbulent burst frequency. Local skin-friction reductions of 61% were measured with mylar/PVC plastisol compliant surfaces. These reductions were observed only at certain flow conditions, indicating that changing tunnel total temperature may have altered the substrate dynamic modulus, damping, and coupled mylar tension. Apparently, the coupled membrane/substrate must be excited in compatible narrow-band natural frequency modes. An accelerated effort is required to develop practical durable compliant surfaces optimized for maximum drag reduction. Application of compliant walls to other transportation modes appears feasible with liquid flows offering the greatest skin-friction drag reduction potential.

Fischer, M. C.↗

Tribological properties and thermal stability of various types of polyimide films

Thermal exposure experiments at 315 and 350 C were conducted on seven different types of polyimide films to determine which was the most thermally stable and adherent. The polyimides were ranked according to the rate at which they lost weight and how well they adhere to the metallic substrate. Friction and wear experiments were conducted at 25 C (room temperature) on films bonded to 440C HT stainless steel. Friction, film wear rates, wear mechanisms, and transfer films of the seven films were investigated and compared. The polyimides were found to fall into two groups as far as friction and wear properties were concerned. Group one had lower friction but an order of magnitude higher film wear rate than did group two. The wear mechanism was predominately adhesive, but the size of the wear particles were larger for group one polyimides.

Fusaro, R. L.↗

Tribological properties and thermal stability of various types of polyimide films

Thermal exposure experiments at 315 and 350 C were conducted on seven different types of polyimide films to determine which was the most thermally stable and adherent. The polyimides were ranked according to the rate of which they lost weight and how well they adhered to the metallic substrate. Friction and wear experiments were conducted at 25 C (room temperature) on films bonded to 440C HT stainless steel. Friction, film wear rates, wear mechanisms, and transfer films of the seven films were investigated and compared. The polyimides were found to fall into two groups as far as friction and wear properties were concerned. Group I had lower friction but an order of magnitude higher film wear rate than did group II. The wear mechanism was predominately adhesive, but the size of the wear particles was larger for group I polyimides.

Fusaro, R. L.↗

A unique flight test facility - Description and results

The Dryden Flight Research Facility has developed a unique research facility for conducting aerodynamic and fluid mechanics experiments in flight. A low aspect ratio fin, referred to as the flight test fixture (FTF), is mounted on the underside of the fuselage of an F-104G aircraft. The F-104/FTF facility is described, and the capabilities are discussed. The capabilities include (1) a large Mach number envelope (0.4 to 2.0), including the region through Mach 1.0; (2) the potential ability to test articles larger than those that can be tested in wind tunnels; (3) the large chord Reynolds number envelope (greater than 40 million); and (4) the ability to define small increments in friction drag between two test surfaces. Data are presented from experiments that demonstrate some of the capabilities of the FTF, including the shuttle thermal protection system airload tests, instrument development, and base drag studies. Proposed skin friction experiments and instrument evaluation studies are also discussed.

Meyer, R. R., Jr.↗

A unique flight test facility: Description and results

The Dryden Flight Research Facility has developed a unique research facility for conducting aerodynamic and fluid mechanics experiments in flight. A low aspect ratio fin, referred to as the flight test fixture (FTF), is mounted on the underside of the fuselage of an F-104G aircraft. The F-104G/FTF facility is described, and the capabilities are discussed. The capabilities include (1) a large Mach number envelope (0.4 to 2.0), including the region through Mach 1.0; (2) the potential ability to test articles larger than those that can be tested in wind tunnels; (3) the large chord Reynolds number envelope (greater than 40 million); and (4) the ability to define small increments in friction drag between two test surfaces. Data are presented from experiments that demonstrate some of the capabilities of the FTF, including the shuttle thermal protection system airload tests, instrument development, and base drag studies. Proposed skin friction experiments and instrument evaluation studies are also discussed.

Meyer, R. R., Jr.↗

The atomic nature of polymer-metal interactions in adhesion, friction and wear

Adhesion experiments with polytetra-fluoroethylene (PTFE) and polyimide contacting tungsten indicate that the polymers bond chemically to the clean metal surface. Polymer chain fragments which transfer to the surface of tungsten in field ion microscopy adhesion studies are highly oriented. Auger emission spectroscopy of PTFE transfer films to various metal surfaces indicates that the PTFE is bonded to the metal surface via the carbon atom. With PTFE in sliding contact with different orientations of aluminum, metal orientation is found to influence surfaces in sliding. The lowest friction and least amount of surface damage is detected on the highest atomic density (111) plane. The friction process itself can initiate polymer film formation from simple organic molecules.

Buckley, D. H.↗

Effect of carbon content on friction and wear of cast irons

Friction and wear experiments were conducted with cast irons and wrought steels containing various amounts of carbon in the alloy structure in contact with 52100 steel. Gray cast irons were found to exhibit lower friction and wear characteristics than white cast irons. Further, gray cast iron wear was more sensitive to carbon content than was white. Wear with gray cast iron was linearly related to load, and friction was found to be sensitive to relative humidity and carbon content. The form, in which the carbon is present in the alloy, is more important, as the carbon content and no strong relationship seems to exist between hardness of these ferrous alloys and wear.

Buckley, D. H.↗

Friction and wear of polyethylene oxide polymer having a range of molecular weights

Sliding friction and wear experiments were conducted at light loads (25 to 250 g) with various molecular weights of the polyethylene oxide polymer sliding on itself and iron. Results of the experimental investigation indicate that: (1) the coefficient of friction for the polymer decreases with increasing molecular weight; (2) friction coefficient is higher for the polymer sliding on itself than it is for the polymer sliding on iron; (3) at sufficiently high loads localized surface melting occurs and the friction coefficient is the same for the polymer sliding on itself and iron; (4) fracture cracks develop in the sliding wear track at higher but not lower sliding velocities, reflecting a strain rate sensitivity to crack initiation, and (5) the friction coefficient for the polymer sliding on iron increases with the formation of a polymer film on the iron surface.

Buckley, D. H.↗

Friction and wear of selected metals and of carbons in liquid natural gas

Friction and wear experiments were conducted with hemispherically tipped (4.76-mm radius) rider specimens in sliding contact with a rotating disk submerged in liquid natural gas (LNG). The program included metal combinations and carbon-metal combinations. These experiments revealed that the metal combinations were not lubricated by the LNG. Carbons had much lower wear in LNG than in liquid hydrogen or in liquid nitrogen. (Wear of carbon in liquid hydrogen was 100 times that in LNG.) The friction coefficients obtained in LNG (0.6 for metal-metal and 0.2 for carbon-metal) are similar to those obtained in liquid hydrogen.

Wisander, D. W.↗

Heat transfer, friction, and rheological characteristics of antimisting kerosene

Experiments were performed to determine the skin friction and heat transfer behavior of antimisting kerosene (AMK) in pipe flows. The additive used was FM-9. Based on the results of the experiments, which identify high viscosity and viscoelasticity for AMK, it is recommended that AMK be degraded. Sufficient degradation produces behavior similar to that of jet A.

Matthys, E.↗

Studies of Lubricating Materials in Vacuum

Lubricating materials for use in a vacuum environment have been the subject of a series of experimental investigations. Evaporation properties were evaluated for solid polymeric compositions. Friction and wear studies explored the behavior during sliding contact for series of polymeric compositions, binary alloys containing soft film-forming phases, complex alloys with film-forming materials, and a burnished MoS2 film. Friction and wear experiments were conducted at 10(exp-9)mm Hg with a 3/16-inch-radius-hemisphere rider specimen sliding on the flat surface of a rotating 2-1/2-inch-diameter disk specimen with materials that had low rates of evaporation. The influence of fillers in polytetrafluoroethylene (PTFE) on decomposition during vacuum friction studies was determined with a mass spectrometer. A real advantage in reducing decomposition and improving friction wear properties is gained by adding fillers (e.g., copper) that improve thermal conductivity through the composite materials. A polyimide and an epoxy-MoS2 composition material were found to have better friction and wear properties than PTFE compositions. A series of alloys (cast binary as well as more complex alloys) that contained microinclusions of potential film-forming material was studied. These materials replaced the normal surface oxides as they were worn away on sliding contact. Iron sulfide, nickel oxide, and tin are typical film-forming materials employed and were demonstrated to be effective in inhibiting surface welding and reducing friction. A burnished MoS2 film applied to type 440-C stainless steel in argon with a rotating soft wire brush had good endurance properties but somewhat higher friction than commercially available bonded films. An oil film applied to the burnished MoS2 markedly reduced its endurance life.

WEAR↗

Sliding induced crystallization of metallic glass

Sliding friction and wear experiments, electron microscopy, and diffraction studies were conducted with an Fe67Co18B14Si1 ferrous-base metallic glass in sliding contact with aluminum oxide at room temperature in air. The results indicate that the amorphous alloy can be crystallized during the sliding process. Crystallization of the wear surface causes high friction. Plastic flow occurred on the amorphous alloy with sliding, and the flow film of the alloy transferred to the aluminum oxide surface. Two distinct types of wear debris were observed as a result of sliding: an alloy wear debris, and powdery and whiskery oxide debris. Generation of oxide wear debris particles on an alloy can cause transitions in friction behavior.

Miyoshi, K.↗

Surface effects of corrosive media on hardness, friction, and wear of materials

Hardness, friction, and wear experiments were conducted with magnesium oxide exposed to various corrosive media and also with elemental iron and nickel exposed to water and NaOH. Chlorides such as MgCl2 and sodium containing films were formed on cleaved magnesium oxide surfaces. The MgCl2 films softened the magnesium oxide surfaces and caused high friction and great deformation. Hardness was strongly influenced by the pH value of the HCl-containing solution. The lower the pH, the lower the microhardness. Neither the pH value of nor the immersion time in NaOH containing, NaCl containing, and HNO3 containing solutions influenced the microhardness of magnesium oxide. NaOH formed a protective and low friction film on iron surfaces. The coefficient of friction and the wear for iron were low at concentrations of NaOH higher than 0.01 N. An increase in NaOH concentration resulted in a decrease in the concentration of ferric oxide on the iron surface. It took less NaOH to form a protective, low friction film on nickel than on iron.

Miyoshi, K.↗

Surface effects of corrosive media on hardness, friction, and wear of materials

Hardness, friction, and wear experiments were conducted with magnesium oxide exposed to various corrosive media and also with elemental iron and nickel exposed to water and NaOH. Chlorides such as MgCl2 and sodium containing films were formed on cleaved magnesium oxide surfaces. The MgCl2 films softened the magnesium oxide surfaces and caused high friction and great deformation. Hardness was strongly influenced by the pH value of the HCl-containing solution. The lower the pH, the lower the microhardness. Neither the pH value of nor the immersion time in NaOH containing, NaCl containing, and HNO3 containing solutions influenced the microhardness of magnesium oxide. NaOH formed a protective and low friction film on iron surfaces. The coefficient of friction and the wear for iron were low at concentrations of NaOH higher than 0.01 N. An increase in NaOH concentration resulted in a decrease in the concentration of ferric oxide on the iron surface. It took less NaOH to form a protective, low friction film on nickel than on iron.

Miyoshi, K.↗