Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency ratio”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Nonlinear modeling of the scaling law for the m/n = 3/2 error field penetration threshold

The scaling law for the m/n=3/2 error field (EF) penetration threshold is predicted numerically based on nonlinear single-fluid and two-fluid modeling using the TM1 code. The simulated penetration threshold of radial magnetic field b r at the plasma edge is scaled to the electron density n e , temperature T e , viscous time τ μ , toroidal field B t and the natural frequency ω in the form of b r /B t ∝n e αn T e αT τ μ αμ B t αB ω αω by scanning these parameters separately. Here, α n , α T , α μ , α B and α ω are the scaling coefficients on n e , T e , τ μ , B t and ω, respectively. Single-fluid modeling shows that the 3/2 EF threshold scales as b r /B t ∝n e 0.56 T e 0.6 τ μ -0.59 B t -1.15 ω, which is similar with the analytical scaling law in both the Rutherford and visco-resistive regimes. Yet, two-fluid modeling shows that the scaling law differs significantly in particular regarding the dependence on plasma rotation. In detail, the scaling coefficient α n on density decreases from 0.67 to 0.56 and α T on temperature decreases from 0.67 to 0.32, while α μ on viscous time is around -0.45 and α B on toroidal field decreases slightly from -1.15 to -1, when the ratio |ω E /ω *e | between plasma rotation frequency ω E and diamagnetic drift frequency ω *e varies from 0 to 10. Scans of the plasma rotation reveals that the penetration threshold linearly depends on the perpendicular rotation frequency (or natural frequency) ω ⊥e =ω E +ω *e , and there is a minimum in the required field amplitude when ω ⊥e 0. In addition, the enduring mystery of non-zero penetration threshold at zero plasma natural frequency in EF experiments is resolved by two-fluid simulations. We report that the very small island and smooth bifurcation in EF penetration near zero frequency is hard to detect in the experiment, leading to a finite penetration threshold within the capability of the experimental measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In situ x-ray imaging to understand subsurface behavior during continuous wave laser drilling

A limited understanding regarding the underlying dynamics and mechanisms of material removal during continuous wave laser drilling has presented significant challenges in achieving precision and process control. Here, to address this, we employed high-fidelity, in situ synchrotron x-ray imaging to reveal previously unknown material behaviors during continuous wave laser drilling with power modulation. Our findings highlight that high-aspect ratio drill holes are achieved when the laser modulation frequency falls within the range of 8–12 kHz, provided that the laser average power and modulation amplitude levels meet the specified limits. Under these conditions, we identified a material removal mechanism driven by incremental accumulation of recoil pressure that gradually pushes material upward from deep within the substrate to the surface. This mechanism manifested as a low-frequency fluctuation in the vapor depression depth, resulting in periodic instances of material ejection. Furthermore, our study underscores that rapid expansion of the melt pool and the widening of the drill hole opening can impede effective material removal by redirecting energy from material ejection to increasing the melt pool size. This investigation contributes essential insights into the subsurface dynamics involved in the drilling of high-aspect ratio holes, furthering our fundamental understanding of this intricate process.

47 OTHER INSTRUMENTATION↗

Single-element balanced detector giving 65 dB CMRR at 30 MHz

We present a simple design for a single-element balanced detector (BD) that utilizes optical fibers in the sensing and reference channels with path length differences set to detect the differential signal at a desired frequency. With this approach, we easily achieve a common-mode rejection ratio of 65 dB, corresponding to the shot-noise limit of our setup. The CMRR demonstration is made in the MHz frequency range but could be extended to the kHz or GHz range. Using a single detector, the BD achieves stable CMRR over extended periods and does not require careful matching of detectors and amplification electronics. We demonstrate the single-element balanced detector design using the optical Kerr effect induced by a 30 MHz pulsed laser, showing a significant improvement over similar experiments using a commercial balanced detector.

Badilla-Nunez, Kelly [Georgia Institute of Technol↗

Equivalence Ratio Scans in a Rotating Detonation Engine

Published data for run times exceeding a few seconds in rotating detonation engines (RDEs) is rare, but long duration tests are necessary to understand both transient and persistent phenomena in RDE operation. Previous work has noted different detonation wave modes at different equivalence ratios. In the current study, multiple long-duration runs with constant air flow rate and variable equivalence ratio are conducted in a hydrogen-fueled, water-cooled RDE. Analysis of the capillary tube averaged pressure (CTAP) data reveals a strong correlation with equivalence ratio as well as a small time dependency due to transient thermal processes. Ion probe measurements are used to analyze detonation wave frequencies and modes, both of which are strongly dependent on the equivalence ratio. Mode transitions are observed to occur consistently as the equivalence ratio is traversed between 0.55 and 0.60. These transitions are also found to be a function of the direction of changing equivalence ratio (ascending or descending) and time.

Boyette, Wesley R.↗

Equivalence Ratio Scans in a Rotating Detonation Engine

Published data for run times exceeding a few seconds in rotating detonation engines (RDEs) is rare, but long duration tests are necessary to understand both transient and persistent phenomena in RDE operation. Previous work has noted different detonation wave modes at different equivalence ratios. In the current study, multiple long-duration runs with constant air flow rate and variable equivalence ratio are conducted in a hydrogen-fueled, water-cooled RDE. Analysis of the capillary tube averaged pressure (CTAP) data reveals a strong correlation with equivalence ratio as well as a small time dependency due to transient thermal processes. Ion probe measurements are used to analyze detonation wave frequencies and modes, both of which are strongly dependent on the equivalence ratio. Mode transitions are observed to occur consistently as the equivalence ratio is traversed between 0.55 and 0.60. These transitions are also found to be a function of the direction of changing equivalence ratio (ascending or descending) and time.

Boyette, Wesley R.↗

Quantitative Comparisons of Image Quality for Flash X-Ray Detectors

Due to X-rays’ ability to penetrate materials, flash X-ray radiography can be used for high-speed measurements where direct optical access is not possible. Choice of detector has a pronounced impact on resulting image quality. Four different detector systems were evaluated with a 450kVp flash source to quantitatively compare image quality metrics. The scintillating digital detector had less image noise than the three different storage phosphor computed radiography detectors across all transmission levels, but lacked the spatial resolution of the computed radiography detectors. For the screens tested here, the HPX-DR digital system had the highest signal to noise ratio of 68.24 and contrast to noise ratio of 35.53, but had the lowest spatial resolution, resolving 2.5 line pairs per millimeter at 1.78% contrast. At a value of 37.59, the Flex GP imaging plate had a signal to noise value above its storage phosphor counterparts under a 450kVp flash source. For radiographic setups typically used for dynamic experiments, the Flex XL Blue and Flex HR detectors had signal to noise ratios of 18.44 and 26.56 respectively. The highest resolved spatial frequencies of the Flex GP, Flex XL Blue, and Flex HR with the flash source are 3.85, 5.00, and 3.85 line pairs per millimeter, respectively. In conclusion, the Flex GP detector had the best combination of signal to noise ratio, contrast to noise ratio, and spatial resolution under a flash source.

computed radiography↗

Gravo-aeroelastic scaling of a 13-MW downwind rotor for 20% scale blades

A 105-m, 13-MW two-bladed downwind Segmented Ultralight Morphing Rotor (SUMR-13) blade was gravo-aeroelastically scaled by 20% to a 20.87-m-long demonstrator blade and confirmed through structural ground testing. The subscale model was achieved through geometric scaling and by aeroelastic scaling principles based on operational flapwise deflections combined with rotational and structural frequencies while retaining the turbine tip-speed ratio. In particular, the subscale demonstrator was designed to replicate, as closely as possible, the nondimensional geometry, the ratio of centrifugal to gravitational moments, the tip-speed ratio, and the nondimensional rotation rate. The intent for this demonstrator was to achieve the same nondimensional flapwise blade deflections and dynamics of the full-scale 13-MW rotor. The manufactured SUMR-D blade resulted in less than half of the mass of the conventional two-bladed Controls Advanced Research Turbine (CART2) rotor blade based on scaling and a lower power rating, though with some differences in mass and stiffness from the ideal scaled-down design to meet safety requirements at the test site. To achieve proper scaling, operational pitch control set points were altered to account for the differences by evaluating simulated operation of both the SUMR-13 and SUMR-D rotors. Structural testing of the SUMR-D blade investigated the response to well-defined flapwise loads and indicated that the subscale blade had the appropriate elastic properties needed for both scaling and for safe operational field testing.

17 WIND ENERGY↗

Servo-aero-gravo-elastic (SAGE) scaling and its application to a 13-MW downwind turbine

Reduced scale wind turbines can be extremely cost-effective to test new rotor concepts since prototype costs are heavily dependent on the rotor diameter. Ideally, the scaled model would have the same non-dimensional deflections, dynamics, and control behavior as the full-scale model. This would provide a high-fidelity demonstration of the full-scale performance, which is ideal if the full-scale turbine has significant aeroelastic interactions. To this end, servo-aero-gravo-elastic (SAGE) scaling is developed and applied to a 13-MW turbine that is scaled to a 20% scale model. The scaling preserves the tip-speed ratio, the rotor speed normalized by the flapping frequency, and the tip deflections normalized by the blade length. In addition, the controller employs the same control structure (gain-scheduled pitch control and variable speed torque control) and is scaled dynamically (e.g., matching non-dimensional time constant of the pitch angle, etc.). Furthermore, the thrust, gravity, and centrifugal moments are scaled such that the load angles are preserved as a function of a non-dimensional wind speed. However, the environmental scaling must consider differences in Reynolds number (since this parameter cannot be held constant) and subsequent changes in the axial induction factor. While the presented results showcase these differences during operational conditions, the non-dimensional tip deflections remain comparable through all wind speed ranges, indicating the viability of the SAGE scaling method in matching full-scale aeroelastic responses.

Kaminski, Meghan (ORCID:0000000322334784)↗

Curious cross-field transport effects in multi-ion, magnetized plasma

In contrast to single-ion plasma, multiple-ion-species plasma exhibits new, curious, and large transport effects. On short timescales, where ions exchange momentum, magnetized multi-ion plasma behaves as a most unusual substance, compressible across field lines in number density but incompressible in charge density. It takes 40 times longer for electrons to participate. In this ion–ion cross-field transport regime, we identified the charge-incompressibility heat pump effect, transferring heat both spatially and between species. Curiously, the direction of impurity transport strongly depends on plasma magnetization, characterized by the ratio of light ion gyrofrequency to the collision frequency between light and heavy ion species. The expulsion of heavy ion impurities from a hotspot occurs sufficiently quickly to be observable on MagLIF, so long as plasma becomes sufficiently collisionally magnetized under implosion. Even more curious, multi-ion transport changes its nature in partially ionized plasma, where ions occupy different charge states. In this regime, we identify a partial-ionization deconfinement effect. The combination of cross-field transport, ionization, and recombination leads to a net ion charge moving across magnetic field lines on the ion–ion transport timescale as opposed to the electron–ion transport timescale. Cross-field transport effects in multi-ion plasma are important in a number of applications, including nuclear fusion and plasma mass filters.

Mlodik, M. E. (ORCID:0000000343003941)↗

Planar multifrequency mid-IR microwave-pumped lasers

The characteristics of planar repetitively pulsed diffusion-cooled HF, DF, HF – DF, Xe, and HF – DF – Xe(Kr) lasers pumped by a microwave discharge (2.45 GHz) are studied depending on the pump pulse duration (10 – 40 μs) and repletion rate (50 – 400 Hz), as well as on the composition and pressure of the working gas mixture (30 – 200 Torr) at low (to 0.6 L s{sup −1}) gas flow rates. It is demonstrated for the first time that a HF – DF – Xe gas-discharge laser may simultaneously operate as a HF – DF chemical molecular laser and a recombination laser based on xenon atom transitions and generate broadband (octave) radiation in the range 2.0 – 4.2 μm with an average output power of 43 mW and an efficiency of 0.9 %. With substitution of xenon for krypton, lasing in a HF – DF – Kr laser is obtained at wavelengths of 2.52 – 4.15 μm. Lasing in a HF – DF laser was achieved simultaneously in two spectral regions (2.7 – 2.9 and 3.6 – 4.2 μm) with an output power of ∼50 mW. It is found that a decrease in the pump pulse duration with a simultaneous increase in the pulse repletion rate for retaining the average energy deposition leads to an increase in the average output power and efficiency of the laser. At low pulse repetition rates (50 – 100 Hz) and a low gas mixture flow rate, helium buffer gas can be effectively substituted for neon. Operation of the Xe laser was achieved in the spectral range 2.03 – 3.65 μm with an average output power of 580 Mw at a pump pulse duration of 20 μs, a pulse repetition rate to 10 kHz, and a maximum efficiency of 55 %. The obtained experimental results demonstrate the possibility of creating broadband HF – DF – Xe lasers emitting in the frequency range 2 – 4 μm with a desired ratio of intensities in different spectral ranges. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Searching for Gravitational Waves from Cosmological Phase Transitions with the NANOGrav 12.5-Year Dataset

We search for a first-order phase transition gravitational wave signal in 45 pulsars from the NANOGrav 12.5-year dataset. We find that the data can be modeled in terms of a strong first order phase transition taking place at temperatures below the electroweak scale. However, we do not observe any strong preference for a phase-transition interpretation of the signal over the standard astrophysical interpretation in terms of supermassive black hole mergers; but we expect to gain additional discriminating power with future datasets, improving the signal to noise ratio and extending the sensitivity window to lower frequencies. An interesting open question is how well gravitational wave observatories could separate such signals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A 194nW Energy-Performance-Aware loT SoC Employing a 5.2nW 92.6% Peak Efficiency Power Management Unit for System Performance Scaling, Fast DVFS and Energy Minimization

A self-powered IoT system-on-chip (SoC) reduces power to sub-μw and employs multiple power-management techniques to trade-off ultra-low power (ULP), higher performance, smaller energy harvester footprint, and longer operating lifetime. Minimum Energy Point Tracking (MEPT) [1]–[4] keeps an SoC operating at the minimum energy point (MEP) to enhance system lifetime. Previous sample-and-hold MEPT schemes need frequent voltage comparisons and a high-frequency clock that increases power [2]. Current-ratio-based MEPT relies on specialized CMOS technology for body-bias tuning [3]. A switched-capacitor-based MEPT can achieve energy minimization at a targeted performance [4], but it uses a 30MHz clock witμW power consumption and low power efficiency. For ULP IoT applications, SoCs need to have ultra-low quiescent power, high efficiency for energy delivery, performance scaling based on available energy, and energy minimization to increase system lifetime. In this work, we propose an ULP IoT SoC with a triple-mode power management unit (PMU) that integrates energy-performance scaling, event-driven fast DVFS, and MEPT features to improve the system energy efficiency, as shown in Fig. 13.8.1. This work achieves a minimum 194nW power consumption for the SoC and 5.2nW quiescent power for the PMU with a 92.6% peak efficiency and >10 4 dynamic range. The timing waveform in Fig. 13.8.1 (bottom), demonstrates the transition of the three modes including energy aware (EA), performance aware (PA), and MEPT based on event priority and input voltage level which reflects the energy availability. As such, the system energy consumption and performance could be well-balanced based on both the input and output conditions.

self-powered IoT system-on-chip (SoC)↗

Using a 1D Radially Symmetric Coda Envelope Model for Robust Moment Magnitude ( M w ) Estimation in Iraq’s Tectonically Diverse Zones

Robust estimation of moment magnitude (M w ) can be challenging for Iraq due to the strong lateral heterogeneity across diverse tectonic zones. We aim to improve moment magnitude estimation by investigating the reliability of using a 1D coda envelope model in diverse tectonic zones of different lateral effects and offer a way forward for reliable estimates of M w for small events that are difficult to waveform model. Iraq comprises two main tectonic zones: (1) the Outer platform, consisting of the northwestern Zagros fold-thrust belt and the Mesopotamian foredeep, and (2) the Inner Arabian platform which is overlain by the Iraqi desert. A simple 1D coda envelope model was used because coda waves have a low sensitivity to the source and path heterogeneity. Three separate coda calibrations were conducted to investigate the robustness of a single 1D calibration to fit the country: Whole-region calibration, Zagros calibration, and Mesopotamia calibration. In the whole-region calibration, we used stations from both the Zagros and Mesopotamia zones. In the two other calibration models, we used only stations that were in those particular zones. Ground-truth reference spectra derived from the coda spectral ratio method were used to constrain high-frequency site terms. There was no drastic difference when comparing the moment magnitudes calculated from the waveform modeling and the three calibration models. The results show that the 1D coda envelope model is a reliable method even for a region with diverse tectonic zones. Therefore, we recommend using the whole-region calibration model for moment magnitude estimation that provides more complete path coverage and avoids biases introduced by path correction failures. The proposed calibration is a fundamental step in updating the comprehensive earthquake catalog and probabilistic seismic hazard assessments for Iraq.

58 GEOSCIENCES↗

Lossy Compression: An Online Multi-Stage Technology for High-Fidelity Synchro- Waveform Measurements

Effective real-time monitoring and analysis of distributed grids necessitate the use of synchro-waveform measurements, which capture almost all high-frequency disturbances and transient phenomena. However, due to limitations in high-speed measurements and network bandwidth, it is challenging to transfer all high-fidelity synchro-waveforms losslessly and successfully. To cope with these challenges, a hybrid-based online multi-stage compression algorithm is proposed to significantly improve the compression efficiency for synchro-waveform measurements. Initially, the multiple discrete Wavelet transformation is deployed to deconstruct the waveform components. The delta encoding is further developed to decrease the magnitude. In conjunction with the Lempel-Ziv-Markov chain, the hybrid compression algorithm is implemented to achieve real-time compression for the synchro-waveform measurements. Moreover, an innovative error index that synergizes the time and frequency domain error and correlation is formulated to evaluate the waveform distortion. By integrating compression ratio, suitable parameters can be optimally selected. Finally, the simulation, laboratory experiments, as well as field tests across a spectrum of sampling frequencies and time intervals are conducted to substantiate the efficacy of the proposed method. Here, the outcomes demonstrated that a compression ratio of approximately 15.5 and 17.83 can be reached for 0.5 s and 1 s data under both offline and online scenarios, which equates to a substantial 93.5% to 94.39% reduction in data storage requirements.

High-fidelity synchro-waveform measurements↗

Simulating High-Frequency Seismograms in Realistic Earth Models to Better Understand Source Discrimination Based on Differential Magnitudes ( M L− M c)

Discriminating low-yield underground nuclear explosions from small earthquakes is a key task in monitoring nuclear test ban treaties. P/S amplitude ratios have been an effective discriminant for moderate-sized events recorded at regional distances, but it is unclear if they are as effective in discriminating small seismic events recorded at local distances (<150 km). The difference between local magnitude (M L ) and coda duration magnitude (M c ) has been proposed as a new discriminant that may complement P/S amplitude ratios at local distances. Here, in this work, we calculate high-frequency (up to ∼4 Hz) synthetic seismograms at epicentral distances of 0–30 km in realistic models of the Salt Lake basin (Utah, United States) to better understand how variations in source type and depth affect M L −M c values. The Earth models incorporate simplified 1D and deterministic 3D structures, small-wavelength stochastic velocity perturbations, and surface topography. Coda waves are enhanced for the more complicated models compared to the base 1D model, but still underpredict observed durations by about a factor of two, which results in overprediction of amplitude to duration ratios (i.e., M L −M c values) for a near-surface explosion and a 7 km deep earthquake. For both source types, the predicted M L and M c values decrease as source depth increases, and M L −M c shows only minor variation with depth; however, M L −M c is on average ∼0.5 units smaller for explosions than earthquakes. This finding may imply that M L −M c has sensitivity to source type, in addition to being a depth discriminant, but more modeling is needed given the limitations of the current study. Future modeling should incorporate higher-frequency (≳5 Hz) simulations over a larger distance range (0–150 km), where M L and M c are commonly measured, while honoring low shear velocities (<300 m/s) near the surface and sampling a wider range of earthquake and explosion source mechanisms.

Hutchings, Sean J. [Univ. of Utah, Salt Lake City,↗

Design and analysis of a segmented blade for a 50 MW wind turbine rotor

Extreme-size wind turbines face logistical challenges due to their sheer size. A solution, segmentation, is examined for an extreme-scale 50 MW wind turbine with 250 m blades using a systematic approach. Segmentation poses challenges regarding minimizing joint mass, transferring loads between segments and logistics. We investigate the feasibility of segmenting a 250 m blade by developing design methods and analyzing the impact of segmentation on the blade mass and blade frequencies. This investigation considers various variables such as joint types (bolted and bonded), adhesive materials, joint locations, number of joints and taper ratios (ply dropping). Segmentation increases blade mass by 4.1%–62% with bolted joints and by 0.4%–3.6% with bonded joints for taper ratios up to 1:10. Cases with large mass growth significantly reduce blade frequencies potentially challenging the control design. We show that segmentation of an extreme-scale blade is possible but mass reduction is necessary to improve its feasibility.

Escalera Mendoza, Alejandra S.↗

Strain-rate hardening enhances fatigue resistance of AlSi10Mg alloy at 350°C

The high cycle fatigue behavior of laser powder bed fusion processed AlSi10Mg has been investigated at 350 °C (T/T m ∼ 0.7). The alloy exhibited a fatigue strength of 30 MPa defined by runout after 10 7 cycles at a conventional loading frequency of 20 Hz, corresponding to a notable fatigue strength to ultimate tensile strength ratio of 0.73. The surprising fatigue resistance was attributed to the strain-rate hardening effect at high fatigue loading frequency relative to tensile loading rates at 350 °C. The strain-rate hardening effect was validated by performing ultrasonic fatigue tests (20 kHz loading frequency) with three orders of magnitude higher strain-rates than those at conventional loading frequency. The higher strain-rates in ultrasonic fatigue increased the magnitude of strain-rate hardening resulting in longer AlSi10Mg fatigue lives compared to fatigue at conventional frequency, thus confirming the strain-rate hardening effect. The fatigue crack initiation mechanism was strain-rate dependent. Post-mortem microstructural examination revealed intergranular cavitation inside clusters of fine equiaxed grains. The cavities interlinked with each other to initiate near-surface fatigue cracks at conventional frequency. Cavitation occurred to a lesser extent at the ultrasonic frequency. As a result, fatigue cracks initiated at pre-existing processing defects near the surface in ultrasonic fatigue samples. Finally, this investigation underscores the role of fine grain clusters in promoting high-temperature fatigue crack initiation and indicates a possible trade-off between printability via grain refinement and high-temperature fatigue resistance of additively manufactured alloys.

Additive manufacturing↗

Measurement of the muon anomalous precession frequency in runs 2 \& 3 of the Muon $g-2$ Experiment at Fermilab

This dissertation presents a measurement of the muon anomalous precession frequency for the Runs 2 \& 3 data of the E989 Muon $g-2$ Experiment at Fermilab. The muon anomalous precession frequency is one of two key inputs, the other being the magnetic field, used to precisely determine the muon magnetic anomaly, $a_{\mu}$. In April 2021, the E989 collaboration reported its first measurement of $a_{\mu}$ to an unprecedented precision of 460 parts-per-billion (ppb). This result is in agreement with the previous measurement performed by the E821 collaboration at Brookhaven National Laboratory, and the combined experimental value is in tension with the Standard Model prediction at 4.2$\sigma$, a possible hint of new physics. The first result from E989 was based on the Run-1 data, which was collected in 2018 and comprises 6\% of the experiment’s target statistics; the Run-1 result was statistics-limited. The Runs 2 \& 3 data were collected in 2019-2020 and constitute a four-fold increase i n statistics compared to Run-1 and consequently, a factor of two reduction in the measurement’s statistical uncertainty. This reduced statistical uncertainty, as well as continued understanding of systematic effects, will result in an even more precise measurement of $a_{\mu}$ and will help clarify the observed tension between theory and experiment. The precession frequency analysis presented in this dissertation includes a number of improvements compared to Boston University's Run-1 analysis: the implementation of a more robust pileup-subtraction procedure, the implementation of a kernel ratio method, the adoption of the statistically optimal asymmetry-weighted method, and investigations that led to an improved understanding of an outstanding residual slow effect. This dissertation motivates a measurement of the muon magnetic anomaly, describes the experimental principle, gives an overview of the E989 experiment, and presents a precession frequency analysis with full systematic unc ertainty evaluation for the Runs 2 \& 3 data. The combined precession frequency measurement, using the ratio asymmetry-weighted method, has a statistical uncertainty of 201 ppb and a systematic uncertainty of 25 ppb, constituting the most precise determination of the muon anomalous precision frequency to date.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗