Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “framing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Gravitational memory and Ward identities in the local detector frame

Gravitational memory, which describes the permanent shift in the strain after the passage of gravitational waves, is directly related to Weinberg’s soft graviton theorems and the Bondi-Metzner-Sachs (BMS) symmetry group of asymptotically flat space-times. In this work, we provide an equivalent description of the phenomenon in local coordinates around gravitational wave detectors, such as transverse-traceless (TT) gauge. We show that gravitational memory is encoded in large residual diffeomorphisms in this gauge, which include time-dependent anisotropic spatial rescalings, and prove their equivalence to BMS transformations when translated to TT gauge. We then derive the associated Ward identities and associated soft theorems, for both scattering amplitudes and equal-time (in-in) correlation functions, and explicitly check their validity for planar gravitational waves. Furthermore, the in-in identities are recognized as the flat-space analog of the well-known inflationary consistency relations.

General relativity↗

The Pixel Anomaly Detection Tool : a user-friendly GUI for classifying detector frames using machine-learning approaches

Data collection at X-ray free electron lasers has particular experimental challenges, such as continuous sample delivery or the use of novel ultrafast high-dynamic-range gain-switching X-ray detectors. This can result in a multitude of data artefacts, which can be detrimental to accurately determining structure-factor amplitudes for serial crystallography or single-particle imaging experiments. Here, a new data-classification tool is reported that offers a variety of machine-learning algorithms to sort data trained either on manual data sorting by the user or by profile fitting the intensity distribution on the detector based on the experiment. This is integrated into an easy-to-use graphical user interface, specifically designed to support the detectors, file formats and software available at most X-ray free electron laser facilities. The highly modular design makes the tool easily expandable to comply with other X-ray sources and detectors, and the supervised learning approach enables even the novice user to sort data containing unwanted artefacts or perform routine data-analysis tasks such as hit finding during an experiment, without needing to write code.

47 OTHER INSTRUMENTATION↗

Granular Flow in Novel Octet Shape–Based Lattice Frame Material

Moving packed-bed heat exchangers in concentrated solar power (CSP) plants involves heat transfer between heated falling particles and supercritical carbon dioxide. The overall effective thermal conductivity of the moving packed bed and particle-side channel contact resistances are still the bottlenecks in achieving the desirable thermal transport levels. To this end, a novel moving packed bed heat exchanger consisting of an Octet lattice packed between the walls of the particle-side channel is proposed in this study. Granular flow analysis in Octet lattice moving packed bed heat exchanger (OLHX) was conducted through experiments and discrete element method (DEM)-based numerical simulations. The experimental images clearly demonstrated stagnation regions upstream of lattice fibers, void regions downstream of the fiber junctions, and wavy-type unobstructed flow on the lateral sides of the fibers. DEM simulations were successful in capturing all these critical flow phenomena. Larger flow velocities were observed on the lateral sides of the fibers in the simulations. Also, when the particles in the silo were emptied, the final images showed an accumulation of particles on the inter-fiber as well as fiber–channel wall junctions. Moreover, the fiber connections resulted in some regions devoid of particle contact on the channel endwall, which means that these regions would suffer from poor thermal exchange. Finally, the overall mass flowrate increased with increasing porosity for a fixed particle diameter.

14 SOLAR ENERGY↗

Enhanced phagocytosis and complement-mediated killing of Mannheimia haemolytica serotype 1 following in-frame CMP-sialic acid synthetase ( neuA ) gene deletion

ABSTRACT Mannheimia haemolyticais the most significant bacterial pathogen associated with the bovine respiratory disease complex. Although sialic acid is a known virulence factor in other members of Pasteurellaceae, such asHistophilus somniandPasteurella multocida, the significance of sialic acid to the virulence ofM. haemolyticais currently unknown. Therefore, the role of sialic acid as a virulence determinant ofM. haemolyticawas investigated by constructing an in-frameneuA[CMP-N-acetylneuraminic acid (Neu5Ac/sialic) synthetase] mutant, which was shown by high-performance anion exchange chromatographic analysis (HPAEC) to be devoid of sialic acid on the lipopolysaccharide (LPS). Both theneuAmutant and wild-type parent strains exhibited similar growth rates in the growth curve assay. Real-time qPCR and ELISA evaluation showed no differences in proinflammatory cytokine expressions (IL-1β, IL-6, and IL-8) between theneuAmutant and parent strain when peripheral blood mononuclear cells were incubated with LPS. Interestingly, theneuAmutant was three to four logs more sensitive to a whole-blood bacterial killing assay than the parent strain. Similar results were also observed in plasma and serum bacterial killing assays. Flow cytometry analyses showed higher uptake ofneuAmutant by phagocytes, compared to the parent strain, in the whole-blood phagocytosis assay; however, no difference in reactive oxygen species production in neutrophils or monocytes was detected for either strain. Taken together, these results indicate that sialylation ofM. haemolyticaLPS plays a vital role in reducing complement-mediated and phagocytic killing. IMPORTANCE The Gram-negative coccobacillusMannheimia haemolyticais a natural inhabitant of the upper respiratory tract in ruminants and the most common bacterial agent involved in bovine respiratory disease complex development. Key virulence factors harbored byM. haemolyticaare leukotoxin, lipopolysaccharide, capsule, adhesins, and neuraminidase which are involved in evading innate and adaptive immune responses. In this study, we have shown that CMP-sialic acid synthetase (neuA) is necessary for the incorporation of sialic acid onto the membrane, and inactivation ofneuAresults in increased phagocytosis and complement-mediated killing ofM. haemolytica,thus demonstrating that sialylation contributes to the virulence ofM. haemolytica.

Microbiology↗

Single-frame far-field diffractive imaging with randomized illumination

Contains a transmission ptychography dataset collected from a chrome on glass Siemens star under optical illumination. The probe is generated by a randomized zone plate under illumination from a spatially filtered green laser. A single diffraction pattern was removed from the dataset and reported in a separate cxi file. In addition, a single exposure collected after manually defocusing the probe is reported. The ptychography dataset is used for calibration of the probe function, and the remaining diffraction patterns can be reconstructed via randomized probe imaging.

Ptychography, Randomized Probe Imaging↗

Single-frame far-field diffractive imaging with randomized illumination

Contains two transmission ptychography datasets, one collected from a Siemens star, and the second from an Fe/Gd multilayer. Both samples are under illumination from the same randomized zone plate. Each dataset has a single diffraction pattern removed, and these patterns are reported in a separate cxi file. Either ptychography dataset can be used for calibration of the probe function, and the remaining diffraction patterns can be reconstructed via randomized probe imaging.

BESSY II↗

Multi-frame, ultrafast, x-ray microscope for imaging shockwave dynamics

Inertial confinement fusion (ICF) holds increasing promise as a potential source of abundant, clean energy, but has been impeded by defects such as micro-voids in the ablator layer of the fuel capsules. It is critical to understand how these micro-voids interact with the laser-driven shock waves that compress the fuel pellet. At the Matter in Extreme Conditions (MEC) instrument at the Linac Coherent Light Source (LCLS), we utilized an x-ray pulse train with ns separation, an x-ray microscope, and an ultrafast x-ray imaging (UXI) detector to image shock wave interactions with micro-voids. To minimize the high- and low-frequency variations of the captured images, we incorporated principal component analysis (PCA) and image alignment for flat-field correction. After applying these techniques we generated phase and attenuation maps from a 2D hydrodynamic radiation code (xRAGE), which were used to simulate XPCI images that we qualitatively compare with experimental images, providing a one-to-one comparison for benchmarking material performance. Moreover, we implement a transport-of-intensity (TIE) based method to obtain the average projected mass density (areal density) of our experimental images, yielding insight into how defect-bearing ablator materials alter microstructural feature evolution, material compression, and shock wave propagation on ICF-relevant time scales.

47 OTHER INSTRUMENTATION↗

Test Shipment of the PIP-II 650 MHz Transport Frame Between FNAL to STFC-UKRI

The PIP-II Project will receive fully assembled cryomodules from CEA and STFC-UKRI as in-kind contributions. Damage to these cryomodules during transport is understood to be a significant risk to the project, so an extensive testing and validation program is in process to mitigate this risk. The centerpiece of this effort is the eventual shipment from FNAL to STFC-UKRI and back of a prototype HB650 cryomodule with cold testing before and after shipment to verify no functionality changes from shipment. Most recently, a test shipment to the UK and back using a cryomodule analog was completed using realistic logistics, handling, instrumentation, and planning. The process of executing this test shipment, lessons learned, and plan moving forward will be presented here.

43 PARTICLE ACCELERATORS↗

Rapid Fabrication of High Frame Rate Multichannel FTIR Spectrometers

Spectrally resolved signals in the short- to mid-wave infrared (SWIR/MWIR) bands at high-temporal resolution are critical for many national security remote sensing missions. Currently available off the shelf technology can achieve either high temporal resolution or high spectral resolution, but rugged instruments that can achieve both simultaneously remain mostly in the realm of one-off R&D projects. This report documents efforts to demonstrate a new technique for designing and building high resolution, high framerate multichannel FTIR (MC-FTIR) spectrometers that operate in the SWIR/MWIR bands. The core optical element in a MC-FTIR spectrometer is an array of statically-tuned lamellar grating interferometers (LGI). In the original MC-FTIR work these arrays were fabricated using a synchrotron x-ray lithography method. We proposed to instead fabricate these LGI arrays using multiphoton lithography (MPL), a 3D printing technique that can fabricate meso-scale structures with sub-micron precision. Although we were able to fabricate LGI arrays of sufficient size using MPL, the realized optical surfaces had unsuitably high optical form errors, precluding their use in a fieldable instrument. Further advancement in MPL technology may eventually enable fabrication of interferometer-grade LGI arrays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗