Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fluorescence imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Lattice light-sheet microscopy allows for super-resolution imaging of receptors in leaf tissue

Plant leaf tissues are difficult to image via fluorescent microscopy, largely due to the presence of chlorophyll and other pigments that provide large background fluorescence. An advantage of Lattice Light-Sheet microscopy is its use of Bessel beams that illuminate a thin focal region of interest for microscopy, allowing for the excitation of fluorescent molecules within this region without surrounding chlorophyll-like objects outside of the region of interest. Here, we apply STORM Super-resolution techniques to observe Receptor-Like Kinases in Arabidopsis thaliana leaf cells. By applying this technique with the Lattice Light-Sheet, we can localize immune response proteins in sub-100 nm length scales and reconstruct three-dimensional locations of proteins within individual leaf cells. Using this technique, we observed the effect of the elicitors ATP and flg22, where we observed a significant degree of internalization of cognate receptors P2K1 and FLS2. We were also able to similarly observe differences in colocalization due to stimulation with these elicitors, where we observe proteins on the membrane becoming less colocalized as a result of stimulation, suggesting an immune response mechanism involving receptors internalizing via pathways distinct to the receptor. Further, these data show the Lattice Light-Sheet’s capabilities for imaging tissue with problematic background fluorescence that otherwise makes super-resolution fluorescence microscopy difficult.

59 BASIC BIOLOGICAL SCIENCES↗

Hyperspectral data analysis for estimation of foliar biochemical content along the Oregon transect

The NASA Oregon Transect Ecosystem Research (OTTER) project completed a data acquisition phase. Data were acquired with several airborne imaging spectrometers. Included were the Airborne Visible and Infrared Imaging Spectrometer (AVIRIS) aboard the ER-2, the Advanced Solidstate Array Spectrometer (ASAS) aboard the C-130, and the Fluorescence Line Imager (FLI) and Compact Airborne Spectrographic Imager (CASI), both aboard light aircraft. In addition, Spectron visible and near-infrared data were acquired in transects across study areas from a low-altitude ultralight craft. Sunphotometer data were taken approximately coincident with each overflight for atmospheric correction of the aircraft data.

Johnson, Lee F.↗

NASA Tech Briefs, December 2007

Topics include: Ka-Band TWT High-Efficiency Power Combiner for High-Rate Data Transmission; Reusable, Extensible High-Level Data-Distribution Concept; Processing Satellite Imagery To Detect Waste Tire Piles; Monitoring by Use of Clusters of Sensor-Data Vectors; Circuit and Method for Communication Over DC Power Line; Switched Band-Pass Filters for Adaptive Transceivers; Noncoherent DTTLs for Symbol Synchronization; High-Voltage Power Supply With Fast Rise and Fall Times; Waveguide Calibrator for Multi-Element Probe Calibration; Four-Way Ka-Band Power Combiner; Loss-of-Control-Inhibitor Systems for Aircraft; Improved Underwater Excitation-Emission Matrix Fluorometer; Metrology Camera System Using Two-Color Interferometry; Design and Fabrication of High-Efficiency CMOS/CCD Imagers; Foam Core Shielding for Spacecraft CHEM-Based Self-Deploying Planetary Storage Tanks Sequestration of Single-Walled Carbon Nanotubes in a Polymer PPC750 Performance Monitor Application-Program-Installer Builder Using Visual Odometry to Estimate Position and Attitude Design and Data Management System Simple, Script-Based Science Processing Archive Automated Rocket Propulsion Test Management Online Remote Sensing Interface Fusing Image Data for Calculating Position of an Object Implementation of a Point Algorithm for Real-Time Convex Optimization Handling Input and Output for COAMPS Modeling and Grid Generation of Iced Airfoils Automated Identification of Nucleotide Sequences Balloon Design Software Rocket Science 101 Interactive Educational Program Creep Forming of Carbon-Reinforced Ceramic-Matrix Composites Dog-Bone Horns for Piezoelectric Ultrasonic/Sonic Actuators Benchtop Detection of Proteins Recombinant Collagenlike Proteins Remote Sensing of Parasitic Nematodes in Plants Direct Coupling From WGM Resonator Disks to Photodetectors Using Digital Radiography To Image Liquid Nitrogen in Voids Multiple-Parameter, Low-False-Alarm Fire-Detection Systems Mosaic-Detector-Based Fluorescence Spectral Imager Plasmoid Thruster for High Specific-Impulse Propulsion Analysis Method for Quantifying Vehicle Design Goals Improved Tracking of Targets by Cameras on a Mars Rover Sample Caching Subsystem Multistage Passive Cooler for Spaceborne Instruments GVIPS Models and Software Stowable Energy-Absorbing Rocker-Bogie Suspensions

Source record↗

Self‐Assembly Methods Induce Different Individual‐Polymer‐Block Solvation Responses

An understanding of block-specific responses to stimuli in self-assembled copolymers is essential for the effective design of responsive materials. Here, materials formed from different post-reaction processing methods of the same ROMP block copolymer exhibit different block-specific solvent responses, as characterized in situ by fluorescence lifetime imaging microscopy (FLIM). FLIM data were acquired by tagging the polar or nonpolar block separately with a covalently incorporated viscosity-sensitive fluorescent molecular rotor to measure the changing tightness or looseness of assembly upon changes in solvent composition. Rapid precipitation from an insoluble solvent to form a film results in tighter assembly and less difference in tightness/looseness between the two blocks. Further, it interrupts individual block-solvent response behavior. Both results indicate an apparent disruption of the core–shell assembly. This model from FLIM is further supported by differential scanning calorimetry (DSC) and small-angle X-ray scattering (SAXS) data from isolated solids, which show tighter long-range interactions and more long-range order in these kinetically trapped states. Here, the experiments develop FLIM as a method for pinpointing stimuli-responsive behaviors from different processing methods to individual blocks. Together these outcomes provide a future handle for tailoring solvent-triggered assembly/disassembly behavior.

López, Pía A. [University of California, Irvine, C↗

Infrared images of reflection nebulae and Orion's bar: Fluorescent molecular hydrogen and the 3.3 micron feature

Images were obtained of the (fluorescent) molecular hydrogen 1-0 S(1) line, and of the 3.3 micron emission feature, in Orion's Bar and three reflection nebulae. The emission from these species appears to come from the same spatial locations in all sources observed. This suggests that the 3.3 micron feature is excited by the same energetic UV-photons which cause the molecular hydrogen to fluoresce.

Burton, Michael G.↗

Instantaneous velocity field imaging instrument for supersonic reacting flows

The technical tasks conducted to develop and demonstrate a new gas velocity measurement technique for high enthalpy reacting flows is described. The technique is based on Doppler-shifted Planar Laser-induced Fluorescence (PLIF) imaging of the OH radical. The imaging approach permits, in principle, single-shot measurements of the 2-D distribution of a single velocity component in the measurement plane, and is thus a technique of choice for applications in high enthalpy transient flow facilities. In contrast to previous work in this area, the present program demonstrated an approach which modified the diagnostic technique to function under the constraints of practical flow conditions of engineering interest, rather than vice-versa. In order to accomplish the experimental demonstrations, the state-of-the-art in PLIF diagnostic techniques was advanced in several ways. Each of these tasks is described in detail and is intended to serve as a reference in supporting the transition of this new capability to the fielded PLIF instruments now installed at several national test facilities. Among the new results of general interest in LlF-based flow diagnostics, a detailed set of the first measurements of the collisional broadening and shifting behavior of OH (1,0) band transitions in H7-air combustion environments is included. Such measurements are critical in the design of a successful strategy for PLIF velocity imaging; they also relate to accurate concentration and temperature measurements, particularly in compressible flow regimes. Furthermore, the results shed new light on the fundamental relationship between broadening and energy transfer collisions in OH A(sup 2)Sigma(+)v(sup ') = 1. The first single-pulse, spectrally-resolved measurements of the output of common pulsed dye lasers were also produced during the course of this effort. As with the OH broadening measurements, these data are a significant aspect of a successful velocity imaging strategy, and also have potential implications for many other LIF measurement techniques. Our results indicated the need to modify the commercially available laser cavity in order to accommodate the constraints imposed by typical SCRAMJET combustion characteristics as well as to increase the instrument's velocity dynamic range to span an intra-image range in excess of 2 km/s. The various technical efforts were brought together in a series of experiments demonstrating the applicability of the technique in a high pressure, high temperature H2-air combustion system. The resultant images were compared with 2-D flow simulations in order to determine the accuracy of the instrument. Mean velocity imaging in flows with an axis of symmetry was demonstrated with an accuracy of +/- 50 m/s out of an intra-image dynamic range of 1600 m/s, including reversed flow. A more complex configuration amenable to single-shot imaging in flows without an axis of symmetry was also demonstrated. Limitations imposed by available equipment resulted in an accuracy of about +/- 200 m/s out of 1750 m/s in these demonstrations. Minor modifications to the present configuration were suggested to improve this performance. Each technical task is described in detail, along with significance of the results for the overall imaging velocimeter configuration. This report should allow the user community to integrate this new measurement capability in their existing instrumentation platforms.

Allen, M. G.↗

Exposed Phosphatidylserine as a Biomarker for Clear Identification of Breast Cancer Brain Metastases in Mouse Models

Brain metastasis is the most common intracranial malignancy in adults. The prognosis is extremely poor, partly because most patients have more than one brain lesion, and the currently available therapies are nonspecific or inaccessible to those occult metastases due to an impermeable blood–tumor barrier (BTB). Phosphatidylserine (PS) is externalized on the surface of viable endothelial cells (ECs) in tumor blood vessels. In this study, we have applied a PS-targeting antibody to assess brain metastases in mouse models. Fluorescence microscopic imaging revealed that extensive PS exposure was found exclusively on vascular ECs of brain metastases. The highly sensitive and specific binding of the PS antibody enables individual metastases, even micrometastases containing an intact BTB, to be clearly delineated. Furthermore, the conjugation of the PS antibody with a fluorescence dye, IRDye 800CW, or a radioisotope, 125I, allowed the clear visualization of individual brain metastases by optical imaging and autoradiography, respectively. In conclusion, we demonstrated a novel strategy for targeting brain metastases based on our finding that abundant PS exposure occurs on blood vessels of brain metastases but not on normal brain, which may be useful for the development of imaging and targeted therapeutics for brain metastases.

Oncology↗

PLIF Visualization of Active Control of Hypersonic Boundary Layers Using Blowing

Planar laser-induced fluorescence (PLIF) imaging was used to visualize the boundary layer flow on a 1/3-scale Hyper-X forebody model. The boundary layer was perturbed by blowing out of orifices normal to the model surface. Two blowing orifice configurations were used: a spanwise row of 17-holes spaced at 1/8 inch, with diameters of 0.020 inches and a single-hole orifice with a diameter of 0.010 inches. The purpose of the study was to visualize and identify laminar and turbulent structures in the boundary layer and to make comparisons with previous phosphor thermography measurements of surface heating. Jet penetration and its influence on the boundary layer development was also examined as was the effect of a compression corner on downstream boundary layer transition. Based upon the acquired PLIF images, it was determined that global surface heating measurements obtained using the phosphor thermography technique provide an incomplete indicator of transitional and turbulent behavior of the corresponding boundary layer flow. Additionally, the PLIF images show a significant contribution towards transition from instabilities originating from the underexpanded jets. For this experiment, a nitric oxide/nitrogen mixture was seeded through the orifices, with nitric oxide (NO) serving as the fluorescing gas. The experiment was performed in the 31-inch Mach 10 Air Tunnel at NASA Langley Research Center.

Bathel, Brett F.↗

Biophotonics and Bone Biology

One of the more serious side effects of extended space flight is an accelerated bone loss. Rates of bone loss are highest in the weight-bearing bones of the hip and spine regions, and the average rate of bone loss as measured by bone mineral density measurements is around 1.2% per month for persons in a microgravity environment. It is well known that bone remodeling responds to mechanical forces. We are developing two-photon microscopy techniques to study bone tissue and bone cell cultures to better understand the fundamental response mechanism in bone remodeling. Osteoblast and osteoclast cell cultures are being studied, and the goal is to use molecular biology techniques in conjunction with Fluorescence Lifetime Imaging Microscopy (FLIM) to study the physiology of in-vitro cell cultures in response to various stimuli, such as fluid flow induced shear stress and mechanical stress. We have constructed a two-photon fluorescence microscope for these studies, and are currently incorporating FLIM detection. Current progress will be reviewed. This work is supported by the NASA John Glenn Biomedical Engineering Consortium.

Zimmerli, Gregory↗

Super-resolution imaging reveals resistance to mass transfer in functionalized stationary phases

Chemical separations are costly in terms of energy, time, and money. Separation methods are optimized with inefficient trial-and-error approaches that lack insight into the molecular dynamics that lead to the success or failure of a separation and, hence, ways to improve the process. We perform super-resolution imaging of fluorescent analytes in five different commercial liquid chromatography materials. Unexpectedly, we observe that chemical functionalization can block more than 50% of the material’s porous interior, rendering it inaccessible to small-molecule analytes. Only in situ imaging unveils the inaccessibility when compared to the industry-accepted ex situ characterization methods. Selectively removing some of the functionalization with solvent restores pore access without substantially altering the single-molecule kinetics that underlie the separation and agree with bulk chromatography measurements. Our molecular results determine that commercial “fully porous” stationary phases are over-functionalized and provide an alternative avenue to characterize and direct separation material design from the bottom-up.

Science & Technology - Other Topics↗

SHERLOC Investigations at the Máaz and Séítah formations within Jezero crater

Introduction: The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) instrument combines microscopic imaging, native fluorescence and Raman spectroscopy to better understand the mineral and chemical makeup of rocks on the martian surface. Native fluorescence emissions from aromatic organic species allow for detection and classification of aromatic organic molecules, whereas Raman scattered photons from molecules allow identification of functional groups of organics, chemicals, and minerals. These signatures are obtained on a 100 micron spatial scale and collocated to images so textures, minerals and chemicals can all be compared [1]. Results: SHERLOC has been operating on Mars since February 18, 2021. As of this writing, we have analyzed 3 natural surfaces, and 5 abraded rock patches created during the Crater Floor Campaign within Jezero crater [2]. The Guillaumes target (from the Roubion outcrop, Roubion member of the Máaz Formation) is dominated by Ca-sulfate with patches of perchlorate. The Bellegarde target (from the Rochette outcrop, Rochette member of the Máaz Formation) exhibits Raman peaks that match hydrated Ca-sulfate, amorphous/microcrystalline silicate (AMS), carbonate, and phosphate phases. A fluorescence doublet at ~305 and ~325 nm was detected and is most likely due to indigenous organic material in the sample. The Garde target (from the Bastide outcrop, Bastide member of the Séítah Formation) is dominated by olivine and carbonate with AMS occurring across the material. The Dourbes target (from the Brac outcrop, Bastide member of the Séítah Formation) is dominated by olivine and shows minor amounts of carbonate, hydrated Ca-sulfate, and AMS. The Quartier target exhibits a large sulfate feature, as well as carbonate, perchlorate, olivine and a fluorescence doublet at 305 and 325 nm and is very similar to that observed at Bellegarde. In each of these samples we have identified fluorescence features that are likely aromatic organics native to the rock interiors. Acknowledgments: This work was carried out at the Jet Propulsion Laboratory, The California Institute of Technology under a contract from NASA.

L W Beegle↗

Comparison of Techniques for Non-Intrusive Fuel Drop Size Measurements in a Subscale Gas Turbine Combustor

In aviation gas turbine combustors, many factors, such as the degree and extent of fuel/air mixing and fuel vaporization achieved prior to combustion, influence the formation of undesirable pollutants. To assist in analyzing the extent of fuel/air mixing, flow visualization techniques have been used to interrogate the fuel distributions during subcomponent tests of lean-burning fuel injectors. Discrimination between liquid and vapor phases of the fuel was determined by comparing planar laser-induced fluorescence (PLIF) images, elastically-scattered light images, and phase/Doppler interferometer measurements. Estimates of Sauter mean diameters are made by ratioing PLIF and Mie scattered intensities for various sprays, and factors affecting the accuracy of these estimates are discussed. Mie calculations of absorption coefficients indicate that the fluorescence intensities of individual droplets are proportional to their surface areas, instead of their volumes, due to the high absorbance of the liquid fuel for the selected excitation wavelengths.

Zaller, Michelle↗

Altered excitation energy transfer between phycobilisome and photosystems in the absence of ApcG, a small linker peptide, in Synechocystis sp. PCC 6803, a cyanobacterium

Phycobilisome (PBS) is a large pigment-protein complex in cyanobacteria and red algae responsible for capturing sunlight and transferring its energy to photosystems (PS). Spectroscopic and structural properties of various PBSs have been widely studied, however, the nature of so-called complex-complex interactions between PBS and PSs remains much less explored. In this work, we have investigated the function of a newly identified PBS linker protein, ApcG, some domain of which, together with a loop region (PB-loop in ApcE), is possibly located near the PBS-PS interface. Using Synechocystis sp. PCC 6803, we generated an ApcG deletion mutant and probed its deletion effect on the energetic coupling between PBS and photosystems. Steady-state and time-resolved spectroscopic characterization of the purified ΔApcG-PBS demonstrated that ApcG removal weakly affects the photophysical properties of PBS that the spectroscopic properties of terminal energy emitters are comparable to those of PBS from wild-type. However, analysis of fluorescence decay imaging datasets reveals that ApcG deletion induces disruptions within the allophycocyanin (APC) core, resulting in the emergence (splitting) of two spectrally diverse subgroups with some short-lived APC. Profound spectroscopic changes of the whole ΔApcG mutant cell, however, emerge during state transition, a dynamic process of light scheme adaptation. The mutant cells in State I show a substantial increase in PBS-related fluorescence. On the other hand, global analysis of time-resolved fluorescence demonstrates that in general ApcG deletion does not alter or inhibit state transitions if it is interpreted only in terms of the changes of the PSII and PSI fluorescence emission intensity. Furthermore, the results revealed yet–to–be discovered mechanism of ApcG-docking induced excitation energy transfer regulation within PBS or to Photosystems.

59 BASIC BIOLOGICAL SCIENCES↗

Planar Imaging of Hydroxyl in a High Temperature, High Pressure Combustion Facility

An optically accessible flame tube combustor is described which has high temperature, pressure, and air flow capabilities. The windows in the combustor measure 3.8 cm axially by 5.1 cm radially, providing 67 percent optical access to the square cross section flow chamber. The instrumentation allows one to examine combusting flows and combustor subcomponents, such as fuel injectors and air swirlers. These internal combustor subcomponents have previously been studied only with physical probes, such as temperature and species rakes. Planar laser-induced fluorescence (PLIF) images of OH have been obtained from this lean burning combustor burning Jet-A fuel. These images were obtained using various laser excitation lines of the OH A yields X (1,0) band for two fuel injector configurations with pressures ranging from 1013 kPa (10 atm) to 1419 kPa (14 atm), and equivalence ratios from 0.41 to 0. 59. Non-uniformities in the combusting flow, attributed to differences in fuel injector configuration, are revealed by these images.

Hicks, Yolanda R.↗

Root size and soil physicochemical properties drive microscale spatial patterns of Fe and As retention in the rice rhizosphere

Background and Aims: Radial oxygen loss from rice roots in flooded soils oxidizes and precipitates dissolved Fe(II), Mn(II), and As(III) into mixed Fe(III), Mn(III/IV), and As(V) as root plaque and in the rhizosphere soil. It is unknown how different soils and root sizes impact the spatial extent of Fe and As retention outside the root. Methods: We imaged cross-sections of 90 roots from 6 different soils using synchrotron μXRF imaging followed by k-means clustering and elliptical averaging to distinguish bulk soil, rhizosphere, plaque, and roots based on As and Fe patterns. Results: We found preferential As retention in the plaque and rhizospheres of most roots except small (< 0.45 mm) roots in silty soils with low P or high As. In contrast, clayey soils had similar As-Fe correlations across plaque, rhizosphere, and bulk soil. Large (> 0.45 mm) roots often had no oxidized rhizosphere region. We obtained an extensive dataset of 256 As and 155 Mn synchrotron μXANES measurements, which revealed that rhizosphere and plaque As was mainly inorganic As(V) and As(III), and Mn oxidation state varied between soils but not between belowground locations. Conclusion: Small roots in coarse-textured soils were less likely to have As retention in the plaque or rhizosphere compared to large roots and fine-textured soils. Furthermore, the unique and extensive data in this study provides new insight into soil and root size impacts on As retention in the rhizosphere. It is essential to investigate a representative number of samples to draw conclusions from XRF imaging.

36 MATERIALS SCIENCE↗

Injectant mole-fraction imaging in compressible mixing flows using planar laser-induced iodine fluorescence

A technique is described for imaging the injectant mole-fraction distribution in nonreacting compressible mixing flow fields. Planar fluorescence from iodine, seeded into air, is induced by a broadband argon-ion laser and collected using an intensified charge-injection-device array camera. The technique eliminates the thermodynamic dependence of the iodine fluorescence in the compressible flow field by taking the ratio of two images collected with identical thermodynamic flow conditions but different iodine seeding conditions.

Hartfield, Roy J., Jr.↗

Precision Labeling of Native Antibodies with Lock Coupling

The formation of stable protein complexes enables much of biotechnology, but even high-affinity complexes can dissociate, limiting potential applications in biomaterials, bioimaging, nanomedicine, and other protein-based technologies. Here, in this study, we describe lock coupling, a simple and selective one-step reaction between interfacial lysine and glutamate or aspartate side chains to form stable isopeptide bonds and be used for the precise labeling of native antibodies. We identify conditions in which short-lived activated esters formed by the aqueous carbodiimide EDC promote isopeptide bond formation specifically at preassociated amine-acid pairs. Indiscriminate cross-linking is minimized by formation of protein complexes before addition of catalyst, use of acidic pH to suppress exposed Lys reactivity, and limiting the aqueous stability of activated esters. For native antibody (Ab) labeling, we show that the small IgG-binding protein GB1 can be covalently attached to the Ab Fc domain and that introduction of Cys into GB1 loops allows for facile conjugation of fluorophores, micelles, or inorganic nanocrystals for imaging in live cells and animals. By varying Cys substituents and protein stoichiometry, a defined number of probes can be uniformly attached without the need for extensive purification. In live-cell confocal microscopy, labeled GB1 serves as a stable replacement for secondary Abs, enabling simple multicolor immunostaining and imaging. Lock coupling requires just a single reagent in aqueous buffer and leverages both the innate ability of proteins to form high-affinity complexes and the widespread presence of Lys-Glu/Asp pairs at their interfaces, with the potential for precision synthesis of protein-based probes for imaging, biomaterials, biophysics, and medicine.

antibody↗