Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Tatsuno Coriolis Flow Meter Development Testing in High Pressure Hydrogen: Cooperative Research and Development Final Report

This project will provide test data on the new Tatsuno coriolis flow meter. This flow meter has been developed by Tatsuno for the purpose of achieving improved flow meter performance for 70 mega pascal (MPA) hydrogen dispensing. Testing will be conducted at the National Renewable Laboratory (NREL) Hydrogen Infrastructure Testing and Research Facility (HITRF) facility utilizing the hydrogen flow meter benchmark testing apparatus. The benchmarking apparatus utilizes a gravimetric method for measuring flow for direct comparison with flow meter output. Using the NREL meter benchmarking apparatus will allow direct comparison with data taken on previous versions of the Tatsuno coriolis flow meter product. Flow meter accuracy at 70 MPA hydrogen dispensers is an issue that has generated a lot of effort by both standards organizations and the station providers.

33 ADVANCED PROPULSION SYSTEMS↗

Facility to Alleviate Salt Technology Risks (FASTR): Preliminary Design Report with Failure Modes and Effects Analysis

The Facility to Alleviate Salt Technology Risks (FASTR) is a versatile, high-temperature (>600°C) molten chloride salt test facility designed to enable a variety of testing to advance the Generation 3 (Gen 3) Concentrated Solar Power (CSP) molten salt technology. FASTR includes a salt preparation system and a forced flow test loop with a suite of instrumentation. The FASTR loop is capable of 725°C operation, flow rates of 3–7 kg/s, includes heated and cooled sections, and swappable components to enable testing of future vendor-supplied hardware. The salt preparation system supplies large batches (e.g., 200 kg) of clean salt for use in the FASTR forced convection loop. This report summarizes the planned design and capabilities of FASTR. In addition, a failure modes and effects analysis of the system is reported.

42 ENGINEERING↗

Facility to Alleviate Salt Technology Risks (FASTR): Design Report

The Facility to Alleviate Salt Technology Risks (FASTR) is a versatile, high-temperature (>600°C) molten chloride salt test facility designed to enable a variety of testing to advance the Generation 3 (Gen 3) Concentrated Solar Power (CSP) molten salt technology. FASTR includes a salt preparation system and a forced flow test loop with a suite of instrumentation. The FASTR loop is capable of 725°C operation and flow rates of 3–7 kg/s, and it includes heated and cooled sections and swappable components to enable testing of future vendor-supplied hardware. The salt preparation system supplies large batches (e.g., 200 kg) of clean salt for use in the FASTR forced convection loop. This report summarizes the design and capabilities of FASTR in its as-built form as of December 2022.

14 SOLAR ENERGY↗

Facility to Alleviate Salt Technology Risks (FASTR): Commissioning Update

The Facility to Alleviate Salt Technology Risks (FASTR) is a versatile, high-temperature (>600°C) molten chloride salt test facility designed to enable a variety of testing to advance the Generation 3 (Gen 3) concentrated solar power (CSP) molten salt technology. FASTR includes a salt preparation system and a forced flow test loop with a suite of instrumentation. The FASTR loop is capable of operating at 725°C with flow rates of 3–7 kg/s, and it includes heated and cooled sections and swappable components to facilitate testing future vendor-supplied hardware. The salt preparation system supplies large batches of clean salt for use in the FASTR forced circulation loop. This report summarizes the shakedown and initial operation of the FASTR forced circulation loop through December 2022.

14 SOLAR ENERGY↗

Phase shift method to estimate solids circulation rate in circulating fluidized beds

While solids circulation rate is a critical design and control parameter in circulating fluidized bed (CFB) reactor systems, there are no available techniques to measure it directly at conditions of industrial interest. Cold flow tests have been conducted at NETL in an industrial scale CFB unit where the solids flow has been the topic of research in order to develop an independent method which could be applied to CFBs operating under the erosive and corrosive high temperatures and pressures of a coal fired boiler or gasifier. The dynamic responses of the CFB loop to modest modulated aeration flows in the return leg or standpipe were imposed to establish a periodic response in the unit without causing upset in the process performance. The resulting periodic behavior could then be analyzed with a dynamic model and the average solids circulation rate could be established. This method was applied to the CFB unit operated under a wide range of operating conditions including fast fluidization, core annular flow, dilute and dense transport, and dense suspension upflow. In addition, the system was operated in both low and high total solids inventories to explore the influence of inventory limiting cases on the estimated results. The technique was able to estimate the solids circulation rate for all transport circulating fluidized beds when operating above upper transport velocity, U{sub tr2}. For CFB operating in the fast fluidized bed regime (i.e., U{sub g}< U{sub tr2}), the phase shift technique was not successful. The riser pressure drop becomes independent of the solids circulation rate and the mass flow rate out of the riser does not show modulated behavior even when the riser pressure drop does.

42 ENGINEERING↗

Entropy-based viscous regularization for the multi-dimensional Euler equations in low-Mach and transonic flows

We present a new version of the entropy viscosity method, a viscous regularization technique for hyperbolic conservation laws, that is well-suited for low-Mach flows. By means of a low-Mach asymptotic study, new expressions for the entropy viscosity coefficients are derived. These definitions are valid for a wide range of Mach numbers, from subsonic flows (with very low Mach numbers) to supersonic flows, and no longer depend on an analytical expression for the entropy function. In addition, the entropy viscosity method is extended to Euler equations with variable area for nozzle flow problems. The effectiveness of the method is demonstrated using various 1-D and 2-D benchmark tests: flow in a converging–diverging nozzle; Leblanc shock tube; slow moving shock; strong shock for liquid phase; low-Mach flows around a cylinder and over a circular hump; and supersonic flow in a compression corner. Convergence studies are performed for smooth solutions and solutions with shocks present.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Distributed fiber sensing systems for 3D combustion temperature field monitoring in coal-fired boilers using optically generated acoustic waves (Final Report)

In this project, we have developed and tested three kinds of fiber optic sensing systems for real time monitoring of temperature variations within an industrial scale boiler furnace. The fiber optic sensing systems target spatial and temporal distributions of high temperature profiles in a boiler furnace in fossil power plants. The reconstructed temperature profile will provide critical input for the control mechanisms to optimize the combustion process. This temperature profile will address the essential problem for fossil power plants in achieving higher efficiency and fewer pollutant emissions. Acoustic pyrometer systems have been used to reconstruct temperature field of power plant boilers based on measuring TOF (times-of-flight) of sound waves along some straight paths in a 2D cross-section of the boiler. In this project, optically generated acoustic signals from a fiber optic sensing system have replaced the acoustic signals generated from an electrical transducer. A 3D reconstruction algorithm replaced the previous 2D model. In this project, three kinds of fiber optic sensing systems have been developed and tested. They are fiber optic sensing system I, fiber optic sensing system II (Distributed Sensing System I) and fiber optic sensing system III (Distributed Sensing System II). For fiber optic sensing system I, the fiber optic ultrasound generator acts as a signal generator. A microphone, hydrophone or other electronic devices serve as a signal receiver. In this system, there are one generator and one receiver. Distance test, water temperature test, air temperature test, air temperature reconstruction, and GE ISBF pilot test were performed by Fiber optic sensing system I. The fiber optic sensing system I successfully detected temperature in all these tests. We got 2D temperature reconstruction results by using the fiber optic sensing system I and it matched the reference data. The fiber optic sensing system I successfully survived in GE ISBF boiler environment (480 °F). For fiber optic sensing system II (Distributed Sensing System I), it is an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Fiber Bragg Grating (FBG) and Fabry-Perot (FP) sensor act as a signal receiver. In this system, there is one generator and one receiver. Aluminum plate temperature test, furnace high temperature test, and GE ISBF pilot test were performed by the fiber optic sensing system II. Fiber optic sensing system II successfully detected the temperature in all these tests. The fiber optic sensing system II successfully survived at up to 700 °C furnace environment and 320 °C GE ISBF boiler environment. For fiber optic sensing system III (Distributed Sensing System II), it is also an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Multiple FP fiber sensors act as signal receivers. In this system, there is one generator and three receivers. Three GE ISBF pilot tests were performed by fiber optic sensing system III. The fiber optic sensing system III survived in the cold flow tests in GE’s ISBF pilot test facility. However, we didn’t get high temperature data by using this system since the nanosecond laser issues. During the period of the project, test trials, data simulation and algorithm optimization was performed successfully. For real time temperature field construction, the sampling rate must be fast enough to capture the field variations. The technology of Code-division multiple access (CDMA) is well studied which could allow parallel multiplexing, even if signals overlap in time or frequencies. Moreover, it has been known that extending the length of signal significantly improves SNR. For acoustic signals, these multiplexing techniques have also been widely used, mainly for sonar and acoustic communications. The CDMA modulation technique has been proposed and studied to guarantee high network throughput, low channel access delay and low energy consumption. We have studied the temperature field reconstruction using Gaussian Radial Basis Functions (GRBF)-based approximation approach. Reconstruction of 3D temperature field using Neural Networks with measured TOF and known propagation paths is feasible. 2D and 3D temperature field reconstruction simulation results are achieved. The milestone status is shown in Table 1. We finished milestone 1-8 and milestone 10. For milestone 9, we did three pilot tests by using the fiber optic sensing system III (Distributed Sensing System II) at GE Power. However, due to the failure of the ns laser, we did not get the temperature results. We conducted some additional tasks that were not originally proposed: 1) We fabricated a fiber optic sensing system I and did a pilot test based on this system. 2) In the proposal, we proposed two pilot tests at GE Power. In reality, we finished at least seven pilot tests at GE Power. GE Power has made a lot of efforts for supporting the pilot tests. 3) We got a simulation results based on CDMA. In summary, most of the tasks have been accomplished. The outcome of this project removed a few barriers that hinder the achievement of the final product of the distributed sensing systems. With the successful accomplishment of this project, a prototype of the fiber optic sensing system can be fabricated to attract more interests from companies and other funding agencies.

47 OTHER INSTRUMENTATION↗

Validation of a plant dynamics code for 4S - Test analysis of natural circulation behavior

A plant transient dynamics code for a sodium-cooled fast reactor was developed by Toshiba. The code is used to evaluate the safety performance of Super-Safe, Small, and Simple reactor (4S) for Anticipated Operational Occurrences (AOOs), Design Basis Accident (DBA) and Beyond DBA (BDBA). The code is currently undergoing verification and validation (V and V). As one of the validation, test analysis of the Shutdown Heat Removal Test (SHRT)-17 performed in the Experimental Breeder Reactor (EBR)-II was conducted. The SHRT-17 is protected loss of flow test. The purpose of this validation is to confirm capability of the code to simulate natural circulation behavior of the plant. As a result, good agreements are shown between the analytical results and the measured data which were available from instrumented subassembly. The detailed validation result of the natural circulation behavior is described in this paper. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Bench-Scale Testing and Process Performance Projections of CO2 Capture by CO2–Binding Organic Liquids (CO2BOLs) With and Without Polarity-Swing-Assisted Regeneration

This manuscript provides a detailed analysis of a continuous flow, bench scale study of the CO2BOL solvent platform with and without its Polarity Swing Assisted Regeneration (PSAR). This study encompassed four months of continuous flow testing of a candidate CO2BOL with a thermal regeneration and PSAR regeneration using decane antisolvent. In both regeneration schemes, steady state capture of >90 %CO2 was achieved using simulated flue gas at acceptable L/G ratios. Aspen Plus™ modeling was performed to assess process performance compared to previous equilibrium performance projections. This paper also includes net power projections, and comparisons to DOE’s Case 10 amine baseline.

Zheng, Feng↗

Thermal hydraulic analysis of the AFIP-7 irradiation test in the Advanced test Reactor – Model correlation and performance evaluation

We report as a system level code, RELAP5 is widely used in the nuclear field for the reactor hydraulic analysis. In the component/experimental level, it is frequently employed as well. This paper demonstrates that the RELAP5 flow simulation of the AFIP-7 irradiation experiment which has a complicated 3D geometry/flow path deviates by ~28% from the flow evaluation through a computational fluid dynamics (CFD) simulation, which has been validated against a flow test performed at Oregon State University. Thermal safety compliance analysis of an experiment planned to be irradiated in the Advanced Test Reactor is usually performed using the finite element analysis code, Abaqus. This research reveals the disadvantages of the Abaqus simulation in the flow instability and departure from nucleate boiling evaluations via a conjugate heat transfer analysis of the AFIP-7 irradiation experiment. As a result, a detailed CFD simulation is suggested for irradiation experiments with complicated flow paths, rather than a simplified RELAP5 simulation or hand calculations. The validated simulation approach will be integrated with the Boehmite correlations to investigate the oxide growth prediction on the fuel cladding in Part II of this research.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Akutan Geothermal: Resource Report

Geothermal energy resources are present in the Hot Springs Bay Valley geothermal area, and the City has invested considerable money and time in the exploration of the resource for future use. Exploration activities funded primarily through a grant the City was awarded from Alaska Energy Authority and later supplemented by the U. S. Department of Energy (DOE), with cost share from the City. The exploration led to the development of a geothermal resource conceptual model that was built and refined between 2008 and 2018. During this period, geological and geophysical studies, exploration drilling and other activities were completed, including a preliminary feasibility study for a power project, investigations of the terrain for suitability for access and development, environmental and archeological review, plus TG well abandonment and a review of economic considerations. The model of the resource predicts that there is a viable geothermal resource in two general areas: on the northwest edge of Hot Springs Bay Valley going northwest of the valley (hot springs area) and southwest of the Valley (fumarole area). The resource temperature for the valley area is expected to be about 170°C (340°F) and given the size and permeability estimates (with a factor for the level of confidence in the estimates), the mean power capacity of the outflow resource is 3 MWe and the P50 (most likely) power capacity is 1 MWe. The fumarole area has an expected resource temperature of 240°C (464°F) and given the size and permeability estimates mean capacity is 20 MWe and the P50 (most likely) capacity is 9 MWe. Permeability is the most difficult factor to predict and has a significant impact on the available geothermal fluids and therefore the amount of power that can be generated. The uncertainty in this value is the main reason for lower confidence in the likelihood of exploration success and the wide range in predicted MW values. The permeability has been difficult to locate as indicated by the results of the flow test at AK-3 in 2017. The test resulted in the production of some fluid, but due to low permeability, the recharge to the wellbore was too slow to sustain flow. The greatest probability of overall MWe production is in the fumarole region, but development is hampered by poor accessibility. The extremely high cost of road building for exploratory drilling, put an end to planning at an intermediate stage of the project and refocused attention on the viability of development in the hot spring outflow part of the resource. The City will be determining what the next steps are with AK-3, which is still that is still open and maintained in a suspended status in HSBV. While AK-3 remains accessible (not plugged with cement) it will need to be maintained. The City has a bond with AOGCC that will remain in place until the well is abandoned. GRG recommends that the well be maintained open as an asset for the foreseeable future.

15 GEOTHERMAL ENERGY↗

Benchmark specifications for EBR-II shutdown heat removal tests

Argonne National Laboratory (ANL) is hosting an IAEA-coordinated research project on benchmark analyses of sodium-cooled fast reactor passive safety tests performed at the Experimental Breeder Reactor-II (EBR-II). The benchmark project involves analysis of a protected and an unprotected loss of flow tests conducted during an extensive testing program within the framework of the U.S. Integral Fast Reactor program to demonstrate the inherently safety features of EBR-II as a pool-type, sodium-cooled fast reactor prototype. The project is intended to improve the participants' design and safety analysis capabilities for sodium-cooled fast reactors through validation and qualification of safety analysis codes and methods. This paper provides a description of the EBR-II tests included in the program, and outlines the benchmark specifications being prepared to support the IAEA-coordinated research project. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Uncertainty methodology for the strongly coupled physical phenomena associated with annular flow

Best-Estimate plus Uncertainty (BEPU) methods are slowly supplanting the use of deterministic analysis methods for thermal-hydraulic analyses. As the uncertainty methodologies evolve it is expected that, where both experimental techniques allow and data are available, there will be a shift to quantifying the uncertainty in increasingly more fundamental parameters. For example, for annular flow in a three-field analysis environment (vapor, liquid film, droplet), the driving parameters would be: a) film interfacial shear stress, b) droplet drag, c) droplet entrainment rate and d) droplet deposition rate. An improved annular flow modeling package was recently developed and implemented in an in-house version of the COBRA-TF best-estimate subchannel analysis tool (Lane, 2009). Significant improvement was observed in the code-to-data predictions of several steam-water annular flow tests following the implementation of this modeling package; however, to apply this model set in formal BEPU analysis requires uncertainty distributions to be determined. The unique aspect of annular flow, and the topic of the present work, is the strong coupling between the interfacial drag, entrainment and deposition phenomena. Ideally the uncertainty in each phenomenon would be isolated; however, the situation is further complicated by an inability to experimentally isolate and measure the individual rate processes (particularly entrainment rate), which results in available experimental data that are inherently integral in nature. This paper presents a methodology for isolating the individual physical phenomena of interest, to the extent that the currently available experimental data allow, and developing the corresponding uncertainty distributions for annular flow. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Full waveform inversion of solar interior flows

The inference of flows of material in the interior of the Sun is a subject of major interest in helioseismology. Here, we apply techniques of full waveform inversion (FWI) to synthetic data to test flow inversions. In this idealized setup, we do not model seismic realization noise, training the focus entirely on the problem of whether a chosen supergranulation flow model can be seismically recovered. We define the misfit functional as a sum of L {sub 2} norm deviations in travel times between prediction and observation, as measured using short-distance filtered f and p {sub 1} and large-distance unfiltered p modes. FWI allows for the introduction of measurements of choice and iteratively improving the background model, while monitoring the evolution of the misfit in all desired categories. Although the misfit is seen to uniformly reduce in all categories, convergence to the true model is very slow, possibly because it is trapped in a local minimum. The primary source of error is inaccurate depth localization, which, due to density stratification, leads to wrong ratios of horizontal and vertical flow velocities ({sup c}ross talk{sup )}. In the present formulation, the lack of sufficient temporal frequency and spatial resolution makes it difficult to accurately localize flow profiles at depth. We therefore suggest that the most efficient way to discover the global minimum is to perform a probabilistic forward search, involving calculating the misfit associated with a broad range of models (generated, for instance, by a Monte Carlo algorithm) and locating the deepest minimum. Such techniques possess the added advantage of being able to quantify model uncertainty as well as realization noise (data uncertainty).

79 ASTRONOMY AND ASTROPHYSICS↗

Benchmark specifications and data requirements for EBR-II shutdown heat removal tests SHRT-17 and SHRT-45R

Argonne National Laboratory’s (ANL) Experimental Breeder Reactor II (EBR-II) was a liquid metal reactor (LMR) with a sodium-bonded metallic fuel core that contributed very favorably to the reactor’s negative reactivity feedback. On June 20, 1984, a severe loss-of-flow test in the Shutdown Heat Removal Test (SHRT) series demonstrated the effectiveness of natural circulation in the EBR-II reactor. This test was SHRT-17 and at the beginning of the test the primary pumps were tripped at the same time as a full control rod insertion.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal enhancement cartridge heater modified tritium hydride bed development, Part 2 - Experimental validation of key conceptual design features

The Thermal Enhancement Cartridge Heater Modified (TECH Mod) tritium hydride bed is an interim replacement for the first generation (Gen1) process hydride beds currently in service in the Savannah River Site (SRS) Tritium Facilities. 3 new features are implemented in the TECH Mod hydride bed prototype: internal electric cartridge heaters, porous divider plates, and copper foam discs. These modifications will enhance bed performance and reduce costs by improving bed activation and installation processes, in-bed accountability measurements, end-of-life bed removal, and He-3 recovery. A full-scale hydride bed test station was constructed at the Savannah River National Laboratory (SRNL) in order to evaluate the performance of the prototype TECH Mod hydride bed. Controlled hydrogen (H{sub 2}) absorption/ desorption experiments were conducted to validate that the conceptual design changes have no adverse effects on the gas transfer kinetics or H{sub 2} storage/release properties compared to those of the Gen1 bed. Inert gas expansions before, during, and after H{sub 2} flow tests were used to monitor changes in gas transfer rates with repeated hydriding/de-hydriding of the hydride material. The gas flow rates significantly decreased after initial hydriding of the material; however, minimal changes were observed after repeated cycling. The data presented herein confirm that the TECH Mod hydride bed would be a suitable replacement for the Gen1 bed with the added enhancements expected from the advanced design features. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Utah FORGE Hydrothermal Friction-Hydraulic Transmissivity Laboratory Experiments

Submission includes data from laboratory slide-hold-slide tests, combined with flow through tests, conducted on Westerly granite with 30 degree sawcut. Tests were conducted with a constant confining pressure of 30 MPa with an average pore pressure of 10 MPa at temperatures of 23 and 200 degC. Three fluid flow conditions were examined (1) no flow, (2) cycled flow, and (3) continuous flow. Data were collected to asses the effect of temperature and pore fluid on frictional healing rates in granite at geothermal conditions. Data is available in XML and JSON data types.

15 GEOTHERMAL ENERGY↗