Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A method for generating quantitative vapor-phase infrared spectra of solids: results for phenol, camphor, menthol, syringol, dicyclopentadiene and naphthalene

Here, a method is presented to generate quantitative vapor-phase infrared spectra from substances that naturally occur as solids with moderate volatility. The solid is gravimetrically dissolved into a solvent that has few infrared spectral features, typically CS 2 and CCl 4 separately. The solution is flowed at a constant rate from a linearly pumped syringe into a metered stream of nitrogen carrier gas regulated by a mass flow controller. The analyte/solvent mix is flash vaporized by volatilizing the solution across a heated stainless-steel surface as it emanates from the syringe tip. The N 2 gas-solution mixture is flowed into a long-path White cell thermostatted at a desired temperature, the long optical path compensating for the modest analyte mixing ratio. A composite spectrum is generated from typically ten or more 760-Torr pressure-broadened spectra over the 600 to 6500 cm -1 spectral range at 0.1 cm -1 spectral resolution. The solid analytes reported here using this novel technique include dicyclopentadiene, menthol, syringol, phenol, camphor, and naphthalene.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanisms of Dynamic Near-Wake Modulation of a Utility-Scale Wind Turbine

The current study uses large eddy simulations to investigate the transient response of a utility-scale wind turbine wake to dynamic changes in atmospheric and operational conditions, as observed in previous field-scale measurements. Most wind turbine wake investigations assume quasi-steady conditions, but real wind turbines operate in a highly stochastic atmosphere, and their operation (e.g. blade pitch, yaw angle) changes constantly in response. Furthermore, dynamic control strategies have been recently proposed to optimize wind farm power generation and longevity. Therefore, improved understanding of dynamic wake behaviours is essential. First, changes in blade pitch are investigated and the wake expansion response is found to display hysteresis as a result of flow inertia. The time scales of the wake response to different pitch rates are quantified. Next, changes in wind direction with different time scales are explored. Under short time scales, the wake deflection is in the opposite direction of that observed under quasi-steady conditions. Finally, yaw changes are implemented at different rates, and the maximum inverse wake deflection and time scale are quantified, showing a clear dependence on yaw rate. To gain further physical understanding of the mechanism behind the inverse wake deflection, the streamwise vorticity in different parts of the wake is quantified. The results of this study provide guidance for the design of advanced wake flow control algorithms. The lag in wake response observed for both blade pitch and yaw changes shows that proposed dynamic control strategies must implement turbine operational changes with a time scale of the order of the rotor time scale or slower.

flow-structure interactions↗

Adhesion-force micro-scale study of desiccating granular material

Experiments on five-, four-, three- and two-wet-hydrophilic-grain clusters were performed to investigate evolution of adhesion of granular media during drying on the micro-scale. The experiments show that the adhesion-force of a cluster initially grows at most to three times the original value before decreasing to zero by the end of evaporation. The adhesion-force is composed of capillary pressure force acting over the liquid/solid contact surface area, and surface tension forces acting over the three-phase contact perimeter length. This is in contrast with most macro-scale phenomenological models, in which the only desaturation process variables affecting strength are suction and saturation. Both the contact surface area and contact perimeter length are reduced to zero upon complete liquid evaporation. The morphology of an evaporating water body evolves through slow flow controlled by evaporation rate, interrupted by various modes of fast air entry, which are non-equilibrium jumps of liquid/gas interfaces (Haines jumps). The instabilities involve large adhesion force discontinuities and substantial water mass reconfiguration with water flow in an extremely short time, which makes the process transient. The reconfigurations can reduce the original multi-grain water clusters to four-, three- and two-grain clusters by way of three different instability modes: of thin-sheet instability, or meniscus snap-through instability, depending on the sign of the Gauss curvature of the liquid surface, or finally, for two-grain bridges only, a liquid wire pinch-off. For larger meso-scale assemblies, however, the global adhesion-force evolution is little affected by the jumps. The air entries are potential sites for drying cracks. The (approximately) calculated capillary pressure for two- and three-grain clusters, in no cases is seen to reach high values, predicted from water retention curves.

Engineering↗

Disentangling the Influences of Storm-Relative Flow and Horizontal Streamwise Vorticity on Low-Level Mesocyclones in Supercells

Sufficient low-level storm-relative flow is a necessary ingredient for sustained supercell thunderstorms and is connected to supercell updraft width. Assuming a supercell exists, the role of low-level storm-relative flow in regulating supercells’ low-level mesocyclone intensity is less clear. One possibility considered in this article is that storm-relative flow controls mesocyclone and tornado width via its modulation of overall updraft extent. This hypothesis relies on a previously postulated positive correspondence between updraft width, mesocyclone width, and tornado width. An alternative hypothesis is that mesocyclone characteristics are primarily regulated by horizontal streamwise vorticity irrespective of storm-relative flow. A matrix of supercell simulations was analyzed to address the aforementioned hypotheses, wherein horizontal streamwise vorticity and storm-relative flow were independently varied. Among these simulations, mesocyclone width and intensity were strongly correlated with horizontal streamwise vorticity, and comparatively weakly correlated with storm-relative flow, supporting the second hypothesis. Accompanying theory and trajectory analysis offers the physical explanation that, when storm-relative flow is large and updrafts are wide, vertically tilted streamwise vorticity is projected over a wider area but with a lesser average magnitude than when these parameters are small. These factors partially offset one another, degrading the correspondence of storm-relative flow with updraft circulation and rotational velocity, which are the mesocyclone attributes most closely tied to tornadoes. In conclusion, these results refute the previously purported connections between updraft width, mesocyclone width, and tornado width, and emphasize horizontal streamwise vorticity as the primary control on low-level mesocyclones in sustained supercells.

54 ENVIRONMENTAL SCIENCES↗

Salt Vessel-Sample Generator Interface

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches for interfacing relevant unit operations with salt analysis to improve the timeliness and accuracy of sampling-based accountancy measurements. One technology under development is a vacuum sampler loop module. In this system, molten salt is drawn from a process vessel through a heated sampling line and into a charge vessel. Next, one or more samples are split from the volume in the charge vessel and the remaining salt is returned to the process. The vacuum sampler loop module is being developed to interface with other sample processing and analysis modules to enable rapid at-line sample characterization. The main purpose of the vacuum sampling loop module is to enable the collection of samples that are more representative of the bulk salt by replacing traditional point samplers (i.e., dip probes) with a sampling approach that captures a larger cross section of salt. Additionally, the vacuum sampling approach eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. Two methods of interfacing the vacuum sampling loop with a precision pneumatic sample generator were investigated in FY21. This report covers the testing of fluidic coupling between the two modules. Two iterations of the fluidically coupled modules were tested. The first iteration system coupled the two modules using a freeze valve to seal the vacuum sampler during filling and to control flow into the pneumatic sample generator. While this integrated system functioned as intended, some changes were implemented to make the system more robust and better suited to remote deployment. Specifically, the system was made to be more modular and active control of the vacuum filling operation was replaced with a passive control mechanism. For passive filling, the salt charge vessel was vented to a small gas tank that was at negative pressure, causing salt to be drawn into the vessel until the force of the fluid head was in equilibrium with the gas pressure. The passive control system performed well and will be used in future iterations. Another change in the second system was a newly configured pneumatic sample generator in which sample ejection occurred through a hole in the reservoir’s stainless-steel side wall instead of through a non-wetted sapphire orifice on the bottom. This alternate configuration may be better suited for near-process deployment because it enables on-line orifice maintenance and an orifice bypass drain back to the process. A third change in the second iteration system was the transition to a two-chamber charge vessel which split off a fraction of the sampled salt as a liquid aliquot. The goal was to create a buffer mechanism that would allow reproducible aliquoting of samples, independently of variability in the charge vessel fill height. While the two-chamber design was functional, the sample size reproducibility was below target values. To improve reproducibility and overcome many of the impediments to remote deployment of the vacuum sampling loop module, separate work was conducted to replace the two-chamber liquid aliquoting mechanism with aliquoting into single-use sample tubes. Solid salt transfer in the sample tubes will replace fluidic coupling for integrating the vacuum sampler with downstream modules. Because the proposed operations can all be executed with simple overhead actuation mechanisms or other existing hot-cell technology, there will be no need for large investments in novel hot cell sample handling technologies using this alternate approach. As such, near-term deployment of the vacuum sampling technology will be achievable. This new approach for automated coupling of sample tubes with down-stream modules is covered in a separate FY21 report, and a remotely operated version of the vacuum sampler loop module with the tube aliquoting feature is planned for FY22.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Microcontroller-based aerosol jet printer control software

This software is used with a microcontroller to control an aerosol jet printing system. It was written for a 32-bit ARM microcontroller, providing greater processing speed and complexity relative to more conventional low-cost printer controllers. The microcontroller software was written using a real-time operating system (FreeRTOS), which simplifies parallel operation of multiple functions and further customization. It supports simultaneous motion planning, pulse generation for stepper motors, reading encoder feedback, communicating with multiple mass flow controllers, controlling solid state relays, handling a software-based emergency stop, and sending data to the client PC. The program is written in C and communicates with the client PC via USB connection. Sandia National Laboratories is a multi-mission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2021-0436 O

Secor, EthanBenjamin↗

Collaborative Fault Tolerant Control of Non-Signalized Intersections for Connected and Autonomous Vehicles

With the potential of increased penetration of connected and autonomous vehicles (CAVs), intersectional signal control faces new challenges in terms of its operation and implementation. One possibility is to fully make use of the communication capabilities of CAVs so that intersectional signal control can be realized by CAVs alone – this leads to non-signalized intersectional operation for traffic networks in urban areas. In this paper, the state-of-the-art on collaborative fault tolerant control schemes for complex systems will be briefly described. This is then followed by the formulation of operational fault tolerant control that realizes the collaborative fault tolerance functionality at CAVs operational level in response to possible individual vehicle faults, where detailed modelling using vehicle movement dynamics will be described together with the construction of fast fault diagnosis and a collaborative fault tolerant control algorithm. A simple example will be given as well to demonstrate the proposed algorithm together with the discussions on other issues such as randomness of the system, communication errors and full energy consideration. These leads to several future directions of the research for the traffic flow control of non-signalized intersections with 100% penetration of CAVs.

Wang, Hong↗

Flash Freeze Flow Tube to Vitrify Aerosol Particles at Fixed Relative Humidity Values

Development of methods to measure the phase transitions and physical properties of submicron atmospheric aerosol particles is needed to better model these systems. Here, we introduce a method to flash freeze submicron particles to measure phase transitions as a function of relative humidity (RH). Particles are equilibrated at a fixed RH, vitrified in a temperature-controlled flow tube, and imaged with cryogenic transmission electron microscopy (cryo-TEM). We demonstrate the use of the technique for measuring the efflorescence relative humidity (ERH) of potassium sulfate and potassium chloride aerosol as well as the separation RH for a multicomponent organic/inorganic system that undergoes liquid-liquid phase separation (LLPS). The location of phase transitions can shift between the micrometer and nanometer size regimes and particles in a given population may have a range of RH over which a phase transition occurs. This technique addresses these requirements by allowing for characterization of the phase transitions for individual particles in a population on the submicron scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Particle Flow Distribution in a Fluidized-Particles Multitube Solar Receiver

A fluidized-particles two-tube solar receiver was tested at ambient temperature at PROMES Laboratory to investigate the influence of an inhomogeneous solar flux density on the particle mass flow rate between the tubes. The principle of this 3rd generation solar receiver is to fluidize the particles in a container, called dispenser, in which the tubes’ bottom are immersed. The fluidized particles are flowing upward the tubes by applying an overpressure in the dispenser. Air velocities are changed inside the tubes, thanks to air mass flow controllers, to represent temperature heterogeneity between the tubes. Air velocities from 0.05 up to 0.52 m/s were tested, both in homogeneous and heterogeneous conditions. In the heterogeneous ones, the differences in air velocity between the tubes aim to mimic a difference in temperature from 20 to 100 % with homogeneous air flow rates injected. The following conclusions were drawn. First, the particle mass flux in the tubes are the same with homogeneous air velocities, each one following a calibration map previously obtained. Second, different air velocities lead to different particle mass flux. Third, the rise of the total particle mass flux diminishes the pressure in the dispenser. Four, this diminution of pressure leads to a decrease of the particle mass flow rate of the tube with the lower air velocity. This influence can lead in some cases to the stop of the fluidized bed circulation in the affected tube.

Sahuquet, Guillaume (ORCID:0000000302752890)↗

Thermal Integration of DETAIL Systems

A thermal connection between the Microreactor AGile Non-nuclear Experimental Testbed (MAGNET) and the thermal energy distribution system (TEDS) has been a key part of the Dynamic Energy Transport and Integration Laboratory (DETAIL) plan since the development of the Integrated Energy Systems Roadmap in 2020. This connection provides an expanding demonstration capability for integrated system operations. The thermal connection between MAGNET and TEDS required the selection of a heat exchanger and valves to isolate flow. Research staff within the NEET Crosscutting Technology Development program selected equipment after receiving proposals from multiple vendors. A helical coil heat exchanger from Graham Corporation was selected for its small volume relative to its heat transfer surface area to fit in the limited space available. Triple offset butterfly valves with pneumatic actuators from Flowserve were selected to isolate and/or control flow of the hot gas through the heat exchanger. Staff from Idaho National Laboratory’s (INL) Facilities and Site Services Engineering department designed the piping and structural support. A mechanical construction firm was contracted to install the system. This report documents the design and construction of this thermal connection.

25 ENERGY STORAGE↗

Refueling water storage tank (RWST) with tailored passive emergency core cooling (ECC) flow

A nuclear reactor comprises a pressure vessel containing a nuclear reactor core. A reactor core cooling system comprises a standpipe including a plurality of orifices in fluid communication with a refueling water storage tank (RWST) to drain water from the RWST into the standpipe, and an injection line configured to drain water from the standpipe to the pressure vessel. In some embodiments the standpipe is disposed in the RWST, while in other embodiments the standpipe is disposed outside of the RWST and cross-connection pipes connect the plurality of orifices with the RWST. The reactor core cooling system may further comprise a valve configured to control flow through one orifice of the plurality of orifices in fluid communication with the RWST based on water level in the standpipe. The valve may comprise a float valve having its float disposed in the standpipe.

Watson, Ronald C.↗

Hydrogen Leak Modeling for Development of Smart Distributed Monitoring Under Unintended Releases

Hydrogen is a versatile and clean energy carrier that can be produced from various renewable sources such as wind, solar, and hydropower. Hydrogen has the potential to play a crucial role in decarbonizing industrial processes that are currently reliant on fossil fuels and provide long-duration and/or seasonal energy storage to enable electricity decarbonization. Hydrogen can also be used as a fuel for fuel cell vehicles, providing a zero-emission alternative to traditional internal combustion engines. DOE launched the Hydrogen Energy Earthshot (Hydrogen Shot) in June 2021 to reduce the cost of clean hydrogen by 80% to $1 per 1 kilogram in 1 decade ("1 1 1"). While promising, Hydrogen is highly-flammable, and in the presence of oxygen, it can form explosive mixtures. . Therefore, understanding leak scenarios is essential to evaluate and mitigate the safety risks associated with potential hydrogen leaks. An increased understanding of leak behavior, and having tools to model leaks, can help assess how hydrogen would disperse in different environments, influencing emergency response plans and safety measures, and identify potential issues with materials and design systems that can withstand the challenges posed by hydrogen. Recently, researchers have attempted to study hydrogen leaks for development of risk management strategies. However, the focus has been on closed or semi-closed spaces like storage rooms, vehicles, garages, and fueling stations - all promising locations for future hydrogen infrastructure. In this presentation, the modeling environment extends the span of research further by modeling hydrogen leak in an outdoor, open space. We will present the key challenges with modeling hydrogen leaks in an uncontrollable environment, how they were handled, and how modeling results informed sensor selection and placement. A Hydrogen research facility at the National Renewable Energy Laboratory (NREL) was used as a case study to model hydrogen leaks. In the future, Hydrogen wide area detection methodologies will be developed and tested at this site to monitor for unintended and operational hydrogen releases. The data generated from modeling will be used to develop a predictive model to detect hydrogen leak location based on concentration measured by sensors in this open space. Furthermore, the facility was also chosen because controlled hydrogen releases can be performed. A computational fluid dynamics (CFD) based modeling approach was taken to model hydrogen leak. The full-scale hydrogen facility was modeled with a large ambient domain. The electrolyzer at the facility can produce a controlled release rate of 27 kg-H2/hr. Site-specific atmospheric and weather condition data such as wind direction, wind speed at various altitudes, and temperature were used as inputs to the model. To capture the variability of weather conditions, a subset of the weather conditions experienced during daytime hours without precipitation over the course of three months was generated; using established data clustering techniques, a total of 100 condition sets were chosen. The results show statistical distributions and ranges of hydrogen concentrations at locations throughout the domain. These distributions are compared to experimental data from a constant mass flow, controlled hydrogen release at the facility. The stochastic wind conditions of the release make direct validation difficult, therefore, statistical comparison approaches were used. Wind conditions are found to significantly impact the release behavior, including direction and concentration. Sensor selection and placement is proposed for the facility and is now based on release behavior predicted for the facility given its weather patterns; this is much more informed than without the modeling results. The methodology and analysis procedure can be translated to other facilities using modified geometries and site-specific weather conditions. Hydrogen holds great promise as a renewable energy fuel, but ensuring safety in its production, storage, and use is paramount. Studying potential leak scenarios in an open space will help develop sensors to detect hydrogen on a large spectrum of concentration and eventually build a smart distributed monitoring system.

CFD↗

Potential-induced wetting and dewetting in hydrophobic nanochannels for mass transport control

Wetting and dewetting transitions play a central role in controlling the hydrophobicity of the lining of biological channels in order to regulate aqueous solution permeation. Understanding of the operational characteristics of biological nanochannels led to experimental efforts to mimic their behavior and to achieve potential-induced, repeatedly-switchable wettability transitions in synthetic nanochannels in the early 2010s. Since then, research has identified conditions needed to produce reversible wettability transitions using a number of different environmental stimuli - such as light, pH, and electrostatic charge - in addition to potential. Furthermore, nascent understanding of the underlying phenomena in synthetic nanochannels was rapidly followed by practical applications, including oil-water separations, drug release, and electroactive flow control based on switchable wettability. Furthermore, more practical applications are being developed continuously, as the physical and chemical principles that govern hydrophobic gating at the nanoscale are further elucidated, making it possible to exploit wettability as a design element in nanofluidic systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS-based on real-time optimal power flow-controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization techniques in self-similar compressible flow

We investigate the one-dimensional (1D) inviscid compressible flow equations for an ideal gas through the lens of optimization techniques. It is the case that, to our knowledge, optimization analysis applied to the so-called “linear velocity” solutions of the Euler compressible flow equations has not been previously conducted. Through both gradient-based and variational techniques, new variants of well-studied flow scenarios, i.e., self-similar, 1D, linear velocity solution class to idealized inviscid compressible flow equations, are determined, as encoded in both the kinematic and thermodynamic properties of this self-similar solution class. With the kinematics of the said solutions being driven by a self-similar “scale radius” and the thermodynamics being driven separately through the appearance of an arbitrary function, a myriad of new solution classes is possible. Acting as a guide to more realistic physical circumstances as well as discovery, it is the hope that the presented cases serve as the framework for future investigations into the intersection of self-similarity and optimization techniques. Fields of study that may find this work to be of interest include aerodynamic design, flow control, inertial confinement fusion, physics-informed neural networks, and other related areas of interest.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources: Preprint

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS—based on real-time optimal power flow—controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

61 RADIATION PROTECTION AND DOSIMETRY↗

Technology Enabling Zero-EPZ Micro Modular Reactors: Fabrication of Zirconium Hydride with Controlled Hydrogen Loading

This report completes Milestone M2.2.2 - ZrH pellet fabricated with controlled hydride loading: ZrH1.5±0.1 single phase pellets fabricated with controlled and thermally stable hydride loading. Hydrogen content to be quantified and single-phase confirmed by X-ray diffraction. In this milestone, we report the successful fabrication of delta-phase zirconium hydride pellets using the ORNL bulk metal hydriding system. The successful deployment of zirconium hydride moderator in advanced reactors requires development of a consistent and affordable production pathway along with implementation of a hydrogen retention solution throughout the reactor life. Fabrication of delta-phase zirconium hydride is challenging since the absorption of a large amount of hydrogen into alpha-zirconium induces significant volume expansion and the present hydrogen concentration gradient results in cracking. A fully programmable hydriding system with continuous hydrogen partial pressure and flow control to facilitate processing of massive metal hydride has been developed at ORNL. In this report, the working principle of the hydriding system will be introduced. Characterization of the produced zirconium hydride includes X-ray powder diffraction to identify the present phases and X-ray Computed Tomography to visualize the internal microstructure (including cracks). The results indicate that single delta-phase zirconium hydride pellets with various sizes have been successfully produced.

36 MATERIALS SCIENCE↗

Distributed Detection of Malicious Attacks on Consensus Algorithms with Applications in Power Networks

Consensus-based distributed algorithms are well suited for coordination among agents in a cyber-physical system. These distributed schemes, however, suffer from their vulnerability to cyber attacks that are aimed at manipulating data and control ow. In this article, we present a novel distributed method for detecting the presence of such intrusions for a distributed multi-agent system following ratio consensus. We employ a Max-Min protocol to develop low cost, easy to implement detection strategies where each participating node detects the intrusion independently, eliminating the need for a trusted certifying agent in the network. The effectiveness of the detection method is demonstrated by numerical simulations on a 1000 node network to demonstrate the efficacy and simplicity of implementation.

27 ARPA - Advanced Research Projects Agency-Energy↗