Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flexible generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Stable Co-valorization of Carbon Dioxide and Methane via Dynamic Reconstruction of a Metal Oxide Solid Solution Catalyst

Dry reforming of methane (DRM) is a process that converts two greenhouse gases (methane and carbon dioxide) into syngas, a mixture of H 2 and CO, that can lead to a variety of value-added chemicals. Owing to its endothermic nature, high reaction temperatures up to 800 °C are typically required and the grand challenge lies in developing robust catalysts without sintering and coking-induced deactivation during the long-term on-stream operation. Towards this aim, herein, a robust complex oxide-supported NiCu alloy catalyst was generated in situ during DRM. By leveraging the configurational stability of a solid oxide solution precursor, tightly anchored NiCu bimetallic nanoparticles were in situ exsoluted and acted as the active sites in DRM. The as-afforded catalyst exhibited stable performance for DRM due to the ability to repel coke off the surface as the reaction proceeds. Kinetic experiments along with top surface characterization detail the reconstruction behavior of the solid oxide solution under DRM reaction conditions. In conclusion, the fundamental insights from this work provide guidance on generating resistant and flexible catalysts via in situ active sites formation from easily synthesized metal oxide solid solutions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The role of focusing geometry in MeV x-ray production from petawatt laser–solid interaction

Relativistic laser–plasma interactions provide a compact and flexible route to generating bright, ultrashort pulses of MeV x rays, with applications in high-energy density science, nuclear physics, and radiography. Despite extensive study of intensity scaling in laser-driven electron acceleration, the role of focusing geometry and focal-volume effects in MeV radiation production remains insufficiently understood. Here, we present experimental and kinetic simulation results from the Texas Petawatt Laser (120 J, 140 fs) in which the focusing geometry (f/3 or f/1.5) is varied, while the laser energy and pulse duration are fixed. Experimentally, the f/3 geometry produces approximately three times more MeV radiation than the f/1.5 geometry, despite its twofold lower nominal vacuum intensity. This result is based on the time-integrated radiation per unit solid angle, as measured along the diagnostic line of sight. Three-dimensional particle-in-cell simulations reproduce this trend when a modest (10s of μm) effective focal plane shift is introduced, demonstrating that relativistic laser–plasma coupling is highly sensitive to focal geometry in the presence of a preplasma. This behavior is consistent with differences in interaction length and effective intensity at the critical surface between the two configurations. The sensitivity of the tightly focused f/1.5 configuration ($z_R ≈$⁠ 5 μ m) reflects the combined influence of thermal lensing and an extended preplasma, while the f/3 geometry (⁠$z_R ≈$ 80 μ m) remains comparatively robust. These results demonstrate a breakdown of conventional intensity scaling and identify focusing geometry as a critical control parameter for MeV electron and x-ray generation at petawatt powers. Implications for laser–plasma-based radiographic facilities are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SAM Two-Phase Flow Model Development and Applications for Operational Transients in Advanced Reactors

As advanced nuclear technologies continue to develop, the need for the flexible operation and generation of these advanced reactors becomes necessary to maximize economic potential. As large-scale experiments are not always feasible, modeling and simulations of advanced reactors play a crucial role in design optimization and analysis. The SAM (System Analysis Module) code developed at Argonne National Laboratory is a state-of-the-art system-level thermal-hydraulic code aimed at simulating advanced reactor systems. Recent code developments have implemented two-phase flow modeling using the homogeneous equilibrium model, and a new steam generator component has been developed to utilize the two-phase flow implementation. In addition to verification tests, a load-following simulation was performed to model a realistic load-following transient in a proposed integrated system consisting of a conceptual advanced reactor known as the Advanced Burner Test Reactor (ABTR) and thermal energy storage (TES) tanks. The integrated system model uses two large TES tanks designed for sodium and a model helical coil steam generator to simulate the operational load-following transient. The flow rates of the feedwater and secondary loops are regulated to meet a prescribed steam generator load consistent with the electricity demand over a 24-h period. In conclusion, the results found the ABTR system was able to maintain stable reactor conditions and primary- and secondary-side characteristics over the course of the load-following transient.

Advanced Burner Test Reactor (ABTR)↗

Distribution Operations: The Evolution of Distributed Energy Resources [Guest Editorial]

Utilities around the world are experiencing change with the increasing digitalization of their systems and those of their customers. Efforts to decarbonize the electric power system have led to growth in renewable energy resources, particularly distributed energy resources (DERs), such as generation, storage, and flexible load, both in front of and behind the meter. As this change occurs in any given utility service area, new tools, such as advanced distribution management systems (ADMSs), are needed to manage utility operations, planning, and business issues, some of which are discussed here.

distributed energy resources, DER, decarbonize, re↗

The Value of Increased HVDC Capacity Between Eastern and Western U.S. Grids: The Interconnections Seam Study

The Interconnections Seam Study examines the potential economic value of increasing electricity transfer between the Eastern and Western Interconnections using high-voltage direct-current (HVDC) transmission and cost-optimizing both generation and transmission resources across the United States. The study conducted a multi-model analysis that used co-optimized generation and transmission expansion planning and production cost modeling. Four transmission designs under eight scenarios were developed and studied to estimate costs and potential benefits. The results show benefit-to-cost ratios that reach as high as 2.9, indicating significant value to increasing the transmission capacity between the interconnections under the cases considered, realized through sharing generation resources and flexibility across regions.

13 HYDRO ENERGY↗

Integrated Heat Pump Thermal Storage and Power Cycle for CSP (Final Technical Report)

Pumped thermal energy storage (PTES) is a storage system that stores electricity in thermal reservoirs. In this project, methods of integrating PTES with concentrating solar power (CSP) systems were investigated and their feasibility evaluated. Hybrid "solar-PTES" devices can provide both flexible renewable power generation as well as a variety of electricity storage services. Techno-economic models of PTES and solar-PTES were developed and used to assess their performance, cost, and commercial viability. Systems were optimized using multi-objective optimization techniques. The value that these storage devices provide to the grid was estimated using production cost modelling. Key advances made in this project include the development of detailed techno-economic models that improve state-of-the-art assessments of these technologies. Off-design models were developed and used in grid-analysis models. This work describes for the first time how PTES and solar-PTES behave over a range of operating points and assesses the value that these systems can provide to the electrical grid. Feedback was obtained from experts in the field, which clarified key technological and economic barriers that must be addressed to improve the feasibility of these devices.

14 SOLAR ENERGY↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shifting in Large Offices

This documentation focuses on a single end-use savings shape measure - thermostat control for load shifting. The thermostat control for load shifting measure applies heating and cooling temperature setpoint adjustment for pre-conditioning before the peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start time of the peak window, and then adjusts the thermostat cooling or heating setpoints by a specified offset value from original schedules to precool or preheat the space , for a specified length of time before the start of peak window, and thus shifts load in the peak window to the pre-conditioning period. The measure is flexible and allows users to adjust the heating and cooling offset values and length of pre-conditioning period, but for this study, the load shifting strategy is applied as pre-cooling only (adjusting only cooling setpoints). The default adjustment for cooling setpoints is set to -1 degrees Celsius , and the default duration of pre-cooling is 1 hour. This measure is applicable to large offices equipped with electric HVAC system, which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shifting measure demonstrates -1% daily peak demand reduction and 0% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Designing Operationally Flexible Diafiltration Membrane Systems for Critical Mineral Separations

This talk presents the design of operationally flexible diafiltration membrane systems for Li/Co recovery, and applies robust optimization methodologies using these flexible systems to generate optimal designs immune to membrane manufacturing variability and uncertain process inlet conditions. The results highlight the use of robust optimization to find design strategies and insights that may reduce technical risks arising from model uncertainties.

Yao, Jason↗

Treatment and Mineral Recovery from Combustion Residual Leachate and Produced Water

This talk presents the design of operationally flexible diafiltration membrane systems for Li/Co recovery, and applies robust optimization methodologies using these flexible systems to generate optimal designs immune to membrane manufacturing variability and uncertain process inlet conditions. The results highlight the use of robust optimization to find design strategies and insights that may reduce technical risks arising from model uncertainties.

Able, Chad↗

Distribution Grid Model Publication Investigation

Interest in the external exchange of distribution grid model data is growing around the world, driven largely by the challenges and opportunities presented by the increasing amount of generation, storage, and flexible load being embedded within the distribution grid. This report provides an overview of the current state of distribution grid model data sharing, with a focus on the industry-leading activities currently underway in Great Britain (GB). A second report will explore opportunities for external distribution grid model sharing in the United States.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ComStock Measure Documentation: Lighting Control for Load Shedding

This report describes the modeling methodology for a single end-use savings shape measure - lighting control for load shedding - and briefly introduces key results. The lighting control for load shedding measure applies lighting dimming control to reduce the lighting load during the building's electricity peak window every weekday. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the predicted peak window, and then adjusts the lighting dimming level by a percentage reduction from the original schedules during the peak window to reduce the peak demand. The measure is applicable to (large, medium and small) offices, warehouses, and primary and secondary schools, which correspond to approximately 68% of the stock floor area of commercial buildings in ComStock analysis. The measure demonstrates 2%-7% daily peak demand reduction performance for applicable buildings, and 0.43% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Thermostat and Lighting Control for Load Shedding

This report describes the modeling methodology for an upgrade package of two end-use savings shape measures - Thermostat Control for Load Shedding and Lighting Control for Load Shedding - and briefly introduces key results. The package combines thermostat control for load shedding and lighting control for load shedding measures to reduce the HVAC and lighting load during the building's electricity peak window every weekday. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the predicted peak window, and then relaxes the thermostat setpoints and dims the lighting level from the original schedules during the peak window to reduce the peak demand. The measure is applicable to (large, medium and small) offices, warehouses, and primary and secondary schools, which correspond to approximately 68% of the stock floor area of commercial buildings in ComStock analysis. The measure demonstrates 3%-10% daily peak demand reduction performance for applicable buildings, and 0.97% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SICOPOLIS-AD v1: an open-source adjoint modeling framework for ice sheet simulation enabled by the algorithmic differentiation tool OpenAD

We present a new capability of the ice sheet model SICOPOLIS that enables flexible adjoint code generation via source transformation using the open-source algorithmic differentiation (AD) tool OpenAD.The adjoint code enables efficient calculation of the sensitivities of a scalar-valued objective function or quantity of interest (QoI) to a range of important, often spatially varying and uncertain model input variables, including initial and boundary conditions, as well as model parameters.Compared to earlier work on the adjoint code generation of SICOPOLIS, our work makes several important advances:(i) it is embedded within the up-to-date trunk of the SICOPOLIS repository – accounting for 1.5 decades of code development and improvements – and is readily available to the wider community;(ii) the AD tool used, OpenAD, is an open-source tool;(iii) the adjoint code developed is applicable to both Greenland and Antarctica, including grounded ice as well as floating ice shelves, with an extended choice of thermodynamical representations.A number of code refactorization steps were required. They are discussed in detail in an Appendix as they hold lessons for the application of AD to legacy codes at large.As an example application, we examine the sensitivity of the total Antarctic Ice Sheet volume to changes in initial ice thickness, austral summer precipitation, and basal and surface temperatures across the ice sheet.Simulations of Antarctica with floating ice shelves show that over 100 years of simulation the sensitivity of total ice sheet volume to the initial ice thickness and precipitation is almost uniformly positive, while the sensitivities to surface and basal temperature are almost uniformly negative. Sensitivity to austral summer precipitation is largest on floating ice shelves from Queen Maud to Queen Mary Land. The largest sensitivity to initial ice thickness is at outlet glaciers around Antarctica. Comparison between total ice sheet volume sensitivities to surface and basal temperature shows that surface temperature sensitivities are higher broadly across the floating ice shelves, while basal temperature sensitivities are highest at the grounding lines of floating ice shelves and outlet glaciers. A uniformly perturbed region of East Antarctica reveals that, among the four control variables tested here, total ice sheet volume is the most sensitive to variations in austral summer precipitation as formulated in SICOPOLIS.Comparison between adjoint- and finite-difference-derived sensitivities shows good agreement, lending confidence that the AD tool is producing correct adjoint code.The new modeling infrastructure is freely available at http://www.sicopolis.net (last access: 2 April 2020) under the development trunk.

58 GEOSCIENCES↗

Going beyond BEM with BEM: an insight into dynamic inflow effects on floating wind turbines

Blade element momentum (BEM) theory is the backbone of many industry-standard wind turbine aerodynamic models. To be applied to a broader set of engineering problems, BEM models have been extended since their inception and now include several empirical corrections. These models have benefitted from decades of development and refinement and have been extensively used and validated, proving their adequacy in predicting aerodynamic forces of horizontal-axis wind turbine rotors in most scenarios. However, the analysis of floating offshore wind turbines (FOWTs) introduces new sets of challenges, especially if new-generation large and flexible machines are considered. In fact, due to the combined action of wind and waves and their interaction with the turbine structure and control system, these machines are subject to unsteady motion and thus unsteady inflow on the wind turbine's blades, which could put BEM models to the test. Consensus has not been reached on the accuracy limits of BEM in these conditions. This study contributes to the ongoing research on the topic by systematically comparing four different aerodynamic models, ranging from BEM to computational fluid dynamics, in an attempt to shed light on the unsteady aerodynamic phenomena that are at stake in FOWTs and whether BEM is able to model them appropriately. Simulations are performed on the UNAFLOW 1:75 scale rotor during imposed harmonic surge and pitch motion. Experimental results are available for these conditions and are used for baseline validation. The rotor is analyzed in both rated operating conditions and low wind speeds, where unsteady aerodynamic effects are expected to be more pronounced. Results show that BEM, despite its simplicity, can adequately model the aerodynamics of FOWTs in most conditions if augmented with a dynamic inflow model.

17 WIND ENERGY↗

Understanding Economic and Deployment Benefits of Wind-PV Hybrid Power Plants

The least-cost approach to decarbonizing the U.S. electricity supply will likely involve a significantly expanded share of variable renewable energy (VRE) generation. Many strategies and approaches have been identified to address integration challenges in a VRE-dominated system, including standalone and coupled battery systems. In this study, we explored the current and future potential of utility-scale hybrid energy systems comprising PV, wind, and lithium-ion battery technologies (PV-wind-battery systems). Analysis results include temporal complementarity of wind and PV resources across the contiguous United States, with an emphasis on metrics that quantify reductions in variability that can be achieved through hybridization. We further use a price-taker model with simulated hourly energy and capacity prices to determine the revenue-maximizing dispatch of a range of PV-wind-battery configurations across Texas, from the present through 2050. We find that coupling PV, wind, and battery technologies allows for more effective utilization of interconnection capacity by increasing capacity factors to 60-80%+ and capacity credits to close to 100%, depending on battery capacity. We also compared the energy and capacity values of PV-wind and PV-wind-battery systems to the corresponding stability coefficient metric, which describes the location-and configuration-specific complementarity of PV and wind resources. Our results show that the stability coefficient effectively predicts the configuration-location combinations in which a smaller battery component can provide comparable economic performance in a PV-wind-battery system (compared to a PV-battery system). These PV-wind-battery hybrids can help integrate more VRE by providing smoother, more predictable generation and greater flexibility. Finally, capacity expansion modeling of PV-wind systems indicates that hybridization can reduce transmission expansion requirements associated with a heavily decarbonized U.S. electricity system.

complementarity↗

Summary of INL Integrated Energy Systems Research for the Global National Laboratories Consortium on IES

The DOE Office of Nuclear Energy (DOE-NE) program on Integrated Energy Systems (IES) is led by researchers at Idaho National Laboratory (INL), and work is conducted in partnership with an array of other DOE laboratories, industry, and academia. IES research and development activities are additionally complimented by the DOE-NE Light Water Reactor Sustainability (LWRS) program, where work under the Flexible Plant Operations & Generation pathway supports analysis of opportunities for non-electric applications of current fleet nuclear plants and collaborates with multiple plants on near-term hydrogen production demonstration opportunities. The DOE-NE programs additionally partner with the Hydrogen and Fuel Cell Technologies Office under the DOE Office of Energy Efficiency and Renewable Energy to jointly fund the development of analysis tools, technologies, and nuclear-integrated hydrogen demonstration projects. This document provides a brief, high-level summary of IES work as contribution to the annual report for the Global National Laboratories Consortium on IES.

08 HYDROGEN↗

FORCE Regression Testing

Via programs including the Light Water Reactor Sustainability and Integrated Energy Systems, the U.S. Department of Energy has invested in the Framework for Optimization of ResourCes and Economics (FORCE) software framework (Idaho National Laboratory 2024a) for the technical and economic analysis of nuclear-integrated energy systems (IES). Nuclear IES expand the use of nuclear from traditional baseload electricity generation to a flexible and adaptive source of combined heat and power. Nuclear heat can be used in the production of a variety of energy currencies such as hydrogen and ammonia as well as other heat applications including water desalination and district heating. FORCE is designed with the intent to provide interconnected analysis tools that enable the accurate technical and economic assessment of specific nuclear IES configurations for individual energy markets. FORCE consists of three main analysis pathways: HYBRID (Idaho National Laboratory 2024b), which contains high-resolution physical models for IES; Holistic Energy Resource Optimization Network (HERON) (Idaho National Laboratory 2024c), which analyzes IES long-term economic viability; and Optimization of Real-time Capacity Allocation (ORCA) (Idaho National Laboratory 2024d), designed for real-time control of IES via digital twins and optimal decision making, including autonomous and remote operation research. Development of the FORCE ecosystem is guided by three pillars: capability, which assures that the computational requirements of IES analysis are met by the software tools; reliability, which provides for consistent code performance and expected behaviors; and accessibility, which lowers the barrier to entry for using the software and accelerates analysis by users beyond the FORCE primary developers. Reliability of the FORCE ecosystem is established according to the American Nuclear Society?s Nuclear Quality Assurance (NQA-1) program [American Society of Mechanical Engineers 1982], with specific levels of software quality assurance (SQA) within NQA-1 applied to each software tool in FORCE. As the tools within FORCE have matured, some integration algorithms to accurately connect the software tools for holistic analysis have been developed and deployed within the FORCE software repository. In accordance with NQA-1 standards, regression tests are required to guarantee the software performs consistently even when new capabilities are added to the software. In this report, we document the deployment of both unit tests, which test the consistent behavior of small pieces of the FORCE code base, as well as integration tests, which test the consistent performance of full use cases for the FORCE integration algorithms. We further document the encapsulation of these tests within a test harness, which collectively checks for each successful test completion on demand. Finally, we document the automation of the test harness using GitHub Actions [GitHub 2024], which require all tests succeed before any new capability or other changes can be added to the FORCE integration software

97 MATHEMATICS AND COMPUTING↗

A Rapid Procedure Development Approach for Multi-stage Validation of Novel Nuclear Power Plant Systems

The integration of renewable energy sources into the modern grid introduces variability in generation, challenging nuclear reactors to remain economically viable amid low wholesale electricity prices. To address this, Idaho National Laboratory?s Flexible Plant Operation and Generation program explores alternative revenue streams, including commoditizing excess thermal energy. A Thermal Power Dispatch (TPD) system enables steam extraction from the secondary loop for industrial uses like hydrogen production via high-temperature steam electrolysis.

99 - GENERAL AND MISCELLANEOUS↗