Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fire modelling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Assessment of risk due to the use of carbon fiber composites in commercial and general aviation

The development of a national risk profile for the total annual aircraft losses due to carbon fiber composite (CFC) usage through 1993 is discussed. The profile was developed using separate simulation methods for commercial and general aviation aircraft. A Monte Carlo method which was used to assess the risk in commercial aircraft is described. The method projects the potential usage of CFC through 1993, investigates the incidence of commercial aircraft fires, models the potential release and dispersion of carbon fibers from a fire, and estimates potential economic losses due to CFC damaging electronic equipment. The simulation model for the general aviation aircraft is described. The model emphasizes variations in facility locations and release conditions, estimates distribution of CFC released in general aviation aircraft accidents, and tabulates the failure probabilities and aggregate economic losses in the accidents.

Fiksel, J.↗

Deep Learning Provides Substantial Improvements to County‐Level Fire Weather Forecasting Over the Western United States

Abstract The recent wildfires in the western United States during 2018 and 2020 caused record‐breaking fire damage and casualties. Despite remarkable advances in fire modeling and weather forecasting, it remains challenging to anticipate catastrophic wildfire events and associated damage. One key missing component is a fire weather prediction system with sufficiently long lead time capable of providing useful regional details. Here, we develop a hybrid prediction model of wildfire danger called CFS with super resolution (CFS‐SR) as a proof of concept to fill that void. The CFS‐SR model is constructed by integrating the Climate Forecast System version 2 with a deep learning (DL) technique from Single Image Super Resolution, a method widely used in enhancing image resolution. We show that for the 2018–2019 fire season, the CFS‐SR model significantly improves accuracy in forecasting fire weather at lead times of up to 7 days with an enhanced spatial resolution up to 4 km. This level of high resolution provides county‐level fire weather forecast, making it more practical for allocating resources to mitigate wildfire danger. Our study demonstrates that a proper combination of ensemble climate predictions with DL techniques can boost predictability at finer spatial scales, increasing the utility of fire weather forecasts for practical applications.

54 ENVIRONMENTAL SCIENCES↗

Physics-Informed AI for Climate and Weather Risk Prediction (Final Report)

As part of the work Terrafuse developed 1) a model for wildfire risk in California, and 2) a model for downscaled wind fields from Numerical Weather Prediction (NWP) numerical models. The wildfire model is based on 20 years of historical data and captures the dependence of wildfire incidence and spread on climatic, weather and land-use variables by training a machine learning model. Nonlinear relationships between input features are learned and expressed by the model and model transparency allows features to be ranked and interpreted. The fire model is of use for accurately predicting real-time daily and long-term wildfire risk for use cases in energy and insurance. The downscaled wind model is a spatio-temporal deep learning model that emulates the influence of high-resolution variables on wind speed, allowing coarse-resolution operational NWP models to be accurately expressed on fine grids at high resolution, with application to wind energy and weather forecasting.

54 ENVIRONMENTAL SCIENCES↗

The Annular Suspension and Pointing System /ASPS/

The Annular Suspension and Pointing System (ASPS) may be attached to a carrier vehicle for orientation, mechanical isolation, and fine pointing purposes applicable to space experiments. It has subassemblies for both coarse and vernier pointing. A fourteen-degree-of-freedom simulation of the ASPS mounted on a Space Shuttle has yielded initial performance data. The simulation describes: the magnetic actuators, payload sensors, coarse gimbal assemblies, control algorithms, rigid body dynamic models of the payload and Shuttle, and a control system firing model.

Anderson, W. W.↗

Estimating canopy fuel characteristics for predicting crown fire potential in common forest types of the Atlantic Coastal Plain, USA

We computed four stand-level canopy stratum variables important for crown fire modelling – canopy cover, stand height, canopy base height and canopy bulk density – from forest inventory data. We modelled the relationship between the canopy variables and a set of common inventory parameters – site index, stem density, basal area, stand age or stand height – and number of prescribed burns. We used a logistic model to estimate canopy cover, a linear model to estimate the other canopy variables, and the information theoretic approach for model selection. Coefficients of determination across five forest groups were 0.72–0.91 for stand height, 0.36–0.83 for canopy base height, 0.39–0.80 for canopy cover, and 0.63–0.78 for canopy bulk density. We assessed crown fire potential (1) for several sets of environmental conditions in all seasons, and (2) with increasing age, density and number of prescribed burns using our modelled canopy bulk density and canopy base height variables and local weather data to populate the Crown Fire Initiation and Spread model. Results indicated that passive crown fire is possible in any season in Atlantic coastal plain pine stands with heavy surface fuel loads and active crown fire is most probable in infrequently burned, dense stands at low fuel moistures.

Forestry↗

Application of the NUREG/CR-6850 EPRI/NRC Fire PRA Methodology to a DOE Facility

The application NUREG/CR-6850 EPRI/NRC fire PRA methodology to DOE facility presented several challenges. This paper documents the process and discusses several insights gained during development of the fire PRA. A brief review of the tasks performed is provided with particular focus on the following: • Tasks 5 and 14: Fire-induced risk model and fire risk quantification. A key lesson learned was to begin model development and quantification as early as possible in the project using screening values and simplified modeling if necessary. • Tasks 3 and 9: Fire PRA cable selection and detailed circuit failure analysis. In retrospect, it would have been beneficial to perform the model development and quantification in 2 phases with detailed circuit analysis applied during phase 2. This would have allowed for development of a robust model and quantification earlier in the project and would have provided insights into where to focus the detailed circuit analysis efforts. • Tasks 8 and 11: Scoping fire modeling and detailed fire modeling. More focus should be placed on detailed fire modeling and less focus on scoping fire modeling. This was the approach taken for the fire PRA. • Task 14: Fire risk quantification. Typically, multiple safe shutdown (SSD) components fail during a given fire scenario. Therefore dependent failure analysis is critical to obtaining a meaningful fire risk quantification. Dependent failure analysis for the fire PRA presented several challenges which will be discussed in the full paper.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Lawrence Livermore National Laboratory Emergency Response Capability Baseline Needs Assessment Requirement Document

This revision of the LLNL Fire Protection Baseline Needs Assessment (BNA) was prepared by John A. Sharry, LLNL Fire Marshal and LLNL Division Leader for Fire Protection and reviewed by Martin Gresho, Sandia/CA Fire Marshal. The document follows and expands upon the format and contents of the DOE Model Fire Protection Baseline Capabilities Assessment document contained on the DOE Fire Protection Web Site, but only address emergency response. The original LLNL BNA was created on April 23, 1997 as a means of collecting all requirements concerning emergency response capabilities at LLNL (including response to emergencies at Sandia/CA) into one BNA document. The original BNA documented the basis for emergency response, emergency personnel staffing, and emergency response equipment over the years. The BNA has been updated and reissued five times since in 1998, 1999, 2000, 2002, and 2004. A significant format change was performed in the 2004 update of the BNA in that it was 'zero based.' Starting with the requirement documents, the 2004 BNA evaluated the requirements, and determined minimum needs without regard to previous evaluations. This 2010 update maintains the same basic format and requirements as the 2004 BNA. In this 2010 BNA, as in the previous BNA, the document has been intentionally divided into two separate documents - the needs assessment (1) and the compliance assessment (2). The needs assessment will be referred to as the BNA and the compliance assessment will be referred to as the BNA Compliance Assessment. The primary driver for separation is that the needs assessment identifies the detailed applicable regulations (primarily NFPA Standards) for emergency response capabilities based on the hazards present at LLNL and Sandia/CA and the geographical location of the facilities. The needs assessment also identifies areas where the modification of the requirements in the applicable NFPA standards is appropriate, due to the improved fire protection provided, the remote location and low population density of some the facilities. As such, the needs assessment contains equivalencies to the applicable requirements. The compliance assessment contains no such equivalencies and simply assesses the existing emergency response resources to the requirements of the BNA and can be updated as compliance changes independent of the BNA update schedule. There are numerous NFPA codes and standards and other requirements and guidance documents that address the subject of emergency response. These requirements documents are not always well coordinated and may contain duplicative or conflicting requirements or even coverage gaps. Left unaddressed, this regulatory situation results in frequent interpretation of requirements documents. Different interpretations can then lead to inconsistent implementation. This BNA addresses this situation by compiling applicable requirements from all identified sources (see Section 5) and analyzing them collectively to address conflict and overlap as applicable to the hazards presented by the LLNL and Sandia/CA sites (see Section 7). The BNA also generates requirements when needed to fill any identified gaps in regulatory coverage. Finally, the BNA produces a customized simple set of requirements, appropriate for the DOE protection goals, such as those defined in DOE O 420.1B, the hazard level, the population density, the topography, and the site layout at LLNL and Sandia/CA that will be used as the baseline requirements set - the 'baseline needs' - for emergency response at LLNL and Sandia/CA. A template approach is utilized to accomplish this evaluation for each of the nine topical areas that comprise the baseline needs for emergency response. The basis for conclusions reached in determining the baseline needs for each of the topical areas is presented in Sections 7.1 through 7.9. This BNA identifies only mandatory requirements and establishes the minimum performance criteria. The minimum performance criteria may not be the level of performance desired Lawrence Livermore National Laboratory or Sandia/CA. Performance at levels greater than those established by this document will provide a higher level of fire safety, fire protection, or loss control and is encouraged. In Section 7, Determination of Baseline Needs, a standard template was used to describe the process used that involves separating basic emergency response needs into nine separate services. Each service being evaluated contains a determination of minimum requirements, an analysis of the requirements, a statement of minimum performance, and finally a summary of the minimum performance. The requirement documents, listed in Section 5, are those laws, regulations, DOE Directives, contractual obligations, or LLNL policies that establish service levels. The determination of minimum requirements section explains the rationale or method used to determine the minimum requirements.

99 GENERAL AND MISCELLANEOUS↗

An Observation-Driven Framework for Modeling Post-Fire Hydrologic Response: Evaluation for Two Central California Case Studies

In a warming climate, wildfires are becoming increasingly common, especially in semi-arid environments. Wildfires can disrupt forest ecosystems and induce changes to the land surface. Collectively, these impacts can alter the hydrologic response of a catchment following a fire, resulting in increased potential for surface runoff, reduced evapotranspiration, and, ultimately, a higher risk for flash flooding and mass wasting. The timescale of post-fire recovery of hydrological processes to return to pre-fire conditions is not well established due to the lack of ground measurements. Accurate characterization of the impacts of fire on hydrologic response is also challenging to simulate, given the complex interplay of various processes. Here, we present a generalized framework to quantify the impacts of wildfire on runoff generation. We consider the disturbances in the vegetation and soil as the two main factors contributing to post-fire floods. Using an ensemble modeling structure to account for parameter uncertainty, remotely sensed leaf area index (LAI) is assimilated into a land surface model (LSM) to simulate vegetation disturbance, and the maximum land surface saturation LSM parameter is decreased to parameterize the soil disturbance following observed fires. We consider the impacts of fire-induced changes to LAI and soil saturation on hydrologic states like runoff and evapotranspiration for two case studies. These case studies demonstrate the general applicability of hydrophobicity formulation to serve as a guideline for exploring the range of hydrologic responses post-fire.

Fire Hydrology↗

Using fine-scale fuel measurements to assess wildland fuels, potential fire behavior and hazard mitigation treatments in the southeastern USA.

The inherent spatial and temporal heterogeneity of fuelbeds in forests of the southeastern United States may require fine scale fuel measurements for providing reliable fire hazard and fuel treatment effectiveness estimates. In a series of five papers, an intensive, fine scale fuel inventory from the Savanna River Site in the southeastern United States is used for building fuelbeds and mapping fire behavior potential, evaluating fuel treatment options for effectiveness, and providing a comparative analysis of landscape modeled fire behavior using three different data sources including the Fuel Characteristic Classification System, LANDFIRE, and the Southern Wildfire Risk Assessment. The research demonstrates that fine scale fuel measurements associated with fuel inventories repeated over time can be used to assess broad scale wildland fire potential and hazard mitigation treatment effectiveness in the southeastern USA and similar fire prone regions. Additional investigations will be needed to modify and improve these processes and capture the true potential of these fine scale data sets for fire and fuel management planning.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparing gas composition from fast pyrolysis of live foliage measured in bench-scale and fire-scale experiments

Background: Fire models have used pyrolysis data from oxidising and non-oxidising environments for flaming combustion. In wildland fires pyrolysis, flaming and smouldering combustion typically occur in an oxidising environment (the atmosphere). Aims: Using compositional data analysis methods, determine if the composition of pyrolysis gases measured in non-oxidising and ambient (oxidising) atmospheric conditions were similar. Methods: Permanent gases and tars were measured in a fuel-rich (non-oxidising) environment in a flat flame burner (FFB). Permanent and light hydrocarbon gases were measured for the same fuels heated by a fire flame in ambient atmospheric conditions (oxidising environment). Log-ratio balances of the measured gases common to both environments (CO, CO 2 , CH 4 , H 2 , C 6 H 6 O (phenol), and other gases) were examined by principal components analysis (PCA), canonical discriminant analysis (CDA) and permutational multivariate analysis of variance (PERMANOVA). Key results: Mean composition changed between the non-oxidising and ambient atmosphere samples. PCA showed that flat flame burner (FFB) samples were tightly clustered and distinct from the ambient atmosphere samples. CDA found that the difference between environments was defined by the CO-CO 2 log-ratio balance. PERMANOVA and pairwise comparisons found FFB samples differed from the ambient atmosphere samples which did not differ from each other. Conclusion: Relative composition of these pyrolysis gases differed between the oxidising and non-oxidising environments. This comparison was one of the first comparisons made between bench-scale and field scale pyrolysis measurements using compositional data analysis. Implications: These results indicate the need for more fundamental research on the early time-dependent pyrolysis of vegetation in the presence of oxygen.

54 ENVIRONMENTAL SCIENCES↗

Preliminary mixed-layer model results for FIRE marine stratocumulus IFO conditions

Some preliminary results from the Turton and Nicholls mixed layer model using typical FIRE boundary conditions are presented. The model includes entrainment and drizzle parametrizations as well as interactive long and shortwave radiation schemes. A constraint on the integrated turbulent kinetic energy balance ensures that the model remains energetically consistent at all times. The preliminary runs were used to identify the potentially important terms in the heat and moisture budgets of the cloud layer, and to assess the anticipated diurnal variability. These are compared with typical observations from the C130. Sensitivity studies also revealed the remarkable stability of these cloud sheets: a number of negative feedback mechanisms appear to operate to maintain the cloud over an extended time period. These are also discussed. The degree to which such a modelling approach can be used to explain observed features, the specification of boundary conditions and problems of interpretation in non-horizontally uniform conditions is also raised.

Barlow, R.↗

PFHydro: A New Watershed-Scale Model for Post-Fire Runoff Simulation

Runoff increases after wildfires that burn vegetation and create a condition of soil-water repellence (SWR). A new post-fire watershed hydrological model, PFHydro, was created to explicitly simulate vegetation interception and SWR effects for four burn severity categories: high, medium, low severity and unburned. The model was applied to simulate post-fire runoff from the Upper Cache Creek Watershed in California, USA. Nash–Sutcliffe modeling efficiency (NSE) was used to assess model performance. The NSE was 0.80 and 0.88 for pre-fire water years (WY) 2000 and 2015, respectively. NSE was 0.88 and 0.93 for WYs 2016 (first year post-fire) and 2017 respectively. The simulated percentage of surface runoff in total runoff of WY 2016 was about six times that of pre-fire WY 2000 and three times that of WY 2015. The modeling results suggest that SWR is an important factor for post-fire runoff generation. In conclusion, the model was successful at simulating SWR behavior.

54 ENVIRONMENTAL SCIENCES↗

Design of Superconducting Optoelectronic Networks for Neuromorphic Computing

We have previously proposed a novel hardware platform (SOEN) for neuromorphic computing based on superconducting optoelectronics that presents many of the features necessary for information processing in the brain. Here we discuss the design and training of networks of neurons and synapses based on this technology. We present circuit models for the simplest neurons and synapses that we can use to build networks. We discuss the further abstracted integrate and fire model that we use for evolutionary optimization of small networks of these neurons. We show that we can use the TENNLab evolutionary optimization programming framework to design small networks for logic, control and classification tasks. We plan to use the results as feedback to inform our neuron design.

Buckley, Sonia↗

Base pressure and heat transfer tests of the 0.0225-scale space shuttle plume simulation model (19-OTS) in yawed flight conditions in the NASA-Lewis 10x10-foot supersonic wind tunnel (test IH83)

Wind tunnel tests were performed to determine pressures, heat transfer rates, and gas recovery temperatures in the base region of a rocket firing model of the space shuttle integrated vehicle during simulated yawed flight conditions. First and second stage flight of the space shuttle were simulated by firing the main engines in conjunction with the SRB rocket motors or only the SSME's into the continuous tunnel airstream. For the correct rocket plume environment, the simulated altitude pressures were halved to maintain the rocket chamber/altitude pressure ratio. Tunnel freestream Mach numbers from 2.2 to 3.5 were simulated over an altitude range of 60 to 130 thousand feet with varying angle of attack, yaw angle, nozzle gimbal angle and SRB chamber pressure. Gas recovery temperature data derived from nine gas temperature probe runs are presented. The model configuration, instrumentation, test procedures, and data reduction are described.

Foust, J. W.↗

An Observation-Driven Framework for Modeling Post-Fire Hydrologic Response: Evaluation for Two Central California Case Studies

In a warming climate, wildfires are becoming increasingly common, especially in semi-arid environments. Wildfires can disrupt forest ecosystems and induce changes to the land surface. Collectively, these impacts can alter the hydrologic response of a catchment following a fire, resulting in increased potential for surface runoff, reduced evapotranspiration, and, ultimately, a higher risk for flash flooding and mass wasting. The timescale for post-fire recovery of hydrological processes to return to pre-fire conditions is not well established due to the lack of ground measurements. Accurate characterization of fire impacts on hydrologic response is also challenging to simulate, given the complex interplay of various processes. Here, we present a generalized framework to quantify wildfire impacts on runoff generation. We consider the vegetation and soil disturbances as the primary contributors to post-fire floods. Using an ensemble modeling structure to account for parameter uncertainty and consider model sensitivity, remotely sensed leaf area index (LAI) is assimilated into a land surface model (LSM) to simulate vegetation disturbance, and the maximum land surface saturation LSM parameter is decreased to parameterize the soil disturbance following observed fires. We evaluated the impacts of fire-induced changes to LAI and soil saturation on hydrologic states like runoff and evapotranspiration. Analysis of two events in central California shows that 1) the LAI assimilation has a greater impact on water balance; and 2) the soil scheme captures a range of outcomes, with substantial impacts on surface runoff for some ensemble members, which could affect flood potential.

Timothy M Lahmers↗

2012 Emergency Response Capability Baseline Needs Assessment Requirements Document (Rev. 7.0)

This document was prepared by John A. Sharry, LLNL Fire Marshal and LLNL Division Leader for Fire Protection and reviewed by LLNL Emergency Management Department Head James Colson. The document follows and expands upon the format and contents of the DOE Model Fire Protection Baseline Capabilities Assessment document contained on the DOE Fire Protection Web Site, but only address emergency response.

99 GENERAL AND MISCELLANEOUS↗

Emergency Response Capability Baseline Needs Assessment - Requirements Document

This document was prepared by John A. Sharry, LLNL Fire Marshal and LLNL Division Leader for Fire Protection and reviewed by LLNL Emergency Management Department Head James Colson. The document follows and expands upon the format and contents of the DOE Model Fire Protection Baseline Capabilities Assessment document contained on the DOE Fire Protection Web Site, but only addresses emergency response.

99 GENERAL AND MISCELLANEOUS↗