Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “field validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Acousto-optic tunable filter field spectrometer for validation of airborne and spaceborne imaging spectrometers

A new concept for a field portable spectrometer designed to meet the needs of the remote sensing community is presented. This instrument uses acoustooptic tunable filters (AOTFs) as wavelength sorters, allowing the design of a rugged, compact, light-weight tool that provides broad spectral coverage, great versatility, and ease of utilization. The spectrometer provides continuous spectral coverage from 0.4 to 2.5 microns with two channels defined by detector technology, while a visible channel covering the 0.4 to 1.0 micron spectral range uses silicon PV photodiodes. The short-wavelength IR channel covers the 0.9 to 2.5 micron special range with thermoelectrically cooled lead sulfide PC detectors.

Rider, David M.↗

Validated Reactive Force Field Quantifies MXene Interfacial Properties, Mechanics, and Thermal Transport

MXenes combine rich surface chemistry, mechanical strength, and high conductivity for a multitude of emerging applications. Predictive modeling supports accelerated materials designs and has been limited by the absence of validated and transferable force fields. Here, we introduce an interpretable, reactive INTERFACE force field (IFF and IFF-R) for Ti 3 C 2 T x MXenes that is trained based on chemical knowledge and achieves quantitative agreement with experiments across lattice parameters (<0.5%), density (<0.2%), liquid contact angles, Raman spectra, and the in-plane elastic modulus (∼320 GPa). The models cover surface terminations from hydroxyl (−OH) to fluorine (−F) groups and are extensible to other chemistries. We introduce pH-resolved surface chemistry and identify dopamine adsorption mechanisms at MXene–aqueous interfaces supported by QCM-D and UV–Vis experiments. The data reveal coplanar and perpendicular binding modes and concentration-dependent multilayer assembly. We predict previously inaccessible properties, including termination-dependent cleavage energies, interlayer shear moduli and dynamic shear failure, nanoindentation and brittle fracture, anisotropic in-plane and out-of-plane thermal conductivities, including the role of defects. Agreement with available experimental data is consistently close and exceeds DFT accuracy across the benchmark properties examined. The IFF/IFF-R model is compatible with CHARMM, AMBER, OPLS, and CVFF force fields for simulations of MXenes with diverse surface terminations, electrolyte interfaces, biointerfaces, and polymer composites without additional parameters. Parameter sets, 3D models, and analysis scripts are provided for community use. The validated, reactive, and transferable IFF framework facilitates predictive design of MXene-based films, membranes, sensing interfaces, and composites.

MXene↗

3-D Flow Field Diagnostics and Validation Studies using Stereoscopic Tracking Velocimetry

The measurement of 3-D three-component velocity fields is of great importance in both ground and space experiments for understanding materials processing and fluid physics. Here, we present the investigation results of stereoscopic tracking velocimetry (STV) for measuring 3-D velocity fields. The effort includes diagnostic technology development, experimental velocity measurement, and comparison with analytical and numerical computation. The advantages of STV stems from the system simplicity for building compact hardware and in software efficiency for continual near-real-time process monitoring. It also has illumination flexibility for observing volumetric flow fields from arbitrary directions. STV is based on stereoscopic CCD observations of particles seeded in a flow. Neural networks are used for data analysis. The developed diagnostic tool is tested with a simple directional solidification apparatus using Succinonitrile. The 3-D velocity field in the liquid phase is measured and compared with results from detailed numerical computations. Our theoretical, numerical, and experimental effort has shown STV to be a viable candidate for reliably quantifying the 3-D flow field in materials processing and fluids experiments.

Cha, Soyoung Stephen↗

Resilient Operation of Networked Community Microgrids with High Solar Penetration

This project, funded by the US Department of Energy’s Solar Energy Technologies Office (SETO), focused on the operation of microgrids as a coordinated network. The primary objective, which was successfully achieved, was to develop both control strategies and hardware solutions to support the resilient and efficient operation of networked microgrids with high solar penetration. The work was structured around the following four main tasks: • Development of distributed and scalable optimization algorithms for AC-coupled networked microgrids. • Design and implementation of a novel DC interconnection hardware to enable precise power exchange between microgrids. • Laboratory operational validation of the developed technologies using 480 V testbeds and commercially available hardware. • Field operational validation of the complete solution in Adjuntas, Puerto Rico, interconnecting two kW-scale, split-phase microgrids of Casa Pueblo’s microgrids. This project addressed multiple technical challenges across the domains of optimization, control, hardware interconnection, and protection. One of its key contributions was delivering tangible, real-world solutions for networking microgrids. In contrast to purely theoretical or simulation-based work, this project included full-scale hardware operational validation both in the lab and in the field. The work conducted as part of this project—in collaboration with the University of Puerto Rico; the University of Tennessee, Knoxville; the University of Central Florida; and Casa Pueblo—has advanced the state of the art in networked microgrids. Key contributions include the development of distributed control strategies, practical solutions for real-world implementation challenges, and the introduction of a novel DC interlink approach for microgrid interconnection. The project featured both laboratory and field validation using commercial off-the-shelf components. The field deployment successfully validated that a group of microgrids can operate in a coordinated manner, enabling precise power flow between systems and mutual support during extreme events. This project resulted in 15 journal publications and 15 conference papers; 5 graduate students and 15 undergraduate students were supported. The codes of distributed optimization and forecasting were made open-source through OSTI.gov for distributed optimization and forecasting. All the publications are available in the ORNL-hosted project landing page. The DC interlink with state-of-charge balancing control was operationally validated in Adjuntas by interconnecting two real-world, 240 V split-phase microgrids. To the best knowledge of the team, this represents the first operational validation of AC microgrids interconnected via DC-interlinks. As a culmination of this project, a follow-on grant was awarded to support the technology transfer of the distributed optimization framework to a commercial microgrid controller, Stellar Edge, developed by the California-based company New Sun Road.

14 SOLAR ENERGY↗

Two Decades Observing Smoke Above Clouds in the South-Eastern Atlantic Ocean: Deep Blue Algorithm Updates and Validation with ORACLES Field Campaign Data

This study presents and evaluates an updated algorithmfor quantification of absorbing aerosols above clouds(AACs) from passive satellite measurements. The focus isbiomass burning in the south-eastern Atlantic Ocean duringthe 2016 and 2017 ObseRvations of Aerosols above CLoudsand their intEractionS (ORACLES) field campaign deployments.The algorithm retrieves the above-cloud aerosoloptical depth (AOD) and underlying liquid cloud opticaldepth and is applied to measurements from the Sea-viewingWide Field-of-view Sensor (SeaWiFS), Moderate ResolutionImaging Spectroradiometer (MODIS), and Visible InfraredImaging Radiometer Suite (VIIRS) from 1997 to 2017. AirborneNASA Ames Spectrometers for Sky-Scanning, Sun-Tracking Atmospheric Research (4STAR) and NASA LangleyHigh Spectral Resolution Lidar 2 (HSRL2) data collectedduring ORACLES provide important validation for spectralAOD for MODIS and VIIRS; as the SeaWiFS missionended in 2010, it cannot be evaluated directly. The 4STARand HSRL2 comparisons are complementary and reveal performancegenerally in line with uncertainty estimates providedby the optimal estimation retrieval framework used. Atpresent the two MODIS-based data records seem the mostreliable, although there are differences between the deployments,which may indicate that the available data are not yetsufficient to provide a robust regional validation. Spatiotemporalpatterns in the data sets are similar, and the time seriesare very strongly correlated with each other (correlationcoefficients from 0.95 to 0.99). Offsets between the satellitedata sets are thought to be chiefly due to differences in absolutecalibration between the sensors. The available validationdata for this type of algorithm are limited to a small numberof field campaigns, and it is strongly recommended that suchairborne measurements continue to be made, both over thesouthern Atlantic Ocean and elsewhere.

Sayer, Andrew M.↗

Field testing and validation of a low-cost MPC for demand flexibility for grid-interactive K-12 schools

K-12 school buildings account for the highest energy consumption within the public sector. Implementing advanced HVAC controls in grid-interactive K-12 schools could bring substantial economic advantages and grid flexibility. Our previous study demonstrated that a low-cost model predictive control (MPC) solution, which coordinates multiple packaged units, can enable demand flexibility without major hardware upgrades. However, a significant gap remains between academic pilots and market-ready scalable solutions. This paper extends the previous single-site pilot to a multi-site demonstration involving three school campuses (95 total units) through a commercial technology transfer process. Addressing the challenge of verifying performance with sparse field data, we present a new statistical approach using Bayesian methods to estimate the MPC’s effect on peak demand. Unlike traditional methods, this approach robustly quantifies uncertainty in non-normal, limited datasets. The results confirm the solution’s replicability, achieving a 21.6–38.9% reduction in HVAC peak demand (10.8–22.1% at the site-level) with > 98% probability across diverse locations. Finally, we document critical barriers to scaling software-as-a-service (SaaS) solutions–such as API instability and diverse legacy systems–and offer practical strategies to accelerate the commercial adoption of grid-interactive efficient buildings.

Ham, Sang Woo↗

Signal Processing in SBND with Calibrated and Validated Electronics and Field Responses

SBND is a liquid argon time projection chamber in Fermilab’s Short-Baseline Neutrino Program, located 110 m from the neutrino source and operating in a high-rate environment with unprecedented statistics. Charged particles from neutrino interactions ionize the argon, and the resulting electrons drift to the anode wires, inducing current signals recorded as raw waveforms. These waveforms are a convolution of deposited charge with the electronics and TPC field responses, making accurate signal processing essential for recovering the true charge distribution. Signal processing forms the starting point for SBND reconstruction, directly impacting hit finding, charge calibration, clustering, and the reconstruction of tracks and showers, and therefore playing a key role in energy reconstruction and particle identification. In this poster, we present an overview of the SBND signal processing chain, including noise removal, channel-by-channel electronics correction, signal identification, and deconvolution using measured electronics and TPC field responses. We demonstrate that the two kernel functions—electronics and field responses—achieve high precision when compared to data, ensuring that the SBND signal processing chain provides a robust and accurate foundation for event reconstruction and precision physics measurements.

Singh, Prabhjot [Louisiana State U.] (ORCID:000000↗

Validity of central field approximations in molecular scattering - Low energy CO-He collisions

Close-coupled calculations have been carried out on collisions of helium and carbon monoxide interacting via a theoretical interaction potential which is believed to reproduce accurately the true interaction of this system. These are compared with an equivalent set of calculations for the spherical average of this potential. It is concluded that the latter approximation holds reasonably well for transport-property calculations but not for differential and total scattering cross sections. As a consequence, conservation of scattering-cross-section theorems that are based on this interaction potential do not hold well.

Monchick, L.↗

Time domain numerical calculations of unsteady vortical flows about a flat plate airfoil

A time domain numerical scheme is developed to solve for the unsteady flow about a flat plate airfoil due to imposed upstream, small amplitude, transverse velocity perturbations. The governing equation for the resulting unsteady potential is a homogeneous, constant coefficient, convective wave equation. Accurate solution of the problem requires the development of approximate boundary conditions which correctly model the physics of the unsteady flow in the far field. A uniformly valid far field boundary condition is developed, and numerical results are presented using this condition. The stability of the scheme is discussed, and the stability restriction for the scheme is established as a function of the Mach number. Finally, comparisons are made with the frequency domain calculation by Scott and Atassi, and the relative strengths and weaknesses of each approach are assessed.

Hariharan, S. I.↗

Time domain numerical calculations of unsteady vortical flows about a flat plate airfoil

A time domain numerical scheme is developed to solve for the unsteady flow about a flat plate airfoil due to imposed upstream, small amplitude, transverse velocity perturbations. The governing equation for the resulting unsteady potential is a homogeneous, constant coefficient, convective wave equation. Accurate solution of the problem requires the development of approximate boundary conditions which correctly model the physics of the unsteady flow in the far field. A uniformly valid far field boundary condition is developed, and numerical results are presented using this condition. The stability of the scheme is discussed, and the stability restriction for the scheme is established as a function of the Mach number. Finally, comparisons are made with the frequency domain calculation by Scott and Atassi, and the relative strengths and weaknesses of each approach are assessed.

Hariharan, S. I.↗

Validity of the field line resonance expansion

The field line resonance expansion is studied with a magnetohydrodynamic (MHD) model applicable to earth's magnetotail. Using a Frobenius series solution, this expansion is found to be inconsistent. The inconsistency is seen by evaluating the terms in the model equations that the expansion neglects as small. Their effect is to provide a solution more singular than that determined by the expansion procedure. A tentative alternative expansion procedure, retaining these neglected terms approximately, yields a nonsingular solution, suggesting that resonant mode conversion rather than field line resonance is the appropriate phenomenon.

Hansen, P. J.↗

Using Microwave Limb Sounder Data to Validate Model Ice Fields

MLS IWC overall tends to be higher relative to ECMWF after considering MLS track sampling and sensitivity (cutoff application). Disagreement tends to be accentuated over Indian and Western Pacific Oceans and over tropical landmasses. Large disagreement occur at upper level at 147 hPa but small at lower levels at 215 and 316 hPa suggesting the need to investigate the strength of model large-scale circulation and physics associated with the IWC formation. Future work includes: Present MMF/ECMWF Comparisons at AGU/Baltimore Session on MMF/Cloud Resolving Modeling, GMAO/GSFC & at the WPac/Bejing/AGU in Tao's Cloud-Radiation Session. Write-up Results on ECMWF/MLS Comparisons for GRL. Continue with MLS vs ECMWF Water Vapor & Temperature comparisons - will seek more interaction with other MLS colleagues. Investigate the Development of Biases in ECMWF Forecasts - i.e. in the actual model. Work with GMAO-5 development team regarding their cloud microphysics performance. Integrate CloudSat into IWC Analyses.

cloud ice↗

Compact, Engineered, 2-Micron Coherent Doppler Wind Lidar Prototype for Field and Airborne Validation: Doppler Aerosol WiNd Lidar (DAWN). Interim Review #1 (6 months)

A new project, selected in 2005 by NASA's Science Mission Directorate (SMD), under the Instrument Incubator Program (IIP), will be described. The 3-year effort is intended to design, fabricate, and demonstrate a packaged, rugged, compact, space-qualifiable coherent Doppler wind lidar (DWL) transceiver capable of future validation in an aircraft and/or Unmanned Aerial Vehicle (UAV). The state-of-the-art 2-micron coherent DWL breadboard at NASA/LaRC will be engineered and compactly packaged consistent with future aircraft flights. The packaged transceiver will be integrated into a coherent DWL system test bed at LaRC. Atmospheric wind measurements will be made to validate the packaged technology. This will greatly advance the coherent part of the hybrid DWL solution to the need for global tropospheric wind measurements.

Kavaya, Michael J.↗

All-digital Sensor System for Distributed Downhole Pressure Monitoring in Unconventional Fields

This project developed and validated (through field tests) a new low-cost all-digital pressure sensing technology for in situ distributed downhole pressure monitoring in unconventional oil and gas (UOG) fields. The all-digital sensing technology uses a built-in non-electric analog-to-digital converter (ADC) to transform the pressure information into a combination of binary (ON/OFF) states. As such, the system does not need downhole electronics for signal conditioning and telemetry. The all-digital sensors can be remotely logged over a long distance, and many sensors can be multiplexed for distributed sensing. Based on a review of unconventional wells in the Lower 48 states, the specification of the sensor is to measure pressure up to 69 MPa (10,000 psi) and temperature up to 250°C. A sensor with a helical bourdon sensing element and a digital signal decoder of 50 mm diameter and 109 mm length was constructed. The helical bourdon sensing element was made of 304L stainless steel and filled with motor oil. The digital converter was made up of 8 digital reading pads constructed of high-temperature epoxy with conductive inserts made of stainless steel. The sensor had a linear response to pressure with an accuracy of 0.14 MPa (20 psi). To withstand the high pressure, the sensor was enclosed in a stainless-steel pressure housing with a wall thickness of 5.5 mm, a diameter of 73 mm, and a length of 724 mm. In the laboratory tests, the sensor exhibited no temperature-related effects on the results. The sensor did not show drift over a 14-day test period at elevated pressure. A field test was conducted where the sensor was deployed in a test wellbore at the Quest drilling test facility to a depth of 0 feet over three weeks. The sensor was attached to the production rods, along with a downhole reference sensor of PPS27 type, which is a permanent downhole monitoring system. During the testing phase, the test well annular blow-out preventer was closed, and the well was pressurized at the surface to 11 MPa (1600 psi). The sensor read the elevated bottom hole pressure of 1500 psi. A multiplexing unit was created for the sensor to deploy multiple sensors on one data transmission line in a distributed approach. The multiplexing unit was tested in a simulated environment of 3048 m (10,000 ft) with five sensors distributed. The sensors were pressurized at different intervals. The multiplexed sensors recorded the correct pressure, and the multiplexing did not interfere with the readings. The proposed concept of an all-digital pressure sensor for harsh downhole environments was designed, manufactured, and tested in the laboratory and tested at the field to a up to 69 MPa and 250°C. This technology has high-temperature tolerance and has potential in downhole areas outside oil and gas, such as carbon capture and storage (CCS) and geothermal wells. The sensor concept has been proven in this project, but to create a commercially viable product, manufacturing a sensor with a smaller diameter needs to be performed.

02 PETROLEUM↗

Nonsteady Load Responses of Wind Turbines to Atmospheric and Mountain-Generated Turbulence Eddies, With Impacts on the Main Bearing: A Validation Study

Previous computational and field experiments identify three characteristic time scales in the aerodynamic responses of utility-scale wind turbine loads to atmospheric boundary layer (ABL) turbulence: a 30-90 second time scale for the passage of high/low speed "streaks" through the rotor plane, the blade and rotor rotation time scales (approximately 1 to 5 seconds), and a sub-second time scale created by blade rotation through gradients within eddy coherent structure. In the current study we compare aerodynamic load responses from daytime ABL turbulence quantified with large-eddy simulation and a actuator line model of the NREL 5 MW wind turbine with analysis of field data from the NREL/GE 1.5 MW wind turbine 5 kilometers east of the Rocky Mountain Front Range in Colorado. In addition, we contrast the responses to the passage of the mountain-generated eddies embedded within the westerly winds with the ABL eddies embedded within northerly/southerly winds. These analyses are in context with the nonsteady forcing of the main bearing by the aerodynamic generation of nontorque bending moments on the main shaft. Potentially relevant to main bearing failure mechanisms, both computational and field data show that the magnitudes of turbulence-generated nontorque bending moments, that we show generate nonsteady force on the main bearing, are of order, and often larger than, torque (which underlies power). However, the temporal variations in these two responses are uncorrelated, implying that the aerodynamic mechanisms that drive power and main bearing response are fundamentally different. We find this to be the case in the field with both mountain-generated eddies (westerly winds) and ABL-generated eddies (northerly/southerly winds). Whereas the time and length scales are comparable, the mountain eddies were somewhat more energetic than the northerly/southerly ABL eddies. Interestingly, however, the fluctuations in nontorque bending moment that force the main bearing were found to be stronger when forced by the ABL eddies than the mountain eddies. The field studies validate the key results from the computational study and show even stronger response in the nontorque bending moment than in the computer simulations. In all cases, the torque and nontorque bending moments are temporally uncorrelated, torque and power are driven by time variations in rotor-averaged horizontal wind velocity and nontorque bending moments are driven by time changes in the degree of nonuniformity in the distribution of velocity over the rotor plane. Thus the results generalize the mechanisms underlying nonsteady aerodynamic forcing to classes of turbulence eddy types with strength of order or stronger than ABL eddies with transverse scale of order the wind turbine rotor. These include atmospheric turbulence eddies, topography-generated turbulence eddies and, by extension, impacts of turbine-wake-scale turbulence eddies on downstream wind turbine rotors.

17 WIND ENERGY↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗