Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ferromagnetic resonance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Apollo 16 regolith breccias - Characterization and evidence for early formation in mega-regolith

The Apollo 16 regolith breccias were characterized in terms of petrography, grain-size distribution, porosity, major and trace element composition, noble gas contents, and ferromagnetic resonance properties. Significant variation was found with respect to density and porosity; the more dense breccias displayed substantial shock damage. The breccias resembled the soils in grain-size distribution and in petrological components, though many were found to be compositionally different from the Apollo 16 soils in that a mafic component was lacking. Nearly all breccias showed evidence of irradiation at the lunar surface, and analyses of disaggregated breccias indicated that this irradiation occurred before compaction. The concentration of surface irradiation parameters were far less than those of lunar soils or breccias of other Apollo missions. Observations with respect to the argon isotope ratio and Xe presence have led to the possibility that breccia-surface irradiation occurred as early as four billion years ago, and that most Apollo 16 regolith breccias were not formed from any known Apollo 16 soil.

Mckay, D. S.↗

Moessbauer Spectroscopy for Lunar Resource Assessment: Measurement of Mineralogy and Soil Maturity

First-order assessment of lunar soil as a resource includes measurement of its mineralogy and maturity. Soils in which the mineral ilmenite is present in high concentrations are desirable feedstock for the production of oxygen at a lunar base. The maturity of lunar soils is a measure of their relative residence time in the upper 1 mm of the lunar surface. Increasing maturity implies increasing load of solar wind species (e.g., N, H, and He-3), decreasing mean grain size, and increasing glass content. All these physicochemical properties that vary in a regular way with maturity are important parameters for assessing lunar soil as a resource. For example, He-3 can be extracted and potentially used for nuclear fusion. A commonly used index for lunar soil maturity is I(sub s)/FeO, which is the concentration of fine-grained metal determined by ferromagnetic resonance (I(sub s)) normalized to the total iron content (as FeO). I(sub s)/FeO has been measured for virtually every soil returned by the Apollo and Luna missions to the Moon. Because the technique is sensitive to both oxidation state and mineralogy, iron Moessbauer spectroscopy (FeMS) is a viable technique for in situ lunar resource assessment. Its utility for mineralogy is apparent from examination of published FeMS data for lunar samples. From the data published, it can be inferred that FeMS data can also be used to determine soil maturity. The use of FeMS to determine mineralogy and maturity and progress on development of a FeMS instrument for lunar surface use are discussed.

Morris, R. V.↗

Magnetic Susceptibility Measurements for in Situ Characterization of Lunar Soil

Magnetic separation is a viable method for concentration of components of lunar soils and rocks for use as feedstocks for manufacture of metals, oxygen, and for recovery of volatiles such as He-3. Work with lunar materials indicates that immature soils are the best candidates for magnetic beneficiation. The magnetic susceptibility at which selected soil components such as anorthite, ilmenite, or metallic iron are separated is not affected by soil maturity, but the recovery of the concentrated components is. Increasing soil maturity lowers recovery. Mature soils contain significant amounts of glass-encased metallic iron. Magnetic susceptibility, which is sensitive to metallic iron content, can be used to measure soil maturity. The relationship between the ratio of magnetic susceptibility and iron oxide and the conventional maturity parameter, I(sub s)/FeO, ferromagnetic resonant intensity divided by iron oxide content is given. The magnetic susceptibilities were determined using apparatus designed for magnetic separation of the lunar soils.

Oder, R. R.↗

Lithological Variation with Depth and Decoupling of Maturity Parameters in Apollo 16 Regolith Core 68001/2

Using FerroMagnetic Resonance (FMR) and Instrumental Neutron Activation Analysis (INAA), we have determined the maturity (surface exposure) parameter I(sub s)/FeO and concentrations of twenty- five chemical elements on samples taken every half centimeter down the 61-cm length of the 68001/2 regolith core (double drive tube) collected at station 8 on the Apollo 16 mission to the Moon. Contrary to premission expectations, no ejecta or other influence from South Ray crater is evident in the core, although a small inflection in the I(sub s)/FeO profile at 3 cm depth may be related the South Ray crater impact. Regolith maturity generally decreases with depth, as in several previously studied cores. We recognize five compositionally distinct units in the core, which we designate A through E, although all are similar in composition to each other and to other soils from the Cayley plains at the Apollo 16 site. Unit A (0-33 cm) is mature to submature throughout (I(sub s)/FeO: 89-34 units) and is indistinguishable in composition from surface soils collected at station 8. Unit B (33-37 cm) is enriched slightly in a component of anorthositic norite composition. Unit D (42-53 cm) is compositionally equivalent to 80 wt% Unit-A soil plus 20 wt% Apollo-16-type dimict breccia consisting of subequal parts anorthosite and impact-melt breccia. Compared to Unit A, Unit E (53-61 cm) contains a small proportion (up to 4%) of some component compositionally similar to Apollo 14 sample 14321. Unit C (37-42 cm) is unusual. For lithophile and siderophile elements, it is similar to Units A and D. However, I(sub s)/FeO is low throughout the unit (less than 30 units) and in a bluish-gray zone at 41 cm depth I(sub s)/FeO drops to 1.6 units, the lowest value that we have observed in several hundred Apollo 16 soil samples. Samples from the bluish-gray zone also have low Zn concentrations, less than 10 micro g/g, compared to 20-30 micro g/g for the rest of the core. Although both values are consistent with fragmented rock material that has received virtually no surface exposure, the abundance of agglutinates in the bluish-gray soil of Unit C is moderately high, typical of a submature soil that would ordinarily have I(sub s)/FeO - 30. We believe that the anomalously low values of I(sub s)/FeO and Zn concentration result because the soil was heated to -800-1000 'C, probably during an impact. This temperature range is sufficient to volatize the surface-correlated Zn and agglomerate the nanophase metal giving rise to the FMR signal but is not great enough to sinter the soil. Alternatively, the unusual soil interval may represent a disaggregated or incipient regolith breccia, although there is no significant difference in the texture or clast-matrix relationships between Unit C and adjacent units.

Korotev, Randy L.↗

Magnetic Tunnel Junction-Based On-Chip Microwave Phase and Spectrum Analyzer

A magnetic tunnel junction (MTJ)-based microwave detector is proposed and investigated. When the MTJ is excited by microwave magnetic fields, the relative angle between the free layer and pinned layer alternates, giving rise to an average resistance change. By measuring the average resistance change, the MTJ can be utilized as a microwave power sensor. Due to the nature of ferromagnetic resonance, the frequency of an incident microwave is directly determined. In addition, by integrating a mixer circuit, the MTJ-based microwave detector can also determine the relative phase between two microwave signals. Thus, the MTJbased microwave detector can be used as an on-chip microwave phase and spectrum analyzer.

Fan, Xin↗

Magnetic Tunnel Junction-Based On-Chip Microwave Phase and Spectrum Analyzer

A magnetic tunnel junction (MTJ)-based microwave detector is proposed and investigated. When the MTJ is excited by microwave magnetic fields, the relative angle between the free layer and pinned layer alternates, giving rise to an average resistance change. By measuring the average resistance change, the MTJ can be utilized as a microwave power sensor. Due to the nature of ferromagnetic resonance, the frequency of an incident microwave is directly determined. In addition, by integrating a mixer circuit, the MTJ-based microwave detector can also determine the relative phase between two microwave signals. Thus, the MTJ-based microwave detector can be used as an on-chip microwave phase and spectrum analyzer.

microwave spectra↗

Broadband Characterization of Stress Induced Anisotropy in Nanocomposite Co74.6Fe2.7Mn2.7Nb4Si2B14

We report on the broadband characterization of Co74:6Fe2:7Mn2:7Nb4Si2B14 (at%) melt-spun, soft magnetic alloy ribbons after various secondary processing treatments. Ribbons were investigated in the as-cast (melt-spun) condition, after annealing under stress at 50 - 200 MPa, and after transverse magnetic field (TMF) annealing. The magnetization dynamics of these materials have been studied from 10 - 60 GHz using ferromagnetic resonance (FMR). The in-plane uniaxial anisotropy was determined from the FMR data and permeability extracted for each condition. The permeability determined from broadband FMR was in good agreement with independently determined values using vibrating sample magnetometry and impedance spectrometry of toroidal cores. The effective damping parameter (α (sub ϱff)) of all the samples was close to 0.015 except for the TMF sample, which showed higher damping, possibly due to two magnon scattering.

Abhishek Srivastava↗

Stratigraphy of the Apollo 17 Landslide Core 73002 From FMR Maturity and VNIR and Mössbauer Spectroscopy

A suite of samples from the Apollo missions to the Moon (1969-1973) were set aside and stored under controlled conditions to have unexamined lunar samples available decades later for analyses that take advantage of evolved sample handling techniques, maturation of then existing instrumentation, and development of new analytical techniques and instrumentation [e.g., 1]. One preserved sample is the Apollo 17 double drive tube core (73001/2) that was driven into the lunar surface on the landslide deposit at Station 3 on the South Massif in the Taurus-Littrow valley [2]. The deeper section (73001) was stored frozen in a Core Sample Vacuum Container (CSVC) to maximize preservation of lunar volatiles. We report here, as a part of the Apollo Next Generation Sample Analysis (ANGSA) Initiative [1,3], stratigraphy for the upper core section (73002) with respect to maturity (ferromagnetic resonance (FMR) maturity index Is/FeO [4-6]), visible-near-IR (VNIR) spectroscopy, and, for representative samples, grain-size analysis and Mössbauer spectroscopy. Stratigraphy provides data to model the dynamics of lunar landslide deposits and their post-emplacement evolution in comparison to impact-driven mixing on an airless body and stratigraphic context for volatile and (if any) organic behavior. Reported by [7] are preliminary results for multispectral imaging and hyperspectral scanning of the first dissection pass of 73002.

R. V. Morris↗

Determining Surface Exposure Ages of Regolith Grains in Lunar Core Sample 73002 By Investigating Solar Particle Irradiation Damage

Space weathering causes the surface soils of airless bodies like the Moon to be micro-structurally and chemically altered by exposure to micrometeoroid bombardment and solar wind irradiation. These alterations accumulate in surface grains with continued residence in the uppermost millimeters of regolith. Low energy solar wind ions (largely H+ and He+) produce a layer of radiation damage as they become implanted in grain surfaces. Also present are solar energetic particle (SEP) tracks, which are nanoscale lineations within grain interiors formed by heavy, high-energy ions (mainly Fe group nuclei) penetrating up to millimeters below the surface. Recent work has determined that the width of solar wind-damaged rims on anorthite and olivine, and their respective SEP track densities are correlated with each other and with grain surface exposure age. Core sample 73002, recently released under the Apollo Next Generation Sample Analysis (ANGSA) Program, has provided an opportunity to study material collected from the light mantle formation in the Taurus-Littrow Valley during Apollo 17. The light mantle is thought to have been deposited vial and slide originating from the neighboring South Massif. Spectral analysis of bulk core soils found a plagioclase rich composition, confirming a highlands origin of the formation. Spectral profiles and ferromagnetic resonance (FMR) measurements of bulk soils sampled at cm-intervals from 73002 indicate that regolith up to~9.5 cm in depth have maturity indices consistent with longer durations of surface processing than samples deeper in the core. Thus, this upper ~9 cm layer likely represents the maximum extent of an in-situ reworking zone which may have persisted over 5 to 17million years. Here we present an analysis of grain exposure ages within the in-situ reworking zone of 73002derived from SEP track density measurements via transmission electron microscopy.

J A McFadden↗

Spin pumping driven by magnon-polaritons in a ferromagnet–coplanar superconducting resonator hybrid system

We demonstrate spin pumping driven by a strongly coupled magnon-photon system using a ferromagnet-coplanar superconducting resonator hybrid system at 1.4 K. Electrical readout via the inverse spin-Hall effect reveals characteristic coupling features, including mode splitting and linewidth broadening, demonstrating the electrical detection of strongly coupled microwave photons and magnons. The microwave magnon-photon coupling strength obtained by combined spin pumping and inverse spin-Hall effect measurements is compared to microwave transmission experiments. Here, microwave power-dependent measurements reveal a decrease in the coupling strength with increasing microwave power alongside the onset of nonlinearities of the superconducting resonator above a critical microwave power threshold.

Wagle, Dinesh [University of Delaware, Newark, DE ↗

Microwave resonance thermomagnetic analysis - A new method for characterizing fine-grained ferromagnetic constituents in lunar materials

Microwave resonance thermomagnetic analysis (MRTA) is the name given to a newly evolved technique for inferring the natures of fine-grained ferromagnetic constituents in lunar materials. Based on standard ferromagnetic resonance (FMR) procedures, the method makes use of the microwave skin effect for diagnosing the presence of metallic iron. Modelling experiments carried out on well-characterized iron and magnetitelike precipitates produced independently in simulated lunar glasses, coupled with published data for magnetite, provide a potential basis for detecting and discriminating between iron metal and ferric iron spinel, even when both are present in an unknown sample. Application of the technique to the lunar samples indicates the possible existence of magnetitelike phases in amounts up to about 0.3 wt% in soils from seven samples regions of the moon. These findings do not require any special geologic processes for their explanation, although some evidence supports the suggestion that fumarolic activity may have occurred in the lunar highlands.

Griscom, D. L.↗

A quantum material spintronic resonator

In a spintronic resonator a radio-frequency signal excites spin dynamics that can be detected by the spin-diode effect. Such resonators are generally based on ferromagnetic metals and their responses to spin torques. New and richer functionalities can potentially be achieved with quantum materials, specifically with transition metal oxides that have phase transitions that can endow a spintronic resonator with hysteresis and memory. Here we present the spin torque ferromagnetic resonance characteristics of a hybrid metal-insulator-transition oxide/ ferromagnetic metal nanoconstriction. Our samples incorporate V 2 O 3 , with Ni, Permalloy (Ni 80 Fe 20 ) and Pt layers patterned into a nanoconstriction geometry. The first order phase transition in V 2 O 3 is shown to lead to systematic changes in the resonance response and hysteretic current control of the ferromagnetic resonance frequency. Further, the output signal can be systematically varied by locally changing the state of the V 2 O 3 with a dc current. These results demonstrate new spintronic resonator functionalities of interest for neuromorphic computing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Temperature Dependent Spin Dynamics in La 0.67 Sr 0.33 MnO 3 /Pt Bilayers

Complex ferromagnetic oxides such as La 0.67 Sr 0.33 MnO 3 (LSMO) offer pathways for creating energy‐efficient spintronic devices with new functionalities. LSMO exhibits high‐temperature ferromagnetism, half metallicity, sharp resonance linewidth, low damping, and a large anisotropic magnetoresistance response. Combined with Pt, a proven material with high spin‐charge conversion efficiency, LSMO can be used to create robust nano‐oscillators for neuromorphic computing. Ferromagnetic resonance (FMR) and device‐level spin‐pumping FMR measurements are performed to investigate the magnetization dynamics and spin transport in NdGaO 3 (110)/LSMO(15 nm)/Pt(0 and 5 nm) thin films ranging from 300 K to 90 K and compare the device performance with Py(7 nm)/Pt(5 nm) sample. The spin current pumped into Pt is quantified to determine the temperature‐dependent influence of interfacial interactions. The generated spin current in the micro‐device is maximum at 170 K for the optimally grown LSMO/Pt films. Additionally, this bilayer system exhibits low magnetic Gilbert damping (0.002), small linewidth (12 Oe), and a large spin Hall angle (≈3.2%) at 170 K. Ex situ deposited LSMO/Pt bilayers demonstrate excellent dynamic response, exhibiting fourfold enhancement in signal output, eightfold reduction in damping, and a threefold reduction in linewidth as compared to the Pt/Py system. Such robust device‐level performance can pave way for energy‐efficient spintronic‐based devices.

complex perovskite thin films↗

Spatially-resolved dynamic sampling of different phasic magnetic resonances of nanoparticle ensembles in a magnetotactic bacterium Magnetospirillum magnetotacticum

Abstract Nanoscaled magnetic particle ensembles are promising building blocks for realizing magnon based binary logic. Element-specific real-space monitoring of magnetic resonance modes with sampling rates in the GHz regime is imperative for the experimental verification of future complex magnonic devices. Here we present the observation of different phasic magnetic resonance modes using the element-specific technique of time-resolved scanning transmission x-ray microscopy within a chain of dipolarly coupled Fe 3 O 4 nanoparticles (40–50 nm particle size) inside a single cell of a magnetotactic bacterium Magnetospirillum magnetotacticum . The particles are probed with 25 nm resolution at the Fe L 3 x-ray absorption edge in response to a microwave excitation of 4.07 GHz. A plethora of resonance modes is observed within multiple particle segments oscillating in- and out-of-phase, well resembled by micromagnetic simulations.

time-resolved scanning transmission x-ray microsco↗

Direct probing of strong magnon–photon coupling in a planar geometry

We demonstrate direct probing of strong magnon–photon coupling using Brillouin light scattering (BLS) spectroscopy in a planar geometry. The magnonic hybrid system comprises a split-ring resonator loaded with epitaxial yttrium iron garnet thin films of 200 nm and 2.46 μm thickness. Here, the BLS measurements are combined with microwave spectroscopy measurements where both biasing magnetic field and microwave excitation frequency are varied. The cooperativity for the 200 nm-thick YIG films is 1.1, and larger cooperativity of 29.1 is found for the 2.46 μm-thick YIG film. We show that BLS is advantageous for probing the magnonic character of magnon–photon polaritons, while microwave absorption is more sensitive to the photonic character of the hybrid excitation. A miniaturized, planar device design is imperative for the potential integration of magnonic hybrid systems in future coherent information technologies, and our results are a first stepping stone in this regard. Furthermore, successfully detecting the magnonic hybrid excitation by BLS is an essential step for the up-conversion of quantum signals from the microwave to the optical regime in hybrid quantum systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultralow effective Gilbert damping and induced orbital moment in strain-engineered FeGe films with Curie temperature exceeding room temperature

We report the magnetic and magnetodynamic properties of strained epitaxial FeGe thin films on Ge(111) substrates, and confirm the generation of orbital moment in tensile-strained FeGe not seen in bulk or unstrained films. In-plane tensile strain resulted in an increase of the magnetic transition temperature to 350 K, likely the result of decreased Fe–Fe bond lengths that increase spin–orbit coupling strength. X-ray magnetic circular dichroism (XMCD) shows orbital-to-spin magnetic moment ratios of 0.18 and 0.14 for films of 18 nm and 72 nm thickness, respectively, indicative of partially quenched atomic orbitals. Finally, a very low effective Gilbert damping parameter, α eff = 0.003 ± 0.001 at room temperature was observed, suggesting that strained FeGe could be useful for spintronic applications.

36 MATERIALS SCIENCE↗

Electrical Detection of Spin-Hall-Induced Auto-oscillations in Lithium Aluminate Ferrite Thin Films

Ferrimagnetic insulators with ultralow damping are of great interest for their potential applications in energy-efficient computing devices. Here, we report the direct electrical detection of magnetic auto-oscillations in unpatterned ultralow damping ferrimagnetic insulator epitaxial Li 0.5 Al 0.5 Fe 2 O 4 thin films, driven by a current in a proximal Pt nanowire. Auto-oscillations occur for only one current polarity, consistent with the spin-Hall effect inducing the oscillation state. Micromagnetic modeling shows good agreement with the experimental frequency and field dispersions, showing only one dominant oscillation mode, in contrast to the multiple modes typically observed in transition-metal nanowire-type spin-Hall nanooscillators. This study illustrates a new material system for neuromorphic computing and magnonics, a simple material platform with the direct-current generation of high-frequency (~10 GHz) signals and their electrical detection.

36 MATERIALS SCIENCE↗