Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “explosion monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Ionizable-Substance Detector

Device that includes all conventional components of fuel cell and electrolyzer continuously monitors concentration of ionizable substance in stream of fluid without significantly disrupting flow or chemical composition. Among substances monitored are hydrogen, sodium, fluorine, chlorine, oxygen, and bromine. Useful in early detection of fluctuations, malfunctions, or hazards. Particularly useful for detecting hydrogen in stream of water in closed system containing oxygen, wherein concentration of hydrogen must not exceed given maximum, lest hydrogen react explosively with oxygen. Also used to monitor exhaust stream to comply with environmental-protection requirements.

Mcelroy, William↗

Local Leak Detection and Health Monitoring of Pressurized Tanks

An optical gas-detection sensor safely monitors pressurized systems (such as cryogenic tanks) and distribution systems for leaks. This sensor system is a fiber-coupled, solid optical body interferometer that allows for the miniaturized sensing element of the device to be placed in the smallest of recesses, and measures a wide range of gas species and densities (leaks). The deflection of the fringe pattern is detected and recorded to yield the time-varying gas density in the gap. This technology can be used by manufacturers or storage facilities with toxic, hazardous, or explosive gases. The approach is to monitor the change in the index of refraction associated with low-level gas leaks into a vacuum environment. The completion of this work will provide NASA with an enabling capability to detect gas system leaks in space, and to verify that pressurized systems are in a safe (i.e. non-leaking) condition during manned docking and transit operations. By recording the output of the sensor, a time-history of the leak can be constructed to indicate its severity. Project risk is mitigated by having several interferometric geometries and detection techniques available, each potentially leveraging hardware and lessons learned to enhance detectability.

Polzin, Kurt↗

Possible impacts of molten salt reactors on the International Monitoring System

Molten salt reactors (MSRs) are gaining support as many countries look for ways to increase power generation and replace aging nuclear energy production facilities. MSRs have inherently safe designs, are scalable in size, can burn transuranic wastes from traditional solid fuel nuclear reactors, can store excess heat in thermal reservoirs for water desalination, and can be used to produce medical isotopes as part of the real-time liquid-fuel recycling process. The ability to remove 135 Xe in real time from the fuel improves the power production in an MSR because 135 Xe is the most significant neutron-absorbing isotope generated by nuclear fission. Xenon-135, and other radioactive gases, are removed by sparging the fuel with an inert gas while the liquid fuel is recirculated from the reactor inner core through the heat exchangers. Without effective abatement technologies, large amounts of radioactive gas could be released during the sparging process. This work examines the potential impact of radioxenon releases on samplers used by the International Monitoring System (IMS) to detect nuclear explosions. Here, atmospheric transport simulations from seven hypothetical MSRs on different continents were used to evaluate the holdup time needed before release of radioxenon so IMS samplers would register few detections. Abatement technologies that retain radioxenon isotopes for at least 120 d before their release will be needed to mitigate the impacts from a molten salt breeder reactor used to replace a nuclear power plant. A holdup time of about 150 d is needed to reduce emissions to the average level of current nuclear power plants.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Mass Spectrometer Containing Multiple Fixed Collectors

A miniature mass spectrometer that incorporates features not typically found in prior mass spectrometers is undergoing development. This mass spectrometer is designed to simultaneously measure the relative concentrations of five gases (H2, He, N2, O2, and Ar) in air, over the relative-concentration range from 10(exp -6) to 1, during a sampling time as short as 1 second. It is intended to serve as a prototype of a product line of easy-to-use, portable, lightweight, highspeed, relatively inexpensive instruments for measuring concentrations of multiple chemical species in such diverse applications as detecting explosive or toxic chemicals in air, monitoring and controlling industrial processes, measuring concentrations of deliberately introduced isotopes in medical and biological investigations, and general environmental monitoring. The heart of this mass spectrometer is an integral combination of a circular cycloidal mass analyzer, multiple fixed ion collectors, and two mass-selective ion sources. By circular cycloidal mass analyzer is meant an analyzer that includes (1) two concentric circular cylindrical electrodes for applying a radial electric field and (2) a magnet arranged to impose a magnetic flux aligned predominantly along the cylindrical axis, so that ions, once accelerated into the annulus between the electrodes, move along circular cycloidal trajectories. As in other mass analyzers, trajectory of each ion is determined by its mass-to-charge ratio, and so ions of different species can be collected simultaneously by collectors (Faraday cups) at different locations intersected by the corresponding trajectories (see figure). Unlike in other mass analyzers, the installation of additional collectors to detect additional species does not necessitate increasing the overall size of the analyzer assembly.

Moskala, Robert↗

Advances in geophysical forensic event monitoring

Forensic analysis of man-made, non-nuclear events (such as industrial accidents, explosion experiments and mine collapses) has become more frequent and detailed owing to advancements in geophysical monitoring. Here, in this Technical Review, we demonstrate how geophysical forensic monitoring using seismic, infrasound and hydroacoustic recordings provides insights on events in the solid earth, atmosphere and underwater. Advanced techniques, including machine-learning-based models, have been developed to detect, identify and investigate these events, providing information on location, subevents, sources and explosive yield. The increase in data availability, application of advanced methods and computation and the growth of multitechnology approaches have increased the accuracy of forensic event analysis and enabled more realistic characterization of uncertainties. For example, the 2020 Beirut explosion in Lebanon demonstrated that various seismic, acoustic and other methods could be used to estimate explosive yield (and yield uncertainties) of about 1 ktonne, providing confidence in the application of these methods to smaller events where data are available. However, forensic investigations remain largely limited to known events with identified sources. Increased access to data, sophisticated analysis methods and high-resolution earth models will improve forensic event analysis further, enabling civil and scientific applications, such as localization in the search for the lost ARA San Juan submarine.

geophysics↗

Experimental and modelling study of the effect of pre-shock duration on the double shock initiation response of PBX 9501

Here, a series of double shock initiation gas-gun experiments have been performed on PBX 9501 (95% weight HMX, 5% binder) in which the input conditions were nominally the same, but the time delay between the two shocks was explicitly varied. The impact conditions generated pre- and main shock pressures of 2.9 and 6.2 GPa respectively, with time delays between them ranging from 0.56 to 1.10 µs. This resulted in different levels of reaction behind the pre-shock prior to the main shock traversing the explosive samples, with the growth of reaction monitored using embedded particle velocity and shock tracker gauges. Simulated results from three reactive burn models (CREST, AWSD and SURF) are compared with the measured data to assess their ability to predict the response of PBX 9501 under such double shock conditions. The described experiments add to the body of evidence to help improve our understanding of the double shock initiation response of explosives, and the data obtained provide an excellent test for reactive burn models.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Infrasound From a Buried Chemical Explosion Recorded on a Balloon in the Lower Stratosphere

Abstract Infrasound waveforms generated by natural and anthropogenic phenomena contain important clues about the size and nature of the event. We show that sensors on balloons in the lower stratosphere can record faithful representations of the near‐source acoustic wave field at unprecedented range. The acoustic signature of a buried chemical explosion recorded at a range of 56 km and an altitude of 21.8 km was nearly identical to that recorded on the ground 0.5 km from the epicenter, but absent on a ground sensor located 46 km away. Our results demonstrate that balloon‐borne infrasound techniques greatly increase the range at which well‐preserved acoustic representations of near‐source physics can be acquired, and that their propagation is simple to model. Our work has implications for monitoring remote regions of the earth for explosions, volcanic eruptions, and other phenomena. It also supports the prospect of balloon‐based infrasound seismology on Venus.

Bowman, Daniel C.↗

Partitioning of Radionuclides in Various Streams of the Mo-99 Purification Process

The Universal Neutron Irradiator (UNI) was designed to irradiate a small volume of uranium solution and to achieve high fission power without creating a large radionuclide (RN) inventory. The UNI system is equipped with a fully enclosed off-gas system with online hydrogen gas monitoring to prevent the production of an explosive atmosphere, as well as storage cylinders for capturing fission gases. It also includes a catalytic recombiner in the target capsule (to immediately recombine radiolytic hydrogen and oxygen gas in the system) and access ports for sampling the target solution and capsule headspace. In UNI Phase I experiments, 50 mL of uranyl sulfate solution was irradiated at 0.3–0.5 W/mL fission power using a tantalum target assembly to produce photoneutrons via irradiation with an electron beam. The purposes of the Phase I experiments were to test the efficacy of adding 200 ppm Fe 2+ to the target solution to prevent uranyl peroxide precipitation under representative irradiation conditions, and to monitor iodine speciation in the irradiated uranyl sulfate solution. The focus of the UNI Phase II experiments was to use an irradiated uranyl sulfate solution containing a mixture of fission products and monitor their distribution in various streams during the primary recovery column (titania-based column) that separates Mo-99 from uranium. Irradiations were designed to create sufficient activity for tracking their distribution in various processing streams using a combination of gamma counting and inductively coupled plasma mass spectrometry (ICP-MS) analyses. Obtained data will be used to better understand the composition of waste streams, accumulation of RN on the titania column, and identify what RNs accumulate in the uranyl sulfate solution. Furthermore, this knowledge will allow us to determine waste classifications for various streams produced during the Mo-99 purification process and develop an appropriate waste clean-up strategy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Environment Monitor

Viking landers touched down on Mars equipped with a variety of systems to conduct automated research, each carrying a compact but highly sophisticated instrument for analyzing Martian soil and atmosphere. Instrument called a Gas Chromatography/Mass Spectrometer (GC/MS) had to be small, lightweight, shock resistant, highly automated and extremely sensitive, yet require minimal electrical power. Viking Instruments Corporation commercialized this technology and targeted their primary market as environmental monitoring, especially toxic and hazardous waste site monitoring. Waste sites often contain chemicals in complex mixtures, and the conventional method of site characterization, taking samples on-site and sending them to a laboratory for analysis is time consuming and expensive. Other terrestrial applications are explosive detection in airports, drug detection, industrial air monitoring, medical metabolic monitoring and for military, chemical warfare agents.

Source record↗

Assessing the Accuracy of a Borehole-Controlled Velocity Model of Yucca Flat, Nevada, Using Large-N Seismic Data

The Source Physics Experiment (SPE) aims to improve nuclear test monitoring capabilities through a series of chemical explosions in Yucca Flat within the Nevada National Security Site (NNSS) (Snelson et al., 2013). With geologic data from over 950 boreholes, Yucca Flat has excellent borehole control on stratigraphy. These data were used to create a Geologic Framework Model (GFM) of the basin to aid in the study of seismic wave propagation through the Earth. However, the seismic velocities of the geologic units in the GFM are less well-defined. With the acquisition of five new active source Large-N datasets, we can now quantitatively assess the accuracy of the seismic model previously controlled by borehole data alone.

58 GEOSCIENCES↗

Explosive component acceptance tester using laser interferometer technology

Acceptance testing of explosive components requires a reliable and simple to use testing method that can discern less than optimal performance. For hot-wire detonators, traditional techniques use dent blocks or photographic diagnostic methods. More complicated approaches are avoided because of their inherent problems with setup and maintenance. A recently developed tester is based on using a laser interferometer to measure the velocity of flying plates accelerated by explosively actuated detonators. Unlike ordinary interferometers that monitor displacement of the test article, this device measures velocity directly and is commonly used with non-spectral surfaces. Most often referred to as the VISAR technique (Velocity Interferometer System for Any Reflecting Surface), it has become the most widely-accepted choice for accurate measurement of velocity in the range greater than 1 mm/micro-s. Traditional VISAR devices require extensive setup and adjustment and therefore are unacceptable in a production-testing environment. This paper describes a new VISAR approach which requires virtually no adjustments, yet provides data with accuracy comparable to the more complicated systems. The device, termed the Fixed-Cavity VISAR, is currently being developed to serve as a product verification tool for hot-wire detonators and slappers. An extensive data acquisition and analysis computer code was also created to automate the manipulation of raw data into final results.

Wickstrom, Richard D.↗

Expanded Very Large Array Nova Project Observations of the Classical NovaV1723 Aquilae

We present radio light curves and spectra of the classical nova VI723 Aql obtained with the Expanded Very Large Array (EVLA). This is the first paper to showcase results from the EVLA Nova Project, which comprises a team of observers and theorists utilizing the greatly enhanced sensitivity and frequency coverage of EVLA radio observations, along with observations at other wavelengths, to reach a deeper understanding of the energetics, morphology, and temporal characteristics of nova explosions. Our observations of VI723 Aql span 1-37 GHz in frequency, and we report on data from 14 to 175 days following the time of the nova explosion. The broad frequency coverage and frequent monitoring show that the radio behavior of VI723 Aql does not follow the classic Hubble-flow model of homologous spherically expanding thermal ejecta. The spectra are always at least partially optically thin, and the flux rises on faster timescales than can be reproduced with linear expansion. Therefore, any description of the underlying physical processes must go beyond this simple picture. The unusual spectral properties and light curve evolution might be explained by multiple emitting regions or shocked material. Indeed, X-ray observations from Swift reveal that shocks are likely present.

Krauss, Miriam I.↗

PAS: Privacy Algorithms in Systems

Today we face an explosion of data generation, ranging from health monitoring to national security infrastructure systems. More and more systems are connected to the Internet that collects data at regular time intervals. These systems share data and use machine learning methods for intelligent decisions, which resulted in numerous real-world applications (e.g., autonomous vehicles, recommendation systems, and heart-rate monitoring) that have benefited from it. However, these approaches are prone to identity thief and other privacy related cyber-security attacks. So, how can data privacy be protected efficiently in these scenarios? More dedicated efforts are needed to propose the integration of privacy techniques into existing systems and develop more advanced privacy techniques to address the complex challenges of multi-system connectivity and data fusion. Therefore, we have introduced Privacy Algorithms in Systems (PAS) at CIKM which provides a venue to gather academic researchers and industry researchers/practitioners to present their research in an effort to advance the frontier of this critical direction of privacy algorithms in systems.

Kotevska, Olivera↗

Examining the potential for detecting simultaneous noble gas and aerosol samples in the international monitoring system radionuclide network

The purpose of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) is to establish a legally binding ban on nuclear weapon test explosions or any other nuclear explosions. The Preparatory Commission for the CTBT Organization (CTBTO PrepCom) is developing the International Monitoring System (IMS) that includes a global network of 80 stations to monitor for airborne radionuclides upon entry into force of the CTBT. All 80 radionuclide stations will monitor for particulate radionuclides and at least half of the stations will monitor for radioxenon. The airborne radionuclide monitoring is an important verification technology both for the detection of a radionuclide release and in the determination of whether the release event originates from a nuclear explosion as opposed to an industrial use of nuclear materials. Nuclear power plants and many medical isotope production facilities release radioxenon into the atmosphere. Low levels of a few particulate isotopes, such as iodine, may also be released. Detections of multiple isotopes are useful for screening the radionuclide samples for relevance to the Treaty. This paper examines the anticipated joint detections in the IMS of noble gas and particulate isotopes from underground nuclear explosions where breaches in the underground containment vents from low levels to up to 1% of the radionuclide inventory of the resulting fission products to the atmosphere. Detection probabilities are based on 844 simulated release events spaced out at 17 release locations and one year in time. Six different release (venting) scenarios, including two fractionated scenarios, were analyzed. When ranked by detection probability, 11 particulate isotopes and one noble gas isotope ( 133 Xe) appear in the top 20 isotopes for all six release scenarios. Using the 11 particulate isotopes and the one noble gas isotope, the IMS has nearly the same detection probability as when 45 particulate and 4 noble gas isotopes are used. Thus, a limited list of relevant radionuclides may be sufficient for treaty verification purposes. The probability that at least one particulate and at least one radioxenon isotope would be detected in the IMS from the release events ranged from 0.15 to 0.86 depending on the release scenario.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Development of Direct Injection/Ionization Mass Spectrometry Methods for Whole Molecule Characterization

The objective of this work is to adapt ambient ionization mass spectrometry (AMS) techniques for the rapid analysis of intact uranium complexes, stable strontium, cerium, and explosive compounds. The methods used were “soft ionization” techniques, which facilitate the detection of whole molecule complexes. The soft ionization mass spectrometry (MS) techniques that were investigated include paper spray ionization (PSI), matrix-assisted ionization (MAI), electrospray ionization (ESI) and direct analysis in real time (DART). For the first time, PSI-MS methods were successfully developed for whole molecule uranium-containing analytes (uranyl acetate, uranyl nitrate, and uranyl-tributylphosphate complexes). This was also the first demonstration of uranium complex detection and characterization and one of the few examples of inorganic analysis using MAI techniques. Proof of concept experiments also putatively identified matrix-derived ions and ion complexes that have not previously been described in the literature. Additionally, PSI-MS on cotton swipe samples doped with a multi-element standard containing μg levels of U, Bi, Pb, Cd, Fe, and Zn were directly analyzed without purification, representing a major improvement over existing methods. Both PSI and MAI methods demonstrated limits of detection (LODs) in the 10 - 100’s ng for various uranyl species within a range of 10’s ppm - 100’s ppb, dependent on analytical method and analyte species. AMS methods were also developed for other inorganics, including Ce and Sr, and organic explosive residues to address specific challenges in environmental monitoring and forensics. Further refinement and qualification of the AMS techniques developed within this effort would lead to significant cost reduction and timeliness by facilitating the triage and queueing of samples for subsequent more sensitive and time-consuming analyses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonproliferation and Arms Control Research and Development (NPAC R&D) [Slides]

NPAC R&D focus areas include: Advancing U.S. capabilities to detect and characterize nuclear weapon development activities globally, including material production, the movement of special nuclear materials and nuclear weapons, and the testing or use of nuclear weapons, Supporting the development and testing of policy options and technical capabilities for international nuclear safeguards, arms control / treaty verification, nuclear export controls, and nonproliferation initiatives consistent with U.S. Government goals and objectives to enable monitoring and verification, Utilizing uranium, lithium, and high explosives (HE) materials expertise to support national-level activities in nuclear forensics and nuclear detection technology testing and evaluation, Providing unique training and capacity-building programs, particularly with the Nuclear Detection and Sensor Testing Center (NDSTC), and Engaging internationally to promote nonproliferation and arms control norms and best practices through bilateral and multilateral work.

36 MATERIALS SCIENCE↗

Incident Involving 30-Ah Li-ion Cell at NASA Glenn Research Center

The key lesson learned from the February 17, 2006 cell explosion incident is that PC-based test-systems, even those having built-in watchdog monitors, can lose control and malfunction. In the case of lithiumion cell/battery testing, the stored energy can be released explosively causing considerable injury and damage to facilities. The investigation showed that although the Arbin system has a built-in watchdog monitor, the circumstances of the incident defeated the action of the watchdog and allowed the cycler to continue operation without control. An upgrade to the most recent version of Arbin software (version 4) was provided as a fix to the presumed control problem. This upgrade included newer EPROM s for the cycler microprocessor. Investigation revealed that similar incidents have occurred at other NASA centers with a variety of PC-based test instruments. JPL suffered an incident with Maccor testers and the GRC fuel cell group observed similar problems with LabView software. This is not exclusively an Arbin problem, but an issue with all PC-based systems. In this incident, it was fortunate that the event occurred after-hours with no-one in the room. The facility arrangement placed control consoles adjacent to the test chamber doors. Had someone been in the room during the event, they would have been exposed to hot debris and toxic combustion products. It was also fortunate that the exploded cell stayed inside the chamber after the door was forced open. If the cell had been ejected into the room it could have caused serious facility damage by impact and possibly caused a fire in the facility.

Bennett, William↗

Swift Observations of Supernovae during and after Shock Breakout

Over the past few years, space-based observatories have allowed detailed studies of energetic supernova explosions in previously unexplored time domains and wavelength regimes. NASA's Swift observatory is playing an important role in probing the early emission of SNe during and after shock breakout due to its fast response, flexible scheduling capabilities, and large wavelength band coverage, ranging from the optical, W, and X-ray to the Gamma-ray bands. By studying the outgoing SN shocks with material in its surroundings, the explosion physics and nature of progenitor stars can be studied. Furthermore, monitoring the X-ray emission of SNe with space-based X-ray observatories is being used to map the density structure in SN environments out to large radii from the sites of the explosions (>E20 cm), the transition of a SN into an old supernova remnant can be studied, and the mass-loss rates of the progenitor stars are being probed over significant timescales (>E4 years) in the stellar wind history. In combination, these observations give unprecedented insights into the nature of energetic explosions and their environments. During this talk, I will present highlights from recent observations, among them the first observation of a SN DURING the actual explosion with Swift, and I will discuss the "naked eye" burst at a redshift of -1, which was the most distant object humans could ever see with their own eyes.

Immler, Stefan↗