Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error budgets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Leptonic B- and D-Meson Decay Constants with 2+1 Flavors of Asqtad Fermions

We present the status of our updated D- and B-meson decay-constant analysis, based on the MILC N f =2+1 asqtad gauge ensembles. Heavy quarks are incorporated using the Wilson clover action with the Fermilab interpretation. This analysis includes ensembles at five lattice spacings from α ≈ 0.045 to 0.15 fm, and light sea-quark masses down to 1/20 th of the strange-quark mass. Projected error budgets for ratios of decay constants, in particular between bottom- and charm-meson decay constants, are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Decay Constants $f_B$ and $f_{B_s}$ from HISQ Simulations

We give a progress report on a project aimed at a high-precision calculation of the decay constants $f_B$ and $f_{B_s}$ from simulations with HISQ heavy and light valence and sea quarks. Calculations are carried out with several heavy valence-quark masses on ensembles with 2+1+1 flavors of HISQ sea quarks at five lattice spacings and several light sea-quark mass ratios $m_{ud}/m_s$, including approximately physical sea-quark masses. This range of parameters provides excellent control of the continuum limit and of heavy-quark discretization errors. We present a preliminary error budget with projected uncertainties of 2.2~MeV and 1.5~MeV for $f_B$ and $f_{B_s}$, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutral B-Meson Mixing Parameters in and beyond the SM with 2+1 Flavor Lattice QCD

We report on the status of our calculation of the hadronic matrix elements for neutral $B$-meson mixing with asqtad sea and valence light quarks and using the Wilson clover action with the Fermilab interpretation for the $b$ quark. We calculate the matrix elements of all five local operators that contribute to neutral $B$-meson mixing both in and beyond the Standard Model. We use MILC ensembles with $N_f=2+1$ dynamical flavors at four different lattice spacings in the range $a \approx 0.045$--$0.12$~fm, and with light sea-quark masses as low as 0.05 times the physical strange quark mass. We perform a combined chiral-continuum extrapolation including the so-called wrong-spin contributions in simultaneous fits to the matrix elements of the five operators. We present a complete systematic error budget and conclude with an outlook for obtaining final results from this analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Update on a short-distance $D^0$-meson mixing calculation with $N_f=2+1$ flavors

We present an update on our calculation of the short-distance $D^0$-meson mixing hadronic matrix elements. The analysis is performed on the MILC collaboration's $N_f=2+1$ asqtad configurations. We use asqtad light valence quarks and the Sheikoleslami-Wohlert action with the Fermilab interpretation for the valence charm quark. SU(3), partially quenched, rooted, staggered heavy-meson chiral perturbation theory is used to extrapolate to the chiral-continuum limit. Systematic errors arising from the chiral-continuum extrapolation, heavy-quark discretization, and quark-mass uncertainties are folded into the statistical errors from the chiral-continuum fits with methods of Bayesian inference. A preliminary error budget for all five operators is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulation Study of Injection Performance for the Advanced Photon Source Upgrade

A vertical on-axis injection scheme has been proposed for the hybrid seven-bend-achromat (H7BA) [1] Advanced Photon Source upgrade (APSU) lattice. In order to evaluate the injection performance, various errors, such as injection beam jitter, optical mismatch and errors, and injection element errors have been investigated and their significance has been discovered. Injection efficiency is then simulated under different error levels. Based on these simulation results, specifications and an error-budget for individual systems have been defined.

Xiao, A.↗

A Diamond Micro-strip Electron Detector for Compton Polarimetry

The Qweak experiment in Hall C at Jefferson Lab aims to measure the weak charge of the proton with a precision of 4.1{\%} by measuring the parity violating asymmetry in polarized electron-proton elastic scattering. Beam polarimetry is the largest experimental contribution to the error budget. A new Compton polarimeter was installed for a non-invasive and continuous monitoring of the electron beam polarization with a goal of 1{\%} systematic and 1{\%} per hour statistical precision. The Compton-scattered electrons are detected in four planes of diamond micro-strip detectors. These detectors are read out using custom built electronic modules that include a pre-amplifier, a pulse shaping amplifier and a discriminator for each detector micro-strip. We use Field Programmable Gate Array based general purpose logic modules for event selection and histogramming. The polarimeter was commissioned during the first run period of the Qweak experiment. We will show the preliminary results from the electron detector obtained during the first run period of Qweak experiment.

Narayan, Amrendra↗

Performance of a MEMS-base Adaptive Optics Optical Coherency Tomography System

We have demonstrated that a microelectrical mechanical systems (MEMS) deformable mirror can be flattened to < 1 nm RMS within controllable spatial frequencies over a 9.2-mm aperture making it a viable option for high-contrast adaptive optics systems (also known as Extreme Adaptive Optics). The Extreme Adaptive Optics Testbed at UC Santa Cruz is being used to investigate and develop technologies for high-contrast imaging, especially wavefront control. A phase shifting diffraction interferometer (PSDI) measures wavefront errors with sub-nm precision and accuracy for metrology and wavefront control. Consistent flattening, required testing and characterization of the individual actuator response, including the effects of dead and low-response actuators. Stability and repeatability of the MEMS devices was also tested. An error budget for MEMS closed loop performance will summarize MEMS characterization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

$B^0_s$ and $B^0$ Mixing in the Standard Model and Beyond: A Progress Report

We give a progress report on the calculation of B meson mixing matrix elements, focusing on contributions that could arise beyond the Standard Model. The calculation uses asqtad (light quark) and Fermilab (heavy quark) valence actions and MILC ensembles with 2+1 flavors of asqtad sea quarks. We report preliminary B{sub s}{sup 0} fit results, at a lattice spacing of 0.12 fm, for the SUSY basis of effective four-quark mixing operators and include an estimate for the final error budget.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-T-09: In Phantom Full-Implant Validation of Plastic Scintillation Detectors for in Vivo Dosimetry During Low Dose Rate Brachytherapy

Purpose: To validate in a water phantom the use of plastic scintillation detectors to measure dose to the urethra and the rectal wall during a clinically realistic low dose rate (LDR) brachytherapy implant. Methods: A template was designed to replicate a clinically realistic LDR brachytherapy prostate implant inside a water phantom. Twenty-two catheters were inserted, including one mimicking the urethra and another the rectal wall. The needles inserted in the remaining 20 catheters were composed of thin-walled nylon tubes in which I-125 radioactive seeds (Air Kerma Strengths of (0.328±0.020)U) were abutted together with plastic spacers to replicate a typical loading. A plastic scintillation detector (PSD) with a 5-mm long × 1-mm diameter sensitive element was first placed inside the urethra and 1-second measurements were performed for 60s after each needle implant. Measurements were also performed at multiple positions along the urethra once all the needles were inserted. The procedure was then repeated with the PSD placed at the rectal wall. Results: Individual dose-rates ranging from 0.07µGy/s to 1.5µGy/s were measured after each needle implant. The average absolute relative differences were (6.2±3.6)% and (6.9±6.5)% to the values calculated with the TG-43 formalism, for the urethra and rectal wall respectively. These results are within expectations from the error uncertainty budget once accounting for uncertainties in seeds’ strength and positioning. Interestingly, the PSD allowed for unplanned error detection as the study was performed. Finally, the measured dose after the full implant at different positions along the mimicked organs at risk were in agreement with TG-43 values for all of the positions tested. Conclusion: Plastic scintillation detectors could be used as in vivo detectors for LDR brachytherapy as they would provide accurate dose information after each needle implant as well as along the organs at risk at the end of the implant.

60 APPLIED LIFE SCIENCES↗

A Systems Approach to Estimating the Uncertainty Limits of X-Ray Radiographic Metrology

Micro- and nanomanufacturing capabilities have rapidly expanded over the past decade to include complex three-dimensional (3D) structure fabrication; however, the metrology required to accurately assess these processes via part inspection and characterization has struggled to keep pace. X-ray computed tomography (CT) is considered an ideal candidate for providing the critically needed metrology on the smallest scales, especially internal features, or inaccessible regions. X-ray CT supporting micro- and nanomanufacturing often push against the poorly understood resolution and variation limits inherent to the machines, which can distort or hide fine structures. In this study, we have developed and experimentally verify a comprehensive analytical uncertainty propagation signal variation flow graph (SVFG) model for X-ray radiography in this work to better understand resolution and image variability limits on the small scale. The SVFG approach captures, quantifies, and predicts variations occurring in the system that limit metrology capabilities, particularly in the micro/nanodomain. This work is the first step to achieving full uncertainty modeling of CT reconstructions and provides insight into improving X-ray attenuation imaging systems. The SVFG methodology framework is applied to generate a complete basis set of functions describing the major sources of variation in radiographs. Five models are identified, covering variation in energy, intensity, length, blur, and position. Radiographic system experiments are defined to measure the parameters required by the SVFGs. Best practices are identified for these measurements. The SVFG models are confirmed via direct measurement of variation to predict variation within 30% on average.

47 OTHER INSTRUMENTATION↗

Neutron-skin uncertainties of Skyrme energy density functionals

Neutron-skin thickness is an excellent indicator of isovector properties of atomic nuclei. As such, it correlates strongly with observables in finite nuclei that depend on neutron-to-proton imbalance and the nuclear symmetry energy that characterizes the equation of state of neutron-rich matter. A rich worldwide experimental program involving studies with rare isotopes, parity-violating electron scattering, and astronomical observations is devoted to pinning down the isovector sector of nuclear models. We assess the theoretical systematic and statistical uncertainties of neutron-skin thickness and relate them to the equation of state of nuclear matter, and in particular to nuclear symmetry energy parameters. We use the nuclear superfluid density functional theory with several Skyrme energy density functionals and density dependent pairing. To evaluate statistical errors and their budget, we employ the statistical covariance technique. We find that the errors on neutron skin increase with neutron excess. Statistical errors due to uncertain coupling constants of the density functional are found to be larger than systematic errors, the latter not exceeding 0.06 fm in most neutron-rich nuclei across the nuclear landscape. The single major source of uncertainty is the poorly determined slope $L$ of the symmetry energy that parametrizes its density dependence. To provide essential constraints on the symmetry energy of the nuclear energy density functional, next-generation measurements of neutron skins are required to deliver precision better than 0.06 fm.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Subtropical Eastern North Pacific SST bias in earth system models

Karthik Balaguru (PNNL), Luke Van Roekel (LLNL), L. Ruby Leung (PNNL) and Milena Veneziani (LLNL) Abstract: This study systematically evaluates the warm SST bias in the Subtropical Eastern North Pacific (SENP), a problem plaguing most CMIP6 models, using the Energy Exascale Earth System Model version 1 (E3SM). Compared to the model at its standard resolution (1o atmosphere, 30-60 km ocean), the SST bias improves in several regions at high resolution (0.25o atmosphere, 18-6 km ocean) except in subtropical eastern boundary regions, such as the SENP. A mixed layer heat budget analysis reveals that errors in the surface radiative fluxes and horizontal heat advection are primarily responsible for the bias. Analysis of HighResMIP models indicates that the lack of improvement in the SENP SST bias with resolution is not native to E3SM alone. A larger CMIP6 inter-model correlation of SST bias with biases in surface winds than radiation highlights the important role of large-scale circulation biases in the SENP SST bias in coupled models.

Balaguru, Karthik↗

A Case Study Investigating the Low Summertime CAPE Behavior in the Global Forecast System

Convective available potential energy (CAPE) is an important index for storm forecasting. Recent versions (v15.2 and v16) of the Global Forecast System (GFS) predict lower values of CAPE during summertime in the continental United States than analysis and observation. We conducted an evaluation of the GFS in simulating summertime CAPE using an example from the Unified Forecast System Case Study collection to investigate the factors that lead to the low CAPE bias in GFS. Specifically, we investigated the surface energy budget, soil properties, and near-surface and upper-level meteorological fields. Results show that the GFS simulates smaller surface latent heat flux and larger surface sensible heat flux than the observations. This can be attributed to the slightly drier-than-observed soil moisture in the GFS that comes from an offline global land data assimilation system. The lower simulated CAPE in GFS v16 is related to the early drop of surface net radiation with excessive boundary layer cloud after midday when compared with GFS v15.2. A moisture-budget analysis indicates that errors in the large-scale advection of water vapor does not contribute to the dry bias in the GFS at low levels. Common Community Physics Package single-column model (SCM) experiments suggest that with realistic initial vertical profiles, SCM simulations generate a larger CAPE than runs with GFS IC. SCM runs with an active LSM tend to produce smaller CAPE than that with prescribed surface fluxes. Note that the findings are only applicable to this case study. Including more warm-season cases would enhance the generalizability of our findings.

54 ENVIRONMENTAL SCIENCES↗

Energy-conserving physics for nonhydrostatic dynamics in mass coordinate models

Abstract. Motivated by reducing errors in the energy budget related to enthalpy fluxes within the Energy Exascale Earth System Model (E3SM), we study several physics–dynamics coupling approaches. Using idealized physics, a moist rising bubble test case, and the E3SM's nonhydrostatic dynamical core, we consider unapproximated and approximated thermodynamics applied at constant pressure or constant volume. With the standard dynamics and physics time-split implementation, we describe how the constant-pressure and constant-volume approaches use different mechanisms to transform physics tendencies into dynamical motion and show that only the constant-volume approach is consistent with the underlying equations. Using time step convergence studies, we show that the two approaches both converge but to slightly different solutions. We reproduce the large inconsistencies between the energy flux internal to the model and the energy flux of precipitation when using approximate thermodynamics, which can only be removed by considering variable latent heats, both when computing the latent heating from phase change and when applying this heating to update the temperature. Finally, we show that in the nonhydrostatic case, for physics applied at constant pressure, the general relation that enthalpy is locally conserved no longer holds. In this case, the conserved quantity is enthalpy plus an additional term proportional to the difference between hydrostatic pressure and full pressure.

58 GEOSCIENCES↗

Quantifying Diurnal Cloud Radiative Effects by Cloud Type in the Tropical Western Pacific

Cloud radiative effects are examined using long-term datasets collected at the three Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facilities in the tropical western Pacific. We quantify the surface radiation budget, cloud populations, and cloud radiative effects by partitioning the data by cloud type, time of day, and as a function of large scale modes of variability such as El Niño Southern Oscillation (ENSO) phase and wet/dry seasons at Darwin. The novel facet of our analysis is that we break aggregate cloud radiative effects down by cloud type across the diurnal cycle. The Nauru cloud populations and subsequently the surface radiation budget are strongly impacted by ENSO variability whereas the cloud populations over Manus only shift slightly in response to changes in ENSO phase. The Darwin site exhibits large seasonal monsoon related variations. We show that while deeper convective clouds have a strong conditional influence on the radiation reaching the surface, their limited frequency reduces their aggregate radiative impact. The largest source of shortwave cloud radiative effects at all three sites comes from low clouds. We use the observations to demonstrate that potential model biases in the amplitude of the diurnal cycle and mean cloud frequency would lead to larger errors in the surface energy budget compared to biases in the timing of the diurnal cycle of cloud frequency. Our results provide solid benchmarks to evaluate model simulations of cloud radiative effects in the tropics.

54 ENVIRONMENTAL SCIENCES↗

Conserving Land–Atmosphere Synthesis Suite (CLASS)

Accurate estimates of terrestrial water and energy cycle components are needed to better understand climate processes and improve models’ ability to simulate future change. Various observational estimates are available for the individual budget terms; however, these typically show inconsistencies when combined in a budget. In this work, a Conserving Land–Atmosphere Synthesis Suite (CLASS) of estimates of simultaneously balanced surface water and energy budget components is developed. Individual CLASS variable datasets, where possible, 1) combine a range of existing variable product estimates, and hence overcome the limitations of estimates from a single source; 2) are observationally constrained with in situ measurements; 3) have uncertainty estimates that are consistent with their agreement with in situ observations; and 4) are consistent with each other by being able to solve the water and energy budgets simultaneously. First, available datasets of a budget variable are merged by implementing a weighting method that accounts both for the ability of datasets to match in situ measurements and the error covariance between datasets. Then, the budget terms are adjusted by applying an objective variational data assimilation technique (DAT) that enforces the simultaneous closure of the surface water and energy budgets linked through the equivalence of evapotranspiration and latent heat. Comparing component estimates before and after applying the DAT against in situ measurements of energy fluxes and streamflow showed that modified estimates agree better with in situ observations across various metrics, but also revealed some inconsistencies between water budget terms in June over the higher latitudes.

54 ENVIRONMENTAL SCIENCES↗

SALT2 versus SALT3: updated model surfaces and their impacts on type Ia supernova cosmology

ABSTRACT For the past decade, SALT2 has been the most common model used to fit Type Ia supernova (SN Ia) light curves for dark energy analyses. Recently, the SALT3 model was released, which upgraded a number of model features but has not yet been used for measurements of dark energy. Here, we evaluate the impact of switching from SALT2 to SALT3 for a SN cosmology analysis. We train SALT2 and SALT3 on an identical training sample of 1083 well-calibrated Type Ia supernovae, ensuring that any differences found come from the underlying model framework. We publicly release the results of this training (the SALT ‘surfaces’). We then run a cosmology analysis on the public Dark Energy Survey 3-Yr Supernova data sample (DES-SN3YR), and on realistic simulations of those data. We provide the first estimate of the SN + CMB systematic uncertainty arising from the choice of SALT model framework (i.e. SALT2 versus SALT3), Δw = + 0.001 ± 0.005 – a negligible effect at the current level of dark energy analyses. We also find that the updated surfaces are less sensitive to photometric calibration uncertainties than previous SALT2 surfaces, with the average spectral energy density dispersion reduced by a factor of two over optical wavelengths. This offers an opportunity to reduce the contribution of calibration errors to SN cosmology uncertainty budgets.

79 ASTRONOMY AND ASTROPHYSICS↗