Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy conservation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Physics-preserving enriched Galerkin method for a fully-coupled thermo-poroelasticity model

This paper proposes a new numerical method for a fully-coupled, quasi-static thermo-poroelasticity model in a unified enriched Galerkin (EG) method framework. In our method, the mechanics sub-problem is solved using a locking-free EG method, and the flow and heat sub-problems are solved using a locally-conservative EG method. The proposed method offers mass and energy conservation properties with much lower costs than other methods with the same properties, including discontinuous Galerkin methods and mixed finite element methods. The well-posedness and optimal a priori error estimates are carefully derived. Here, several numerical tests confirm the theoretical optimal convergence rates and the mass and energy conservation properties of the new method.

15 GEOTHERMAL ENERGY↗

Energy and Water Management

Energy efficiency isn't just a good idea; it's a necessity, both for cost reasons and to meet federal regulatory requirements. First, rising energy unit costs continue to erode NASA's mission budget. NASA spent roughly $156M on facility energy in FY 2007. Although that represents less than one per cent of NASA's overall annual budget, the upward trend in energy costs concerns the agency. While NASA reduced consumption 13%, energy unit costs have risen 63%. Energy cost increases counteract the effects of energy conservation, which results in NASA buying less yet spending more. The second factor is federal energy legislation. The National Energy Conservation Policy Act, as amended by the Energy Policy Act of 2005, Executive Order (EO) 13423 (January, 2007), and the Energy Independence and Security Act (December, 2007), mandates energy/water conservation goals for all federal agencies, including NASA. There are also reporting requirements associated with this legislation. The Energy/Water Management Task was created to support NASA Headquarters Environmental Management Division (HO EMD) in meeting these requirements. With assistance from TEERM, HQ EMD compiled and submitted the NASA Annual Report to the Department of Energy FY 2007. The report contains information on how NASA is meeting federally mandated energy and water management goals. TEERM monitored input for timeliness, errors, and conformity to the new energy/water reporting guidelines and helped compile the information into the final report. TEERM also assists NASA Energy/Water Management with proposal and award calls, updates to the energy/water management database, and facilitating communication within the energy/water management community. TEERM is also supporting NASA and the Interagency Working Group (IWG) on Hydrogen and Fuel Cells. Established shortly after the President announced the Hydrogen Fuel Initiative in 2003, this IWG serves as the mechanism for collaboration among the Federal agencies involved in hydrogen-related research, development, and demonstration. TEERM developed a matrix showing all Hydrogen and Fuel Cell activities from the various NASA centers to be included in the Group's extensive hydrogen research taxonomy of past, present, and future hydrogen activities of the Federal government.

Valek, Susan E.↗

A pseudospectral implicit particle-in-cell method with exact energy and charge conservation

The standard particle-in-cell (PIC) method employs explicit finite-difference (FD) methods (e.g. the leap-frog scheme) for both spatial and temporal integrations. Here, we employ a pseudospectral method for solving the Poisson equation and a fully implicit time integration to achieve exact energy conservation. The advantage of a pseudospectral field solver is its spectral accuracy in solving field solutions. Earlier studies of implicit time integration of PIC FD equations can enforce exact energy exchange between field and particles, resulting in exact energy-conserving schemes. Here, we prove that the exact energy conservation property can be carried over to the pseudospectral scheme. Simultaneously, we provide a solution to ensure a pseudospectral charge continuity equation. We demonstrate the new scheme in a 2D electrostatic PIC code. In conclusion, theoretical results are confirmed via numerical examples.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lorentz Symmetry Group, Retardation and Energy Transformations in a Relativistic Engine

In a previous paper, we have shown that Newton’s third law cannot strictly hold in a distributed system of which the different parts are at a finite distance from each other. This is due to the finite speed of signal propagation which cannot exceed the speed of light in vacuum, which in turn means that when summing the total force in the system the force does not add up to zero. This was demonstrated in a specific example of two current loops with time dependent currents, the above analysis led to suggestion of a relativistic engine. Since the system is effected by a total force for a finite period of time this means that the system acquires mechanical momentum and energy, the question then arises how can we accommodate the law of momentum and energy conservation. The subject of momentum conservation was discussed in a pervious paper, while preliminary results regarding energy conservation where discussed in some additional papers. Here we give a complete analysis of the exchange of energy between the mechanical part of the relativistic engine and the field part, the energy radiated from the relativistic engine is also discussed. We show that the relativistic engine effect on the energy is 4th-order in 1c and no lower order relativistic engine effect on the energy exists.

42 ENGINEERING↗

An Energetic Concept of Habitability for the Deep Subsurface

Universally, life must be characterized by a characteristic level of order and complexity. In the most general sense, habitability could then be defined as the set of factors required to allow the creation and maintenance of molecular complexity. These factors are: chemical raw materials; energy with which to assemble those materials into complex molecules and sustain the resultant state of complexity; a solvent that allows the interaction of complex molecules, promotes tertiary structure, and permits compartmentalization; and environmental conditions that permit the assembly and maintenance of complex molecules. On Earth, these general requirements correspond to the major biogenic elements C, H, O, N, P, S; chemical or light energy; the solvent water; and specific ranges of temperature, pH, radiation, ionic strength, and so forth, which have thus far been determined on and exclusively empirical basis. Importantly, while the complete absence of any of these factors ensures uninhabitable conditions, the mere presence of all four does not guarantee habitability. In each case - even that of water - it is a question of degree. This question can be couched in quantitative terms by considering the impact of each of these factors on cellular energy balance. More "extreme" conditions (e.g., high temperature, high or low pH, etc.), lower water activity, and low concentrations of nutrients incur or have potential to be addressed by increased investment of energy on the part of the cell. This must be balanced by energy conservation in the cell, noting that biochemical, mass transport, and abiotic chemical limitations intervene between environmental energy availability and biological energy capture. Similarly, lower boundary conditions are emplaced on useful environmental energy yields by the "quantized" nature of biological energy conservation, and upper boundary conditions are emplaced by energy levels or fluxes that are destructive with respect to complexity. This energetic framework, with boundary conditions supplied by the specifics of the biochemistry in question, offers a generalized, yet quantitative means of assessing the habitability of any system with respect to complex life.

Hoehler, Tori M.↗

Commercial, industrial, and institutional discount rate estimation for efficiency standards analysis: Sector-level data 1998–2022

Underlying each of the U.S. Department of Energy’s (DOE’s) federal appliance and equipment energy conservation standards are a set of complex analyses of the projected costs and benefits of regulation. Any new or amended standard must be designed to achieve significant additional energy conservation, provided that it is technologically feasible and economically justified (42 U.S.C. 6295(o)(2)(A)). DOE determines economic justification based on whether the benefits exceed the burdens, considering a variety of factors, including the economic impact of the standard on consumers of the product and the savings in lifetime operating cost compared to any increase in price or maintenance expenses (42 U.S.C. 6295(o)(2)(B)). As part of this determination, DOE conducts a life-cycle cost (LCC) analysis, which models the combined impact of appliance first cost and operating cost changes on a representative commercial building sample to identify the fraction of customers achieving LCC savings or incurring net cost at the considered efficiency levels. Thus, the commercial discount rate value(s) used to calculate the present value of energy cost savings within the LCC model implicitly plays a role in estimating the economic impact of potential standard levels. This report provides an in-depth discussion of the commercial discount rate estimation process. It is an update to previous reports on estimating commercial discount rates from firm-level and sector-level financial data (e.g., Fujita, 2021, 2016). Major topics covered in this report include the following: -Discount rate estimation methods and rationale -Data sources used and data limitations -Discount rate distributions for use in standards analysis -Discount rate estimation methods and distributions specific to the small business subgroup analysis A version of this analysis was most recently released in 2022. Going forward, this report will be updated as data allow and analyses necessitate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial, industrial, and institutional discount rate estimation for efficiency standards analysis: Sector-level data 1998–2023

Underlying each of the U.S. Department of Energy’s (DOE’s) federal appliance and equipment energy conservation standards are a set of complex analyses of the projected costs and benefits of regulation. Any new or amended standard must be designed to achieve significant additional energy conservation, provided that it is technologically feasible and economically justified (42 U.S.C. 6295(o)(2)(A)). DOE determines economic justification based on whether the benefits exceed the burdens, considering a variety of factors, including the economic impact of the standard on consumers of the product and the savings in lifetime operating cost compared to any increase in price or maintenance expenses (42 U.S.C. 6295(o)(2)(B)). As part of this determination, DOE conducts a life-cycle cost (LCC) analysis, which models the combined impact of appliance first cost and operating cost changes on a representative commercial building sample to identify the fraction of customers achieving LCC savings or incurring net cost at the considered efficiency levels. Thus, the commercial discount rate value(s) used to calculate the present value of energy cost savings within the LCC model implicitly plays a role in estimating the economic impact of potential standard levels. This report provides an in-depth discussion of the commercial discount rate estimation process relying on the Capital Asset Pricing Model (CAPM) to estimate a business’ cost of equity, and by adding a risk adjustment factor to the risk-free rate associated with long-term U.S. Treasury bonds to estimate their cost of debt. It is an update to previous reports on estimating commercial discount rates from firm-level and sector-level financial data (e.g., Fujita, 2021, 2016). Major topics covered in this report include the following: • Discount rate estimation methods and rationale • Data sources used and data limitations • Discount rate distributions for use in standards analysis • Discount rate estimation methods and distributions specific to the small business subgroup analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial, industrial, and institutional discount rate estimation for efficiency standards analysis: Sector-level data 1998–2021

Underlying each of the Department of Energy’s (DOE’s) federal appliance and equipment energy conservation standards are a set of complex analyses of the projected costs and benefits of regulation. Any new or amended standard must be designed to achieve significant additional energy conservation, provided that it is technologically feasible and economically justified (42 U.S.C. 6295(o)(2)(A)). DOE determines economic justification based on whether the benefits exceed the burdens, considering a variety of factors, including the economic impact of the standard on consumers of the product and the savings in lifetime operating cost compared to any increase in price or maintenance expenses (42 U.S.C. 6295(o)(2)(B)). As part of this determination, DOE conducts a Life-Cycle Cost (LCC) analysis, which models the combined impact of appliance first cost and operating cost changes on a representative commercial building sample in order to identify the fraction of customers achieving LCC savings or incurring net cost at the considered efficiency levels. Thus, the commercial discount rate value(s) used to calculate the present value of energy cost savings within the LCC model implicitly plays a role in estimating the economic impact of potential standard levels. This report provides an in-depth discussion of the commercial discount rate estimation process. It is an update to previous reports on estimating commercial discount rates from firm-level financial data (Fujita, 2016). Major topics covered in this report include: Discount rate estimation methods and rationale; -Data sources used and data limitations; -Discount rate distributions for use in standards analysis; -Discount rate estimation methods and distributions specific to the small business subgroup analysis. Going forward, this report will be updated as data allow and analyses necessitate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TeV Neutrinos and Hard X-Rays from Relativistic Reconnection in the Corona of NGC 1068

Abstract The recent discovery of astrophysical neutrinos from the Seyfert galaxy NGC 1068 suggests the presence of nonthermal protons within a compact “coronal” region close to the central black hole. The acceleration mechanism of these nonthermal protons remains elusive. We show that a large-scale magnetic reconnection layer, of the order of a few gravitational radii, may provide such a mechanism. In such a scenario, rough energy equipartition between magnetic fields, X-ray photons, and nonthermal protons is established in the reconnection region. Motivated by recent 3D particle-in-cell simulations of relativistic reconnection, we assume that the spectrum of accelerated protons is a broken power law, with the break energy being constrained by energy conservation (i.e., the energy density of accelerated protons is at most comparable to the magnetic energy density). The proton spectrum is dn p / dE p ∝ E p − 1 below the break and dn p / dE p ∝ E p − s above the break, with IceCube neutrino observations suggesting s ≃ 3. Protons above the break lose most of their energy within the reconnection layer via photohadronic collisions with the coronal X-rays, producing a neutrino signal in good agreement with the recent observations. Gamma rays injected in photohadronic collisions are cascaded to lower energies, sustaining the population of electron–positron pairs that makes the corona moderately Compton thick.

Astronomy & Astrophysics↗

Energy Requirements of Hydrogen-Utilizing Microbes: Boundary Condition for Subsurface Life

For planetary bodies with surface conditions that are too harsh to permit continuous occupation by life, the deep subsurface offers a potentially stable and habitable niche. For organisms occupying this niche, the spectrum of possible metabolisms must be limited to those which do not include sunlight as an energy source or oxygen as a chemical reagent - generally, low-energy anaerobic oxidation-reduction processes. The quantity of energy released in such processes is critical, because currently understood mechanisms of biological energy conservation indicate that energy is only 'useful' to an organism when it is available at a certain minimum level - the 'biological energy quantum'. The mere existence of a BEQ implies that a significant fraction of the chemical energy present in the environment cannot be exploited by life; similarly, the absolute magnitude of the BEQ must be a key variable in determining the potential viability and distribution of subsurface microbial communities. Laboratory culture studies suggest that organisms require an energy of about -20 kJ/mol to grow. However, we find that hydrogen-utilizing microorganisms in an energy-limited natural ecosystem are active with energy yields as low as -10 kJ/mol. A lower BEQ would mean a significantly expanded range of energetically viable subsurface habitat for life.

Hoehler, Tori M.↗

Addressing key physics problems in high-energy-density plasmas with a novel kinetic simulation capability

Many important physical processes in inertial confinement fusion (ICF) and dense Z-pinch (DZP) experiments require a kinetic (velocity-space-dependent) description. Conventional particle-in-cell (PIC) methods are poorly suited for high-energy-density (HED) plasmas, due to restrictive time-step constraints and the inability to conserve energy. In a previous LDRD (21-FS-048), we demonstrated that a fully implicit PIC formulation overcomes these limitations: it conserves energy even when coupled with Coulomb collision models and can be solved efficiently with large grid cells and large time steps. Thus, it is feasible to use this method to study kinetic effects in ICF and DZP plasmas on hydro-like time and spatial scales. In this follow-on LDRD, we advanced this methodology into a high-fidelity tool for production-scale simulations and used it to answer key questions relevant to ICF and DZP experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Input-output analysis of some sector actions

Selected energy conservation actions previously discussed in depth but separately in the areas of the energy industry, the industry sector, the transportation sector, and the residential and commercial sector, were brought together and assessed as a group. Particular emphasis was devoted to identifying secondary or indirect impacts and multiple interactions. Preliminary results obtained from the ECASTAR energy input-output model suggest that the impacts of energy conservation actions can be grossly misrepresented if secondary impacts are not included in the assessment. A methodology which stresses the importance of secondary and multiple interactions permeates the underlying philosophy of this discussion.

Source record↗

A Review of Non-Regulatory Energy Efficiency Measures in the United States

Increasing energy efficiency is ubiquitous in many economies, and several mechanisms for achieving this increase, from mandatory policies to voluntary initiatives, have been proposed and implemented. In the United States, the Department of Energy, during the development of its energy conservation standard rules, evaluates the benefits from several of these mechanisms. In this report, we review how estimates of benefits from two types of voluntary energy efficiency initiatives – rebates and voluntary energy efficiency targets (VETs) – compare to the same benefits estimated for minimum energy efficiency standards (MEPS) established in the United States for residential appliances, commercial and industrial equipment, and lighting applications (referred to simply as “products” for the remainder of this report) between 2010 and 2020. Our results show that, overall, these two voluntary measures are estimated to provide, altogether, 36% of the total energy savings estimated to be provided by new efficiency standards, with a total net-present value that corresponds to 52% of the net-present value estimated for standards. When considering all energy conservation rules reviewed in this report, the energy savings a rebate program is estimated to achieve ranges from less than 1% to 86% of the savings from new standards set for the same type of product and at the same level of energy efficiency. As for VETs, the energy savings range from less than 1% to 78% of the savings from standards. Results vary widely across types of products due to (a) the relevance of the monetary incentive relative to incremental upfront costs considered for each type of product, and (b) the estimated level of market barriers associated with each type of product. While voluntary energy efficiency initiatives are not as effective as MEPS in transforming the market and raising the bar of energy efficiency for energy consuming goods in an economy, when applied in tandem with MEPS they can be powerful instruments for promoting and increasing energy efficiency in the economy.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Carl T. Hayden Veterans Affairs Medical Center: Smart Buildings Case Study

The purpose of this smart buildings case study is to showcase a leading example of a GEB renovation project in the federal buildings space and provide key information on the technology and control upgrades, costs, and energy and utility bill savings. This case study also provides information and recommendations for selecting energy conservation measures (ECMs) and choosing energy and cost reduction strategies from the energy management team at the site. The findings from this successful GEB project can be used to help pave the way for additional GEB retrofits in the future. The Carl T. Hayden Veterans Affairs (VA) Medical Center in Phoenix, Arizona, demonstrates that GEB strategies and technologies can be realistically deployed today across buildings with substantial energy and cost savings. The project implemented both ECMs and grid-interactive technologies and controls strategies, making it a leading example of a smart, sustainable, and efficient commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Conservation: Toward firmer ground

The following aspects of energy conservation were reviewed in order to place the problems in proper perspective: history and goals, conservation accounting-criteria, and a method to overcome obstacles. The effect of changing prices and available supplies of energy sources and their causes on consumption levels during the last few decades were described. Some examples of attainable conservation goals were listed and justified. A number of specific criteria applicable to conservation accounting were given. Finally, a discussion was presented to relate together the following aspects of energy conservation: widespread impact, involvement of government, industry, politics, moral and ethical aspects, urgency and time element.

Source record↗

Elastic Wave Propagation in Curvilinear Coordinates with Mesh Refinement Interfaces by a Fourth Order Finite Difference Method

In this work, we develop a fourth order accurate finite difference method for the three dimensional elastic wave equation in isotropic media with the piecewise smooth material property. In our model, the material property can be discontinuous at curved interfaces. The governing equations are discretized in second order form on curvilinear meshes by using a fourth order finite difference operator satisfying a summation-by-parts property. The method is energy stable and high order accurate. The highlight is that mesh sizes can be chosen according to the velocity structure of the material so that computational efficiency is improved. At the mesh refinement interfaces with hanging nodes, physical interface conditions are imposed by using ghost points and interpolation. With a fourth order predictor-corrector time integrator, the fully discrete scheme is energy conserving. Numerical experiments are presented to verify the fourth order convergence rate and the energy conserving property.

58 GEOSCIENCES↗

ECASTAR systems approach

The methodology of ECASTAR was presented and a discussion of the application of technology to energy conservation was given. This methodology constitutes an overview and blueprint for the analysis of energy conservation actions, and is subdivided into the following sections: the systems approach, constraints and criteria, application of the method (systems approach display, ECASTAR team, study phases and objectives, requirements and impacts, trade-off, integration, and feedback), an example of the method (technology applications).

Source record↗

Asymptotic-preserving gyrokinetic implicit particle-orbit integrator for arbitrary electromagnetic fields

We extend the asymptotic preserving and energy conserving time integrator for charged-particle motion developed in Ricketson and Chacón (2020) to include finite Larmor-radius (FLR) effects in the presence of electric-field length-scales comparable to the particle gyro-radius (the gyro-kinetic limit). We introduce two modifications to the earlier scheme. The first is the explicit gyro-averaging of the electric field at the half time-step, along with an analogous modification to the current deposition, which we show preserves total energy conservation in implicit PIC schemes. The number of gyrophase samples is chosen adaptively, ensuring proper averaging for large timesteps and the recovery of full-orbit dynamics in the small time-step limit. The second modification is an alternating large and small time-step strategy that ensures the particle trajectory samples gyrophases evenly. We show that this strategy relaxes the time-step restrictions on the scheme, allowing even larger speed-ups than previously achievable. We demonstrate the new method with several single-particle motion tests in a variety of electromagnetic field configurations featuring gyro-scale variation in the electric field. Finally, the results demonstrate the advertised ability to capture FLR effects accurately even when significantly stepping over the gyration time-scale.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗