Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “emittance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Temperature Distributions in Hollow Cathode Emitters

Life-limiting processes in hollow cathodes are determined largely by the temperature of the emitter. To support development of cathode life models we have developed a noncontact temperature measurement technique which employs a stepper motor-driven fiber optic probe. The probe is driven inside the hollow cathode and collects light radiated by the hot interior surface of the emitter. Ratio pyrometry is used determine the axial temperature profile. Thermocouples on the orifice plate provide measurements ofthe external temperature during cathode operation and are used to calibrate the pyrometer system in situ with a small oven enclosing the externally heated cathode. Initial measurements of the temperature distribution in a hollow cathode with the same geometry as a cathode that failed after operating at 12 A emission current for 27800 hours are discussed.

ratio pyrometer system↗

Systems and Methods for Implementing Robust Carbon Nanotube-Based Field Emitters

Systems and methods in accordance with embodiments of the invention implement carbon nanotube-based field emitters. In one embodiment, a method of fabricating a carbon nanotube field emitter includes: patterning a substrate with a catalyst, where the substrate has thereon disposed a diffusion barrier layer; growing a plurality of carbon nanotubes on at least a portion of the patterned catalyst; and heating the substrate to an extent where it begins to soften such that at least a portion of at least one carbon nanotube becomes enveloped by the softened substrate.

Manohara, Harish↗

Cryogenic Thermal Emittance Measurements on Small-Diameter Stainless Steel Tubing

The Mid Infrared Instrument aboard the James Webb Space Telescoep includes a mechanical cryocooler which cools its detectors to their 6 K operating temperature. The refrigerant flows through several meters of approximately 2 mm diameter 304L stainless steel tubing, with some sections gold plated, and some not, which are exposed to their environment. An issue of water freezing onto the tube surfaces is mitigated by a running a warm gas through the lines to sublimate the water. To model the effect of this process on nearby instruments, an accurate measure of the tube emittance is needed. Previously we reported the abosprtance of the gold plated stainless steel tubing as a function of source temperature (i.e. its environment). In this work the thermal emittance of the uncoated tubing is measured as a function of its temperature between 100 and 300 K. This value leads to an accurate prediction of the minimum length of time required to thermally recycle the system. We report the technique and present the results.

cryogenic↗

Cryogenic Thermal Emittance Measurements on Small-Diameter Stainless Steel Tubing

The Mid Infrared Instrument aboard the James Webb Space Telescope includes a mechanical cryocooler which cools its detectors to their 6 K operating temperature. The refrigerant flows through several meters of 2 mm diameter 304L stainless steel tubing, with some sections gold plated, and some not, which are exposed to their environment. An issue of water freezing onto the tube surfaces is mitigated by running a warm gas through the lines to sublimate the frozen water. To model the effect of this process on nearby instruments, an accurate measure of the tube emittance is needed. Previously we reported the absorptance of the gold plated stainless steel tubing as a function of source temperature (i.e. its environment). In this work the thermal emittance of the uncoated tubing is measured as a function of its temperature between 100 and 280 K. These values lead to an accurate prediction of the minimum length of time required to thermally recycle the system. We report the technique and present the results.

stainless steel↗

A Large, Deep 3 Deg2 Survey of Hα, [OIII], and [OII] Emitters from LAGER: Constraining Luminosity Functions

We present our measurements of the Hα, [OIII], and [O II] luminosity functions as part of the Lyman Alpha Galaxies at Epoch of Reionization (LAGER) survey using our samples of 1577 z=0.47Hα-, 3933 z=0.93 [O III]-, and 5367 z=1.59 [O II]-selected emission line galaxies in a 3 deg2 single, CTIO/Blanco DECam pointing of the COSMOS field. Our observations reach 5σ depths of 8.2 × 10−18 erg s−1 cm−2 and comoving volumes of (1−7) × 105 Mpc3 making our survey one of the deepest narrow-band surveys. We select our emission line galaxies via spectroscopic confirmation, photometric redshifts, and colour–colour selections. We measure the observed luminosity functions for each sample and find best fits of φ* = 10−3.16+0.09 −0.09 Mpc−3and L* = 1041.72+0.09 −0.09 erg s−1 for Hα, φ* = 10−2.16+0.10−0.12 Mpc−3 and L* = 1041.38+0.07 −0.06 erg s−1 for [O III], and φ* = 10−1.97+0.07−0.07 Mpc−3 and L* = 1041.66+0.03−0.03 erg s−1 for [OII], with α fixed to −1.75, −1.6, and −1.3, respectively. An excess of bright >1042 erg s−1 [O III] emitters is observed and may be due to active galactic nucleus (AGN) contamination. Corrections for dust attenuation are applied assuming AHα = 1 mag. We also design our own empirical restframe g − r calibration using SDSS DR12 data, test it against our z = 0.47 Hα emitters with zCOSMOS 1D spectra, and calibrate it for (g − r) between −0.8 and 1.3 mag. Dust and AGN corrected star formation rate densities (SFRDs) are measured as log10ρSFR/(Msun yr−1 Mpc−3)=−1.63 ± 0.04, −1.07 ± 0.06, and −0.90 ± 0.10 for Hα, [OIII], and [O II], respectively. We find our [O III] and [O II] samples fully trace cosmic star formation activity at their respective redshifts in comparison to multiwavelength SFRDs, while the Hα sample traces ∼70 per cent of the total z = 0.47 SFRD.

galaxies↗

Emitter Surface Temperature Measurements of a 25-A class Hollow Cathode

Measurements of the emitter surface temperature of a hollow cathode were made using an optical ratio pyrometer. These measurements were performed to provide insight into the effect of various cathode operating parameters on emitter surface peak temperature and temperature distribution

Hollow Cathode↗

Field Emitter Cathodes and Electric Propulsion Systems

Replacing hollow and filament cathodes with field emitter (FE) cathodes could significantly improve the scalability, power, and performance of some meso- and microscale Electric Propulsion (EP) systems. This article discusses the motivation and challenges of integrating of FE and Electric Propulsion systems.

field emitters cathodes Electric Propulsion↗

Electric Propulsion Applications for Field Emitter Cathodes

Replacing hollow and filament cathodes with field emitter (FE) cathodes could significantly improve the scalability, power, and performance of some meso- and microscale Electric Propulsion (EP) systems.

Field emitters cathodes electric propulsion↗