Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Sub-Poissonian light and photocurrent shot-noise suppression in closed opto-electronic loop

We examine experimentally photocurrent noise reduction in the opto-electronic closed loop. Photocurrent noise density 12.5 dB below the shot-noise was observed. So large suppression was not reached in previous experiments and cannot be explained in terms of an ordinary sub-Poissonian light in the loop. We propose the concept of anticorrelation state for the description of light in the loop.

Masalov, A. V.↗

Ultra-low-noise cryogenic high-electron-mobility transistors

Quarter-micrometer gate-length high-electron-mobility transistors (HEMTs) for cryogenic low-noise application with very low light sensitivity have been developed. At room temperature, these exhibit a noise figure of 0.4 dB with associated gain of 15 dB at 8 GHz. At a temperature of 12.5 K the minimum noise temperature of 5.3 +/- 1.5 K has been measured at 8.5 GHz, which is the best noise performance observed to date for any microwave transistors. The results clearly demonstrate the potential for low-temperature low-noise applications.

Duh, K. H. George↗

Electrostatic noise bands associated with the electron gyrofrequency and plasma frequency in the outer magnetosphere

Naturally occurring noise bands near the electron plasma frequency are frequently detected by the University of Iowa plasma wave experiment on the Imp 6 satellite in the region from just inside the plasmapause to radial distances of about 10 earth radii in the outer magnetosphere. The electric field strength of these noise bands is usually small with typical broad band electric field strengths of about 2 microvolts per m. A magnetic field has been detected only in a few unusually intense cases, and in these cases the magnetic field energy density is several orders of magnitude smaller than the electric field energy density. The bands are observed at all magnetic latitudes covered by the Imp 6 orbit and appear to be a permanent feature of the outer magnetosphere. They are found at all local times and occur least frequently in the quadrant from 18 to 24 hours. The bands appear to consist of two distinct spectral types called diffuse and narrow band. In both types the center frequency of the noise band is bounded by consecutive harmonics of the electron gyrofrequency, and these noise bands occur most often between harmonics that are near the local electron plasma frequency.

Shaw, R. R.↗

Ultra-Fast Electron Microscopic Imaging of Single Molecules With a Direct Electron Detection Camera and Noise Reduction

Time-resolved imaging of molecules and materials made of light elements is an emerging field of transmission electron microscopy (TEM), and the recent development of direct electron detection cameras, capable of taking as many as 1,600 fps, has potentially broadened the scope of the time-resolved TEM imaging in chemistry and nanotechnology. However, such a high frame rate reduces electron dose per frame, lowers the signal-to-noise ratio (SNR), and renders the molecular images practically invisible. Here, we examined image noise reduction to take the best advantage of fast cameras and concluded that the Chambolle total variation denoising algorithm is the method of choice, as illustrated for imaging of a molecule in the 1D hollow space of a carbon nanotube with ~1 ms time resolution. Through the systematic comparison of the performance of multiple denoising algorithms, we found that the Chambolle algorithm improves the SNR by more than an order of magnitude when applied to TEM images taken at a low electron dose as required for imaging at around 1,000 fps. Open-source code and a standalone application to apply Chambolle denoising to TEM images and video frames are available for download.

47 OTHER INSTRUMENTATION↗

Excess noise in high-current diamond diodes

We report the results of an investigation of low-frequency excess noise in high-current diamond diodes. It was found that the electronic excess noise of the diamond diodes is dominated by the 1/f and generation-recombination noise, which reveals itself as Lorentzian spectral features (f is the frequency). The generation-recombination bulges are characteristic of diamond diodes with lower turn-on voltages. The noise spectral density dependence on forward current, I, reveals three distinctive regions in all examined devices—it scales as I 2 at the low (I < 10 μA) and high (I > 10 mA) currents and, rather unusually, remains nearly constant at the intermediate current range. The characteristic trap time constants, extracted from the noise data, show a uniquely strong dependence on current. Interestingly, the performance of the diamond diodes improves with the increasing temperature. The obtained results are important for the development of noise spectroscopy-based approaches for device reliability assessment for high-power diamond electronics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

EDFA-based coupled opto-electronic oscillator and its phase noise

EDFA-based coupled opto-electronic oscillator (COEO), an integrated optical and microwave oscillator that can generate picosecond optical pulses, is presented. the phase noise measurements of COEO show better performance than synthesizer-driven mode-locked laser.

mode-locked laser↗

ELF noise bands associated with auroral electron precipitation.

Observation of a new type of ELF noise band that is closely associated with low-energy auroral electron precipitation. These observations have been made at relatively low altitudes (less than 3000 km) with the polar-orbiting satellite Injun 5. The noise bands typically have a center frequency of 100 to 300 Hz and often appear to consist of many nearly monochromatic bursts, typically of a few seconds' duration, superimposed to produce the observed noise band. These ELF noise bands are observed only in a relatively narrow range of latitudes (a few degrees) in the auroral zone and are almost always associated with intense fluxes of precipitating electrons with energies from a few hundred electron volts to several kiloelectron volts. On the dayside of the magnetosphere the region where the ELF noise bands and the associated low-energy electron precipitation are observed has been identified as the polar cusp. In considering the possible explanations of these ELF noise bands, it is noted that the spectral characteristics of this noise are very similar to a type of narrowband electromagnetic noise called 'lion's roar,' which has been observed at much higher altitudes in the magnetosheath with the satellite Ogo 5. It is suggested that the ELF noise bands observed at low altitudes with Injun 5 are caused by lion's roar emissions that have propagated down 'open' magnetic-field lines to low altitudes from the magnetosheath region.

Gurnett, D. A.↗

Low-Noise Wide Bandwith, Hot Electron Bolometer Mixers for Submillimeter Wavelengths

Recently a novel superconductive hot-electron micro-bolometer has been proposed which is both fast and sensitive (D. E. Prober, Appl. Phys. Lett. 62, 2119, 1993). This device has several important properties which make it useful as a heterodyne sensor for radioastronomy applications at frequencies above 1 THz. The thermal response time of the device is fast enough, several 10's of picoseconds, to allow for IF's of several GHz. This bolometer mixer should operate well up to at least 10 THz. There is no energy gap limitation as in an SIS mixer, since the mixing process relies on heating of the electron gas. In fact, rf power is absorbed more uniformly above the gap frequency. The mixer noise should be near quantum-limited, and the local oscillator (LO) power requirement is very low: / 10 nW for a Nb device. One of the unique features of this device is that it employs rapid electron diffusion into a normal metal, rather than phonon emission, as the thermal conductance that cools the heated electrons. In order for diffusion to dominate over phonon emission, the device must be short, less than 0.5.

Bolometer Mixers↗

Probes for measuring noise current in an electronic cable

Electromagnetic interference in deep-space network receiver is often caused by stray coupling from power lines. These stray signals create potential differences between ground terminals, which leads to excessive noise in receiver circuits. Pair of probes detect and measure noise currents in conductors.

Lundy, C. C.↗

Magnetospheric electron density measurements from upper hybrid resonance noise observed by IMP-6

A band of natural radio noise between the local electron plasma frequency and the upper hybrid resonance frequency is observed by the IMP-6 satellite. The band exists over a large range of geocentric radial distances extending from inside the plasmapause boundary to greater than 10 earth radii in the outer magnetosphere. The center frequency of the noise band decreases with increasing radial distance, and changes abruptly at the plasmapause boundary. The broadband electric field strength of this noise is very small, seldom exceeding 10 microvolts/meter, and probably could not be detected without using long electric antennas of IMP-6. It is believed that this noise is produced by incoherent Cerenkov emission from super-thermal electrons. In some cases a second very narrow noise band was observed at a frequency slightly above the second harmonic of the electron gyrofrequency.

Shaw, R. R.↗

Electron diffusion in microbunched electron cooling

Coherent electron cooling is a novel method to cool dense hadron beams on timescales of a few hours. This method uses a copropagating beam of electrons to pick up the density fluctuations within the hadron beam in one straight section and then provides corrective energy kicks to the hadrons in a downstream straight, cooling the beam. Microbunched electron cooling is an extension of this idea, which induces a microbunching instability in the electron beam as it travels between the two straights, amplifying the signal. However, initial noise in the electron bunch will also be amplified, providing random kicks to the hadrons downstream which tend to increase their emittance. In this paper, we develop an analytic estimate of the effect of the electron noise and benchmark it against simulations. We also discuss how this effect has impacted the cooler design. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cryogenic switched MOSFET characterization

Both p channel and n channel enhancement mode MOSFETs can be readily switched on and off at temperatures as low as 2.8 K so that switch sampled readout of a VLWIR Ge:Ga focal plane is electronically possible. Noise levels as low as 100 rms electrons per sample (independent of sample rate) can be achieved using existing p channel MOSFETs, at overall rates up to 30,000 samples/second per multiplexed channel (e.g., 32 detectors at a rate of almost 1,000 frames/second). Run of the mill devices, including very low power dissipation n channel FETs would still permit noise levels of the order of 500 electrons/sample.

Source record↗

Imaging atomic-scale chemistry from fused multi-modal electron microscopy

Efforts to map atomic-scale chemistry at low doses with minimal noise using electron microscopes are fundamentally limited by inelastic interactions. Here, fused multi-modal electron microscopy offers high signal-to-noise ratio (SNR) recovery of material chemistry at nano- and atomic-resolution by coupling correlated information encoded within both elastic scattering (high-angle annular dark-field (HAADF)) and inelastic spectroscopic signals (electron energy loss (EELS) or energy-dispersive x-ray (EDX)). By linking these simultaneously acquired signals, or modalities, the chemical distribution within nanomaterials can be imaged at significantly lower doses with existing detector hardware. In many cases, the dose requirements can be reduced by over one order of magnitude. This high SNR recovery of chemistry is tested against simulated and experimental atomic resolution data of heterogeneous nanomaterials.

36 MATERIALS SCIENCE↗

Wavelength Calibration of the Full-sun Ultraviolet Rocket SpecTrograph: (FURST)

The Sun has a well-known periodicity in sunspot number and magnetic field variation. The underlying cause of this 11-year cycle is not fully understood and has yet to be connected with those processes in other stellar objects. The Full-sun Ultraviolet Rocket SpecTrograph (FURST) is a sounding rocket payload being developed by Montana State University (MSU) alongside the Marshall Space Flight Center (MSFC) solar physics group. Scheduled to launch from White Sands Missile Range (WSMR) in 2022, this instrument is unique in that it will provide the connection between stellar observatories with measurements of our Sun. It will achieve this through extremely high-resolution full-disk spectroscopy in EUV. We aim to obtain a wavelength resolution R > 10,000 in the 115 - 181 nm range, on par with that of the Hubble (HST) Space Telescope Imaging Spectrograph (STIS). The Lyman Alpha line (121 nm) is known to oversaturate most CCD electronics and is of particular challenge for this spectral range. In addition, this resolution goal will allow us to study the 3 km/s motion (a Doppler-shift of about 0.01 Angstroms) of the relatively low-temperature plasma in the chromosphere and lower corona. This paper will present the results of our simulation of the diagnostic lamp signal to be used in this wavelength calibration. To test the viability of this precise of a device, we are building a collimator capable of calibrating the FURST instrument under these strict radiometric requirements. By way of a diagnostic lamp simulation, we will account for photon noise, CCD electronic readout noise, and statistical error. These will lead to the development of our pre- and post-launch calibration plan. Future work includes absolute radiometric and wavelength calibration with this new collimator. In addition, the ability of FURST to measure extremely small Doppler-shifts will provide capabilities for planetary atmospheric scientists. This impact is coupled with the diverse international partnership created by the closely-knit Sounding Rocket teams across the globe. These Sounding Rockets have an even broader impact, as they encourage future satellite missions under the prospect of long-term observations.

FURST↗

Noise suppression for MHD characterization with electron cyclotron emission imaging 1D technique

Significant noise suppression for magnetohydrodynamics (MHD) mode characterization in the spatial and spectral domain is achieved by processing two-dimensional (2D) electron cyclotron emission imaging (ECEI) data with a one-dimensional (1D) ECEI technique using a short time window ($1\;{\text{ms}}$). The technique is applied to detect toroidal Alfven eigenmodes (TAEs) in the temporal spectrum and fit their radial envelope using the data from the DIII-D tokamak W-band 2D ECEI system. Using the data length (time window) of only 1 ${\text{ms}}$, the 1D ECEI can clearly detect the TAEs (~100 ${\text{kHz}}$) on the spectrum, while similar spectrum quality requires ~10 ${\text{ms}}$ data length with the cross power spectrum between two midplane ECEI channels. The 1D ECEI technique also effectively avoids biased fitting when resolving the fine structure of the TAE's radial envelope. The radially spatial resolution of 1D ECEI is constrained by the finite ECE radiation volume of the ECEI receiver. Here, with forward radiation modeling, we find the DIII-D ECEI system can sensitively measure the even parity MHD activities, for which the mode width is >15 mm, and tearing modes (odd parity MHD activities), for which the island full width is >30 mm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗