Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Simple and Scalable Streaming: The GRETA Data Pipeline

The Gamma Ray Energy Tracking Array (GRETA) is a state of the art gamma-ray spectrometer being built at Lawrence Berkeley National Laboratory to be first sited at the Facility for Rare Isotope Beams (FRIB) at Michigan State University. A key design requirement for the spectrometer is to perform gamma-ray tracking in near real time. To meet this requirement we have used an inline, streaming approach to signal processing in the GRETA data acquisition system, using a GPU-equipped computing cluster. The data stream will reach 480 thousand events per second at an aggregate data rate of 4 gigabytes per second at full design capacity. We have been able to simplify the architecture of the streaming system greatly by interfacing the FPGA-based detector electronics with the computing cluster using standard network technology. A set of highperformance software components to implement queuing, flow control, event processing and event building have been developed, all in a streaming environment which matches detector performance. Prototypes of all high-performance components have been completed and meet design specifications.

Cromaz, Mario↗

Determining Latitudinal Extent of Energetic Electron Precipitation Using MEPED On-Board NOAA/POES

Energetic Electron Precipitation (EEP) from the plasma sheet and the radiation belts ionizes the polar lower thermosphere and mesosphere. EEP increases the production of NO x and HO x , which will catalytically destroy ozone, an important element of atmospheric dynamics. Therefore, measurement of the latitudinal extent of the precipitation boundaries is important in quantifying the atmospheric effects of the Sun-Earth interaction. This study uses measurements by the Medium Energy Proton Electron Detector (MEPED) of six NOAA/POES and EUMETSAT/METOP satellites from 2004 to 2014 to determine the latitudinal boundaries of EEP and their variability with geomagnetic activity and solar wind drivers. Variation of the boundaries for different electron energies and Magnetic Local Time (MLT) is studied. Regression analyses are applied to determine the best predictor variable based on solar wind parameters and geomagnetic indices. The highest correlation was found for the pressure-corrected Dst index when applying a linear regression model. A model of the equatorward EEP boundary is developed separately for three different energy channels, >43, >114, and >292 keV, and for 3 hour MLT sectors. For >43 keV EEP, 80% of the equatorward boundaries predicted by the model are within ±2.2° cgmlat. The model exhibits a solar cycle bias where it systematically exaggerates the equatorward movement of the EEP region during solar minimum. The highest accuracy of the model is found in periods dominated by corotating interaction regions/high speed solar wind streams. The result will be a key element for constructing a model of EEP variability to be applied in atmosphere climate models.

E. M. Babu↗

Experiment definition and integration study for the accommodation of giant, passive detector of Exotic Particles In the Cosmic Rays (EPIC) payload on shuttle/spacelab missions

The feasibility of the design, construction, launch and retrieval of a hinged 15 ft by 110 ft the platform containing an array of interleaved CR-39 and Lexan track-recording detectors to be placed into circular orbit by space shuttle is assessed. The total weight of the detector assembly plus supporting structure and accessories is 32,000 pounds. The modular construction permits as little as one fourth of the payload to be exposed at one time. The CR-39 detector has sensitivity adequate to detect and study cosmic rays ranging from minimum ionizing iron-group nuclei to the heaviest elements. The detectors will survive a one year exposure to trapped protons without losing their high resolution. Advantages include low cost, huge collecting power (approximately 150 sq m) as well as the high resolution previously attainable only with electronic detectors.

Price, P. B.↗

DE 1 and Viking observations associated with electron conical distributions

Data from the electron detectors on board the Swedish Viking satellite launched during a period of low solar activity and from the Dynamic Explorer (DE) 1 satellite launched during active solar coditions have been examined for the occurrence and location of electron conical distributions and several conclusions can be drawn. First, we note that most of the best examples of electron conics observed by the V-3 experiment onboard Viking occurred in the afternoon sector in the range of magneitc local time 14 hours less than Magnetic Local Time (MLT) less than 18 hours, at midaltitudes in the range 10,000 km less than h less than 13,500 km, with few occurring in the nightside auroral region, a region poorly sampled at altitudes greater than 5000 km. For the Viking data there is an association of electron conics with upper hybrid waves. DE 1 observations made by the high-altitude plasma instrument (HAPI) indicate that electron conics were observed in the midmorning sector and the late evening sector, and as has been reported earlier, the correlation with upper hybird waves was good. The HAPI did not sample the afternoon sector. The electon conics observed on both satellites occurred in the presence of at least a modest (several kilovolts) potential difference beneath the satellite with a maximum energy that was usually, but not always, equal to or greater than the maximum energy of the electron conics. Two independent sets of observations by DE 1 suggest two distinct production mechanisms for electron conics. Examiniation of DE 1 electric field measurements from the plasma wave instrument during the observation of electron conics show simultaneous parallel oscillations in the frequency range of 0.2 Hz less than f less than 0.5 Hz during one and perhaps two of four events examined, and upper hybrid waves were observed on all four events. In addition, recent observations of '90-deg' electron conics associated with auroral kilometric radiation source regions suggest a perpendicular heating mechanism produced by wave-particle interaction. Such distributions may be observed as electron conics at higher altitudes. These results suggest more than one possible source mechanism may be responsible for electron conics.

Menietti, J. D.↗

Design and performance of a magnetic bottle electron spectrometer for high-energy photoelectron spectroscopy

We describe the design and performance of a magnetic bottle electron spectrometer (MBES) for high-energy electron spectroscopy. Our design features a 2 m long electron drift tube and electrostatic retardation lens, achieving sub-electronvolt (eV) electron kinetic energy resolution for high energy (several hundred eV) electrons with a close to 4π collection solid angle. A segmented anode electron detector enables the simultaneous collection of photoelectron spectra in high resolution and high collection efficiency modes. This versatile instrument is installed at the time-resolved molecular and optical sciences instrument at the Linac Coherent Light Source x-ray free-electron laser (XFEL). In this paper, we demonstrate its high resolution, collection efficiency, and spatial selectivity in measurements where it is coupled to an XFEL source. These combined characteristics are designed to enable high-resolution time-resolved measurements using x-ray photoelectron, absorption, and Auger–Meitner spectroscopy. We also describe the pervasive artifact in MBES time-of-flight spectra that arises from a periodic modulation in electron collection efficiency and present a robust analysis procedure for its removal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary Design of a New Pulsed-Neutron Die--Away Experiments with Absorbers (IER-552 CED-1)

This report presents the preliminary design (CED-1) of IER-552, pulsed-neutron die-away (PNDA) experiments with absorbers, to be conducted by Lawrence Livermore National Laboratory (LLNL). The goal of the PNDA experiments with absorbing materials is to produce high-quality, low-cost integral benchmarks that can be used to validate cross sections that are high priority nuclear data for the Department of Energy’s Nuclear Criticality Safety Program (NCSP). PNDA experiments can be used to generate nuclear data validation benchmarks quickly and cheaply, as they do not require fissile material or a nuclear facility to conduct them. The original PNDA experiments were set up at LLNL under IER-501. Extending the PNDA experiments to include absorbing materials leverages existing facilities and resources at LLNL to validate cross sections, with a basic experiment design that uses a neutron generator to impinge a short, mono-energetic neutron pulse on a poisoned, moderating target sample. The neutron pulse lasts 100 µs, after which the neutron population in the sample reaches thermal equilibrium and later spatial equilibrium. In this fully equilibrized state, the neutron population has a characteristic decay-time eigenvalue. The eigenvalue can be used as an integral parameter to validate nuclear data involved with neutron scattering and absorption. Two observables can be measured: the neutron population and the population of secondary γ-rays produced by inelastic and capture reactions. This report explores the feasibility of both approaches. For γ-ray measurements, this allows for direct measurement of reactions of interest for validation. During the neutron burst time, inelastic (prompt) γ-rays dominate, and these data can be isolated for validation of neutron inelastic scattering data. After the pulse ends, neutron capture (delayed) γ-rays dominate and are produced by many reaction channels as neutrons slow down to thermal energies. Two sets of γ-ray spectra (inelastic, capture) can be produced for validation. Additionally, the time-dependent decay of the capture γ-ray population when the neutron population is thermalized and in its fundamental mode can be used for validation. Two experiments can be imagined where pulsed neutrons are used to validate the nuclear data of absorbing materials. The first integrates well into the existing PNDA testbed at LLNL. The absorber material would be introduced into a moderating target and the same neutron generator, neutron detectors, electronics, and shielding box used for IER-501 would be employed. From the same experimental setup, many absorbing materials can be validated by simply changing the neutron poison in the moderator. The only significant modification would be the introduction of a γ-ray detector. Such an experiment would primarily serve to validate nuclear data in the thermal energy range. The second kind of experiment would validate the fast and epithermal energy range. It would involve pulsing neutron into a bare assembly of the absorber material and measuring the die-away of neutrons. The fast leakage of such an assembly requires nanosecond neutron-generator pulse widths and fast detectors/electronics that could measure ~200 ns die-away curves. This kind of experiment would ideally be performed at a cyclotron, like that available at Lawrence Berkeley National Laboratory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Television observations of artificial aurora and analyses of flight data from NASA payload 12.18 NE

An accelerator nominally capable of ejecting pulses of electrons up to 6 sec in length, current to 500 ma and energy to 20 keV was flown on a rocket at 1500 October 15, 1972. The Strypi rocket was launched from the Pacific Missile Range Facility at Kauai, Hawaii. The intent was to eject electron pulses of various characteristics upwards along the magnetic field so as to produce artificial auroras in the conjugate (Southern Hemisphere) atmosphere and possibly to produce weaker auroras in the nearby atmosphere as a consequence of backscattered electrons. The accelerator package included a gas jet actuated attitude control system controlled by gyros. Attitude sensing also was accomplished by a two-axis fluxgate magnetometer, and a large foil was deployed to collect ambient electrons to neutralize the accelerator when it ejected high-energy electrons. Scientific instrumentation contained on the flight package included retarding potential analyzers, energetic electron detectors, and detectors to sense very low frequency radio noise. Image orthicon television systems and other optical sensors were operated in the conjugate region aboard two NC-135 jet aircrafts based in Samoa. Similar devices were operated at Haleakala, Hawaii, to attempt detection of auroras caused by backscattered electrons.

Davis, T. N.↗

Aperture plane potential control for thermal ion measurements

The effects produced by the addition of an aperture plane to control the bias around an instrument for low-energy ion measurements on satellites collecting data in the plasmasphere and over the polar cap are analyzed. The analysis is based on the design and functions of the retarding ion mass spectrometer (RIMS) on the DE 1 satellite. The NASA Charging Analyzer Program, which treats the spacecraft as a cylinder, was used to generate one set of predictions. A second model involves solution of the Laplace equation with the spacecraft treated as a sphere. Both models were used to predict the barrier height expected at the aperture in response to the bias induced to offset the potential. Comparisons with plasma data show that in the thin sheath regime of the plasmasphere the detectors act as if the potential is shifted, thereby lowering the energy resolution of the instrument. Outside the plasmasphere the barrier height dominates the spin curve variations more than the potential. Partial potential control is available from induced bias apertures if control is active and guided by electron detectors with sensitivities in the 0.5-50.0 eV energy range.

Olsen, R. C.↗

Design of the ECCE detector for the Electron Ion Collider

The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been designed to address the full scope of the proposed Electron Ion Collider (EIC) physics program as presented by the National Academy of Science and provide a deeper understanding of the quark-gluon structure of matter. To accomplish this, the ECCE detector offers nearly acceptance and energy coverage along with excellent tracking and particle identification. The ECCE detector was designed to be built within the budget envelope set out by the EIC project while simultaneously managing cost and schedule risks. Finally, this detector concept has been selected to be the basis for the EIC project detector.

47 OTHER INSTRUMENTATION↗

Exploring the Predictability of the High-Energy Tail of MEE Precipitation Based on Solar Wind Properties

Medium Energy Electron (MEE) precipitation (≳30 keV) ionizes the mesosphere and initiates chemical reactions, which ultimately can reduce mesospheric and stratospheric ozone. Currently, there are considerable differences in how existing parameterizations represent flux response, timing, and duration of MEE precipitation, especially considering its high-energy tail (≳300 keV). This study compares the nature of ≳300 to ≳30 keV electron fluxes to better understand differences within MEE precipitation. The MEE fluxes are estimated from measurements by the Medium Energy Proton and Electron Detector (MEPED) onboard the Polar Orbiting Environmental Satellite (POES) from 2004 to 2014. The fluxes are explored in the context of solar wind drivers: corotating high-speed solar wind streams (HSSs) and coronal mass ejections (CMEs) alongside their associated solar wind properties. Three key aspects of ≳300 keV electron fluxes are investigated: maximum response, peak timing, and duration. The results reveal a structure-dependent correlation (0.89) between the peak fluxes of ≳30 and ≳300 keV electrons. The epsilon coupling function correlates well (0.84) with the ≳300 keV peak flux, independent of solar wind structure. The ≳300 keV flux peaks 0–3 days after the ≳30 keV flux peaks. The highest probability (∼42%) occurs for a 1-day delay, while predictive capabilities increase when accounting for solar wind speed. The ≳300 keV flux response has the highest probability of lasting 4 days for both CMEs and HSSs. The results form a base for a stochastic MEE parameterization that goes beyond the average picture, enabling realistic flux variability on both daily and decadal scales.

J A Salice↗

The Voyager Cosmic Ray Experiment

The Voyager Cosmic Ray Experiment includes seven dE/dx-E telescopes to measure the energy and charge of particles with atomic numbers from 1 to 26 in the energy range 1-500 MeV/nucleon and to measure electron energy in the range from 3 to 110 MeV. Isotopic composition of hydrogen through sulfur in the range up to 75 Mev/nucleon can also be resolved. The electronic systems include a dual-gain, charge sensitive preamplifier, 4096-channel pulse height analyzers for three parameter analysis of selected events, and an event type readout polling scheme to maximize the use of available telemetry space and to enhance the occurrence of rare events in the data. Details of the detector, electronic and mechanical design are presented.

Stilwell, D. E.↗

SINGLE: Atomic-resolution structure identification of nanocrystals by graphene liquid cell EM

Analysis of the three-dimensional (3D) structures of nanocrystals with solution-phase transmission electron microscopy is beginning to reveal their unique physiochemical properties. We developed a “one-particle Brownian 3D reconstruction method” based on imaging of ensembles of colloidal nanocrystals using graphene liquid cell electron microscopy. Projection images of differently rotated nanocrystals are acquired using a direct electron detector with high temporal (<2.5 ms) resolution and analyzed to obtain an ensemble of 3D reconstructions. Here, we introduce computational methods required for successful atomic-resolution 3D reconstruction: (i) tracking of the individual particles throughout the time series, (ii) subtraction of the interfering background of the graphene liquid cell, (iii) identification and rejection of low-quality images, and (iv) tailored strategies for 2D/3D alignment and averaging that differ from those used in biological cryo–electron microscopy. Our developments are made available through the open-source software package SINGLE.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterizing defect structures in AM steel using direct electron detection EBSD

The mechanical properties of additive and traditionally manufactured alloys are largely dependent on the characteristics and distribution of dislocation cell networks that develop during the fabrication process. This work demonstrates the ability to quantitatively characterize these dislocation structures by high angular resolution electron backscatter diffraction analysis using a direct electron detector. The defect structures are characterized in terms of the geometrically necessary dislocation density and the associated Burgers vector and line direction. Furthermore, the results are discussed in terms of potential defect formation mechanisms.

36 MATERIALS SCIENCE↗

Electron microscopy holdings of the Protein Data Bank: the impact of the resolution revolution, new validation tools, and implications for the future

Abstract As a discipline, structural biology has been transformed by the three-dimensional electron microscopy (3DEM) “Resolution Revolution” made possible by convergence of robust cryo-preservation of vitrified biological materials, sample handling systems, and measurement stages operating a liquid nitrogen temperature, improvements in electron optics that preserve phase information at the atomic level, direct electron detectors (DEDs), high-speed computing with graphics processing units, and rapid advances in data acquisition and processing software. 3DEM structure information (atomic coordinates and related metadata) are archived in the open-access Protein Data Bank (PDB), which currently holds more than 11,000 3DEM structures of proteins and nucleic acids, and their complexes with one another and small-molecule ligands (~ 6% of the archive). Underlying experimental data (3DEM density maps and related metadata) are stored in the Electron Microscopy Data Bank (EMDB), which currently holds more than 21,000 3DEM density maps. After describing the history of the PDB and the Worldwide Protein Data Bank (wwPDB) partnership, which jointly manages both the PDB and EMDB archives, this review examines the origins of the resolution revolution and analyzes its impact on structural biology viewed through the lens of PDB holdings. Six areas of focus exemplifying the impact of 3DEM across the biosciences are discussed in detail (icosahedral viruses, ribosomes, integral membrane proteins, SARS-CoV-2 spike proteins, cryogenic electron tomography, and integrative structure determination combining 3DEM with complementary biophysical measurement techniques), followed by a review of 3DEM structure validation by the wwPDB that underscores the importance of community engagement.

Burley, Stephen K. (ORCID:0000000224879713)↗

A signal packet router for the upgrade of the Muon spectrometer at the ATLAS experiment

Here, we present the design, characterization, and production of a signal packet router for the upgrade of the ATLAS forward muon detector. The router serves as a packet switch in one of the primary trigger paths. It handles up to 12 serial inputs at 4.8 Gbps/input from on-detector electronics and outputs four 4.8 Gbps to the trigger processing circuits. In the 12-to-4 packet switching process, the input streams are decoded and synchronized to a common clock domain for data packets forwarding and NULL packets suppression. Challenges in the design include operations of multi-giga hertz serial links with low and constant latency (<100 ns) for packet routing, as well as mitigation of radiation-induced effects in the harsh radiation environment over 10 years of detector operation. The Router design has been fully characterized and demonstrated to meet all specifications. In total 256 Routers were installed in the detector. Its design concept can be used in other similar applications, particularly in a radiation environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Energetic Electron Fluxes Measured by GPS and THEMIS Spacecraft in the Inner Magnetosphere

Key elements of space weather models are energetic electron fluxes in the inner magnetosphere and the outer radiation belt. Flux depletion is driven by various loss processes: scattering into atmosphere, magnetopause shadowing. Flux enhancement is driven by various acceleration processes: local wave-particle interactions, radial transport, plasma sheet injections. Many of these processes operate on ~ hour timescales. Such mesoscale flux variations are not well traced by equatorial spacecraft with much longer orbits. Energetic electron detectors onboard the Global Positioning System (GPS) constellation provide a unique opportunity for probing such ~ hour-scale flux variations. Measurements from up to 23 identically instrumented GPS satellites cover a wide energy and L-shell range with a subhour time resolution. However, their orbits are inclined and thus all measurements at L-shell >4.3 are off-equatorial. Here, in this report, we present a comparison of equatorial THEMIS and nonequatorial GPS measurements of omnidirectional ≤600 keV electron fluxes. Such a comparison allows us to derive coefficients for using off-equatorial GPS fluxes to infer the equatorial values. These coefficients depend on particle energy and L-shell. We demonstrate a new data set derived from GPS measurements and discuss how it can be used to investigate mesoscale dynamics of energetic electron fluxes in the inner magnetosphere.

79 ASTRONOMY AND ASTROPHYSICS↗

High-latitude troughs and the polar cap boundary

OGO 6 observations of troughs in the thermal plasma densities in the topside ionosphere are discussed. Ion mass spectrometer measurements were correlated with energetic electron detector and electric field measurements. It is shown that the variation of ion composition at high latitudes is complex and frequently characterized by mid-latitude and high-latitude density depression. Prominent high-latitude troughs in the atomic ion (H, He, O) distributions were seen to lie frequently near the polar cap boundary. This indicates that these troughs are unrelated to the plasmapause which is found on closed magnetic field lines away from the trapping boundary. The production of the high-latitude troughs is shown to be related to enhancements in the soft electron flux and/or to the convection electric field.

Grebowsky, J. M.↗