Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron density”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Use of generalized population ratios to obtain Fe XV line intensities and linewidths at high electron densities

A generalized method for obtaining individual level population ratios is used to obtain relative intensities of extreme ultraviolet Fe XV emission lines in the range 284-500 A, which are density dependent for electron densities in the tokamak regime or higher. Four lines in particular are found to attain quite high intensities in the high-density limit. The same calculation provides inelastic contributions to linewidths. The method connects level populations and level widths through total probabilities t(ij), related to 'taboo' probabilities of Markov chain theory. The t(ij) are here evaluated for a real atomic system, being therefore of potential interest to random-walk theorists who have been limited to idealized systems characterized by simplified transition schemes.

Kastner, S. O.↗

Quantitative electron density characterization of soft tissue substitute plastic materials using grating-based x-ray phase-contrast imaging

Many scientific research areas rely on accurate electron density characterization of various materials. For instance in X-ray optics and radiation therapy, there is a need for a fast and reliable technique to quantitatively characterize samples for electron density. We present how a precise measurement of electron density can be performed using an X-ray phase-contrast grating interferometer in a radiographic mode of a homogenous sample in a controlled geometry. A batch of various plastic materials was characterized quantitatively and compared with calculated results. We found that the measured electron densities closely match theoretical values. The technique yields comparable results between a monochromatic and a polychromatic X-ray source. Measured electron densities can be further used to design dedicated X-ray phase contrast phantoms and the additional information on small angle scattering should be taken into account in order to exclude unsuitable materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Origin of electrical signals for plasma etching end point detection: Comparison of end point signals and electron density

Electrical signals are used for end point detection in plasma etching, but the origin of the electrical changes observed at end point is not well understood. As an etch breaks through one layer and exposes an underlayer, the fluxes and densities of etch products and reactants in the gas phase will change. The resulting perturbation in gas composition may alter the plasma electron density, which in turn may affect the electrical signals. Alternatively, changes in substrate electrical properties or surface properties, such as work function or emitted electron yield, may be involved. To investigate these effects, experiments were performed in a radio-frequency (rf)-biased, inductively coupled reactor, during CF{sub 4}/Ar plasma etching of silicon dioxide films on silicon substrates. A complete set of electrical parameters, for the bias as well as the inductive source, was measured and compared. The most useful end point signal was found to be the fundamental rf bias impedance, which decreases when the oxide is removed. A simultaneous increase in plasma electron density was measured by a wave cutoff probe. Analytical sheath models indicate that the measured change in electron density accounts for nearly all of the impedance decrease. The change in electron density can in turn be explained by the effects of etch products or reactants on gas composition. In contrast, electrons emitted from the wafer surface play at most a minor role in the changes in electron density and impedance observed at end point.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Feedback control of plasma electron density and ion energy in an inductively coupled plasma etcher

Here the authors report the development of a fuzzy logic based feedback control of the plasma electron density and ion energy for high density plasma etch process. The plasma electron density was measured using their recently developed transmission line microstrip microwave interferometer mounted on the chamber wall, and the rf voltage was measured by a commercial impedance meter connected to the wafer stage. The actuators were two 13.56 MHz rf power generators which provided the inductively coupled plasma power and bias power, respectively. The control system adopted the fuzzy logic control algorithm to reduce frequent actuator action resulting from measurement noise. The experimental results show that the first wafer effect can be eliminated using closed-loop control for both poly-Si and HfO{sub 2} etching. In particular, for the HfO2 etch, the controlled variables in this work were much more effective than the previous one where ion current was controlled, instead of the electron density. However, the pressure disturbance effect cannot be reduced using plasma electron density feedback.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of frequency and pulse width on electron density, hydrogen peroxide generation, and perfluorooctanoic acid mineralization in a nanosecond pulsed discharge gas-liquid plasma reactor

Plasma electron density and temperature were characterized in a continuous flowing gas-liquid film reactor with argon carrier gas by time-resolved optical emission spectroscopy. The plasma parameters were studied as a function of time for varying pulse widths and frequencies. Pulse frequency was varied between 1 and 10 kHz at 16 kV (input voltage) and 40 ns (pulse width) using an Eagle Harbor Technologies, Inc. (EHT) power supply and 5–100 kHz using an Airity Technologies, LLC (AT) power supply. The pulse width was varied between 40 and 200 ns at 16 kV, 2 kHz with the EHT power supply. Optimal frequencies of 5 and 20 kHz were observed for peak electron density with EHT and AT power supplies, respectively. The peak electron density increased with increasing pulse width between 40 and 200 ns using the EHT power supply. Hydrogen peroxide exiting the reactor in the liquid phase increased with discharge power irrespective of the power supply or pulse parameters. Mineralization of 12.5, 50, and 200 ppm perfluorooctanoic acid (PFOA) dissolved in DI water to fluoride (F - ) correlated to the peak electron density. Glycerol, a liquid-phase hydroxyl radical scavenger, depleted hydrogen peroxide but did not affect PFOA mineralization. CO, a gas-phase hydroxyl radical scavenger, led to a reduction in the formation of F - production, suggesting hydroxyl radicals in the gas-liquid film play a necessary, but not singular, role in mineralization of PFOA.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Universal Solvation Model Based on Solute Electron Density and on a Continuum Model of the Solvent Defined by the Bulk Dielectric Constant and Atomic Surface Tensions

We present a new continuum solvation model based on the quantum mechanical charge density of a solute molecule interacting with a continuum description of the solvent. The model is called SMD, where the “D” stands for “density” to denote that the full solute electron density is used without defining partial atomic charges. “Continuum” denotes that the solvent is not represented explicitly but rather as a dielectric medium with surface tension at the solute-solvent boundary. SMD is a universal solvation model, where “universal” denotes its applicability to any charged or uncharged solute in any solvent or liquid medium for which a few key descriptors are known (in particular, dielectric constant, refractive index, bulk surface tension, and acidity and basicity parameters). The model separates the observable solvation free energy into two main components. The first component is the bulk electrostatic contribution arising from a self-consistent reaction field treatment that involves the solution of the nonhomogeneous Poisson equation for electrostatics in terms of the integral-equation-formalism polarizable continuum model (IEF-PCM). The cavities for the bulk electrostatic calculation are defined by superpositions of nuclear-centered spheres. The second component is called the cavity-dispersion-solvent-structure term and is the contribution arising from short-range interactions between the solute and solvent molecules in the first solvation shell. This contribution is a sum of terms that are proportional (with geometry-dependent proportionality constants called atomic surface tensions) to the solvent-accessible surface areas of the individual atoms of the solute. The SMD model has been parametrized with a training set of 2821 solvation data including 112 aqueous ionic solvation free energies, 220 solvation free energies for 166 ions in acetonitrile, methanol, and dimethyl sulfoxide, 2346 solvation free energies for 318 neutral solutes in 91 solvents (90 nonaqueous organic solvents and water), and 143 transfer free energies for 93 neutral solutes between water and 15 organic solvents. The elements present in the solutes are H, C, N, O, F, Si, P, S, Cl, and Br. The SMD model employs a single set of parameters (intrinsic atomic Coulomb radii and atomic surface tension coefficients) optimized over six electronic structure methods: M05-2X/MIDI!6D, M05-2X/6-31G*, M05-2X/6-31+G**, M05-2X/cc-pVTZ, B3LYP/6-31G*, and HF/6-31G*. Although the SMD model has been parametrized using the IEF-PCM protocol for bulk electrostatics, it may also be employed with other algorithms for solving the nonhomogeneous Poisson equation for continuum solvation calculations in which the solute is represented by its electron density in real space. This includes, for example, the conductor-like screening algorithm. With the 6-31G* basis set, the SMD model achieves mean unsigned errors of 0.6-1.0 kcal/mol in the solvation free energies of tested neutrals and mean unsigned errors of 4 kcal/mol on average for ions with either Gaussian03 or GAMESS.

36 MATERIALS SCIENCE↗

Parametric dependence of ion temperature and electron density in the SUMMA hot-ion plasma using laser light scattering and emission spectroscopy

Hot-ion plasma experiments were conducted in the NASA Lewis SUMMA facility. A steady-state modified Penning discharge was formed by applying a radially inward dc electric field of several kilovolts near the magnetic mirror maxima. Results are reported for a hydrogen plasma covering a wide range in midplane magnetic flux densities from 0.5 to 3.37 T. Input power greater than 45 kW was obtained with water-cooled cathodes. Steady-state plasmas with ion kinetic temperatures from 18 to 830 eV were produced and measured spectroscopically. These ion temperatures were correlated with current, voltage, and magnetic flux density as the independent variables. Electron density measurements were made using an unusually sensitive Thomson scattering apparatus. The measured electron densities range from 2.1 x 10 to the 11th to 6.8 x 10 to the 12th per cu cm.

Snyder, A.↗

Investigation of the Electron Density Variation During the 21 August 2017 Solar Eclipse

Abstract This paper presents a comparison of modeled and measured electron densities for the 21 August 2017 solar eclipse across the USA. The location of the instrument was (43.81°N, 247.32°E) where the maximum obscuration of 99.6% occurred at 17.53 hr UT on 21 August. The solar apparent time was 9.96 hr, and the duration of the eclipse was 2.7 hr. It was found that if it is assumed that there are no chromosphere emissions at totality, ~30% coronal emission remaining at totality gave the best fit to the electron density variation at 150 km. The 30% coronal emission estimate has uncertainties associated with respect to uncertainties in the solar spectrum, the measured electron density, and the amount of chromosphere emissions remaining at totality. The agreement between the modeled and measured electron densities is excellent at 150 km with the assumed 30% coronal emission at totality. At other altitudes, the agreement is very good, but the altitude profile would be improved if the model peak electron density ( N m F 2 ) decayed more slowly to better match the data. The minimum N m F 2 in the model occurs ~10 min after totality when it decreases to 0.55 from its noneclipse value. The minimum of the N m F 2 data occurs between 6 and 10 min after totality but is ~15% larger. The total electron content decreases to 0.65 of its preeclipse value. These relative changes agree well with those predicted by others prior to the eclipse.

Reinisch, B. W.↗

Power dependence of electron density at various pressures in inductively coupled plasmas

Experimental observation of the electron density variation in inductively coupled plasmas with the electron energy probability function (EEPFs) was performed at various gas pressures at two RF powers (25 W and 200 W). The measured EEPFs at high power discharges (200 W) showed a Maxwellian distribution, while evolution of the EEPFs from a bi-Maxwellian distribution to a Druyvesteyn-like distribution was observed at low RF powers (25 W) with increasing pressure. A discrepancy of the electron density variation between the two RF powers was observed. This difference is explained by the modified collisional loss and the Bohm velocity from the EEPF of the bi-Maxwellian distribution and the Druyvesteyn–like distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determination of Jupiter's electron density profile from plasma wave observations

The electron density measurements obtained in the Jovian magnetosphere from the plasma wave instruments on the Voyager 1 and 2 spacecraft are summarized. Three basic techniques for determining the electron density are discussed. They are (1) local measurements from the low-frequency cutoff of continuum radiation, (2) local measurements from the frequency of upper hybrid resonance emissions, and (3) integral measurements from the dispersion of whistlers. The limitations and advantages of each technique are reviewed.

Gurnett, D. A.↗

Measurements of electron density and temperature in the H-1 heliac plasma by helium line intensity ratios

Electron density and temperature distributions in the H-1 heliac plasma are measured using the helium line intensity ratio technique based on a collisional-radiative model. An inversion approach with minimum Fisher regularization is developed to reconstruct the ratios of the local emission radiances from detected line-integrated intensities. The electron density and temperature inferred from the He I 667.8/728.1 and He I 728.1/706.5 nm line ratios are in good agreement with those from other diagnostic techniques in the inner region of the plasma. The electron density and temperature values appear to be a little high in the outer region of the plasma. Some possible causes of the discrepancy in the outer region are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The derivation of temperature gradient and electron density maps from EUV spectroheliograms.

We discuss spatial variations in electron density at the base of the corona and in the temperature gradient in the chromospheric-coronal transition layer as determined from analysis of maps constructed from Mg X and O VI spectroheliograms. Both the mapping techniques and results of analyzing EUV spectra from OSO 6 observations are presented. Comparisons of these maps with photospheric magnetograms and spectroheliograms made in chromospheric EUV lines and continua indicate that the electron density and temperature gradient in the transition layer tend to be enhanced in areas where the photospheric magnetic field and chromospheric EUV emission are enhanced. Relationships among the coronal electron density, transition-layer temperature gradient, chromospheric emission, and photospheric magnetic field strength are derived.

Withbroe, G. L.↗

Electron Effective Mass and Momentum Relaxation Time in One-Sided δ-Doped PHEMT AlGaAs/InGaAs/GaAs Quantum Wells with High Electron Density

Using the Shubnikov–de Haas effect, the dependences of electron effective mass m* and transport and quantum momentum relaxation times in Al{sub 0.25}Ga{sub 0.75}As/In{sub 0.2}Ga{sub 0.8}As/GaAs pseudomorphic quantum wells with one-sided silicon δ-doping on the electron density in the range of (1.1–2.6) × 1012 cm{sup –2} have been established. Nonparabolicity coefficient m* in the linear approximation was found to be 0.133m{sub 0}/eV. Both the transport and quantum momentum relaxation times depend nonmonotonically on Hall electron density nH, which is related to the competition between growth mechanisms of the Fermi momentum and the increasing contribution of large-angle scattering with increasing donor concentration.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The allowed lines of O IV near 1340 A in high electron density solar flares

Intersystem lines of O IV near 1400 A have long been used as electron density diagnostics for solar plasmas at temperatures of around 160,000 K. In addition, however, several allowed lines of O IV near 1340 A should become visible in conditions of high plasma electron number density (greater than 10(exp 12)/cu cm), such as during a solar flare. We present observations of the 1340 A and 1400 A regions of the solar spectrum for two solar flares, obtained by the SO82B spectrograph on board Skylab. We examine three candidate lines for allowed O IV in the flare spectra which occur at the correct wavelengths, but show that two of these are actually blends dominated by resonantly excited molecular lines of H2. The third candidate line, at 1343.51 A, we identify as the O IV allowd line. We present the density and temperature sensitivity of the ratio of allowed and intersystem O IV lines R = I(1343.51 A)/I(1407.39 A). The 1343.51 A line is clearly present in the first solar flare spectrum, and the ratio value implies an electron density of log N(sub e) = 12.6. The second flare has a much weaker 1343.51 A profile, but again the ratio value implies a high electron density. Both these electron density values are in good agreement with estimates for each flare from independent diagnostic ratios. The simple presence alone of a clearly observed O IV 1343.51 A emission line implies an electron density greater than 10(exp 12)/cu cm.

Cook, J. W.↗

Absolute electron density measurements in the equatorial ionosphere

Accurate measurement of the electron density profile and its variations is crucial to further progress in understanding the physics of the disturbed equatorial ionosphere. To accomplish this, a plasma frequency probe was included in the payload complement of two rockets flown during the Condor rocket campaign conducted from Peru in March 1983. This paper presents density profiles of the disturbed equatorial ionosphere from a night-time flight in which spread-F conditions were present and from a day-time flight during strong electrojet conditions. Results from both flights are in excellent agreement with simultaneous radar data in that the regions of highly disturbed plasma coincide with the radar signatures. The spread-F rocket penetrated a topside depletion during both the upleg and downleg. The electrojet measurements showed a profile peaking at 1.3 x 10 to the 5th per cu cm at 106 km, with large scale fluctuations having amplitudes of roughly 10 percent seen only in the upward gradient in electron density. This is in agreement with plasma instability theory. It is further shown that simultaneous measurements by fixed-bias Langmuir probes, when normalized at a single point to the altitude profile of electron density, are inadequate to correctly parameterize the observed enhancements and depletions.

Baker, K. D.↗

Electron Densities Near Io from Galileo Plasma Wave Observations

This paper presents an overview of electron densities obtained near Io from the Galileo plasma wave instrument during the first four flybys of Io. These flybys were Io, which was a downstream wake pass that occurred on December 7, 1995; I24, which was an upstream pass that occurred on October 11, 1999; I25, which was a south polar pass that occurred on November 26, 1999; and I27, which was an upstream pass that occurred on February 22, 2000. Two methods were used to measure the electron density. The first was based on the frequency of upper hybrid resonance emissions, and the second was based on the low-frequency cutoff of electromagnetic radiation at the electron plasma frequency. For three of the flybys, Io, I25, and I27, large density enhancements were observed near the closest approach to Io. The peak electron densities ranged from 2.1 to 6.8 x 10(exp 4) per cubic centimeters. These densities are consistent with previous radio occultation measurements of Io's ionosphere. No density enhancement was observed during the I24 flyby, most likely because the spacecraft trajectory passed too far upstream to penetrate Io's ionosphere. During two of the flybys, I25 and I27, abrupt step-like changes were observed at the outer boundaries of the region of enhanced electron density. Comparisons with magnetic field models and energetic particle measurements show that the abrupt density steps occur as the spacecraft penetrated the boundary of the Io flux tube, with the region of high plasma density on the inside of the flux tube. Most likely the enhanced electron density within the Io flux tube is associated with magnetic field lines that are frozen to Io by the high conductivity of Io's atmosphere, thereby enhancing the escape of plasma along the magnetic field lines that pass through Io's ionosphere.

Gurnett, D. A.↗

Total electron content and F-region electron density distribution near the magnetic equator in India

Total electron content derived from the group delay measurements of ATS-6 radio beacons received at Ootacamund (India) are compared with the electron-density vs height distributions derived from the ionosonde data of the nearby station Kodaikanal. The daily variation of equivalent vertical total electron content does not show the midday bite out which is so prominently present in the corresponding daily variation of the maximum F-region electron density. The topside electron content continues to increase from sunrise to a maximum value around 1500 LT, while the bottomside electron content reaches a maximum value around 0500 LT. Daily variations of these as well as other parameters, e.g. the vertical slab thickness, the bottomside semi-thickness, the height of the F2 peak have been also studied for a geomagnetically quiet and a disturbed day.

Rastogi, R. G.↗