Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical test and measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

High Power Demonstration of a 100 kW Nested Hall Thruster System

The XR-100 team successfully completed high power system testing of a Nested Hall Thruster system made up of the X3 Nested Hall Thruster, a modular Power Processing Unit, and a 5 valve Mass Flow Controller as the culmination of work performed under a NASA NextSTEP program. The test campaign attained several key firsts, including highest directly measured thrust of an electric propulsion (EP) string, highest demonstrated current of an EP string, and highest power operation of an EP string at thermal equilibrium published to date. Most importantly, the XR-100 system testing demonstrated that a 100 kW-class Nested Hall Thruster system has comparable performance and behavior to current state-of-the-art mid power Hall Thrusters, validating that the heritage technology can be scaled up to 100+ kW

Shark, Sarah↗

Material Development of Faraday Cup Grids for the Solar Probe Plus Mission

The Solar Probe Plus mission will launch a spacecraft to the Sun to study it's outer atmosphere. One of the instruments on board will be a Faraday Cup (FC) sensor. The FC will determine solar wind properties by measuring the current produced by ions striking a metal collector plate. It will be directly exposed to the Sun and will be subject to the temperature and radiation environment that exist within 10 solar radii. Conducting grids within the FC are biased up to 10 kV and are used to selectively transmit particles based on their energy to charge ratio. We report on the development of SiC grids. Tests were done on nitrogen-doped SiC starting disks obtained from several vendors, including annealing under vacuum at 1400 C and measurement of their electrical properties. SiC grids were manufactured using a photolithographic and plasma-etching process. The grids were incorporated into a prototype FC and tested in a simulated solar wind chamber. The energy cutoffs were measured for both proton and electron fluxes and met the anticipated sensor requirements.

Volz, M. P.↗

Monolithic silicon bolometers

A new type of bolometer detector for the millimeter and submillimeter spectral range is described. The bolometer is constructed of silicon using integrated circuit fabrication techniques. Ion implantation is used to give controlled resistance vs temperature properties as well as extremely low 1/f noise contacts. The devices have been tested between 4.2 and 0.3 K. The best electrical NEP measured is 4 x 10 to the -16th W/Hz to the 1/2 at 0.35 K between 1- and 10-Hz modulation frequency. This device had a detecting area of 0.25 sq cm and a time constant of 20 msec at a bath temperature of 0.35 K.

Downey, P. M.↗

Comprehensive Performance Calibration Guidance for Perovskites and Other Emerging Solar Cells

Emerging photovoltaic (PV) technologies (e.g., organic, perovskite, and solution processed quantum dot) have attracted remarkable attention with the rapid growth of their efficiencies, and their transition toward commercialization. Accurate and reliable efficiency measurements of these PV technologies are crucial, yet much more complicated than for conventional PV technologies due to the former's pronounced dynamic responses to changes in measurement conditions (e.g., current–voltage (I–V) scan rate and preconditioning) and their susceptibility to degradation. Adjustments to the measurement procedures are therefore necessary so that a reproducible “steady state” is reached during measurement. Furthermore, given the small size of many emerging cells, inappropriate device area definition and solar simulator setup can lead to measurement errors. Here, comprehensive efficiency calibration guidance is offered for emerging solar cells, including area measurement; spectral irradiance translation to standard test conditions; and steady-state electrical performance. The necessity of reporting steady-state efficiency is justified with a statistical performance comparison between conventional and steady-state I–V scans over hundreds of cells the group has received globally for efficiency certifications. The procedures described here do not require specialized measurement instrumentation; what matters most are changes to the measurement protocols. These described changes aim to enable better comparisons between reported efficiencies.

14 SOLAR ENERGY↗

Light funnel concentrator panel for solar power

The solar concentrator design concept provides a theoretical concentration efficiency of 96 percent with power-to-weight ratios as high as 50 W/kg. Further, it eliminates the need for fragile reflective coatings and is very tolerant to pointing inaccuracies. The concept differs from conventional reflective mirrors and lens design in that is uses the principle of total internal reflection in order to funnel incident sunlight into a concentrator photovoltaic cell. The feasibility of the light funnel concentrator concept was determined through a balanced approach of analysis, development, and fabrication of prototypes, and testing of components. A three-dimensional optical model of the light funnel concentrator and photovoltaic cell was developed in order to assess the ultimate performance of such systems. In addition, a thermal and structural analysis of a typical unit was made. Techniques of fabricating the light funnel cones, optically coupling them to GaAs concentrator cells, bonding the funnels to GaAs cells, making electrical interconnects, and bonding substrates was explored and a prototype light funnel concentrator unit was fabricated and tested. Testing of the system included measurements of optical concentrating efficiency, optical concentrator to cell coupling efficiency, and electrical efficiency.

Source record↗

Characterization of an electrically conductive proppant for fracture diagnostics

Fracture diagnosis with electromagnetic (EM) and electrical tools requires proppants with high electrical conductivity and mechanical strength. Lab measurements of the electrical and hydraulic conductivity of proppants are critical for selecting the best candidates. Such measurements greatly benefit simulations, field tests, and the ultimate application of such proppants in the field. To that end, a new lab protocol is developed for measuring the electrical and hydraulic conductivity of proppants. The lab setup, which mainly includes a resistivity core holder and a Hassler sleeve core holder, allows for simulation of realistic pressure and temperature conditions when making measurements. Petroleum coke (PC) is proposed as a candidate proppant because of its widespread availability and low cost. Lab measurements show that the effective electrical conductivity of pure PC in a model fracture is approximately 5000 S/m, under a closure stress greater than [Formula: see text] (4000 psi). When PC is mixed with sand, the effective electrical conductivity of the mixture decreases with an increasing weight percentage of sand. Although sand degrades the contact between PC particles, the electrical conductivity stays reasonably high (approximately 1700 S/m) when 50% sand is added. Hydraulic conductivity measurements show that when a fracture is propped with pure PC, the measured fracture conductivity is greater than [Formula: see text] ([Formula: see text]) (dimensionless fracture conductivity greater than 100 for a shale with [Formula: see text] or 100 nD permeability) under a confining pressure of [Formula: see text] (6000 psi). This means that a fracture propped with PC is infinitely conductive in a typical shale formation. When sand is added, the fracture’s hydraulic conductivity becomes even higher, which clearly shows PC’s ability of sustaining high stresses. The proposed protocol provides a robust and effective method that can be generalized for lab testing for other candidate proppants. The data presented clearly show that PC has the potential for field-scale applications in EM hydraulic fracture diagnostics.

Geochemistry & Geophysics↗

Physics of sub-micron cosmic dust particles

Laboratory tests with simulated micrometeoroids to measure the heat transfer coefficient are discussed. Equations for ablation path length for electrically accelerated micrometeoroids entering a gas target are developed which yield guidelines for the laboratory measurement of the heat transfer coefficient. Test results are presented for lanthanum hexaboride (LaB sub 6) microparticles in air, argon, and oxygen targets. The tests indicate the heat transfer coefficient has a value of approximately 0.9 at 30 km/sec, and that it increases to approximately unity at 50 km/sec and above. Test results extend to over 100 km/sec. Results are also given for two types of small particle detectors. A solid state capacitor type detector was tested from 0.61 km/sec to 50 km/sec. An impact ionization type detector was tested from 1.0 to 150 km/sec using LaB sub 6 microparticles.

Roy, N. L.↗

Performance of Microreactor Test Article with Embedded Sensors During Testing in The Single Primary Heat Extraction and Removal Emulator

The nuclear industry is pursuing microreactors that can be factory assembled and deployed to remote regions for reliable power generation. One class of microreactors uses a monolithic metal core block coupled to heat pipes that use passive heat flow, increasing the surface area for heat transfer without requiring active coolant flow through the reactor core. Additional experimental testing is required to understand the heat rejection limitations of heat pipes and thermal stresses in the monolithic core block due to significant temperature gradients. This report describes the initial characterization and testing of a stainless-steel test article that was fabricated with embedded sensors to measure heat pipe performance limits, as well as spatially distributed temperatures and strains during electrically heated thermal testing to simulate nuclear heating. The electrically heated testing was performed in the Single Primary Heat Extraction and Removal Emulator facility located at Idaho National Laboratory. The ultimate goals of this work are to (1) accurately monitor temperature and strain distributions that result from differential thermal expansion in the test articles and (2) quantify the heat rejection limits of heat pipes as a function of operating temperature and working fluid during steady-state and transient operations. Initial tests focused on the feasibility of using advanced fiber-optic sensors and other sensor technologies to improve the understanding of temperature and strain distributions within the electrically heated experiments. However, these sensing capabilities could benefit the broader microreactor community if the sensors could be used to monitor component and system health during nuclear operations to inform a limited number of microreactor operators, ultimately reducing operation and maintenance costs and moving toward semiautonomous operation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Aircraft measurements of electrified clouds at Kennedy Space Center. Part 1: 1988 flights

During the fall of 1988, a Schweizer 845 airplane equipped to measure electric field and other meteorological parameters flew over Kennedy Space Center in a program to study clouds defined in the existing launch retriction requirements. The special purpose test vehicle for atmospheric research (SPTVAR) was suitable for flights through thunderclouds and was instrumented to measure all three components of the ambient electric vector. The main goals of the project were: (1) to develop and demonstrate techniques for measuring the electric field aloft and locate regions of charge during flight; (2) to characterize the electrical conditions within and near clouds that are presently identified as a threat to space launch vehicles; and (3) to study the correlation between the electric field aloft and that at Kennedy Space Center's ground-based field mill network for a variety of electrified clouds.

Jones, J. J.↗

Resonant Alfven waves on auroral field lines

It is shown that resonant Alfven waves on dipole magnetic field geometry and plasma distributions suitable for auroral field lines can be conventiently treated in the theory of Mathieu functions. Resurgent interest in invoking large-scale Alfven waves to structure some elements of auroral electrodynamics calls for interpretation of measured perpendicular electric and magnetic disturbance fields in terms of Alfven waves. The ability to express the resonant eigenmodes in closed form in terms of Mathieu functions allows for convenient tests of the Alfven wave structuring hypothesis. Implications for current vector electric and magnetic disturbance measurements are discussed.

Chiu, Y. T.↗

Results and progress on the NASA Lewis H2-O2 MHD program

A rocket test facility at the NASA Lewis Research Center has been used to develop interelectrode insulating materials, measure heat losses, and determine the fluid dynamic and electrical properties of MHD ducts and the cesium-seeded H2-O2 working fluid. Test results show that flame sprayed ceramic coatings on combustion chamber and nozzle walls permit operation with hot walls, eliminating problems associated with seed condensation; however, the net heat transfer was unexpectedly increased over that of cold copper walls. Pressure disturbances associated with oblique pressure waves were measured in a rocket nozzle designed to achieve low weight rather than perfectly parallel flow at the exit. Electrical conductivity measurements were in good agreement with theory except at low combustion pressures and/or high seed/oxygen mass flow ratios. The discrepancy is thought to result from poor atomization of the seed, producing droplets which do not completely vaporize during their residence time.

Smith, J. M.↗

Open Water Blade Strain Measurements on a Vertical-Axis Tidal Turbine

Open-water testing of marine renewable energy devices represents a significant milestone and hurdle for research teams and companies that seek to reduce the levelized cost of energy to allow these devices to compete in the open electrical generation market. For open-water testing of tidal energy converters (TECs), accurate measurements of loading characteristics on the blades and other structural components correlated with power performance metrics can be invaluable to further refine design principles and models, allowing continued improvement and cost reductions of new turbine designs. This paper will describe the modifications and additions made to a TEC system to achieve time-correlated blade strain measurements during full turbine operation along with a discussion on the overall impacts the required modifications had on the unmodified turbine.

mechanical loads↗

Standard Practices for Usage of Inductive Magnetic Field Probes with Application to Electric Propulsion Testing

Inductive magnetic field probes (also known as B-dot probes and sometimes as B-probes or magnetic probes) are often employed to perform field measurements in electric propulsion applications where there are time-varying fields. Magnetic field probes provide the means to measure these magnetic fields and can even be used to measure the plasma current density indirectly through the application of Ampere's law. Measurements of this type can yield either global information related to a thruster and its performance or detailed, local data related to the specific physical processes occurring in the plasma. Results of the development of a standard for B-dot probe measurements are presented, condensing the available literature on the subject into an accessible set of rules, guidelines, and techniques to standardize the performance and presentation of future measurements.

Polzin, Kurt A.↗

Radiometric Testing of Germicidal UV Products, Round 2: Upper-Room Luminaires (CALiPER Report)

This report analyzes the independently tested performance of eight germicidal ultraviolet (GUV) upper-room luminaires marketed for use in occupied spaces and purchased between March and June 2023. Three of the luminaires used UV-emitting LEDs, and the remaining five luminaires used low-pressure mercury (LPM) lamps. Product testing covered radiometric and electrical performance for each luminaire. Initial performance was measured for all eight products, and four were additionally measured after 100 h and 500 h of operation. Measured performance was compared against manufacturer or vendor claims. Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. As with the CALiPER GUV Round 1 report, this CALiPER GUV Round 2 report demonstrates that manufacturers and vendors need significant education and training to accurately test and report the performance of their GUV products. Further development of industry consensus standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electromagnetic compatibility characterization of a BAe Stirling-cycle cryocooler for space application

This paper describes the electromagnetic compatibility (EMC) measurements of an 80-K Stirling-cycle cooler. The measurements, performed in the JPL EMC test facility, include dc magnetic field characterization, radiated magnetic and electric field emissions, and conducted emissions on the internal lines between the cooler electronics and the cooler. The measurements conform to both the MILSTD-461C specifications as well as to the specifications for the NASA Earth Observing System.

Johnson, Dean L.↗

Electrical isolation design and electrochemical corrosion in thin-film photovoltaic modules

The development of a proposed wet insulation-resistance qualification test specification for production-line modules is presented. Laboratory research directed toward understanding and eliminating problems associated with electrical isolation of thin-film photovoltaic module circuitry is presented. Test results serve to measure module field life as limited by electrochemical corrosion degradation mechanisms. Current module-level research covering encapsulant voltage withstand capability is also described, and suggestions for improving module electrical isolation are offered.

Sugimura, R. S.↗