Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical cables”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Power Cable Mass Estimation for Electric Aircraft Propulsion

Electric aircraft propulsion relies on power transmission cables to carry energy through the vehicle's electrical power train. The mass of these cables is an important consideration in overall aircraft weight, and hence cable design methods that can offer lower weight cables offer a significant opportunity.This paper compares three strategies for cable design: selection of cables from off-the-shelf options, design based on steady-state thermal limits, and design based on transient thermal limits. The thermal models consider both conductor diameter and insulation thickness, as well as a comparison between multiple conductor materials. The thermal analysis evaluates the transfer of waste heat from the conductor to the insulation and from the insulation to the air via convection. Optimizations to minimize cable mass by changing conductor radius and material properties were performed using all three modeling approaches and the results show that both custom sized cables using both steady-state and transient based model offer potential mass savings.

Electrical↗

Lightning-activated electrical ground for cable shields

Device protects cables used to connect circuits that are physically separated from lightning-induced high-voltage. Circuit returns to normal high impedance open configuration after lightning-induced shield voltage is dissipated.

Castle, K. D.↗

PNNL ARENA Cable Motor Test Bed Update

A major focus of the Light Water Reactor Sustainability (LWRS) Cable Nondestructive Examination (NDE) 2021 research is to acquire new equipment and integrate it with existing NDE instruments for a cable motor test bed which has been dubbed the Accelerated and Real Time Experimental Nodal Analysis or “ARENA”. All the primary components have been received and are being staged in the 2410 Stevens building on PNNL’s Richland campus. Building modifications to support a plug-in 480VAC receptacle have been completed and details of the system operating procedure (SOP) are in review. The approved SOP is required before the system is energized but is expected before July 2021. The ARENA system will support planned cable tests for 2021 and beyond that cannot conveniently be performed with on-site installations of cable test equipment including: (1) NDE Tests including Frequency Domain Reflectometry (FDR), Time Domain Reflectometry (TDR), Tan Delta (TD) Impedance measurements, Low Frequency Dielectric Spectroscopy (DS) measurements, standard multi-meter resistance checks, withstand tests and other bulk and distributed tests from the instrument panel with and without motors connected. (2) Online energized live wire tests using partial discharge instruments and LIVE-WIRE spread-spectrum TDR instruments. (3) Cable tests with partially submerged cable segments (including ability to submerge live cable segments). (4) Cable tests with partially or completely thermally aged segments (including ability to expose energized cable segments to thermal aging and use online monitoring instruments to monitor cable performance. (5) Ability to introduce low resistance simulations of connector or splice faults to off-line and on-line instrument setups.

42 ENGINEERING↗

Electronic packaging and cabling

Testing electrical, mechanical, and handling properties and environmental characteristics of small gage electrical wire for interplanetary spacecraft

Source record↗

Power transmission cable development for the Space Station Freedom electrical power system

Power transmission cable is presently being evaluated under a NASA Lewis Research Center advanced development contract for application in the Space Station Freedom (SSF) electrical power system (EPS). Evaluation testing has been performed by TRW and NASA Lewis Research Center. The results of this development contract are presented. The primary cable design goals are to provide (1) a low characteristic inductance to minimize line voltage drop at 20 kHz, (2) electromagnetic compatibility control of the 20-kHz ac power current, (3) a physical configuration that minimizes ac resistance and (4) release of trapped air for corona-free operation.

Schmitz, Gregory V.↗

Performance experiments with alternative advanced teleoperator control modes for a simulated solar maximum satellite repair

Experiments are described which were conducted at the JPL Advanced Teleoperator Lab to demonstrate and evaluate the effectiveness of various teleoperator control modes in the performance of a simulated Solar Max Satellite Repair (SMSR) task. THe SMSR was selected as a test because it is very rich in performance capability requirements and it actually has been performed by two EVA astronauts in the Space Shuttle Bay in 1984. The main subtasks are: thermal blanket removal; installation of a hinge attachment for electrical panel opening; opening of electrical panel; removal of electrical connectors; relining of cable bundles; replacement of electrical panel; securing parts and cables; re-mate electrical connectors; closing of electrical panel; and reinstating thermal blanket. The current performance experiments are limited to thermal blanket cutting, electrical panel unbolting and handling electrical bundles and connectors. In one formal experiment even different control modes were applied to the unbolting and reinsertion of electrical panel screws subtasks. The seven control modes are alternative combinations of manual position and rate control with force feedback and remote compliance referenced to force-torque sensor information. Force-torque sensor and end effector position data and task completion times were recorded for analysis and quantification of operator performance.

Das, H.↗

Improved Connector Shell for Cable Shields

Cable connector shell improves electrostatic and electromagnetic shielding by electrically connecting cable braid around entire circumference. Connector cable braid is slipped over ferrule and sleeve is slipped over braid, clamping it tightly to shell. Connector shell completely shields cable conductors.

Prisk, A. L.↗

Ensuring a Nuclear Power Plant Safe State Following an EMP Event - Task 7 Deliverable: EMP Testing of Secondary Coupling to Instrumentation Cables

Sandia National Laboratories performed tests to address the potential vulnerability concerns of a coupled High-Altitude Electromagnetic Pulse (HEMP) inducing secondary coupling onto critical instrumentation and control cables in a nuclear power plant, with specific focus on early-time HEMP. Three types of receiving cables in nine configurations were tested to determine transfer functions between two electrically separated cables referenced to the common mode input current on the transmitting cable. One type of transfer function related the input short circuit current and resulting open circuit voltage on the receiving cable. The other transfer function related the input short circuit current and the resulting short circuit current on the receiving cable. A 500 A standard HEMP waveform was input into the transfer functions to calculate peak coupling values on the receiving cables. The highest level of coupling using the standard waveform occurred when cables were in direct contact, with a peak short circuit current of 85 A and open circuit voltage of 9.8 kV, while configurations with separated cables predicted coupling levels of less than 5 A or 500 V.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Protected, high-temperature connecting cable

Ceramic insulated, swaged stainless steel, sheathed, protective atmosphere cable admits electrical leads into an 1800 deg F air-environment test chamber. The cable has some bending capability and provides for nine niobium alloy conductors. An argon purge during the TIG weld closure protects internal wires from oxidation and embrittlement.

Engdahl, R. E.↗

Electrically Small Microstrip Quarter-Wave Monopole Antennas

Microstrip-patch-style antennas that generate monopole radiation patterns similar to those of quarter-wave whip antennas can be designed to have dimensions smaller than those needed heretofore for this purpose, by taking advantage of a feed configuration different from the conventional one. The large sizes necessitated by the conventional feed configuration have, until now, made such antennas impractical for frequencies below about 800 MHz: for example, at 200 MHz, the conventional feed configuration necessitates a patch diameter of about 8 ft (.2.4 m) . too large, for example, for mounting on the roof of an automobile or on a small or medium-size aircraft. By making it possible to reduce diameters to between a tenth and a third of that necessitated by the conventional feed configuration, the modified configuration makes it possible to install such antennas in places where they could not previously be installed and thereby helps to realize the potential advantages (concealment and/or reduction of aerodynamic drag) of microstrip versus whip antennas. In both the conventional approach and the innovative approach, a microstrip-patch (or microstrip-patch-style) antenna for generating a monopole radiation pattern includes an electrically conductive patch or plate separated from an electrically conductive ground plane by a layer of electrically insulating material. In the conventional approach, the electrically insulating layer is typically a printed-circuit board about 1/16 in. (.1.6 mm) thick. Ordinarily, a coaxial cable from a transmitter, receiver, or transceiver is attached at the center on the ground-plane side, the shield of the cable being electrically connected to the ground plane. In the conventional approach, the coaxial cable is mated with a connector mounted on the ground plane. The center pin of this connector connects to the center of the coaxial cable and passes through a hole in the ground plane and a small hole in the insulating layer and then connects with the patch above one-third of the radial distance from the center. The modified feed configuration of the innovative approach is an inductive-short-circuit configuration that provides impedance matching and that has been used for many years on other antennas but not on microstrip-style monopole antennas. In this configuration, the pin is connected to both the conductive patch and the ground plane. As before, the shield of the coaxial cable is connected to the ground plane, but now the central conductor is connected to a point on the pin between the ground plane and the conductive plate (see figure). The location of the connection point on the pin is chosen so that together, the inductive short circuit and the conductive plate or patch act as components of a lumped-element resonant circuit that radiates efficiently at the resonance frequency and, at the resonance frequency, has an impedance that matches that of the coaxial cable. It should be noted that the innovative design entails two significant disadvantages. One disadvantage is that the frequency bandwidth for efficient operation is only about 1/20 to 1/15 that of a whip antenna designed for the same nominal frequency. The other disadvantage is that the estimated gain is between 3-1/2 and 4-1/2 dB below that of the whip antenna. However, if an affected radio-communication system used only a few adjacent frequency channels and the design of the components of the system other than the antenna provided adequate power or gain margin, then these disadvantages could be overcome.

Young, W. Robert↗

Effect of Mechanical Deformation on the Dielectric Electric Field in Dynamic Umbilical Cables

Wave energy converter (WEC) systems have unique umbilical cable design requirements compared to conventional marine designs. Due to their dynamic nature, WEC umbilical cables are required to handle increased loads and larger motions over longer deployment scenarios. However, the life expectancy of dynamic umbilical cables is predominantly analyzed for mechanical fatigue, with little consideration given to the effect of mechanical stress on the response of the dielectric as it has been previously assumed that the non-polymeric components will fail prior to the polymeric components. In this work, we explore the effects of mechanical bending on the concentration of the electric field in the insulation of a conceptual three-core dynamic umbilical cable to determine the limiting requirements for life expectancy. A conceptual industrial schematic of a medium voltage dynamic umbilical cable was used as the basis for the WEC system under study. Simulations on the dynamic umbilical cable were performed using COMSOL Multiphysics®. Mechanical loads up to the calculated limit (2.64 m minimum bend radius or 388 kN transverse load) were applied to the dynamic umbilical in a step-wise fashion with one end of the umbilical cable fixed. One-way coupling in three-dimensions was conducted by first determining the engineering strains, then using the engineering strains as the initial condition for determination of the Green-Lagrange strains, and lastly calculating the electric field in the deformed dielectric. Based upon the input load, deformation of the dielectric at the minimum bend radius produced an increase in the electric field of more than 12% when compared to the undeformed umbilical cable, which may lead to dielectric breakdown of the insulation prior to mechanical failure of the umbilical cable.

Spencer, Mychal P.↗

Hypervelocity impact testing of cables

The physics and electrical results obtained from simulated micrometeoroid testing of certain Skylab cables are presented. The test procedure, electrical circuits, test equipment, and cable types utilized are also explained.

Jex, D. W.↗

Magnetically Attached Multifunction Maintenance Rover

A versatile mobile telerobot, denoted the magnetically attached multifunction maintenance rover (MAGMER), has been proposed for use in the inspection and maintenance of the surfaces of ships, tanks containing petrochemicals, and other large ferromagnetic structures. As its name suggests, this robot would utilize magnetic attraction to adhere to a structure. As it moved along the surface of the structure, the MAGMER would perform tasks that could include close-up visual inspection by use of video cameras, various sensors, and/or removal of paint by water-jet blasting, laser heating, or induction heating. The water-jet nozzles would be mounted coaxially within compressed-air-powered venturi nozzles that would collect the paint debris dislodged by the jets. The MAGMER would be deployed, powered, and controlled from a truck, to which it would be connected by hoses for water, compressed air, and collection of debris and by cables for electric power and communication (see Figure 1). The operation of the MAGMER on a typical large structure would necessitate the use of long cables and hoses, which can be heavy. To reduce the load of the hoses and cables on the MAGMER and thereby ensure its ability to adhere to vertical and overhanging surfaces, the hoses and cables would be paid out through telescopic booms that would be parts of a MAGMER support system. The MAGMER would move by use of four motorized, steerable wheels, each of which would be mounted in an assembly that would include permanent magnets and four pole pieces (see Figure 2). The wheels would protrude from between the pole pieces by only about 3 mm, so that the gap between the pole pieces and the ferromagnetic surface would be just large enough to permit motion along the surface but not so large as to reduce the magnetic attraction excessively. In addition to the wheel assemblies, the MAGMER would include magnetic adherence enhancement fixtures, which would comprise arrays of permanent magnets and pole pieces that could be adjusted to maximize or minimize the overall attractive magnetic force. Even with a paint thickness of 2 mm, a preliminary design provides a safety factor of 5 in the magnetic force in the upside- down, water-jets-operating condition, in which the total load (including the weight of the MAGMER and cables and the water-jet force) would be about 260 lb (the weight of 118 kg). Optionally, the MAGMER could carry magnetic shielding and/or could be equipped with a demagnetizing module to remove residual magnetism from the structure. The MAGMER would carry four charge-coupled-device cameras for visual inspection, monitoring of operation, navigation, and avoidance of collisions with obstacles. The control system of the MAGMER would include navigation and collision-avoidance subsystems that would utilize surface features as landmarks, in addition to direct images of obstacles.

Bar-Cohen, Yoseph↗

Strength-conductivity synergy via lean alloy design: A study on novel solid stir extrusion of an Al-2Cu-0.1 Nb-0.15Zr (~wt.%) alloy

Aluminum alloys find wide applications in power and transmission cables, and electrical conductors due to their advantageous properties of high electrical conductivity, and lower cost per unit. However, the lower tensile strength compared to copper poses a challenge for the mechanical stability of aluminum-based cables. In this study, we addressed this issue by adopting a process-based alloy design approach, creating a lean alloy with a dilute composition of Al-2Cu-0.1 Nb-0.15Zr (~wt.%). Here, the alloy was processed using a friction stir based novel SolidStir® (SSE) technique, followed by low-temperature aging. The resulting aluminum wire exhibited improved strength (240 MPa) while simultaneously enhancing electrical conductivity (64%IACS). The study employed computational simulations (Thermocalc) and experimental techniques (differential scanning calorimetry and transmission electron microscopy) to thoroughly investigate the microstructure. Microstructural examinations revealed that the precipitation kinetics in SSE and SSE+aged conditions played a significant role in enhancing strength and electrical conductivity. These findings demonstrate the successful achievement of high strength and high electrical conductivity in aluminum wire through a lean alloy design approach.

36 MATERIALS SCIENCE↗