Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric power grid operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

VSC-HVDC Interties for Urban Power Grid Enhancement

Urban power grids are facing many operational and expansion challenges to meet further demand growth and increased reliability requirements. Advanced transmission technologies have been considered by the electric utilities to effectively increase the utilization of existing infrastructure and operational flexibility. The focus of this paper is on VSC-HVDC technologies for urban power grid enhancement and modernization. First, a potential technical scheme is proposed for converting an existing AC circuit to DC operation, which could boost the power transfer capability of the critical transmission corridor and increase network operational flexibility. Second, this paper proposes three operation modes for the VSC-HVDC interties in urban power grids corresponding to normal, emergency and island operating conditions, respectively. An integrated, adaptive emergency control strategy (AEC) is proposed that can enable adaptive power flow responses of the VSC-HVDC intertie under varying system operating conditions and critical contingencies. The flexibility and effectiveness of the proposed operational principles of urban VSC-HVDC intertie and the corresponding control strategies are verified in PSCAD/EMTDC using a realistic urban power grid in China.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Component level modeling of materials degradation for insights into operational flexibility of Existing Coal Power Plants

Increasingly, coal-fired power plants are required to balance power grids by compensating for the variable electricity supply from renewable energy sources. Fossil-fueled power plants, originally designed to be base loaded, will increasingly need to operate on a load following or cyclic basis. This demanding requirement for operational flexibility needs insights into accelerated material degradation arising due to the harsh operating conditions (e.g., fatigue, early oxide exfoliation due to stresses) along with current damage mechanisms (fireside corrosion, creep and erosion) observed in service. Our research objective is to develop component level modeling toolkit for materials-based degradation for two key mechanisms that can accelerate with cyclic operations. In more detail, this includes the fireside corrosion/steam oxidation/erosion/creep/fatigue of superheaters/reheaters and steam pipework and also the water droplet erosion/ fatigue of last stage steam turbine blades degradation mechanisms, that demand routine and sometimes unplanned maintenance and repair. The innovation is in developing a computational fluid dynamics/finite element (CFD/FE) modeling toolkit for the component level models of the boilers and low-pressure steam turbines in coal power plants that can tackle multidisciplinary failure mechanisms occurring concurrently for extreme environment materials. Lifetime assessment in such environments also needs to account for the unit-specific analyses, operational history and fuel feedstock; this can only be obtained by destructive analysis of components. This, in turn, enables validation of the model toolkits utilizing service feedback data, improving the probability of time/temperature dependent life prediction.

20 FOSSIL-FUELED POWER PLANTS↗

Environmental Validation of Materials and Design Concepts to Enable Operational Flexibility of Existing Coal Power Plants

Increasingly, coal-fired power plants are required to balance power grids by compensating for the variable electricity supply from renewable energy sources. Fossil-fueled power plants, originally designed to be base loaded, will increasingly need to operate on a load following or cyclic basis. This demanding requirement for operational flexibility will need to be evaluated for resilience to frequent start-ups, meeting major and rapid load changes, and providing frequency control duties. Our research objective was to evaluate and improve flexibility of existing power plants by improving and redesigning components and defining new operational strategies, with acceptable impacts on component life, efficiency and emissions.

20 FOSSIL-FUELED POWER PLANTS↗

New Tool Evaluates the Financial Viability of Pumped Storage Hydropower

The rapidly evolving electricity system with increasing variable renewable energy (VRE) resources provides both opportunities and challenges for the power sector. With the significant ramps and intermittency associated with VRE resources, the requirements and need for additional flexible resources increase. Pumped storage hydropower (PSH) provides flexibility to the electricity grid to replace fossil fuel plants, which are responsible for 25% of U.S. emissions. PSH projects support various aspects of power system operations, including flexibility, ramping capability, energy, ancillary service, black start, and others. The significant potential of hydropower requires understanding the different value drivers to the electricity system specific to the location of a project and then optimizing the plant for the different system values. Thus, determining the value of PSH projects and their many services and contributions to the electricity system can be a challenge for potential developers, system owners, regulators, policy makers, and consultants.

13 HYDRO ENERGY↗

Power System Event Classification and Localization Using a Convolutional Neural Network

Detection and timely identification of power system disturbances are essential for situation awareness and reliable electricity grid operation. Because records of actual events in the system are limited, ensemble simulation-based events are needed to provide adequate data for building event-detection models through deep learning; e.g., a convolutional neural network (CNN). An ensemble numerical simulation-based training data set have been generated through dynamic simulations performed on the Polish system with various types of faults in different locations. Such data augmentation is proven to be able to provide adequate data for deep learning. The synchronous generators’ frequency signals are used and encoded into images for developing and evaluating CNN models for classification of fault types and locations. With a time-domain stacked image set as the benchmark, two different time-series encoding approaches, i.e., wavelet decomposition-based frequency-domain stacking and polar coordinate system-based Gramian Angular Field (GAF) stacking, are also adopted to evaluate and compare the CNN model performance and applicability. The various encoding approaches are suitable for different fault types and spatial zonation. With optimized settings of the developed CNN models, the classification and localization accuracies can go beyond 84 and 91%, respectively.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Accelerating Transitions to Zero Carbon Power Systems

As power systems evolve, becoming increasingly renewable, distributed, dynamic, and digital, managing them becomes ever more challenging and complex. System operators serve as the "air traffic controllers" for electricity grids, working to balance supply and demand, manage evolving electricity markets, and ensure the safety and reliability of electricity systems. To adapt to the rapidly changing energy landscape and support the transition to modern, zero carbon power systems, system operators must develop and adopt new technologies, approaches, and frameworks. The Global Power System Transformation (G-PST) Consortium is a network of system operators, research institutions, and industry partners working to accelerate and scale the technical solutions required to transform our world's power systems. By developing and sharing robust models and tools, research and demonstration results, knowledge, and innovation, the G-PST Consortium is empowering system operators to transition to 100% renewable energy while ensuring the reliability, safety, and cost-effectiveness of grid operations.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

Developing a Disaster-Ready Power Grid Agent Through Geophysically-Informed Fault Event Scenarios

Management of the nation’s power grid over the coming decades will need to factor multiple climate-driven threats to the power system that can be stressful or even detrimental to its operations. During disasters, grid operators suffer from cognitive overload where the electric grid is severely impacted by the weather, yet grid operators have limited awareness of these factors. Meanwhile, the electric grid is facing an explosion of data coming from a variety of sources which can enable the operator to evaluate the risks and develop mitigation strategies against hazardous events. In this work, we processed heterogeneous environmental and power grid data to learn and model grid behavior caused by extreme weather events. In this study, we focused on two weather-driven hazards, hurricanes and wildfires, which were analysed for the electric grid of Texas. We the used this data to train a Reinforcement Learning (RL) agent by analysing and predicting future behaviour of the grid during those hazard events. All these parts are incorporated in one framework to have a geophysically informed power simulators that can be used to train RL agents.

electic grid, reinforcement learning, climate adap↗

Transmission Operator Workflows for Real-Time Reliability Studies: A Review of Control Room Practices and Naturalistic Decision Making

This report provides an overview of real-time reliability study tools and their use by power system operators in the control room environment. After introducing some of the nuances of the control room environment and the differences in perspectives between power system engineers and operators, the roles and responsibilities of key entities involved in RTCA workflows are introduced. These are specifically the transmission system operator (TOP) and reliability coordinator (RC), which are required to run tools such as real-time contingency analysis (RTCA) as part of a real-time reliability assessment every 30 minutes, as dictated by a series of standards issued by the North American Electric Reliability Corporation (NERC). The process by which power systems operators operate the grid is discussed in terms of naturalistic decision making (NDM) and the recognition-primed decision-making (RPD) model. This cognitive model describe how experts working in high-risk, high-stress environments make safety-critical decisions under uncertainty and time pressure. For power system operators, the mental simulations involved in the traditional RPD model are supplemented by physics-based simulations using numerical tools, such as RTCA, to improve situational awareness and effectiveness of control actions. Next, a generic workflow is introduced to describe operator decision making for running RTCA tools and responding to system violations on a pre-contingent basis. The types of analysis performed and control actions chosen by power system operators are described in detail. The overall high-level workflow is then expanded in subsequent sections, with special attention given to high-voltage violations, low-voltage violations, and thermal overloads. Each type of violation is described in detail, with explanations of common causes, impacts on equipment and customers, and mitigation strategies. An additional workflow diagram is provided for each type of violation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An ERCOT test system for market design studies

An open source test system is developed that permits the dynamic modeling of centrally-managed wholesale power markets operating over highvoltage transmission grids. In default mode, the test system models basic operations in the Electric Reliability Council of Texas (ERCOT): namely, centrally-managed day-ahead and real-time markets operating over successive days, with congestion handled by locational marginal pricing. These basic operational features characterize all seven U.S. energy regions organized as centrally-managed wholesale power markets. Modeled participants include dispatchable generators, load-serving entities, and non-dispatchable generation such as unrmed wind and solar power. Users can congure a broad variety of parameters to study basic market and grid features under alternative system conditions. Users can also easily extend the test system's Java/Python software classes to study modied or newly envisioned market and grid features. Finally, the test system is integrated with a high-level simulation framework that permits it to function as a software component within larger systems, such as multi-country systems or integrated transmission and distribution systems. Finally, detailed test cases with 8-bus and 200-bus transmission grids are reported to illustrate these test system capabilities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Welcome to the Special Issue on Grid-Edge Computing With Behind-the-Meter Resources [Guest Editorial]

The integration of distributed energy resources (DERs), such as solar photovoltaic systems, as well as other synergistic assets, including electric vehicles, energy storage, and smart appliances, in electric power systems has been dramatically increasing in the past few years. These assets have the capability to provide much-needed flexibility to electric power systems for improved grid reliability, resilience, and economic efficiency; however, most of these resources are located behind the meter (BTM) on customer premises, and their flexibility is not fully used in current grid operations. Grid-edge computing plays an important role in unlocking the great benefits and potential that BTM resources could provide to electric power systems by enhancing visibility and controllability at the grid edge.

behind-the-meter resources↗

Quantifying the Protectability of Power Systems for Restoration Applications

With the increasing availability of distributed energy resources, controllable switches, and advanced metering infrastructure, distribution systems are exploring opportunities for improving system reliability through fault location, isolation, and service restoration. During permanent outages, this requires islanding microgrids and/or reconfiguration of the feeders; however, it is critical to assess the protection of the islanded/reconfigured networks before transition because the rated load and fault current conditions change. This paper presents a novel “protectability” metric that quantifies the protection performance and allows the operators to compare the effectiveness of the protection between two or more possible reconfiguration and islanding approaches. We present the mathematical formulation and assumptions for the metric. Multiple configurations of the Electric Power Research Institute J1 feeder, both in grid-connected and weak-sourced islanded operation, are used to demonstrate the performance of the metric with reference to overcurrent protection. Takeaways for future studies on system planning integration are provided.

distributed energy resources↗

A Decision Support Framework for Grid-Aware Electric Bus Charge Scheduling

While there are many advantages to electric public transit vehicles, they also pose new challenges for fleet operators. One key challenge is defining a charge scheduling policy that minimizes operating costs and power grid disruptions while maintaining schedule adherence. An uncoordinated policy could result in some buses running out of charge before completing their trip, while a grid agnostic policy might incur higher energy costs or cause an adverse impact on the grid’s distribution system. We present a grid aware decision-theoretic framework for electric bus charge scheduling that accounts for energy price, grid load, and bus status. The framework connects environmental models for traffic (SUMO) and the electric grid (GridLAB-D) to a planner, which evaluates bus charging decisions with regard to their long-term effect on grid reliability and cost. The framework has been evaluated on a simulation of Richland, WA’s bus and grid network, and compared to greedy methods.

EV, machine leaning, EV-Grid, Transportation, Grid↗

Electrification Futures Study: Power Systems Operation with Newly Electrified and Flexible Loads

The Electrification Futures Study (EFS) is a multi-year study designed to analyze the impacts of widespread electrification in the U.S. energy system. In this webinar we present the detailed power systems operational analysis from the final report in the EFS series. For this analysis, we simulate multiple 2050 power systems for the conterminous United States to assess how variations in the magnitude and shape of electricity demand driven by electrification, and the extent of load participation to more-actively provide grid services, might impact the hourly operation, operational costs, and emissions of various power systems in 2050. The impacts of electrification and demand flexibility are overlayed across systems with significantly greater penetrations of variable renewable energy than today. Overall, we find that the high electrification scenarios envisioned in the EFS with significant VRE penetration (66% of annual national generation) can be operated to meet future increased levels of electrified demand. We also find that demand-side flexibility can enhance operational efficiency and reduce overall annual production costs by $5-$10 billion. The complementary relationship between flexible electric vehicle charging loads and solar generation is particularly pronounced, but in the absence of demand-side flexibility electrification can lead to increased wind and solar curtailment. By helping to reduce renewable curtailment, flexibility can also reduce power sector CO2 emissions. The analysis highlights the value of increased integration and coordination of demand- and supply-side resources in future electric system planning and operations—particularly under high electrification futures.

43 PARTICLE ACCELERATORS↗

Explained: Fundamentals of Power Grid Reliability and Clean Electricity

Maintaining reliability of the bulk power system, which supplies and transmits electricity, is a critical priority for electric grid planners, operators, and regulators. As we move toward a cleaner electricity system with more technologies like wind, solar, and battery storage, the way in which we plan for and achieve reliability will change. This fact sheet provides additional technical background to the topics covered in three other reliability explainers on how we measure, enforce, and plan for reliable systems with more clean electricity.

POWER TRANSMISSION AND DISTRIBUTION↗

An empirical study of moving horizon closed-loop demand response scheduling

The potential of electricity-intensive chemical plants to engage in demand response (DR) initiatives in support of power grid operations has been the subject of many conceptual studies. In this work, using an industrially-relevant model of an air separation unit, we undertake an extensive simulation study of moving horizon (MH) rescheduling approaches, where we "close the scheduling loop" based on updated information regarding disturbances such as changes in electricity prices, ambient conditions and chemical product demand. Our study produces several unexpected findings regarding the non-periodic nature of rescheduling solutions, the impact of the accuracy of disturbance forecasts on the economics of DR scheduling, and on the interplay of simultaneously dealing with fluctuations on both the supply side (i.e., electricity prices) and the product demand side of the plant. Furthermore, we posit that the latter fluctuations pose significant limitations to the potential of a chemical plant to engage in DR.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Oak Ridge National Laboratory Pilot Demonstration of an Attestation and Anomaly Detection Framework using Distributed Ledger Technology for Power Grid Infrastructure

This report summarizes the design and pilot demonstration of a framework called Grid Guard that was created to provide increased data and device trustworthiness to electric grid devices by leveraging distributed ledger technology (DLT), specifically blockchain. Grid Guard contains a combination of core cryptographic methods such as the secure hash algorithm (SHA), and asymmetric cryptography, private permissioned blockchain, baselining configuration data, consensus algorithm (Raft) and the Hyperledger Fabric (HLF) framework. The system implements a low energy, fast, and robust enhancement to system trustworthiness within and across electric grid systems such as substations, control centers and metering infrastructures. Blockchain is a distributed database structured that provides a practically unalterable (immutable) timeline of stored transactions. By relying on hashing and the Raft consensus algorithm, if an entity tries to illegitimately alter a record at one instance of the database the other ledger nodes are not altered. They work to cross-reference each other and easily locate any incorrectly added data and remove it. The bulk raw data is stored in an off-chain storage (outside of the blockchain ledger) and a hash of this baseline data is stored in the Blockchain ledger via hashing windows of time-series and configuration data, after aggregation and filtering. The bulk off-chain data repository is then considered to be trust-anchored using the hashes stored in the blockchain. To secure the electric grid testbed devices and data, device configuration baselines were compared to those baselines that had been previously stored in the ledger. Statistical baselines for device configurations, network communication patterns, and high-speed sensor data are calculated and then stored off-chain and hashes stored in the ledger. Measurements such as three-phase voltage and current, frequency, breaker status, protection scheme settings, network configuration settings (and other device configuration artifacts) and network traffic features (packet interarrival times) are compared every minute or other selected time windows. During phase 1 of the Grid Guard DLT project different DLT technologies were studies, and an assessment was performed on DLT technology vulnerabilities, uses, and key characteristics. DLT consensus protocols were studies (e.g., RAFT, named after Reliable, Replicated, Redundant, And Fault-Tolerant). Also, cryptography, public, private and permissioned or permissionless systems were assessed. Grid Guard implements a permissioned private DLT. Consensus algorithm selection and choice of DLT implementation depended heavily on the use-case. For this use-case, parameters were selected to measure performance and existing tools for assessment. Benchmarking was performed theoretically and practically. During phase 2 hashed transactions/blocks were inserted into the ledger every second. During phase 2 of the Grid Guard DLT project, a prototype framework was developed and demonstrated for attestation of critical substation devices and data using precision timing systems that use PTP and IRIG-B protocols) on a testbed of operational devices that emulated a distribution substation, control center, and power metering infrastructure using real Operational Technology (OT). The testbed includes OT devices such as protective relays, human machine interfaces (HMI), and power meters. To determine when to collect and compare system and network baselines, an initial examination of an anomaly detection capability to identify malicious manipulation of data streams was conducted. The resulting anomaly detection was demonstrated in a set of experiments and leveraged to trigger device artifact attestation checks. Attestation checks occur against device configuration baselines when compared with the immutable blockchain-stored baselines, which provided a cryptographically supported means by which to store baselines. The electrical substation-grid testbed was created to test the Grid Guard framework. The testbed emulates the operations of a portion of a power grid and SCADA systems as closely as possible. The testbed integrates real protocols, mainly IEC 61850 standard protocols, such as the Sampled Value (SV) and the GOOSE protocols. The testbed also supports DNP3 and other layer 2 and layer 3 protocols such as Telnet, SSH, SFTP/FTP and other proprietary protocols needed to connect to industrial control system equipment. The testbed emulates real power conditions using the OpalRT hardware-in-the-loop (HIL) device which can create fault situations that cannot be easily tested on real systems. The electrical substation-grid testbed was created using real measurement, communication, and protection devices that electrical utilities commonly use.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A review of energy storage for power system resilience: Functions, metrics, and applications

Aging infrastructure, increasing operational complexity, and surging electricity demand from artificial intelligence and electrification are straining the grid and heightening the risks of disruptions, making resilience a critical priority. Energy storage is increasingly deployed to provide critical power supply, fast grid support, and rapid restoration. However, current practice lacks consistent metrics and systematic methodologies to rigorously quantify the resilience benefits of storage. This paper provides a comprehensive review of energy storage in resilience enhancement, focusing on functional roles, quantification metrics, and integration strategies. A structured resilience metrics library is compiled and categorized to encompass both technical and economic performance aspects. Existing methodologies for resilience-oriented storage planning and operations are critically examined. Key technical and practical challenges are identified, and future research directions are outlined to strengthen storage contributions to grid resilience.

Benefit quantification↗

On the Impact of High-Order Harmonic Generation in Electrical Distribution Systems

The modern power grid has seen a rise in the integration of non-linear loads, presenting a significant concern for operators. These loads introduce unwanted harmonics, leading to potential issues such as overheating and improper functioning of circuit breakers. In pursuing a more sustainable grid, the adoption of electric vehicles (EVs) and photovoltaic (PV) systems in residential networks has increased. Understanding and examining the effects of high-order harmonic frequencies beyond $1.5$ kHz is crucial to understanding their impact on the operation and planning of electrical distribution systems under varying nonlinear loading conditions. This study investigates a diverse set of critical power electronic loads within a household modeled using PSCAD/EMTdc, analyzing their unique harmonic spectra. This information is utilized to run the time-series harmonic analysis program in OpenDSS on a modified IEEE 34 bus test system model. The impact of high-order harmonics is quantified using metrics that evaluate total harmonic distortion (THD), transformer harmonic-driven eddy current loss component, and propagation of harmonics from the source to the substation transformer.

Peerzada, Aaqib A. [BATTELLE (PACIFIC NW LAB)]↗