Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric load profiles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

EV Hosting Capacity Analysis on Distribution Grids: Preprint

Increasing electric vehicle (EV) charging loads can increase the magnitude and duration of conventional peaks in demand profiles and even shift them significantly, causing operational violations in the distribution grid. It is important to develop tools to quantify the impacts of injecting large number of EV charging loads and determine the available capacity of the existing distribution feeder for the safe operation of the grid. Such tools would enable utilities to better prepare for grid operations in the near future while exploring the impact and effectiveness of strategies such as peak pricing and smart charging in managing these loads. This paper evaluates the hosting capacity of some real-world feeders to accommodate EV charging loads, including extreme fast-charging (xFC) options.

47 OTHER INSTRUMENTATION↗

Electrification Futures Study: Methodological Approaches for Assessing Long-Term Power System Impacts of End-Use Electrification

By its nature, electrification enhances the coupling between the electric sector and end-use sectors. Assessing the impacts of electrification requires both an examination of the complex interactions between sectors and a broader assessment of multiple parts of the energy system. The Electrification Futures Study (EFS) uses several complementary modeling and analysis tools to analyze the impacts of electrification on the U.S. energy system. In particular, the EFS relies on an overarching scenario analysis approach, but through the use of separate modeling approaches designed to assess various electricity demand- and supply-side futures. The primary model employed to generate the supply-side scenarios is the Regional Energy Deployment System (ReEDS) model, which is a capacity expansion model for the U.S. electricity system through 2050. Traditionally, the model has been primarily exercised in scenario analysis that implicitly assumed limited electrification. Because of this assumption, resulting future load profiles are approximated by historical ones, load growth is driven primarily by population and economic growth only, and changes in direct end-use natural gas consumption do not effect natural gas costs for electricity generation. In this report, we (1) reflect the potential for resource sharing between regions given these changes in demand, (2) represent how changes in natural gas consumption in end-use sectors could impact the economics of natural gas-fired generation, and (3) document a new model representation of demand-side flexibility used for the EFS. These improvements to ReEDS are employed for the EFS supply-wide analysis, which is summarized in a companion EFS report titled Electrification Futures Study: Scenarios of Power System Evolution and Infrastructure Development for the United States (Murphy et al. 2019). The data and methods documented in this report could also be adapted for other models with similar scope and limitations as ReEDS, and these data and methods could be used to assess future electric system scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation and New Windows

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Window Replacement, Exterior Wall Insulation, and Roof Insulation, which we will refer to collectively as the "High Efficiency Envelope" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single heating, ventilation, and air-conditioning (HVAC) end-use savings shape measure - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation. This measure replaces existing multi-zone variable air volume (VAV) systems or single-zone rooftop units (RTU) with a VRF HR system coupled with a DOAS that includes an energy/heat recovery ventilator (E/HRV). The measure covers 53% of exisiting building stock's floor area and is not applicable to HVAC system types using district heating or cooling or buildings/spaces that include high-ventilation spaces such as kitchens where the amount of exhaust air is large. A DOAS with E/HRV is used to provide required outdoor ventilation air to spaces since ventilation air is generally not supplied by a VRF HR system. An exhaust air energy recovery ventilator (ERV ) with sensible and latent heat exchange is added to humid climate zones while a heat recovery ventilator (HRV ) with sensible only exchange is added to drier climate zones. The ERV is modeled as a fixed membrane plate counterflow heat exchanger, while the HRV is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and minimum exhaust temperature control for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: LED Lighting

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a timeseries profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - LED lighting. The LED lighting measure replaces interior lights with LEDs where applicable. The measure resulted in 1.25 TBtu energy savings across the building stock, with the majority of savings occurring in retail and warehouse buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EFFORT (EFFectiveness Of Rate sTructure for enabling demand response)

This tool helps utilities evaluate potential time of use price-plans and find effective hours for price plan on peak periods and the potential price-elastic demand response. An optimization model can be used to find tiered prices for the time of use tariffs and analyze the impact on load profiles, energy consumption, utility, and customer savings. The tool is equipped with an optimization model to determine the energy consumption of electric appliances that can leverage survey data containing information on the number of appliances owned by customers. Lastly, a statistical model can be used to predict system-level load based on exogenous parameters such as weather, time of day, month, type of day, and year. The tool is scripted in Python and uses the Pyomo python optimization language.

Duwadi, Kapil↗

Multiscale Effects Masked the Impact of the COVID-19 Pandemic on Electricity Demand in the United States

Shelter-in-place orders and business closures related to COVID-19 changed the hourly profile of electricity demand and created an unprecedented source of uncertainty for the grid. The potential for continued shifts in electricity profiles has implications for electricity sector investment and operating decisions that maintain reserve margins and provide grid reliability. This study reveals that understanding this uncertainty requires an understanding of the underlying drivers at the customer-class scale. This paper utilizes three datasets to compare the impacts of COVID-19 on electricity consumption across a range of spatiotemporal and customer scales. At the utility/customer-class scale, COVID-19-induced shutdowns in the spring of 2020 shifted weekday residential load profiles to resemble weekend profiles from previous years. Total commercial loads declined, but the commercial diurnal load profile was unchanged. With only total loads available at the balancing authority scale, the apparent impact of COVID-19 was smaller during the summer due in part to phased re-opening and spatial variability in re-opening, but there were still clear variations once total loads were broken down zonally. Monthly data at the state scale showed an increase in state-level residential electricity sales, a decrease in commercial sales, and a small net decrease in total sales in most states from April-August 2020. Analyses that focus on total load or a single scale may miss important changes that become apparent when the load is broken down regionally or by customer class.

COVID-19, electricity demand, multiscale, Commonwe↗

Economic Dispatch Optimization of Multi-Unit SMR Site

With the increase of integration of variable renewable into the grid, grid resilience can be compromised without flexible electricity suppliers. Flexible operation of NPP can expand the scope of integration of new nuclear power plants in regions with high share of renewables. It also provides opportunity to increase profits through participation in ancillary services. In this research, NuScale modules are used as the case study. NuScale is an integrated pressurized water reactor with thermal power of 250 MWth. Having multiple units can provide higher flexibility in changing power levels and supplying the grid with electricity all year long. Additionally, load-following might perturbate the ordered sequence of refueling (every 24 months for NuScale). To maintain the 2 year refueling cycles, the loading patterns will need to be adjusted in a year-to-year basis, resulting in additional unnecessary costs. Another solution is to find the optimal outage schedule. This will also shift the focus of the planned outage to a more optimized predictive outages and maintenance. Results from short-term optimization (i.e., daily participation in energy and ancillary services markets) shows that average commitment to regulation down ancillary service markets during late night and early morning hours can increase revenues. Participating in upward reserves during pre-work commuting hours and early evening hours can also generate additional revenues due to high ramp up of electricity demand. Having multiple units at a single site can also help operate flexibly. Results from long-term optimization show that daily fluctuation in electric power is usually handled by few units while other units operate on base-load profile. It is possible to combine base-load operation with flexible operation to extend component remaining useful life in some units and find optimal outage schedule for the units.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Solar, Wind, and Load Forecasting Dataset for MISO, NYISO, and SPP Balancing Areas

The Performance-based Energy Resource Feedback, Optimization, and Risk Management (PERFORM) program is an initiative intended to foster "a fundamental shift in grid management rooted in an understanding of asset risk and system risk" (ARPA-E 2020). Launched by the Advanced Research Projects Agency-Energy (ARPA-E), the program supports efforts to incorporate uncertainty in electric power decision making. In support of PERFORM, the National Renewable Energy Laboratory (NREL) has produced a set of time-coincident forecasts of solar, wind, and load profiles. As part of Phase I of the PERFORM effort, NREL created a dataset that consists of one year of time-coincident load, wind, and solar actuals and probabilistic forecasts based on data from the Electric Reliability Council of Texas (ERCOT) (Bryce et al. 2023). In Phase II, NREL developed similar datasets for three other U.S. Independent System Operators (ISO): the Midcontinent Independent System Operator (MISO), the New York Independent System Operator (NYISO), and the Southwest Power Pool (SPP).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Techno-economic and environmental assessment of solar-based electrical vehicles charging stations integrated with hydrogen production

With the growing interest in adopting both commercial and residential electric vehicles (EVs) utilizing green renewable energy, the techno-economic assessment of EV charging stations with solar energy is a critical aspect of the transition to sustainable transportation. However, battery storage capacity for variable solar energy production is becoming increasingly less cost-effective due to the higher Lithium price. Complementing solar energy production and battery storage, the potential of combining green hydrogen fuel energy integration with solar energy for EV charging stations can provide a sustainable alternative to reach carbon-free transportation. This research aims to assess the technical and economic viability of grid-connected Photovoltaic (PV)-based EV charging stations across Kentucky based on existing EV load profiles. The study considers different PV system sizes, locations, orientations, and the impact of net metering policies and electricity tariffs on the profitability of the PV systems. Further, using excess PV energy, Lithium-Ion batteries will be charged, which will be assessed considering the techno-economic and environmental impacts of green EV charging stations. To further enhance green renewable energy production, we also investigated the feasibility of on-grid PV-based EV charging stations with Lithium-Ion batteries charged during low tariff periods. In comparison with these scenarios, we studied the potential benefits of integrating green hydrogen energy production using excess solar energy with and without governmental incentives. Furthermore, we assess the environmental impact of these green EV charging stations across Kentucky. Our study indicates that EV stations across Kentucky have similar techno-economic feasibility with insignificant deviation in the levelized cost of electricity, payback period, and PV energy fraction with/without Li-Ion batteries. However, with green hydrogen production, the marginal H 2 production cost indicates the first scenario (on-grid PV energy charging) is the most significant, roughly 10 USD/Kg, which is similar to 1.5 times higher than the second (charging during low-tariff periods) and the third scenarios (power grid to satisfy the demand deficit - approximately 6.5 USD/Kg). From the environmental perspective, the second scenario would be a good option for either hybrid EV/H 2 or EV charging stations in Kentucky, factoring in the hydrogen production cost and the carbon footprint.

08 HYDROGEN↗

Early Battery Performance Prediction for Mixed Use Charging Profiles Using Hierarchal Machine Learning

A key step limiting how fast batteries can be deployed is the time necessary to provide evaluation and validation of performance. Using data analysis approaches, such as machine learning, the validation process can be accelerated. However, questions on the validity of projecting models trained on limited data or simple cycling profiles, such as constant current cycling, to real-world scenarios with complex loads remains. Here, we present the ability to predict performance with less than 1.2% mean absolute percent error when trained on cells aged using complex electric vehicle discharge profiles, and either AC Level 2 charge or DC Fast charge profiles, using only the first 45 cycles, namely 5% of the total testing time. While error is low across the projections, this study also highlights that battery lifetime analysis using only cycling data may not extrapolate safely to certain real-world conditions due to the impact of calendar degradation.

25 ENERGY STORAGE↗

A method for modeling battery-temperature-aware EV power profiles utilizing Next-Gen Profile data

With the expected increase in the number of electric vehicles (EVs) on the road in the coming years, it is important that analysis tools are capable of modeling and predicting the expected load on the power grid due to both individual EV charging sessions as well as large populations of vehicles. To do this accurately, the power profile of an EV charge session must be accurately modeled, including for scenarios where the temperature is above or below the ideal, and also take into account the nuances of manufacturer charging preferences. This paper introduces a method that utilizes the data in the Next-Gen Profile (NGP) data collection project to build a model of EV charging that takes into account the variations in charging power that occur due to off-nominal battery temperature and manufacturer preferences that limit power due to cold temperatures or high battery state-of-charge.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Estimating the Breakeven Cost of Delivered Electricity to Charge Class 8 Electric Tractors

As vehicle electrification expands from the light-duty sector to include larger commercial medium- and heavy-duty vehicles, businesses need to decide if electrification is appropriate for their fleets. A key factor in this decision will be the total cost of ownership for on-road electric Class 8 tractors compared to their combustion counterparts. This report examines the breakeven price of electricity for electric Class 8 tractor charging to address its importance in the total cost of ownership for the operation of an electrified fleet and to account for the inherent differences of higher-power charging. To understand the likely cost of delivered energy--in this report the breakeven price--to charge electric tractors, this study followed an analysis framework that considers a wide range of factors to estimate the breakeven price to charge at various station types. This requires an estimation of electric vehicle adoption trajectories and analysis of real-world fleet data to assess energy needs of heavy-duty electric tractors and to determine expected charging station demand over time. Station demand informs the level of electric vehicle supply equipment (EVSE) deployment that is necessary at each station type, as well as the site utilization and anticipated load profiles. Then, by accounting for a wide range of capital investments, operating costs, and other expenses, a breakeven price of energy is determined.

33 ADVANCED PROPULSION SYSTEMS↗

Probabilistic impact of electricity tariffs on distribution grids considering adoption of solar and storage technologies

This study models the role of electricity tariffs on the long-term adoption of photovoltaic and storage technologies as well as the consequent impact on the distribution grid. An adoption model that captures the economic rationality of tariff-driven investments and considers the stochastic nature of individual consumers’ decisions is proposed. This model is then combined with a probabilistic load flow to evaluate the long-term impacts of the adoption on the voltage profiles of the distribution grid. To illustrate the methodology, different components of the electricity tariffs, including solar compensation mechanisms and time differentiation of Time-of-Use (ToU) rates, are evaluated, using a case study involving a section of a medium-voltage network with 118 nodes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

CELCAP: A Computer Model for Cogeneration System Analysis

A description of the CELCAP cogeneration analysis program is presented. A detailed description of the methodology used by the Naval Civil Engineering Laboratory in developing the CELCAP code and the procedures for analyzing cogeneration systems for a given user are given. The four engines modeled in CELCAP are: gas turbine with exhaust heat boiler, diesel engine with waste heat boiler, single automatic-extraction steam turbine, and back-pressure steam turbine. Both the design point and part-load performances are taken into account in the engine models. The load model describes how the hourly electric and steam demand of the user is represented by 24 hourly profiles. The economic model describes how the annual and life-cycle operating costs that include the costs of fuel, purchased electricity, and operation and maintenance of engines and boilers are calculated. The CELCAP code structure and principal functions of the code are described to how the various components of the code are related to each other. Three examples of the application of the CELCAP code are given to illustrate the versatility of the code. The examples shown represent cases of system selection, system modification, and system optimization.

Source record↗

Impact of electric vehicle charging on the power demand of retail buildings

As electric vehicle penetration increases, charging is expected to have a significant impact on the grid. Electric vehicle charging stations will greatly affect a building site's power demand, especially with the onset of fast charging with power levels as high as 350 kW per charger. Here, we assess how electric vehicle charging stations would impact a retail big box grocery store, exploring numerous station sizes, charging power levels, and utilization factors in various climate zones and seasons. We measure the effect of charging by assessing changes in monthly peak power demand, electricity usage, and annual electricity bill, computed using three distinct rate structures. We find that an electric vehicle station has the potential to dwarf a big box building's power demand if behind the same meter, increasing monthly peak power demand at the site by over 250%. Cold-climate areas paired with rate structures incorporating high demand charges are most susceptible for significant changes to the annual electricity bill, with increases as high as 88%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fast Charging Infrastructure for Electrifying Road Trips to and from National Parks in the Western United States

National parks in the Western United States draw over 80 million visitors every year, and most visitors rely on personal cars for their road trips (or long-distance travels). Travel to national parks represents distinct travel demand, as they are typically located in remote areas necessitating long-distance trips. This study investigates the quantity and locations of on-route fast charging infrastructure needed by 2030 to enable seamless travel to/from national parks using electric vehicles in seven target states in the region, employing unprecedented high-resolution spatial and temporal analysis. We find that the required number of fast charging ports for on-route charging infrastructure ranges from 1,200 to 22,000, depending on different assumptions of key input parameters - vehicle electrification rate, charging behavior, average gap between charging stations, port utilization rate, and towing trailers. Our analysis also indicates that electrical load for on-route fast charging infrastructure would peak in the afternoon, in the range of 70-400 MW, varying with the key input parameters. This study illustrates how different input parameters result in different degrees of impact on various aspects of charging infrastructure. We also examine the characteristics of projected charging infrastructure in terms of land use type, relationship with traffic volume, size of stations, and other variables.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frozen Freedom: Unleashing Grocery Store Demand Flexibility: Preprint

Grocery stores consumed approximately 3% of total electricity used by commercial buildings in the U.S. in 2018 (EIA 2018), representing a unique end-use load profile characterized by the critical use of refrigerated display cases. Exploring demand response (DR) scenarios in grocery stores presents an opportunity to enhance the efficiency and sustainability of surrounding communities. In addition, recent studies demonstrate that implementing control algorithms considering demand flexibility strategies can lead to load and peak reductions in standalone refrigerated display cases. Because small business grocery stores operate on thin margins, the energy bill cost savings DR might provide could make a positive difference toward continued operations. Still, uncertainty remains about the extent of demand flexibility potential controls could provide when coupling refrigeration with whole building operation. To enhance economic viability and grid stability, it is essential to quantify the load flexibility capability of grocery stores. Advanced controls can optimize energy consumption by responding to load shedding, shifting, and DR events, as well as daily Time-of-Use (TOU) rates without compromising food safety. Using both quantitative data and interviews with community-based organizations, we developed a full-size store model and two small store models with controlled refrigerated cases, HVAC, and lighting systems based on actual grocery store properties. Through simulations, we have assessed load flexibility strategies with varied DR events. The results highlight potential for energy and peak reduction with advanced or basic controls. However, interviews and data indicate that more support is needed to make DR strategies consistently accessible to small grocery stores.

demand flexibility↗