Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “edge sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Development of Transition Edge Sensor Detectors Optimized for Single-Photon Spectroscopy in the Optical and Near-Infrared

The search for biosignatures in the atmospheres of exoplanets will be a key focus of future space telescopes that operate in the ultraviolet, visible, and near-infrared bands. Detection of biosignatures requires an instrument with moderate spectral resolving power ($R \sim 100$) and a large bandwidth ($\sim 400$ nm -- $\sim 1.8$ $\mu$m). Additionally, biosignature detection is a photon-starved science; instruments designed for these measurements would ideally combine high optical efficiency with quantum-limited photon detectors (i.e., detectors that exhibit zero dark current). In this work, we report on our efforts to develop energy resolving transition edge sensor (TES)-based detectors designed for biosignature detection. TESs operated as microcalorimeters are compelling detectors for this application. Unlike semiconductor detectors, TESs eliminate the need for dispersive optics and are truly single photon detectors -- fundamental TES noise yields uncertainty in the energies of detected photons, not in the number of detected photons. We introduce TESs designed for this application and discuss the path toward realizing a TES-based dispersionless spectrometer optimized for biosignature detection.

Instrumentation and Photography↗

Reduced-Scale Transition-Edge Sensor Detectors for Solar and X-Ray Astrophysics

We have developed large-format, close-packed X-ray microcalorimeter arrays fabricated on solid substrates, designed to achieve high energy resolution with count rates up to a few hundred counts per second per pixel for X-ray photon energies upto 8 keV. Our most recent arrays feature 31-micron absorbers on a 35-micron pitch, reducing the size of pixels by about a factor of two. This change will enable an instrument with significantly higher angular resolution. In order to wire out large format arrays with an increased density of smaller pixels, we have reduced the lateral size of both the microstrip wiring and the Mo/Au transition-edge sensors (TES). We report on the key physical properties of these small TESs and the fine Nb leads attached, including the critical currents and weak-link properties associated with the longitudinal proximity effect.

Arrays↗

High-resolution X-ray emission spectroscopy with transition-edge sensors: present performance and future potential

X-ray emission spectroscopy (XES) is a powerful element-selective tool to analyze the oxidation states of atoms in complex compounds, determine their electronic configuration, and identify unknown compounds in challenging environments. Until now the low efficiency of wavelength-dispersive X-ray spectrometer technology has limited the use of XES, especially in combination with weaker laboratory X-ray sources. More efficient energy-dispersive detectors have either insufficient energy resolution because of the statistical limits described by Fano or too low counting rates to be of practical use. This paper updates an approach to high-resolution X-ray emission spectroscopy that uses a microcalorimeter detector array of superconducting transition-edge sensors (TESs). TES arrays are discussed and compared with conventional methods, and shown under which circumstances they are superior. It is also shown that a TES array can be integrated into a table-top time-resolved X-ray source and a soft X-ray synchrotron beamline to perform emission spectroscopy with good chemical sensitivity over a very wide range of energies.

Uhlig, J.↗

Development of a Transition-Edge Sensor Anti-Coincidence Detector for a Probe Class Mission

The Light Element Mapper (LEM), a probe class mission proposal slated for submission in 2023, combines a large X-ray optic with an extremely large format microcalorimeter array to probe the physics of galaxy formation with a grasp 22x greater than ATHENA and 7x greater than Lynx. The focal plane for LEM requires a larger anti-coincidence detector than the other missions while maintaining or exceeding their high-speed response, presenting a challenge for claiming technical readiness at the time of the announcement of opportunity (AO). We will perform a rapid demonstration in the next year including design, fabrication and integration and test of a high-fidelity transition-edge sensor (TES) based device at a scale suitable for LEM.

James Chervenak↗

Development of Holmium-163 electron-capture spectroscopy with transition-edge sensors

Calorimetric decay energy spectroscopy of electron-capture-decaying isotopes is a promising method to achieve the sensitivity required for electron neutrino mass measurement. The very low total nuclear decay energy (Q EC < 3 keV) and short half-life (4570 years) of 163 Ho make it attractive for high-precision electron-capture spectroscopy (ECS) near the kinematic endpoint, where the neutrino momentum goes to zero. In the ECS approach, an electron-capture-decaying isotope is embedded inside a microcalorimeter designed to capture and measure the energy of all the decay radiation except that of the escaping neutrino. We have developed a complete process for proton irradiation-based isotope production, isolation, and purification of 163 Ho. We have developed transition-edge sensors for this measurement and methods for incorporating 163 Ho into high-resolution microcalorimeters, and have measured the electron-capture spectrum of 163 Ho. Finally, we present our work in these areas and discuss the measured spectrum and its comparison to current theory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ASCENT: a balloon-borne hard x-ray imaging spectroscopy telescope using transition edge sensor microcalorimeter detectors

Core collapse supernovae are thought to be one of the main sources in the galaxy of elements heavier than iron. Understanding the origin of the elements is thus tightly linked to our understanding of the explosion mechanism of supernovae and supernova nucleosynthesis. X-ray and gamma-ray observations of young supernova remnants, combined with improved theoretical modeling, have resulted in enormous improvements in our knowledge of these events. Here, the isotope Ti44 is one of the most sensitive probes of the innermost regions of the core collapse engine, and its spatial and velocity distribution are key observables. Hard x-ray imaging spectroscopy with the Nuclear Spectroscopic Telescope Array (NuSTAR) has provided new insights into the structure of the supernova remnant Cassiopeia A (Cas A), establishing the convective nature of the supernova engine. However, many questions about the details of this engine remain. We present here the concept for a balloon-borne follow-up mission called A SuperConducting ENergetic x-ray Telescope (ASCENT). ASCENT uses transition edge sensor gamma-ray microcalorimeter detectors with a demonstrated 55-eV full-width half maximum energy resolution at 97 keV. This 8- to 16-fold improvement in energy resolution over NuSTAR will allow for high-resolution imaging and spectroscopy of the Ti44 emission. This will allow for a detailed reconstruction of gamma-ray line redshifts, widths, and shapes, allowing us to address questions such as, What is the source of the neutron star kicks? What is the dominant production pathway for Ti44? Is the engine of Cas A unique?

79 ASTRONOMY AND ASTROPHYSICS↗

Achieving BLISS: Challenges for Building Fast, Ultra-Sensitive Transition-Edge Sensors

Topics: 1.Motivation and Intro to TESs. 2. BLISS Specifications-tolerance to dark power. 3.Measuring stray (dark) power-Tc (alpha) and G measurements. a) Overview two methods: JTD vs. TES. b) TES arrays: measurement and complications for Pd, Tc, and alpha. 4. Results: Pd compare, NEP, tau, 1/f issues. LIRGs and ULIRGs: Excellent example of distinct optical/UV and IR luminosity. Interaction long known, but huge luminosity is not predicted based on optical studies. (greater than 90% of the energy is emitted at in the far-IR). Large luminosity has both starburst and accretion components.

Transition-edge sensors (TESs)↗

Characterization of the Thermal Properties of Ir/Pt Bilayer Transition Edge Sensors

In this work, we are developing a low-T c TES-based large-area and low-threshold detector targeting a variety of potential applications. The detector consists of a 50.8-mm-diameter Si wafer as the substrate and radiation absorber, a single Ir/Pt bilayer TES sensor in the center, and normal metal Au pads added to the TES to strengthen the TES–absorber thermal coupling. Tight TES–absorber thermal coupling improves detector sensitivity and response uniformity. Here, we report on the electron–phonon (e–ph) coupling strengths for the Ir/Pt bilayer and Au that are measured with our prototype detectors and TES devices. We found that a second weak thermal link besides the one due to e–ph coupling in Ir/Pt or Au was required to explain our data. With the effects of the second weak link accounted for, the extracted e–ph coupling constant Σ for Ir/Pt bilayer in the T c range between 32 and 70 mK is 1.9×10 8 WK -5 m -3 , and Σ’s for Au at 40 mK and 55 mK are 2.2×10 9 WK -5 m -3 and 3.2×10 9 WK -5 m -3 , respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Linear array optical edge sensor

A series of independent parallel pairs of light emitting and detecting diodes for a linear pixel array, which is laterally positioned over an edge-like discontinuity in a workpiece to be scanned, is disclosed. These independent pairs of light emitters and detectors sense along intersecting pairs of separate optical axes. A discontinuity, such as an edge in the sensed workpiece, reflects a detectable difference in the amount of light from that discontinuity in comparison to the amount of light that is reflected on either side of the discontinuity. A sequentially sychronized clamping and sampling circuit detects that difference as an electrical signal which is recovered by circuitry that exhibits an improved signal-to-noise capability for the system.

Bejczy, Antal K.↗

Optoelectronic polymer memristors with dynamic control for power-efficient in-sensor edge computing

Abstract As the demand for edge platforms in artificial intelligence increases, including mobile devices and security applications, the surge in data influx into edge devices often triggers interference and suboptimal decision-making. There is a pressing need for solutions emphasizing low power consumption and cost-effectiveness. In-sensor computing systems employing memristors face challenges in optimizing energy efficiency and streamlining manufacturing due to the necessity for multiple physical processing components. Here, we introduce low-power organic optoelectronic memristors with synergistic optical and mV-level electrical tunable operation for a dynamic “control-on-demand” architecture. Integrating signal sensing, featuring, and processing within the same memristors enables the realization of each in-sensor analogue reservoir computing module, and minimizes circuit integration complexity. The system achieves 97.15% fingerprint recognition accuracy while maintaining a minimal reservoir size and ultra-low energy consumption. Furthermore, we leverage wafer-scale solution techniques and flexible substrates for optimal memristor fabrication. By centralizing core functionalities on the same in-sensor platform, we propose a resilient and adaptable framework for energy-efficient and economical edge computing.

Optics↗