Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dry lubricant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Gas bearings

The present work deals with the fundamentals of gas lubrication theory, which forms the foundation of all analytical design tools for gas bearings. Most of the hard lessons learned in the past are outlined with reference to dry contact, debris ingestion, sliding speed, and chemical stability of lubricant. The mathematical theory of gas lubrication is described for scaling rules in thin-film viscous flow, momentum conservation, mass conservation, energy conservation, isothermal gas bearing theory, coupling effects, and global bearing characteristics. Particular attention is given to the governing differential equations for common bearing configurations. Also discussed are representative solutions of self-acting gas bearings, externally pressurized bearings, and time-dependent effects.

Pan, C. H. T.↗

A comparison of the lubricating mechanisms of graphite fluoride and molybdenum disulfide films

A microscopic study of 440 C steel sliding surfaces lubricated by graphite fluoride or molybdenum disulfide solid lubricant rubbed films was conducted. The sliding surfaces, along with the friction, wear, and wear life were observed as a function of the number of sliding revolutions in three different atmospheres: moist air (10,000 ppm H2O), dry air (less than 20 ppm H2O), or dry argon (less than 20 ppm H2O). In general, the lubricating mechanisms of the two solid lubricants were found to be relatively similar; that is, a dynamic, thin, layer-like film (which sheared on relative motion) was formed between the two metallic surfaces. The mechanisms of failure were found to be somewhat different, however. Failure of MoS2 films was very dependent on atmospheric degradation, while that of graphite fluoride films was more dependent on flow of the lubricant film out of the contact zone

Fusaro, R. L.↗

A new solid lubricant

Friction and wear life studies on burnished films of the compound graphite fluoride have demonstrated its potential as a solid lubricant material. It is effective in moist air, dry air, or in dry argon at temperatures up to approximately 400 degrees C.

Fusaro, R. L.↗

Comparison of release torques of tightened bolts in vacuum and air

Various combinations of stainless steel, mild steel, and aluminum bolt-nut couples are tightened to 60 lb-ft in partial vacuum and in air. Results are given for tests with and without two lubricants /a fluorosilicone and a sodium silicate bonded dry-film/.

Demorest, K. E.↗

Boundary lubrication of formulated C-ethers in air to 300 C. 2: Organic acid additives

Friction and wear measurements were made on CVM M-50 steel lubricated with three C-ether (modified polyphenyl ether) formulations in dry and moist air. Results were compared to those obtained with a formulated Type 2 ester and the C-ether base fluid. A ball-on-disk sliding friction apparatus was used. Experimental conditions were a 1-kilogram load, a 17-meter/minute surface speed, and a 25 to 300 C (77 to 572 F) disk temperature range. The three C-ether formulations yielded better boundary lubricating characteristics than the Type 2 ester under most test conditions. All C-ether formulations exhibited higher friction coefficients than the ester from 150 to 300 C (302 to 572 F) and similar or lower values from 25 to 150 C (77 to 302 F).

Jones, W. R., Jr.↗

The effect of coatings and liners on heat transfer in a dry shaft-bush tribosystem

The temperatures due to frictional heating within a solid lubricated or coated journal bearing were analyzed by using a finite element method. A solid model of the shaft-bush tribocontact was generated with an eight-node, three-dimensional, first-order isoparametric heat-transfer element and the Patran solid modeler software. The Patmar (Patran-Marc) translator was used to help develop the Marc-based finite element program for the system; this software was used on the Cray X-MP supercomputer to perform a finite element analysis of the contact. The analysis was performed for various liner materials, for thin, hard, wear-resistant coated bearings, and for different geometries and thermal cooling boundary conditions. The analyses indicated that thermal conductivity of the liner or coating material is the most vital thermal parameter that controls the interface temperature. In addition to design variations, the proximity of the cooling source to the heat-flux-generating interface is critically important to the temperature control in the system.

Ghosh, Mihir K.↗

Dynamic Nanocrystal Superlattices with Thermally Triggerable Lubricating Ligands

The size-dependent and collective physical properties of nanocrystals (NCs) and their self-assembled superlattices (SLs) enable the study of mesoscale phenomena and the design of metamaterials for a broad range of applications. However, the limited mobility of NC building blocks in dried NCSLs often hampers the potential for employing postdeposition methods to produce high-quality NCSLs. In this study, we present tailored promesogenic ligands that exhibit a lubricating property akin to thermotropic liquid crystals. The lubricating ability of ligands is thermally triggerable, allowing the dry solid NC aggregates deposited on the substrates with poor ordering to be transformed into NCSLs with high crystallinity and preferred orientations. The interplay between the dynamic behavior of NCSLs and the molecular structure of the ligands is elucidated through a comprehensive analysis of their lubricating efficacy using both experimental and simulation approaches. Coarse-grained molecular dynamic modeling suggests that a shielding layer from mesogens prevents the interdigitation of ligand tails, facilitating the sliding between outer shells and consequently enhancing the mobility of NC building blocks. Further, the dynamic organization of NCSLs can also be triggered with high spatial resolution by laser illumination. The principles, kinetics, and utility of lubricating ligands could be generalized to unlock stimuli-responsive metamaterials from NCSLs and contribute to the fabrication of NCSLs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Achieving clean production with nanostructured coated milling tools dry machining low carbon steel

The advancement of clean production using nanostructured materials in subtractive manufacturing processes has focused on replacing the use of liquid lubrication with solid lubricants coated to conventional cutting tools machining low carbon steel (~ 0.2 wt. % carbon). However, little is known about the wear mechanisms that dominate such tools when coated with functional graded nanostructured coatings. The present study follows an international standard for characterizing such wear (ISO 8688) but uses advanced measurement techniques such as x-ray fluorescence technology to measure the diffusion of chemical species from tool to workpiece and vice versa, that contributes to tool wear with the view to enhance the principles of cleaner production. The results show that when commercially-available tools coated with the appropriate functionally graded industrial coating, diffusion does not take place and creates an effective chemical barrier during machining. The experimental methods used in the study include machining workpieces using a CNC milling machine, tachometer for measuring spindle speed, dynamometer for measuring cutting forces, infra-red camera for measuring cutting temperatures, chemical species diffusion wear using x-ray florescence detector, and an optical microscope for measuring tool wear. Coupled with the physical measurement of wear, it is concluded that mechanical wear dominates the milling of a low carbon steel and that thermal properties of the coatings do not correlate with such wear. It is also concluded that flank wear as a function of volume of workpiece removed and machining duration (machining index) is a sound method for assessing the transition of the stages of wear during clean machining operations. The present study not only has implication for the design of better cutting tools, but also advances dry machining processes that eliminate the use of liquid lubricants making subtractive production processes cleaner. The main conclusions drawn from this study show that coated tools have a longer life under dry conditions compared to uncoated tools and that there is no correlation between coating properties and tool wear. In conclusion, diffusion of chemical species into the cut chips did not occur because of the lack of thermally induced chemical wear of the cutting tool and that wear is caused by the gradual erosion of the flank face due to the chip abrading the cutting tool.

36 MATERIALS SCIENCE↗

The Effect of 17-4 PH Stainless Steel on the Lifetime of a Pennzane(Trademark) Lubricated Microwave Limb Sounder Antenna Actuator Assembly Ball Screw for the AURA Spacecraft

During ground based life testing of a Microwave Limb Sounder (MLS) Antenna Actuator Assembly (AAA) ball-screw assembly, lubricant darkening and loss were noted when approximately 10 percent of required lifetime was completed. The MLS-AAA ball screw and nut are made from 17-4 PH steel, the nut has 440C stainless steel balls, and the assembly is lubricated with a Pennzane formulation containing a three weight percent lead naphthenate additive. Life tests were done in dry nitrogen at 50 C. To investigate the MLS-AAA life test anomaly, Spiral Orbit Tribometer (SOT) accelerated tests were performed. SOT results indicated greatly reduced relative lifetimes of Pennzane formulations in contact with 17-4 PH steel compared to 440C stainless steel. Also, dry nitrogen tests yielded longer relative lifetimes than comparable ultrahigh vacuum tests. Generally, oxidized Pennzane formulations yielded shorter lifetimes than non-oxidized lubricant. This study emphasizes surface chemistry effects on the lubricated lifetime of moving mechanical assemblies.

Jones, William R., Jr.↗

Boundary lubrication of formulated C-ether in air to 300 deg C. 1: Phosphorus ester additives

Friction and wear measurements were made on CVM M-50 steel lubricated with three C-ether (modified polyphenyl ether) formulations in dry and wet air. Results were compared to those obtained with a formulated Type 2 ester and the C-ether base fluid. A ball-on-disk sliding friction apparatus was used. Experimental conditions were a 1-kilogram load, a 17-meter-perminute (100-rpm) surface speed, and a 25 to 300 C (77 to 572 F) disk temperature range. The C-ether base fluid and the three formulated C-ether fluids yielded lower wear than the Type 2 ester over the entire temperature range. All C-ether fluids exhibited slightly higher friction coefficients than the ester from 150 to 300 C (302 to 572 F) and similar values from 25 to 150 C (77 to 302 F). In general, lower wear rates were observed with the C-ethers when tested in wet air as compared to a dry air atmosphere.

Jones, W. R., Jr.↗

Boundary lubrication of formulated C-ethers in air to 300 C

Six C-ether formulations (containing organic acid and phosphorus ester additives) were tested in dry (less than 100 ppm H2O) and moist air (relative humidity 50 percent at 25 C) and temperatures from 25 to 300 C, in order to determine the boundary lubricating characteristics and to compare these results to those obtained with a fully formulated Type II ester and the unformulated C-ether base fluid. The apparatus, procedures and detailed results of the test are described. Friction and wear measurements were made on CVM M-50 steel under 1 kg load and 17 meter per minute (100 rpm) surface speed conditions, for a duration of 25 minutes. In general, the C-ether formulations exhibited higher friction coefficients than the ester from 150 to 300 C and similar or lower values from 25 to 150 C, furthermore, in most test conditions the C-ether base fluid and the six C-ether formulations yielded lower wear than the ester. Possible applications in the aerospace industry are mentioned.

Jones, W. R., Jr.↗

Effects of Particle Size and Concentration of Magnesium Oxide on the Lubricating Performance of a Chloride Molten Salt for Concentrating Solar Power

One engineering challenge for the next-generation concentrating solar power (CSP) is to identify appropriate heat transfer and thermal energy storage media. A chloride salt mixture (20 wt % NaCl + 40 wt % MgCl 2 + 40 wt % KCl) in a molten phase is proposed as a potential fluid for carrying the heat as well as lubricating the CSP pump bearings. Due to the hygroscopic nature of MgCl 2 , the presence of magnesium oxide (MgO) particles is inevitable. In order to understand the impact of MgO particles, this study investigated the tribological behavior of the molten chloride salt mixture containing MgO of various particle sizes and concentrations. Tests were conducted at 750 °C in a dry Ar environment using a zirconia ball sliding against a Haynes 244 alloy disc lubricated by the molten salt. There was a clear trend of the increased friction coefficient and wear loss for a larger particle size and/or a higher concentration of MgO. Distinct wear mechanisms were identified for the ceramic ball and alloy disc. Results provide fundamental insights for this new research avenue of molten salt lubrication for CSP.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Friction and Wear Properties of As-deposited and Carbon Ion-implanted Diamond Films

Recent work on the friction and wear properties of as-deposited and carbon ion-implanted diamond films was reviewed. Diamond films were produced by the microwave plasma chemical vapor deposition (CVD) technique. Diamond films with various grain sizes and surface roughnesses were implanted with carbon ions at 60 ke V ion energy, resulting in a dose of 1.2310(exp 17) carbon ions/cm(exp 2). Various analytical techniques, including Raman spectroscopy, proton recoil analysis, Rutherford backscattering, transmission and scanning electron microscopy, x-ray photoelectron spectroscopy, and x-ray diffraction, were utilized to characterize the diamond films. Sliding friction experiments were conducted with a polished natural diamond pin in contact with diamond films in the three environments: humid air (40 percent relative humidity), dry nitrogen (less than 1 percent relative humidity), and ultrahigh vacuum (10(exp -7) Pa). The CVD diamond films indeed have friction and were properties similar to those of natural diamond in the three environments. The as-deposited, fine-grain diamond films can be effectively used as self-lubricating, wear-resistant coatings that have low coefficients of friction (0.02 to 0.04) and low wear rates (10(exp -7) to 10(exp -8)mm(exp 3)/N-m) in both humid air and dry nitrogen. However, they have high coefficients of friction (1.5 to 1.7) and a high wear rate (10(exp -4)mm(exp 3/N-m) in ultrahigh vacuum. The carbon ion implanation produced a thin surficial layer (less than 0.1 micron thick) of amorphous, nondiamond carbon on the diamond films. In humid air and dry nitrogen, the ion-implanted, fine- and coarse-grain diamond films have a low coefficient of friction (around 0.1) and a low wear rate (10(exp -7)mm(exp 3/N-m). Even in ultrahigh vacuum, the presence of the nondiamond carbon layer reduced the coefficient of friction of fine-grain diamond films to 0.1 or lower and the wear rate to 10(exp -6)mm(exp 3)/N-m. Thus, the carbon ion-implanted, fine-grain diamond films can be effectively used as wear-resistant, self-lubricating coatings not only in air and dry nitrogen, but also in ultrahigh vacuum. The wear mechanism of diamond films is that of small fragments chipping off the surface. The size of wear particles is related to the extent of wear rates.

Miyoshi, Kazuhisa↗

The effects of ion implantation on the tribology of perfluoropolyether-lubricated 440C stainless steel couples

The lubricating lifetime of thin films of a perfluoropolyether (PFPE) based on hexafluoropropene oxide in the presence of ion implanted 440C stainless steel is presented. Stainless steel discs, either unimplanted or implanted with N2, C, Ti, Ti + N2, or Ti + C had a thin film of PFPE (60-400 A) applied to them reproducibly (+/- 20 percent) and uniformly (+/- 15 percent) using a device developed for this study. The lifetimes of these films were quantified by measuring the number of sliding-wear cycles required to induce an increase in the friction coefficient from an initial value characteristic of the lubricated wear couple to a final, or failure value, characteristic of an unlubricated, unimplanted couple. The tests were performed in a dry nitrogen atmosphere (less than 1 percent RH) at room temperature using a 3 N normal load with a relative sliding speed of 0.05 m/s. The lubricated lifetime of the 440C couple was increased by an order of magnitude by implanting the disc with Ti. Ranked from most to least effective, the implanted species were: Ti; Ti+C; unimplanted; N2; C approximately equals Ti+N2. The mechanism postulated to explain these results involves the formation of a passivating or reactive layer which inhibits or facilitates the production of active sites. The corresponding surface microstructures induced by ion implantation, obtained using x-ray diffraction and conversion electron Mossbauer spectroscopy, ranked from most to least effective in enhancing lubricant lifetime were: amorphous Fe-Cr-Ti; amorphous Fe-Cr-Ti-C + TiC; unimplanted; epsilon-(Fe,Cr)(sub x)N, x = 2 or 3; amorphous Fe-Cr-C approximately equals amorphous Fe-Cr-Ti-N.

Shogrin, Bradley↗

Lubrication and failure mechanisms of molybdenum disulfide films. 1: Effect of atmosphere

Friction, wear, and wear lives of rubbed molybdenum disulfide (MoS2 films applied to sanded 440C HT steel surfaces were evaluated in moist air, dry air, and dry argon. Optical microscope observations were made as a function of sliding distance to determine the effect of moisture and oxygen on the lubricating and failure mechanisms of MoS2 films. In general, the lubrication process consisted of the formation of a thin, metallic colored, coalesced film of MoS2 that flowed between the surfaces in relative motion. In air, failure was due to the transformation of the metallic colored, coalesced films to a black, powdery material. Water in the air appeared to accelerate the transformation rate. In argon, no transformation of MoS2 was observed with the microscope, but cracking and spalling of the coalesced film occurred and resulted in the gradual depletion of the film.

Fusaro, R. L.↗

Friction and Wear Properties of As-Deposited and Carbon Ion-Implanted Diamond Films

Recent work on the friction and wear properties of as-deposited and carbon ion-implanted diamond films was reviewed. Diamond films were produced by the microwave plasma chemical vapor deposition (CVD) technique. Diamond films with various grain sizes and surface roughnesses were implanted with carbon ions at 60 keV ion energy, resulting in a dose of 1.2 x 10(exp 17) carbon ions per cm(exp 2). Various analytical techniques, including Raman spectroscopy, proton recoil analysis, Rutherford backscattering, transmission and scanning electron microscopy, X-ray photoelectron spectroscopy, and X-ray diffraction, were utilized to characterize the diamond films. Sliding friction experiments were conducted with a polished natural diamond pin in contact with diamond films in the three environments: humid air (40% relative humidity), dry nitrogen (less than 1 percent relative humidity), and ultrahigh vacuum (10(exp -7) Pa). The CVD diamond films indeed have friction and wear properties similar to those of natural diamond in the three environments. The as-deposited, fine-grain diamond films can be effectively used as self-lubricating, wear-resistant coatings that have low coefficients of friction (0.02 to 0.04) and low wear rates (10(exp -7) to lO(exp -8) mm(exp 3) N(exp -1) m(exp -1)) in both humid air and dry nitrogen. However, they have high coefficients of friction (1.5 to 1.7) and a high wear rate (10(exp -4) mm(exp 7) N(exp -1) m(exp -1)) in ultrahigh vacuum. The carbon ion implantation produced a thin surficial layer (less than 0.1 micron thick) of amorphous, non-diamond carbon on the diamond films. In humid air and dry nitrogen, the ion-implanted, fine and coarse-grain diamond films have a low coefficient of friction (around 0.1) and a low wear rate (10(exp -7) mm(exp 3) N(exp -1) m(exp-1)). Even in ultrahigh vacuum, the presence of the non-diamond carbon layer reduced the coefficient of friction of fine-grain diamond films to 0.1 or lower and the wear rate to 10(exp -6) mm(exp 3) N(exp -1) m(exp -1). Thus, the carbon ion-implanted, fine-grain diamond films can be effectively used as wear-resistant, self-lubricating coatings not only in air and dry nitrogen, but also in ultrahigh vacuum.

Miyoshi, Kazuhisa↗

Lubricity of well-characterized jet and broad-cut fuels by ball-on-cylinder machine

A ball-on-cylinder machine (BOCM) was used to measure the lubricity of fuels. The fuels tested were well-characterized fuels available from other programs at the NASA Lewis Research Center plus some in-house mildly hydroprocessed shale fuels from other programs included Jet-A, ERBS fuel, ERBS blends, and blend stock. The BOCM tests were made before and after clay treatment of some of these fuels with both humidified air and dry nitrogen as the preconditioning and cover gas. As expected, clay treatment always reduced fuel lubricity. Using nitrogen preconditioning and cover gas always resulted in a smaller wear scar diameter than when humidified air was used. Also observed was an indication of lower lubricity with lower boiling range fuels and lower aromatic fuels. Gas chromatographic analysis indicted changes in BOCM-stressed fuels.

Prok, G. M.↗

Demonstration of the Feasibility of High Temperature Bearing Lubrication From Carbonaceous Gases

Research has been conducted on silicon nitride pin-on-disk sliding contacts at temperatures of up to 520 C, and four-ball rolling contacts with silicon nitride balls and 52100 steel or silicon nitride races at 590 C. These tests were conducted in a variety of gaseous environments in order to determine the effects of simulated engine exhaust gas on the carbonaceous gas decomposition lubrication scheme. In rolling tests with steel races and exhaust gas the wear track depth was roughly half that of tests run in nitrogen gas alone. The deposition of lubricous microcrystalline graphitic carbon on the rolling surfaces, generated from the carbon monoxide within the exhaust gas mixture, was verified by microfocused Raman spectroscopy. Ten-fold reductions in rolling wear could be achieved by the exhaust gas atmosphere in cases where water vapor was removed or not present. The exhaust gas mixture alone was not found to provide any lubricating effect on silicon nitride sliding contacts, where the rate of wear greatly exceeds the rate of carbon deposition. Directed admixture of acetylene (as low as 5% of the exhaust gas flow rates), has provided reductions in both wear volume and coefficient of friction by factors of 60X and 20X respectively for sliding contacts during the initial 80 m of sliding distance. Exhaust gas atmosphere with the acetylene admixture provided 65OX reductions in steady state wear rate compared to that measured for sliding contacts in dry N2. Such acetylene admixture also augments the ability of the exhaust gas atmosphere to lubricate high-temperature rolling contacts, with up to 25-fold reductions in wear track depth compared to those measured in the presence of N2 alone. In addition to providing some lubricating benefit itself, an important potential role of the exhaust gas from rich mixtures would be to shield bearings from 02. Such shielding enables surface deposition of lubricous pyrolytic carbon from the acetylene admixture, instead of combustion, rendering feasible the continuously replenished solid lubrication of high-temperature bearing surfaces.

Blanchet, Thierry A.↗