At least 145 records · Page 8

High-Resolution Near-Surface Imaging at the Basin Scale Using Dark Fiber and Distributed Acoustic Sensing: Toward Site Effect Estimation in Urban Environments

Near-surface seismic structure, particularly the shear wave velocity (V s ), can strongly affect local site response, and should be accurately estimated for ground motion prediction during seismic hazard assessment. The Imperial Valley (California), occupying the southern end of the Salton Trough, is a seismically active basin with thick surficial lacustrine sedimentary deposits. In this study, we utilize ambient noise records and local earthquake events for high-resolution near-surface characterization and site effect estimation with an unlit fiber-optic telecommunication infrastructure (dark fiber) in Imperial Valley by using the distributed acoustic sensing (DAS) technique. We apply ambient noise interferometry to retrieve coherent surface waves from DAS records, and evaluate performances of three different surface wave methods on DAS ambient noise dispersion imaging. We develop a quality control workflow to improve the dispersion measurement of noisy portions of the DAS data set by using a data selection strategy. Using the joint inversion of both the fundamental mode and higher overtones of Rayleigh waves, a high resolution two-dimensional (2D) V s structure down to 70 m depth is obtained. We successfully achieve an improved V s 30 (the time-averaged shear-wave velocity in the top 30 m) model with higher spatial-resolution and reliability compared to the existing community model for the area. We also explore the potential for utilizing DAS earthquake events for site amplification estimation. The preliminary results reveal a clear anti-correlation between the approximated site response and the V s 30 profile. In conclusion, our results indicate the potential utility of DAS deployed on dark fiber for near-surface characterization in appropriate contexts.

58 GEOSCIENCES↗

Flight Test Design and Implementation for Airspace Independent Surveillance Through a Distributed Ground Based Sensor Network

The paper presents a system architecture for distributed sensing, networking and computing, its hardware implementation, and execution of initial flight experiments to validate theoretical findings. It induces development of distributed sensing requirements, framework, and architecture, development of distributed ground node hardware prototypes, integration of all nodes and testing of baseline functionalities, integration of in-house developed perception, migration and tracking software packages, establishing flight scenario and flyable path for a selected UAS, flying the air vehicle along the path, recording sensors measurements, pre-processing them and transferring the resulting data to an optimal computing center. It also addresses the challenges related to pre-flight hardware calibration, clock synchronization, sensor registration and establishing a communication network. Sensors data processing results demonstrate the functionality of the presented distributed architecture and satisfactory performance of the applied technologies.

Target tracking↗

Method of making a distributed optical fiber sensor having enhanced Rayleigh scattering and enhanced temperature stability, and monitoring systems employing same

A method of making an optical fiber sensor device for distributed sensing includes generating a laser beam comprising a plurality of ultrafast pulses, and focusing the laser beam into a core of an optical fiber to form a nanograting structure within the core, wherein the nanograting structure includes a plurality of spaced nanograting elements each extending substantially parallel to a longitudinal axis of optical fiber. Also, an optical fiber sensor device for distributed sensing includes an optical fiber having a longitudinal axis, a core, and a nanograting structure within the core, wherein the nanograting structure includes a plurality of spaced nanograting elements each extending substantially parallel to the longitudinal axis of the optical fiber. Also, a distributed sensing method and system and an energy production system that employs such an optical fiber sensor device.

Chen, Peng Kevin↗

Distributed Acoustic Sensing (DAS) Seismic Monitoring of CO 2 Injected for Enhanced Oil Recovery in Northern Michigan (Volume II.C)

The Midwest Regional Carbon Sequestration Partnership (MRCSP) was founded in 2003 as part of the U.S. Department of Energy’s (DOE’s) Regional Carbon Sequestration Partnership initiative. Since its founding, MRCSP has made significant strides toward making CCUS a viable option for states in the region. The public/private consortium, funded through the DOE Regional Carbon Sequestration Initiative, brings together nearly 40 industry partners and 10 states. Battelle, as the project lead, oversees research, development and operations and coordinates activities among the partners. The incremental, phased approach has built a valuable knowledge base for the industry and paved the way for commercial-scale adoption of CCUS technologies. From 2008 to 2020, MRCSP Phase III focused on the development of large-scale injection projects. This report is part of a series of reports prepared under the Midwestern Regional Carbon Sequestration Partnership (MRCSP) Phase III (Development Phase). These reports summarize and detail the findings of the work conducted under the Phase III project. This report describes the monitoring study conducted to assess the effectiveness of DAS (Distributed Acoustic Sensing) -based VSP (Vertical Seismic Profiling) technology for delineating CO 2 injected into the Silurian-age pinnacle reefs in northern Michigan, the host rocks for the MRCSP Phase III demonstration project. The DAS VSP study was conducted in the Chester 16 reef, one of several reefs in Otsego County Michigan that is operated by Core Energy, LLC of Traverse City, Michigan. Time-lapse DAS VSP was implemented at the Chester 16 reef to attempt to detect approximately 85,000 tonnes of CO 2 injected into the A-1 Carbonate and Brown Niagaran Formations. A baseline survey was conducted in February 2017 prior to injecting CO 2 and a repeat survey was conducted in August 2018. During the interim period between the baseline and repeat surveys, CO 2 was injected into the Chester 16 reef via the 6-16 injection well without production (withdrawal) of fluids from the reef. A grid of 181 source positions consisting of 44 vibrator positions, plus 137 dynamite shot locations, was used to give approximately continuous spatial coverage of the injection zone (A-1 Carbonate and upper Brown Niagaran) in the area between the two wells.

01 COAL, LIGNITE, AND PEAT↗

Abstract for CRADA between National Energy Technology Laboratory and Colonial Pipeline Company

The National Energy Technology Laboratory (NETL) and Colonial Pipeline Company (Participant) will collaborate in the field demonstration of optical fiber sensor systems developed at NETL on Participant’s fuel pipeline. The optical fiber sensor technologies are capable of distributed temperature and strain sensing, distributed acoustic sensing, and ultrasensitive acoustic sensing. Real-time monitoring of these parameters enables pipeline integrity monitoring, security monitoring, flow rate monitoring, etc. Successful demonstration on a real fuel pipeline at Participant’s facilities will validate the sensor technologies and installation methods at a real scale. This effort aligns with NETL’s mission in reliable and sustainable energy and reducing environmental effects due to pipeline failures.

42 ENGINEERING↗

Discrete distributed strain sensing of intelligent structures

Techniques are developed for the design of discrete highly distributed sensor systems for use in intelligent structures. First the functional requirements for such a system are presented. Discrete spatially averaging strain sensors are then identified as satisfying the functional requirements. A variety of spatial weightings for spatially averaging sensors are examined, and their wave number characteristics are determined. Preferable spatial weightings are identified. Several numerical integration rules used to integrate such sensors in order to determine the global deflection of the structure are discussed. A numerical simulation is conducted using point and rectangular sensors mounted on a cantilevered beam under static loading. Gage factor and sensor position uncertainties are incorporated to assess the absolute error and standard deviation of the error in the estimated tip displacement found by numerically integrating the sensor outputs. An experiment is carried out using a statically loaded cantilevered beam with five point sensors. It is found that in most cases the actual experimental error is within one standard deviation of the absolute error as found in the numerical simulation.

Anderson, Mark S.↗

Distributed Acoustic Sensing to Estimate the Permeability

Optical fiber in a borehole can be interrogated with distributed acoustic sensors (DAS) to capture fracture displacements with the potential to map surrounding fracture networks. We designed a laboratory experiment to test the capability of DAS to determine borehole flow characteristics, and we show that for the first time DAS can be used to remotely estimate permeability. Optical fiber was wrapped around a bead filled pipe and the pressure drop and flow velocity were measured to directly calculate permeability. A machine learning model using statistical features from continuous DAS estimated the bulk permeability. Fluid interactions with the permeable material demonstrate insufficient resolution using DAS amplitude-based measurements for estimating pressure drop to infer permeability. Variations in the spectral domain relate DAS measurements to the pressure drop and provide consistent permeability estimates. Resolution with DAS is sufficient to estimate permeability and provides a reliable method to monitor at depth in borehole conditions.

58 GEOSCIENCES↗

Independent Orbiter Assessment (IOA): Analysis of the electrical power distribution and control subsystem, volume 1

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Electrical Power Distribution and Control (EPD and C) hardware. The EPD and C hardware performs the functions of distributing, sensing, and controlling 28 volt DC power and of inverting, distributing, sensing, and controlling 117 volt 400 Hz AC power to all Orbiter subsystems from the three fuel cells in the Electrical Power Generation (EPG) subsystem. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Of the 1671 failure modes analyzed, 9 single failures were determined to result in loss of crew or vehicle. Three single failures unique to intact abort were determined to result in possible loss of the crew or vehicle. A possible loss of mission could result if any of 136 single failures occurred. Six of the criticality 1/1 failures are in two rotary and two pushbutton switches that control External Tank and Solid Rocket Booster separation. The other 6 criticality 1/1 failures are fuses, one each per Aft Power Control Assembly (APCA) 4, 5, and 6 and one each per Forward Power Control Assembly (FPCA) 1, 2, and 3, that supply power to certain Main Propulsion System (MPS) valves and Forward Reaction Control System (RCS) circuits.

Schmeckpeper, K. R.↗

Independent Orbiter Assessment (IOA): Analysis of the Electrical Power Distribution and Control Subsystem, Volume 2

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Electrical Power Distribution and Control (EPD and C) hardware. The EPD and C hardware performs the functions of distributing, sensing, and controlling 28 volt DC power and of inverting, distributing, sensing, and controlling 117 volt 400 Hz AC power to all Orbiter subsystems from the three fuel cells in the Electrical Power Generation (EPG) subsystem. Volume 2 continues the presentation of IOA analysis worksheets and contains the potential critical items list.

Schmeckpeper, K. R.↗

Highly cascaded first-order fiber Bragg gratings in highly multimode optical fibers for distributed temperature sensing under harsh environment conditions

This study presents a pioneering technique for fabricating highly cascaded first-order fiber Bragg gratings (FBGs) using a femtosecond laser-assisted point-by-point inscription method in highly multimode optical fibers, specifically Sapphire crystalline fiber, and pure silica coreless fiber. Notably, it marks the first successful demonstration of a distributed array comprising 10 FBGs within highly multimode fibers. This achievement is facilitated by a high-power laser technique that yields larger reflectors characterized by a Gaussian intensity profile. These first-order FBGs offer various advantages, including enhanced reflectivity, reduced fabrication time, and simplified spectral characteristics, enhancing their accessibility for interpretation when contrasted with higher-order FBGs. In addition to that it encompasses a comprehensive analysis of the robustness and efficacy of these FBGs, with particular emphasis on their ability to endure extreme temperatures. These FBGs demonstrate an advantageous capability for localized multi-point temperature monitoring, reaching temperatures up to 1500°C with sapphire crystalline fiber and 1100°C with pure silica coreless fiber. This resilience makes them suitable for deployment in harsh environmental conditions. This innovative approach substantially broadens the potential applications of highly multimode optical fibers, particularly in the arena of sensing and communication, where challenges related to thermal gradients and harsh environments prevail. Furthermore, these groundbreaking first-order FBGs signify a substantial advancement in the realm of distributed temperature sensing, offering supreme capabilities for temperature monitoring and signal stability. As such, our work holds the promise of a substantial impact on industries and applications that demand unwavering reliability under extreme conditions.

47 OTHER INSTRUMENTATION↗

Fiber Optic Distributed Acoustic Sensing in DFPS East Well

Fiber optic files in *.hdf format, acquired in the Devine Fracture Pilot Site East well, using Fotech interrogator. There was no change in channel spacing or acquisition settings during the project. Channel spacing is 0.68 m.

Electrically active proppant,Electromagnetic,Fiber↗

Experimental study on the startup of the annular wick type heat pipe using fiber optical temperature measurement technique

This study used optical fiber-distributed temperature sensors to measure the internal and external temperature distributions of a water-cooled heat pipe. The sensor technology used in this study is fiber optical distributed temperature sensing, a distributed sensing technique based on the naturally occurring Rayleigh backscatter in optical fibers. This measurement technique provides maximum spatial resolution for static and semi-static applications. Using this sensor, the temperature distribution of the heat pipe's internal, external, vapor core, and the wick was measured with a spatial resolution of 0.65 mm, a sampling frequency of 40 Hz, and a temperature resolution of 0.1 °C. Through the measured temperature distribution database, the starting phenomenon, the effective length trend, and the limitation onset were observed. From the results, it is found that a high-temperature peak appears at the evaporator if a high initial power (75 W) is imposed on the heat pipe, even after the heat pipe approaches the normal operating status. The peak is not observed in a slower startup (30 W initial power then slowly increased to 75 W). It is also found that the temperature distributions and effective condenser length of the heat pipe highly depend on the cooling conditions. There are variations in the temperature according to the radial direction of the horizontal heat pipe due to gravity. In conclusion, lead and lag of the temperature evolution were observed at the onset of the operating limitations.

42 ENGINEERING↗

The Value of Information From Horizontal Distributed Acoustic Sensing Compared to Multicomponent Geophones Via Machine Learning

Abstract Faults play an important role in recharging many geothermal reservoirs, and seismic information can image the locations of these faults. The value of information (VOI) metric is used to objectively quantify and compare the value of two types of seismic receiver data via a machine learning approach. The demonstrated VOI methodology is novel by including spatial models from seismic data and obtaining the information statistics from machine learning. Our two-dimensional numerical experiments compare images created from sparsely spaced (80 m), two-component geophone sampling to high spatial resolution (1 m), single-component DAS. We used a three-fold cross validation of a U-Net convolutional neural networks to achieve average classification statistics. The results suggest that when horizontal sources are utilized, geophones and DAS identify reflectors and non-reflectors at roughly the same rate. The average F1 score for horizontal DAS is 0.939 and 0.931 for geophones. For images created from a vertical source, DAS performed marginally better (F1 = 0.919) than geophones (F1 = 0.877). Our transferrable methodology can provide guidance on which acquisition scenarios can improve images of important structures in the subsurface and present an efficient method for obtaining reliability statistics from high-dimensional, spatial data.

Energy & Fuels↗